Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹46.9 L+₹3.5 L (7.96%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected due to OEM cert has not uploaded | |
| 4 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Rejected due to OEM cert has not uploaded | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to OEM cert has not uploaded |
| Sl No | Description | Qty | Unit | RUCHIKA ENGG.WORKS L2 | SNOWY ENGINEERING INC L1 |
|---|---|---|---|---|---|
| 1.00 | Servicing of Window type AC 1.5/2 Ton capacity of any make/model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed.
Note: The quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape | 10 | Each Job | 250 ₹2,500 Lowest | 500 ₹5,000 |
| 2.00 | All as per item No 1.00 above but Split type AC of any type and 1.5/2 Ton capacity complete all as specified and directed. | 48 | Each Job | 350 ₹16,800 Lowest | 550 ₹26,400 |
| 3.00 | S&F in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 Volt for AC upto 4.00 Ton complete all as specified and directed. | 30 | Each | 350 ₹10,500 Lowest | 430 ₹12,900 |
| 4.00 | S&F in repairs running capacitor upto 100 mfd 230 Volt complete all as specified and directed. | 4 | Each | 250 ₹1,000 Lowest | 300 ₹1,200 |
| 5.00 | S&F in repairs Starting relay suitable for upto 4.0 Ton capacity AC complete all as specified and directed.
Make : Renutrol/Classic/Indfos. | 11 | Each | 150 ₹1,650 Lowest | 650 ₹7,150 |
| 6.00 | S&F in replacement over load protector suitable for upto 4.0 TR capacity AC any type complete all as specified and directed.
Make : Renutrol/Classic/Hitech. | 11 | Each | 175 ₹1,925 Lowest | 400 ₹4,400 |
| 7.00 | M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/32/134a for Split type/Window type AC any size any capacity as on site complete all as specified and directed by Engr-in-Charge. | 10 | Each Job | 2,000 ₹20,000 | 900 ₹9,000 Lowest |
| 8.00 | Supply & charging gas refrigerant R-22/R-32/410A or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified and directed by Engineer-in-charge | 80 | Kg | 2,000 ₹1,60,000 | 1,250 ₹1,00,000 Lowest |
| 9.00 | M&L for repair of unserviceable PCB suitable for Non-Inverter Split type AC 1.5/2 TR and fixing the same complete all as specified and directed by Engineer-in-charge. | 6 | Each Job | 2,000 ₹12,000 | 1,500 ₹9,000 Lowest |
| 10.00 | M&L for opening and taking down existing unserviceable PCB along with display unit and repairing & fixing of PCB along with display unit suitable for Indoor unit of Inverter AC of capacity1.5/2 Ton Split type AC complete all as specified and directed by Engr-in-Charge. | 3 | Each Job | 2,500 ₹7,500 Lowest | 7,500 ₹22,500 |
Tender Value
Refer Docs
EMD Value
₹89,982
Closing Date
9 Aug 2025, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/ MAINT OF VRF, ACs (WINDOW/ SPLIT/ CASSETTE TYPE) AT NDC, REPAIR/ MAINT OF COOLING APPLIANCES SUCH AS WATER COOLER, REFRIGERATOR AND ACs AT AHQ CAMP LODHI ROAD ECHS POLYCLINIC LODHI ROAD AND REPAIR/ MAINT OF DG SETS, LT PANEL, LT UG CABLES,
2025_MES_720117_1
NIT No GE/ND-35/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NEW DELHI
₹89,982
Yes
22 Sept 2025
12 Jul 2025
11 Aug 2025
12 Jul 2025
9 Aug 2025
26 Jul 2025
Amount
Servicing of Window type AC 1.5/2 Ton capacity of any make/model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed. Note: The quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape
All as per item No 1.00 above but Split type AC of any type and 1.5/2 Ton capacity complete all as specified and directed.
S&F in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 Volt for AC upto 4.00 Ton complete all as specified and directed.
S&F in repairs running capacitor upto 100 mfd 230 Volt complete all as specified and directed.
S&F in repairs Starting relay suitable for upto 4.0 Ton capacity AC complete all as specified and directed. Make : Renutrol/Classic/Indfos.
S&F in replacement over load protector suitable for upto 4.0 TR capacity AC any type complete all as specified and directed. Make : Renutrol/Classic/Hitech.
M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/32/134a for Split type/Window type AC any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
Supply & charging gas refrigerant R-22/R-32/410A or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified and directed by Engineer-in-charge
M&L for repair of unserviceable PCB suitable for Non-Inverter Split type AC 1.5/2 TR and fixing the same complete all as specified and directed by Engineer-in-charge.
M&L for opening and taking down existing unserviceable PCB along with display unit and repairing & fixing of PCB along with display unit suitable for Indoor unit of Inverter AC of capacity1.5/2 Ton Split type AC complete all as specified and directed by Engr-in-Charge.
M&L for opening and taking down existing unserviceable PCB along with display unit and repairing & fixing of PCB along with display unit suitable for outdoor unit of Inverter AC of capacity1.5/2 Ton split type AC complete all as specified and directed by Engr-in-Charge.
S&F in replacement PCB of non inverter type split type AC of capacity 1.5 to 2.0 Ton and fixing the same in respective units including opening & taking down existing unsv PCB complete all as specified and directed by Engineer-in-charge.
S&F in replacement PCB of inverter type split type AC of capacity 1.5 to 2.0 Ton and fixing the same in respective units including opening & taking down existing unsv PCB complete all as specified and directed by Engineer-in-charge.
S&F in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 TR as per sample complete all as specified and directed.
Supply only in replacement cordless Remote for inverter type ACs suitable for 1.5 Ton AC as per sample complete all as specified and directed.
Supply only in replacement cordless Remote for Non-Inverter ACs suitable for 1.5/2 ton Split/Window AC as per sample complete all as specified and directed.
S&F in replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape complete all as specified and directed.
S&F in repair condensing coil suitable for 1.5/2 Ton Split/Window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
S&F in repair evaporating coil suitable for 1.5/2 Ton Split/window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
S&F in replacement reciprocating /Rotary type compressor suitable for 1.5 to 2.0 Ton capacity inverter/non inverter split type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engg in charge.
S&F in replacement reciprocating/Rotary type compressor suitable for 1.5 to 2 Ton capacity window type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
S&F in replacement of three phase compressor suitable for VRF units of 20 HP capacity suitable of cassete /tower AC of the same make and model as per existing make of ACs complete all as specified and directed.
S&F in replacement of three phase compressor suitable for VRF units of 28 HP capacity suitable of cassete /tower AC of the same make and model as per existing make of ACs complete all as specified and directed.
S&F in replacement of indoor unit kit suitable for split type AC 1.5/2 Ton with PCB complete with sensor complete with fixing plate suitable to non inverter type AC complete all as specified and directed.
S&F in replacement of split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condensor coil, condensor fan with blade and sensor suitable to non inverter type existing model and make AC complete all as specified and directed by Engg in charge.
S&F in replacement new fan motor (inoor/outoor) upto 1/4 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
S&F in replacement new DC fan motor (inoor/outoor) upto 1/4 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
S&F in replacement fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton AC's of any make/type complete as per requirement on site complete all as specified and directed.
S&F in replacement new DC fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton cassatte type AC's of any make/type complete as per requirement on site complete all as specified and directed.
S&F in replacement air direction changer louver motor ( swing motor) suitable for split type ACs as per existing make and model complete all as specified and directed.
M&L for rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft complete all as specified and directed.
S&F in replacement condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity window type Acs complete all as specified and directed.
S&F in replacement of condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton Split AC capacity complete all as specified and directed.
S&F in replacement of evaporating air blower made out of aluminium /plastic suitable for upto 2 Ton capacity for window type AC complete all as specified and directed.
S&F in replacement of evaporating air blower made out of aluminium /plastic suitable for upto 2 Ton capacity for split type AC complete all as specified and directed.
S&F in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 2.5 sqmm complete all as specified and directed.
S&F in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 4.0 sqmm complete all as specified and directed.
S&F in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 6.0 sqmm complete all as specified and directed.
M&L for Repair to control processing board (Remote control kit) with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and directed.
M&L for Repair to control processing board (Remote control kit) inverter type with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete for 3.5/4 Ton cassette type ACs of any make & model complete all as specified and directed.
S&F in replacement voltage stablizer of capacity 3 to 5 KVA ,copper wounded made of metalic body complete all as specified and directed.
S&F in replacement Metal Clad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz complete all as specified and directed.
S&F in replacement modular AC board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz complete all as specified and directed.
S&F in replacement of plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified and directed.
Labour for checking and attending complants of ACs of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed. Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in NDC and he must submit copy of valid competency certificate of two (2) AC mechanics each having minimum working experience of two years in the field of air conditioning & refrigeration. The certificates shall be issued by the OEM only stating the technical qualification & experience of the mechanics to be deployed, and these certificates to be uploaded on portal at the time of bidding and submit a physical copy in the office of GE, failing which bid of the contractor is liable to be rejected. The said certificates shall also forwarded by OEM through mail on e-mail id [email protected] (b) The complaint should be attended on same day within 3 hours . (c)) If the complaint not attended/not completed on same day within three hours recovery will be done as follows:- (i) For first day Rs.500/- (ii) For second day Rs.800/- (iii) For next every day Rs.1000/-
Comprehensive maintenance and servicing of entire VRF units (Two Nos of 24 HP Each and Two Nos of 28 HP Each) once in a month, total capacity 48 HP installed at Kautilya Hall and total capacity of 56 HP installed at Dining Hall including replacement of PCB kit of indoor units fan motor, compressor as per existing , brazing to joints. gas top up, repair to display along with connected accessories, short circuiting of wiring rectification and its replacement, including repair/ replacement to LCD display servicing or descaling of cooling fins and removal of dirt by pressure washing etc complete all as specified and directed by Engineer-in-charge. Note: Entire work shall be carried out by OEM /OEM authorised dealer
Comprehensive maintenance and servicing of entire VRF units One No of 28 HP & One No of 12 HP) once in a month capacity, total capacity 40 HP installed at NDC Library including replacement of PCB kit of indoor units (04 Nos ) fan motor, compressor as per existing , brazing to joints. gas top up, repair to display along with connected accessories, short circuiting of wiring rectification and its replacement, including repair/ replacement to LCD display servicing or descaling of cooling fins and removal of dirt by pressure washing etc. It comprises 04 Nos indoor unit complete all as specified and directed by Engineer-in-charge. Note: Entire work shall be carried out by OEM /OEM authorised dealer
Comprehensive maintenance and servicing of entire VRF units One No of 24 HP and One No of 16 HP) once in a month total capacity 40 HP installed at Hunt Lodge and Anchor Bar including replacement of PCB kit of indoor units (07 Nos ) fan motor, compressor as per existing , brazing to joints. gas top up, repair to display along with connected accessories, short circuiting of wiring rectification and its replacement, including repair/ replacement to LCD display servicing or descaling of cooling fins and removal of dirt by pressure washing etc. It comprises 07 Nos indoor unit complete all as specified and directed by Engineer-in-charge. Note: Entire work shall be carried out by OEM /OEM authorised dealer
Taking down AC of any type, any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repair work, transportation back to location of installation, reinstallation/ refixing in position after complete repairs as required and making functional including testing complete all as specified and directed.
M&L for taking down Split/ Window AC and shifting from one position to other within the premises Complete with copper tubing indoor plate and copper tubing complete with all accessories with making good the disturbed surfaces with cement plaster and POP complete all as specified and directed by Engr-in-Charge.
M&L for making suitable hole in the wall to fix window or split AC and maintain the surface as per existing condition completet all as pecified and directed. Note : (a) Plastering, Putty, Painting includede in the quoted rate (b) Covering the window by plywood if nececssary also included in the quoted rate.
S&F in replacement wall stand /chauki stand fastener upto 8 mm size to fix outdoor of split/cassette AC made of Mild Steel duly painted complete all as specified and directed.
Labour for checking and attending complants of Water Coolers, ACs and Refrigerators of any capacity, rectification of minor defects and making the equipment functional to the satisfaction of Engr-in-Charge complete all as specified and directed. Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in AHQ Camp Lodhi Road and ECHS Polyclinic Lodhi Road and he must submit copy of valid competency certificate of two (2) AC mechanics each having minimum working experience of two years in the field of air conditioning & refrigeration. The certificates shall be issued by the OEM only stating the technical qualification & experience of the mechanics to be deployed, and these certificates to be uploaded on portal at the time of bidding and submit a physical copy in the office of GE, failing which bid of the contractor is liable to be rejected. The said certificates shall also forwarded by OEM through mail on e-mail id [email protected] (b) The complaint should be attended on the same day within 3 Hours of reporting. (c) If the complaint not attended/not completed on same day within three hours recovery will be done as follows:- (i) For First day Rs.500/- (ii) For Second day Rs.800/- (iii) For Every Next Day Rs.1000/-
Supply & Charging gas refrigerant suitable for Split type AC up to 2 Ton capacity including removing of leakage if any and testing complete all as specified and directed by Engineer-in-charge
S&F in replacement of thermostat switch suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity ACs complete all as specified and directed.
S&F in replacement of air filter Synthetic/Nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type Acs complete all as specified and directed.
Servicing and gas charging of Refrigerator 265 Litres capacity including cleaning of parts, replacment of minor parts if required, replacement of filters, leakage testing complete all as specified and directed.
S&F in replacement of compressor suitable for 265 Litres refrigerator complete with required accessories and make as per sample complete all as specified and directed.
Servicing and gas charging of Water cooler cap 80 Litres including cleaning of parts, replacment of minor parts if required ,replacement of filters ,leakage testing complete all as specified and directed.
S&F in replacement of compressor of 80 Litres water cooler complete with required accessories and make as per sample complete all as specified and directed.
S&F in replacement of voltage stabilizer variation 170 to 250 volt cap 2KVA completet set and make as per sample complete all as specified and directed.
S&F in replacement of voltage stablizer cap 5 kVA suitable for AC 1.5/2 Ton, variation of input 140 to 300 Volts and output from 215 to 240 Volts completet set, make as per sample complete all as specified and directed.
S&F in replacement Desert Cooler steel body 60 Litres capacity complete set with water pump, Fan Motor, Blades all as specified and directed, including MS stand to mount the cooler (Required to maintain the temperature inside the substation equiped with Transformer) complete all as specified and directed.
M&L for Preventive maintenance of DG sets (75kVA x 01, 62.5kVA x 1 ,125kVA x 01) on quarterly basis installed at NDC. The following maintenance to be carried out complete all as specified and directed as under: a) Checking levels of Oil in Fuel Tank Coolant, Gauge Valve and replenish if necessary b) Re-grease all grease points c) Tightening of Nut-Bolts of pipeline of fuel oil, lubricating oil, water and check for any leakages. d) Check the Water level in Radiator and Top Up the coolant as required e) Clean Oil Filters/Fuel Filters. f) Check Viscosity of Lube Oil. g) Check Crank case for leakage. h) Cleaning Air Filters. i) Check the Radiator fan belt condition. j) Check Distilled water for Battery and Top-up. k) Check Battery cover condition from cover and Battery Voltage. l) Check the Metering equipment. m) Check the Insulation resistance of alternator.
M&L for "B" Check of DG set of 62.5 KVA capacity by taking out unsv spares, adjustment belt tension,Tuning of Engine, adjustment of speed, alternator voltage, check the serviceability of AVR, frequency etc, greasing oiling and changing oil, oil filter, fuel filter, bypass filter, Air filter, Water separator and Radiator cleaning with chemical For smooth functioning of DG Set complete all as specified and directed by Engg in charge. Note: Any spares, Engine oil, Coolant, Unserviceable spares required to be replaced shall be measured and paid separately under respective items
All as per item No 70.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 70.00 above but for 125 kVA DG Set complete all as specified and directed.
M&L for Servicing of Generator AMF Panel of 62.5 KVA DG Set complete including labour for replacement of u/s spares, testing complete all as specified and directed. Note: unserviceable spares required to be replaced shall be measured paid for separately under respective items
All as per item No 73.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 73.00 above but for 125 kVA DG Set complete all as specified and directed.
Supply only in replacement of Fan belt suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
All as per item No 76.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 76.00 above but for 125 kVA DG Set complete all as specified and directed.
Supply only in replacement of Diesel Filter suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
All as per item No 79.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 79.00 above but for 125 kVA DG Set complete all as specified and directed.
Supply only in replacement of Oil Filter suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
All as per item No 82.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 82.00 above but for 125 kVA DG Set complete all as specified and directed.
Supply only in replacement of Air Filter suitable for 62.5 KVA of DG Set as per existing complete all as specified and directed by Engr-in-Charge.
All as per item No 85.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 85.00 above but for 125 kVA DG Set complete all as specified and directed.
Supply only in replacement of Temperature Gauge suitable for 62.5 KVA DG Set as per complete all as specified and directed by Engr-in-Charge.
All as per item No 88.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 88.00 above but for 125 kVA DG Set complete all as specified and directed.
Supply only in replacement of Lube Oil Pressure Gauge suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
All as per item No 91.00 above but for 75 kVA DG Set complete all as specified and directed.
All as per item No 91.00 above but for 125 kVA DG Set complete all as specified and directed.
Supply only Coolant of approved make as per OEM in sealed containers complete all as specified and directed.
Supply only Synthetic Engine Oil (Type : SAE 20W40) of approved make as per OEM in sealed containers complete all as specified and directed.
M&L for as in repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing u/s parts re-assembling the pump after repair/ replacement of parts and testing by caliberation as per sample of Cap 62.5 - 125 kVA complete all as specified and directed.
M&L for taking down and servicing of radiator assembly and replacement of minor parts, de-scaling of tubes with chemical solution, welding/brazing leak testing including transportation to workshop and re-fixing after repairs and testing commissioning for DG set 62.5 to 75 KVA capacity complete all as specified and directed by Engr-in-charge.
All as per item No 97.00 above but for DG Set 125 kVA Capacity complete all as specified and directed.
S&F in replacement of maintenance free Tubular Battery 12V, 180 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge.
S&F in replacement of maintenance free Tubular Battery 12V, 150 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge.
S&F in replacement of Battery lead copper conductor of size 50 Sqmm multistranded PVC insulated with suitable terminals at both ends of required length for each battery complete all as specified and directed.
M&L for repair of self starter with replacament of carbon bushes, pinion, rewinding of stator and rotor winding with approved quality of winding wire as per existing and replacement of defective parts to make the starter fully functional and commissioning and testing of DG set of any type and capacity complete all as specified and directed by Engr-in-Charge.
S&F in repair Battery Lugs/Connectors of suitable capacity as per the site complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Hose Pipe Set suitable for 62.5 to 75 KVA DG sets complete all as specified and directed.
All as per item No 104.00 above but for 125 kVA DG Set complete all as specified and directed.
M&L as in repairs to DG Set Control Panel of capacity 62.5 - 75 kVA incl replacement defective sensors like AMF module, relay card/board, current transformer, Key switch , Indicators, Warning, Push button and checking control wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge
M&L as in repairs to DG Set Control Panel of capacity 125 kVA incl replacement defective sensors like AMF module, relay card/board, current transformer, Key switch , Indicators, Warning, Push button and checking control wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge.
S&F in replacement of Battery Charger of 6 Amps rating 12V Battery complete all as specified by directed by Engr-in-Charge.
M&L for preparing old rusted surface of DG sets by thoroughly cleaning the surface to remove dust, rust flakes, paint flakes using wire brush or sand paper, primimg the affected surface with anti-corrosive primer and applying paint using suitable sprayer to get a smooth glossy surface finish and writing MES Number of DG Set (both Engine and Alternator) at existing site in Block capital letters complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning in replacement of 250 Amp, four pole on load changeover in the existing enclosure with proper grouting of the same on walls with fastners complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning in replacement of 200 Amp, four pole on load changeover in the existing enclosure with proper grouting of the same on walls with fastners complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Street light fitting 45 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed. Make : Havells/CG/Philips.
S&F in replacement of LED Street light fitting 60 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed. Make : Havells/CG/Philips.
S&F in replacement of LED Building security light fitting 25 Watt including GI bracket of suitable size, fixing with clamp, nut, bolt and other connected accessories complete all as specified and directed. Make : Havells/CG/Philips
S&F in replacement IP66/67 (as per IEC 60529) Thermoplastic PC- GFS Polycarbonate Weatherproof, UV resistant due to solar radiation, Rainwater proof, temperature resistant, Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C (as per IEC 60695 – 2 – 11) Junction Box having size (205x255x112 mm) (Make: Hensel Cat Part No KF 2525G of Hensel or Equivalent in Rittal/ABB/Siemens) on existing Pole with 1 No. 6 Amp 'B' Curve series, 10kA SP MCB i/c supply with pole mounting kit for clamping the box on pole, earthling the body connection, inter- connection, suitable terminal blocks, glands, locknut etc. complete set as reqd. for Pole lighting complete all as specified and directed by Engg in charge.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc. including taking down old unsv earthing any type complete all as specified and directed.
S&F in repair Earth continuity conducto of size 25x4 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
S&F in replacement power capacitor 3 phase 25 kVAR of rated current 32.8 amp complete all as specified and directed by Engr-in-Charge
S&F in replacement MCCB 4-Pole, 415 V, adjustable type 63 Amps with breaking capacity 16 kA complete all as specified and directed.
S&F in replacement MCCB 4-Pole, 415 V, adjustable type 100 Amps with breaking capacity 36 kA complete all as specified and directed.
