Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 170 206 N S C BOSE ROAD KOLKATA 700 040 | KOLKATA | KOLKATA | WEST BENGAL | 700040 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.8 L+₹1.8 L (18.2%)Rejected-Finance 184 BHUPENDRA ROY ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance L2 | |
| 3 | L3₹11.9 L+₹1.9 L (19.4%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹12.6 L+₹2.6 L (25.9%)Rejected-Finance 131 NILMONI BHATTACHARJEE LANE KADAL BERHAMPORE MURSHIDABAD W B PIN 742102 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742102 | L4 | Rejected-Finance L4 | |
| 5 | L5₹13.5 L+₹3.5 L (35.2%)Rejected-Finance 119 MANAHAR PUKUR ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹28,512
Closing Date
7 Sept 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
O/o The EE_KNED, PWDte, P-5, CIT Road, 2nd Floor, Moulali, Kolkata-700 014.
Electrical installation works in between LT Meter and LT Distribution Panel Board at the newly constructed Clinical cum Academic Building of WBUAFS.
2022_WBPWD_395861_1
WBPWD/EE/KNED/NIT-16/2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
WBUAFS, Belgachia
Please refer Tender documents.
4 documents required · 4 mandatory
₹28,512
14 Nov 2022
18 Aug 2022
9 Sept 2022
19 Aug 2022
7 Sept 2022
23 Aug 2022
Amount
Supply & delivery & Commissioning of L.T. hooder type Feeder Pillar board of size should be suitable for the bellow descriptions and approved by EIC, with canopy Floor mounted with maple arrangement having rigid & self supporting structure fabricated from 2 mm/ 3mm. thick CRCA sheet steel with M/S angle frame. The panel board consisting of the following switches. Bus Bar Section: 500V, 600A electrolyte grade Copper bus bar with vertical/ horizontal section of size 40x10 mm for per Phase RYB & 40x10 mm for neutral bars. Bus bar should be enclosed by sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on inside feeder pillar, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991). Bar for earth 25x6 Al. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. Painting: Paint will be powder coated, after cleaning, the surface shall be given a phosphate coating, nine tank process system, SIEMENS GREY, RAL-7035 Shed. Constructural Details: All incoming & outgoing panel gasketted Door at front. All doors shall have Panel lock Arrangement. Degree of Protection will be IP-56(Protected from high pressure water jets from any direction) .The panel shall be properly Gasketted to prevent ingress of dust & moisture & Remain. Busbar will be properly arrange & fixed by M.S. nuts & bolts On angle /flat iron frame base as per direction of E.I.C.The PANEL will be fabricated by 14 SWG. CRCA Sheet. The sheet steel thickness will be 2mm & Gland plate shall be 2/3mm thick.
Errection of Feeder Piller Box of above size on 10" brick padestal of 10" size should be appropriate according to the above Feeder Pillar and dimensions of the same approved be the EIC (minimum height 600mm bellow Goround level and 600mm above G.L) incl. sand cement plastering and neat cement finishing. Inside the brick padestalwill be filled up by loose sand where the incoming & outgoing cable will be rest.
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991), 4 bars, 415 V, 600 A, Dimension of Cu. bars [85mm long] 4 x (2x 40x5) mm, Dimension of Sheet Metal Box 500x150mm.
Supplying and fixing 415V,415A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. ( Make : L&T/ Havells/ HPL/ Standard )
Supply of 4 core 185 sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable (supplying cable in parallal run from meter room to panel borad). ( Make : Havells/ Polycab/ Phinolex )
Supplying of 90 mm dia HDPE PIPES PE-63, 4kgf/cm2 Make-supreme, type-SDR-21, ( Make- Supreme/ Hensel/ Harse ) or similar make
Excavation of soil and laying HDPE/GI Pipe for cable laying filling & ramming. (0.680x0.760xtotal length of HDPE pipe running through (WxDxL).
Laying only Cable above 50 sqmm but not exceeding 400 sqmm through existing RCC/ Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core.
Bituminious Road cutting by using Jac Hamour Compressor Machine, Fuel, Mobile, Compressor Operator and Three Breaker.
Supply and Drawing of 70 sqmm copper wire single core FR PVC Insulated with Bright Annealed Copper Conductor for VoltageGrade 1100 Volts, with all necessary tie bar, flexible pipe and allied items, making necy. connection as required. ( Make : Havells/ Polycab/ Phinolex )
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/ PVC armoured cables as below.
4 core 185 sqmm.
Finishing the end of following XLPE/ PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
4 core 185 sqmm.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 70 sqmm.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming.For Soft Soil.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 4 SWG.
providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipeentry, for street light wiring, without Loop Box.
MODERN ELECTRIC
STANDARD BUILDERS
SANJIB GHOSH
UNITED CONSTRUCTION SERVICE
MAA TARA ENTERPRISE
S. A. ENTERPRISE
SILICON SOFTWARE
technical_776739.pdf
PDF • 0.73 MB
techsummary_776739.pdf
PDF • 0.72 MB
finance_776739.pdf
PDF • 0.73 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_776739.pdf
PDF • 0.47 MB
NIT-16.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .