| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H4₹1.5 CrAccepted-AOC RAILWAY COLONY NOWGAM SRINAGAR JAMMU AND KASHMIR 190015 | BUDGAM | JAMMU AND KASHMIR | 190015 | ₹1.5 Cr | H4 | Accepted-AOC Accepted being lowest as per NIT |
| 2 | H1₹2.0 CrRejected-Finance | ₹2.0 Cr | H1 | Rejected-Finance Rejected being H1 bidder |
| 3 | H2₹1.7 CrRejected-Finance | ₹1.7 Cr | H2 | Rejected-Finance Rejected being H2 bidder |
| 4 | H3₹1.5 CrRejected-Finance LINK FIRST NEW AIRPORT ROAD NEAR TATA ENGINEERING GARAGE PO HUMAMA SRINAGAR 190014 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190014 | ₹1.5 Cr | H3 | Rejected-Finance Rejected being H3 bidder |
| Sl No | Description | Qty | Unit | M/S SHAH CONSTRUCTION H3 | AHMED CONSTRUCTIONS AND INFRA PVT LTD H4 | ALCO ENGINEERSPVT LTD H2 | M/S ALBURAQ INFRATECH PRIVATE LIMITED H1 |
|---|---|---|---|---|---|---|---|
| 1.00LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS | |||||||
| 2.00 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part -I brought forward from serial page No. 26 | 1 | Lump sum | 94,00,000 ₹94 L | 88,00,000 ₹88 L | 76,50,000 ₹76.5 L | 1,15,00,000 ₹1.1 Cr |
| 3.00 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' (Part-II Section-I) brought forward from serial page No. 27 | 1 | Lump sum | 80,000 ₹80,000 | 70,000 ₹70,000 | 2,00,000 ₹2 L | 1,30,000 ₹1.3 L |
| 4.00INTERNAL ELECTRIFICATION WORKS Schedule 'A' (Part-II Section-II) | |||||||
| 4.01 | Flameproof MCB Distribution Board , SPN 4 way 230volts , Cast Aluminum Alloy LM6, gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection , all as specified. | 6 | EACH | 5,000 ₹30,000 | 3,000 ₹18,000 | 50,000 ₹3 L | 2,500 ₹15,000 |
| 5.00 | Lump sum price worked out by the contractor for PROTECTIVE WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 28 | 1 | Lump sum | 7,40,000 ₹7.4 L | 9,50,000 ₹9.5 L | 13,00,000 ₹13 L | 14,00,000 ₹14 L |
| 6.00 | Lump sum price worked out by the contractor for LIGHTING PROTECTION WORKS as listed in Schedule 'A' (Part-IV) brought forward from serial page No. 29 | 1 | Lump sum | 75,000 ₹75,000 | 65,000 ₹65,000 | 2,30,000 ₹2.3 L | 1,00,000 ₹1 L |
| 7.00 | Lump sum price worked out by the contractor for ROAD AND HARD STANDING WORKS as listed in Schedule 'A' Part-V brought forward from serial page No.30 to 31. | 1 | Lump sum | 20,00,000 ₹20 L | 20,25,000 ₹20.3 L | 34,50,000 ₹34.5 L | 34,00,000 ₹34 L |
| 8.00 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule 'A' Part-VI brought forward from serial page No. 32 | 1 | Lump sum | 4,39,378.74 ₹4.4 L | 4,00,000 ₹4 L | 7,00,000 ₹7 L | 6,00,000 ₹6 L |
| 9.00 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS listed in Schedule 'A' Part-VII section -I brought forward from serial page No.33 | 1 | Lump sum | 15,000 ₹15,000 | 17,000 ₹17,000 | 4,00,000 ₹4 L | 23,000 ₹23,000 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
5 Apr 2025, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS, PIN 914133, C/O 56 APO
CWEK/TOKEN-68/874 EWS/2024-25- PROVN OF 01XWP SHED AND ALLIED STRUCTURE AT CHAKIGAM UNDER GE 874 EWS AND JOB NO- 31SA/MAJ WK/AMWP-02/2023-24
2024_MES_679506_3
CWEK/TOKEN-68/874 EWS/2024-25
Open Tender
Civil Works
270 days
GE 874 EWS
Class B and above and category a i
7 documents required · 7 mandatory
₹1,000
GE 874 EWS
₹1.9 L
HQ 133 WORKS ENGRS
20 Jun 2026
8 Mar 2025
12 Apr 2025
8 Mar 2025
5 Apr 2025
22 Mar 2025
8 Mar 2025 - 11 Mar 2025
13 Mar 2025
Amount
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part -I brought forward from serial page No. 26
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' (Part-II Section-I) brought forward from serial page No. 27
INTERNAL ELECTRIFICATION WORKS Schedule 'A' (Part-II Section-II)
Flameproof MCB Distribution Board , SPN 4 way 230volts , Cast Aluminum Alloy LM6, gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection , all as specified.
Lump sum price worked out by the contractor for PROTECTIVE WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 28
Lump sum price worked out by the contractor for LIGHTING PROTECTION WORKS as listed in Schedule 'A' (Part-IV) brought forward from serial page No. 29
Lump sum price worked out by the contractor for ROAD AND HARD STANDING WORKS as listed in Schedule 'A' Part-V brought forward from serial page No.30 to 31.
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule 'A' Part-VI brought forward from serial page No. 32
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS listed in Schedule 'A' Part-VII section -I brought forward from serial page No.33
EXTERNAL WATER SUPPLY WORKS Schedule 'A' (Part-VII Section-II)
M&L for cutting of existing steel tubing 80mm dia for alterations or additions for making branch connection as inserting the tee of size 80x80x25mm size and union 80mm etc including threading and fitting etc complete all as specified and directed.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS listed in Schedule 'A' Part-VIII section -I brought forward from serial page No. 34 to 35
EXTERNAL ELECTRIFICATION WORKS Schedule 'A' (Part-VIII Section-II)
M&L earthing complete with and including galvanised steel earth plate electrode 60x60cmx6mm thick surrounded by mixture of charcoal and salt in alternate layers, bured directly in ground vertically in a pit of depth not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron or steel earth load wire 4.0mm dia (No 8 SWG) by means of bolts, nuts check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15mm bore (light grade) and connected to main switch or main control board or junction box all as shown in electrical plate No 3 of SSR 2009 Part-I & including necessary excavation and earth work. Note: - The rate also include charcoal and salt in alternate layers, 20mm bore GI pipe (light grade) for watering, protection pipe funnel, wire mesh, PCC 1:2:4 type B1 chamber in cement concrete 50mm thick precast RCC cover duly reinforced with XPM (weight not less than 3kg/sqm) and CI frame etc and including provision of test point, connecting to test point and testing on completion etc complete all as specified.
M&L for earthing complete with galvanised steel earth plate electrode of size 60x60cm thick surrounded by mixture of charcoal and salt in alternate layers, buried directly in ground vertically in a pit of depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level, connected to equipment by using GI strips of size 32x6mm as earthing lead by means of bolts, nuts check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES schedule and connected to earthing test point all as specified and directed including earth pit of size 30cmx30cm x45cm made of PCC 1:3:6 and PCC 1:2:4 cover, funnel GI tubing etc & testing on completion all as specified. Note:- The unit rate includes the cost of excavation & earth work in any type of soil, charcoal and salt in alternate layers, 20mm bore GI Pipe (med grade) for watering 40mm GI protection pipe (light grade) funnel, wire mesh, lugs PCC 1:2:4 type B1 chamber in cement concrete 50mm thick precast RCC M-25 (design mix) cover duly reinforced with XPM (weight not less than 3kg/sqm) and CI frame etc and including provision of test point, connecting to test point and testing on completion etc complete all as specified. The unit rate also include earthing lead and protection pipe upto 7.5 mtr from top of earth plate
S&F 60 watt IP 65 LED street light luminaries comprising of rectangular shape pressure dia cast housing with weather proof gasket for lamps and driver compartment with system wattage 60 watts+/- and rated lumens of min 500 lumens. The LED make must be of. The driver must be constant current type having THS 15% and power factor 0.95 with short circuit protection against 5 KV high surge and comply to IC60598/IS 10322 (PT 0.5 sec) 1987. The luminaries must have sec optics with perfectly matched lens for better light control complete all as specified and directed.
Supply & fixing street light Engineering plastic one piece moulding control box with locking arrangement made out of HDPE and FI clamp 25x3mm complete of dimensions in CM +/-10%(34x28x13) including MCB SP 6 Amp 240 volts complete with 02 Nos aluminium busbar or terminal 02 Nos (2P-RYB and N) of rating 63 Amps for single phase and neutral on porcelain based insulators complete all as specified and directed. Make;- Sintex/Hensel/SHI/BRITE.
S&F GI bracket made out of GI pipe light grade of size 32 mm dia 1.2 m long out to length bend to the required shape and 02 Nos mounting flat iron clamps size 40mmx 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers complete all as specified and directed.
M&L for multistranded copper conductor heavy duty cable PVC insulated conductor, served with inner sheathing of PVC tape and overall PVC sheathed of size 2.5sqmm 3 core for street light connection complete all as specified and directed.
S&F MCCB enclosure ‘A’ frame, 200 Amps bus bar capacity, 4 pole complete all as specified Make- HAVELLES CAT PART No IHEAFP or Equivalent.
S&F MCCB 40 Amps 4P, 415 volts breaking capacity 16KA adjustable thermal and fixed magnetic release complete all as specified and directed.
SMOKE DETECTOR WORK Schedule 'A' (Part-IX)
Detectors complying with and type certified to EN 45 addressable type multi sensor detector with heat and smoke combination including with all standard fittings and jointing material connecting with electrical system/ remote system testing and commissioning after fixing the detector, as per IS: 11360 complete all as specified and ducted by engineering charge
Lump sum price worked out by the contractor for SITE DEVELOPMENT & EARTHWORK as listed in Schedule 'A' Part-X brought forward from serial page No.36
ALCO ENGINEERSPVT LTD (BID ID -3273073)
M/S SHAH CONSTRUCTION (BID ID -3270376)
AHMED CONSTRUCTIONS AND INFRA PVT LTD (BID ID -3277149)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
Tender68.pdf
Tender Documents • 2.31 MB
BOQ_784876.xls
BOQ • 0.34 MB
NewDrg68.pdf
Additional Documents • 24.20 MB
Download all tender documents and submit your bid