S&F in replacement MCCB 4-Pole, 415 V, adjustable type 160 Amps with breaking capacity 36 kA complete all as specified and directed.
S&F in replacement MCCB 4-Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 kA complete all as specified and directed.
S&F in replacement MCCB 4-Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 kA complete all as specified and directed.
S&F in replacement MCCB 4-Pole, 415 V, adjustable type 400 Amps with breaking capacity 36 kA complete all as specified and directed.
M&L for servicing and calibration of APFC relay panel of capacity 275 KVAR including replacement of minor faults, push button switch, wiring etc complete in all respect as per the direction of Engr-in-charge.
M&L for servicing and calibration of APFC relay panel of capacity 200 KVAR including replacement of minor faults,push button switch,wiring etc including taking out old u/scomplete in all respect as per the direction of Engr-in-charge.
S&F in repair of aluminium lugs of size 16/25 sq mm complete all as specified and directed by Engr-in-Charge
S&F in repair of aluminium lugs of size 35/50sq mm complete all as specified and directed by Engr-in-Charge
S&F in repair of aluminium lugs of size 70/95 sq mm complete all as specified and directed by Engr-in-Charge
S&F in repair of aluminium lugs of size 120/150 sq mm complete all as specified and directed by Engr-in-Charge
S&F Current transformer of 60:30/5+5 fixed in ACB panel of protection class 5P10 & metering clss -01 completeincluding taking out old u/s complete all as specified and directed by Engr-in-Charge
M&L for servicing servo voltage stablizer 200 KVA including replacement of minor complete in all respect as per the direction of Engr-in-charge.
M&L for disconnecting power supply from Air Circuit Breaker of capacity 630 Amps, taking out trolley unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part ,tightening/cleaning of CTs, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley , checking proper operation of trolley all as directed, inserting trolley inside and testing, and putting on load complete all as specified and directed.
S&F in repair Cable jointing kit for 1100 volt complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm complete all as specified and directed by Engr-in-Charge
S&F in repair Cable jointing kit for 1100 volt complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed by Engr-in-Charge
S&F in repair Cable jointing kit for 1100 volt complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
S&F wire meshed Hot dip Galvanized cable tray 54mm (h) x 200 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable,LAN /signal cable ,if require through wall cutting and making to good surface in distrubed area including taking out old u/s complete all as specified and directed by Engr-in-Charge
M&L for 120 Sqmm, 3.5 core cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor including laying/fixing on wall/ floor with clip and trunch complete with thimbles including taking out old unsv cable complete all as specified and directed by Engr-in-Charge.
All as per item No 138.00 above but for size 95 Sqmm 3.5 Core complete all as specified and directed.
All as per item No 138.00 above but for size 70 Sqmm 3.5 Core complete all as specified and directed.
All as per item No 138.00 above but for size 50 Sqmm 3.5 Core complete all as specified and directed.
All as per item No 138.00 above but for size 35 Sqmm 3.5 Core complete all as specified and directed.
All as per item No 138.00 above but for size 25 Sqmm 3.5 Core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for UG cable etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and directed by the Engineer-In-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by the Engineer-In-Charge.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by the Engineer-In-Charge.
M&L for sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts complete all as specified and as directed by the Engineer-In-Charge.
M&L for brick laying with subclass 'B' bricks well burnt, laid dry flat in trenches for protection of cable over cable, complete all as specified and as directed by the Engineer-In-Charge
M&L preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 9 mtr long (410 SP-31) and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide ipto 1.5 mtr from ground level including marking of pole No's with paint complete all as specified and directed.
S&F in replacement LED inverter based 60 watt building security(street light) fitting complete with accessories made of aluminum housing having minimum system efficiency 100 lm/watt operating at full load at AC supply & minimum 20 watt during battery back up , power fractor is equal to or greater 0.95, CCT 6500K, CRI -80, IP-20, inbuilt Li-ion battery for backup, back up to 4 Hrs for complete all as specified and directed. Note: (a) Srl Item No 8.00, 12.00 to 17.00, 22.00 to 29.00, 40.00 to 42.00, 44.00, 45.00, 58.00, 67.00, 68.00, 94.00, 95.00, 99.00, 100.00, 110.00 to 113.00, 115.00, 116.00, 137.00, 138.00 to 143.00 & 150.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody. (b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge.
RUCHIKA ENGG.WORKS (BID ID -3380028)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .