| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹26.8 L+₹1.2 L (4.52%)Rejected-Finance | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹27.0 L+₹1.3 L (5.06%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹27.0 L+₹1.3 L (5.06%)Rejected-Finance 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹30.3 L+₹4.6 L (18.1%)Rejected-Finance AT POST SONAJ TAL MALEGAON DIST NASHIK | MALEGAON | NASHIK | MAHARASHTRA | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
3 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS TO ROOF WATER PROOF TREATMENT AND REPAIR OF SUNKEN FLOOR WALLS AND CHAJJA AT AUNDH MIL STN UNDER GE MH AND RH KIRKEE
2020_MES_392647_1
8147/E8
Open Tender
Civil Works
Item Rate
180 days
KIRKEE AND AUNDH
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH RH KIRKEE
₹70,000
Yes
22 Jan 2021
4 Nov 2020
4 Dec 2020
4 Nov 2020
3 Dec 2020
19 Nov 2020
4 Nov 2020 - 12 Nov 2020
60 days
Amount
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for and M & L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregates for filleting, benching, slightly rounding or chamfering on edges, filling undulations / depressions in roof surface, providing concrete platform for tanks wherever required as directed.
Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and disposal of the same to distance exceeding 50m but not exceeding 100m as and where directed and M & L for 15 mm thick screeding / rendering in cement mortar 1:4 on concrete roof surface, using Water Proofing Compound @ 3% by weight of cement, surface all as directed. Note: Water Proofing Compound shall be measured and paid separately.
Supply only intergral water proofing compound.
M & L for cleaning the plastered /concrete surface with wire brush and applying water proofing treatment as under:- (a) Apply a uniform coat of bituminus primer at 0.70 kg/sqm over cement plaster. (b) Providing and apply 3 mm thick and weighing not less than 3.6 kg/sqm Atactic Polypropylene Polymer (APP) modified bitumen - based prefabricated five layer water proofing membrane reinforced with non woven polyester matt black finished over compatible primer at 0.40 Ltr/sqm of density at 25 degree centigrade 0.87 - 0.89 kg/litre and viscosity 70-160 cps or cold sticker and torch application of membrane with 10 cm overlap both ways after necessary preparation of surface complete as per manufacturers instructions. (c) Apply two coats of bitumastic - aluminium paint over the membrane.
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for as directed.
M&L for waterproofing treatment to RCC sunken slab as specified below. Make: PIDILITE , Dr Fixit or equivalent:- (a) Clean the sunken portion of toilet/ Bath/ WC/Kitchen thoroughly to remove laitance, dirt , dust etc. (b) Form angle fillet of size 40 mm x 40mm along the junction of wall and floor using polymer modified mortar ("Dr Fixit" Pidicrete URP" or equivalent). (c) Sanitary pipes entering through walls and floor shall be sealed with " Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout " Dr Fixit Bathseal Gruot" or eqvt . Nahani traps , etc to be fitted securely and the gaps around it to grouted in the same manner. (d) Apply one coat of a Bitumen- modified polymer coating " Dr Fixit Bathseal Plus" or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. (e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproof coating " Dr Fixit Pidifins 2K" or eqvt can be further applied right upto 2.1 m to waterpoof the shower area also , if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours allow to dry completely. (f) After 2 to 3 days, sunken portion must be overlaid with a 50mm thick concrete screed M 15 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40mm OD UPVC pipe at the lowest point with 300mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2, all as specified and directed. (g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of appd makes such as Dr Fixit, FOSROC , SIKA, MC BUCHEMIE, ROFF etc , all as specified and directed.
M & L PCC (1:5:10) using 40mm graded aggregate as in mass concrete or as in sunken floor complete all as specified & directed
Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and M&L for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
Cleaning the surfaces of kitchen sunk (mori) with wire brush, detecting the sources of leakages and replacement of any defective fittings/fixtures of any type Imaterial like material like Nahani trap of 100 mm dia etc, sealing the joint of pipe/nahani trap with surrounding using PU sealant of Pidilite or equivalent, and M&L for replastering with 15mm thick in cement mortar 1:3 mixed with water proofing compound as per manufacturers instructions by providing slope at Nahani Trap'with good finishing all as specified and directed. Note :- The quoted rate shall be inclusive of cost of waterproofing compound, PU sealant and Nahani Trap.
Making hole and M&L for fixing thr metallic packer for hydrophobic PU foam and Sealer as per manufacturers specification. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. Make: PIDILITE or equivalent
Open the fittings like Y, bend, Tee etc from the outlet pipe filing properly the loose joint between bend and outlet pipe with solvent and fixing properly to ensure leakage free joint and making good
M&L for water proofing treatment of External walls DFT: 110 microns by applying two coats of elestromeric coating Raincoat, material covering capabity 3 Sqm per litre in 2 Coats without dilution & 1 coat of efflorescent resistant primer 10sqm/litre/coat after cleaning the surface throughly and sealing all cracks with acrylic sealing compound as per the manufacturers specifications and directions of Engr-in-Charge Make :- Raincoat shall be of PlDlLlTE or equivalent. The product shall have following properties: Elongation > 100% as per ASTM D 412, Tensile strength : 2.5 Mpa as per ASTM D 412, Water Resistance conforming to SS 500, Crack bridging ability conforming to Class A4 as per EN 1062 Part 7, Positive hydrostatic pressure > 7 bar as per DIN 1048, Anti-carbonation property complying EN 1062 Part 6, RCPT conforming to ASTM C 1202.
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tille with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, or equivalent , curing , cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
Cleaning the surfaces of existing RCC Slab with wire brush and M&L for application of one coat of CORE COAT LP (F) minimum 1mm thick (12 to 14Sqm per coat for 1mm thick coat per pack) or equivalent approved in PIDILITE and grouting with a coat of neat cement slurry using 2.70 Kg /Sqm of cement admixed with liquid water proofing admixture and one coat of SBR cement all as directed. Make :- Core coat shall be of Buildcore Chemical /or equivalent approved product of PIDILITE.
Cleaning the surfaces of existing RCC Slab with wire brush and M&L for application of 2 coats of Fastflex, minimum 1mm thick (1.5Kg/sqm) or equivalent approved in PlDlLlTE and grouting with cement slurry using expansive additive Pidicrete AM, @ 225gm/bag of cement and one coat of SBR latex all as directed. Make :- PIDILITE or equivalent, all as directed by Engineer-in-Charge.
MM&L for treating the dampness of wall with Siliconate injection grout (The spacing of holes shall be 2 Nos holes in every 1m) by making 12mm to 15mm holes at an inclination of 455 degrees to the extent of 112 to 3/4 of the wall thickness and inject the diluted chemical liquid (1 :4) (Min 10 Ltrs), in the lowest possible point by using a pressure grouting machine with a pressure of approximately 3 Kg/sqcm' till the point of return of liquid and seal the treated holes with suitable compound and washed thoroughly the treated areas with water all as directed.
Providing & applying 20mm thick (avg) waterproof screed plaster on vertical & horizontal RCC surface over the treated layer with CM (1:4) using cement sand mixed With waterproofing admixture LW+, make as approved by the Engineer, etc, complete, & trowel finish the surface as directed by the Engr-in-Charge followed by filling the water retaining structure, for 24 hrs to obtain water tightness test result.
M&L for cutting our cracks to V-section in existing roof or terrace, cleaning out, and filling solidly with a cement and clean dry sand 1:1 (by weight) , all as specified and directed.
M&L Cutting grooves, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, all as specified and directed.
S&F of factory made fiberglass reinforced plastics (FRP) CHHAJJA 4mm thick of requred colour, size and design made by Resin Transfer Moulding (RTM) machine technology, resulting in void free compact laminate in single piece, having smoothgradual slope all as specified and directed by Engr-in-Charge.
Dismantling water tanks and removing from site to directed place and S&F in repair rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part- I of capacity 500 ltrs all as specified and directed .
All as per item No 22 but of 1000 ltrs capacity all as specified and directed.
All as per item No 22 but of 2000 ltrs capacity all as specified and directed.
S&F in repair 20mm Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed.
Taking down cement plaster in any description incl racking out joints hacking for key and scrubbing down with water etc. Spd and directed by EIC
M & L 15 mm thick rendering on fair faces of brickwork / concrete surface on wall in CM 1:4 using WPC @ 3% by weight of cement, all as specified and directed Note:- WPC shall be measured seperately.
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM (1:3) with WPC, finished even and smooth without using extra cement all as specified and directed
M & L applying two coats of cement base paint to newly plastered surface of wall including preparation.
Demolition of cement concrete unreinforced in ground floors and paving n exc 15cm thickness (below or above ground level) as directed.
M & L for PCC 1:3:6 type C1 (uisng 20mm graded aggregate) 75 mm thick as in Plinth, Path, floor with fair finish surface with out using extra cement all as spd.
M& for Forming Contraction (Dummy) joints 75 mm deep x 10mm wide, filled with sealing compound complete all as specified and directed by EIC.
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
Supply & fixing steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified & directed by Engineer-in-charge.
All as per item No 34 above but Fixing only including new fittings all as specified and directed.
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
All as per item No 34 but 20mm bore pipe all as directed.
All as per item No 34 but 20mm bore pipe but Fixing only including new fittings all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises complete all as specified and directed.
M&L Coloured glazed ceramic tiles in vertical surface 300x450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including 10 mm thick backing coat in CM 1:4 all as directed.
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry to match the work using colour tiles over screed bed on bedding layer of mortar 15mm thick is CM 1:6 over cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in floors 25 mm thick, all as specified and directed.
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed.
Ditto all as per item No 42 above but as in dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1:4, set and jointed in neat white or coloured cement to match the surfaces of tiles all as specified and directed.
S & F in repairs water closet (Squat Pattern) complete incl provn of lime concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repair Vitreous China wash down water semi pedestal pattern (Anglo indian pattern) white (excluding fixing bolts flushing cistern) including flush pipe, seat cover suitable and connection to drain (or outgoing pipe) flushing pipe, anti-syphonage pipe complete , all as specified and directed.
S & F in repairs Plastic seat cover to EWC with aluminium hinging device all as specified and directed.
S & F in repairs Plastic seat cover suitable for anglo indian EWC with hinging device all as specified and directed.
S&F in repairs of CP wall mixer three-in-one with all connecting fitting including screws, bend, all as specified and directed.
S&F in repairs of Stack clamps for any bore of pipe out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends pof stays to wall or roof all as specified and directed.
S&F in repairs PVC (SWR) pipes 110 mm dia single sockets, in any length rubber ring joints, fixed to wall all as specified and directed.
S&F in repairs PVC (SWR) junction110mm bore single ( single t) equal or unequal all as specified and directed.
S&F in repairs PVC (SWR) 75 mm dia bends any radius all as specified and directed.
S&F in repairs PVC (SWR) junction 75 mm bore single ( single t) equal or unequal all as specified and directed.
S&F in repairs PVC (SWR) branch75 mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks of capacity of 500 liters and from mouths of circulating pipes, etc
Cleaning and removing all scale and dirt, etc, from tanks of capacity of 1000 liters and from mouths of circulating pipes, etc
S&F in repair PVC water tank cover with fitting suitable for tank of capacity of 500 liters etc including device complete.
S&F in repair PVC water tank cover with fitting suitable for tank of capacity of 500 to 1000 liters etc including device complete.
S&F in repairs Cast iron soil 100 mm bore , waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors all as specified and directed.
S&F in repairs Cast iron floor trap 100 mm bore with grating including jointing to waste pipe and fixed with PCC 1:2:4, all as specified and directed.
S&F in repairs Cast iron bend 100 mm size with duck's foot or heelrest , all as specified and directed.
S&F in repairs Cast iron bend 75 mm size with duck's foot or heelrest , all as specified and directed.
S&F in repairs Cast iron branch piece single 100 mm bore with duck's foot or heelrest all as specified.
S&F in repairs Cast iron branch piece single 75 mm bore with duck's foot or heelrest all as specified
S&F in repairs Cast iron soil 75 mm bore , waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors, all as specified and directed.
Disconnecting existing tanks size exc 250 and n exc 500 ltr capacity , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately).
Disconnecting existing tanks size exc 500 and n exc 1000 ltr capacity , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately).
Disconnecting existing tanks size exc 1000 and n exc 2000 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately).
Dismantling of existing EWC and refxing the same after treatment of sunken floor complete.
C J Enterprises
visionenterprises
ANJALI CONSTRUCTIONS
MAHESH DADAJI BACHHAV
S.R.M.K Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .