| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹39.8 L+₹43,016.88 (1.09%)Rejected-Finance AT DAKRA KHALARI RANCHI JHARKHAND PIN CODE 829210 | RANCHI | RANCHI | JHARKHAND | 829210 | L2 | Rejected-Finance L2 | |
| 3 | L3₹40.5 L+₹1.1 L (2.91%)Rejected-Finance 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L3 | Rejected-Finance L3 |
Tender Value
₹42.3 L
EMD Value
₹52,900
Closing Date
22 Jun 2024, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
Dismantling, erection and extension of 6.6KV/3.3KV, 440V/230V Overhead line in mine supplying power to HEMMs, mine dewatering pumps and lighting installations for one year as and when required basis under KDH Project, NK Area
2024_CCL_310071_1
GM (NK)/EnM/e-NIT/2024-25/ 73
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KDH OCP, NK Area
As per NIT
2 documents required · 2 mandatory
₹52,900
15 Jul 2024
8 Jun 2024
24 Jun 2024
8 Jun 2024
22 Jun 2024
8 Jun 2024
8 Jun 2024 - 14 Jun 2024
Amount
PART A: 3.3KV/6.6 KV OVER HEAD LINE WORK
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 11.00 Metre and upto 13.00 Metre.
Erection of all aluminum conductor of 7/1.96 mm to 7/3.10 mm diameter and above including binding etc as required.
Supplying and erection of stay set complete (galvanized) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanized insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required. 90KN
Supply and erection of 11 KV pin insulator complete with large steel head G.I pin, nuts, washers etc as required. 90KN
Erection of disc / pin insulator for 11 KV over head lines as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11 KV overhead line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm MS flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11 KV / 22 KV / 33 KV Over head lines as required.
Supplying of 50 mm x 8 mm M.S. flat iron pole top bracket / cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductor complete with 50 mm x 6 mm flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc (as per drawing) and painting with primer and finished paint as required.
Erection of pole top / straight two wire/ V shape two wire, angle iron / channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supply of 8 / 6 SWG G.I. wire for erection of cradle guards.
Erection of cradle Guard as required.
Dismantling of pole / street light standard /strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper / aluminium over head conductor, G.I. wire, cross arms, insulators etc as required
Part B: 440V/220V Overhead line work
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 8.00 Metre and upto 11.00 Metre.
Erection of all aluminum conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc as required.
Supplying and erection of stay set complete (galvanized) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of 100 mm x 65 mm pin insulator complete with G.I Spindle and nuts etc as required.
Supplying and erection of 75 mm x 90 mm shackle insulator with G.I. Bolt, nuts and straps etc. as required.
Erection of LV / MV shackle / pin insulator etc as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Erection of angle iron / channel iron cross arm on wood / RCC / PCC/ Steel Tubular/ rail pole etc. as required.
Supply of 8 / 6 SWG G.I. wire for erection of cradle guards.
Erection of cradle Guard as required.
Dismantling of pole / street light standard /strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper / aluminium over head conductor, G.I. wire, cross arms, insulators etc as required
Part C: Maintenance of 6.6kV, 3.3kV and 440V/230V Overhead line for one year on as and when required basis
Disconnection and reconnection of conductors of jumper of 6.6 kV, 3.3 kV and LT OH lines for rectification of faults in these lines as well as for provision of power to the HEMMs, pumps and lighting transformers installed at mines area of KDH OCP.
Cable handling (lowering and lifting) of power cables for fault rectification/shifting of cables for HEMMs, pumps and lighting transformers.
Relocation / dismantling and re-rection of light fittings installed at different locations of mines.
Repairing of cradle guards / earth wires and stay sets.
Re-erection / Tensioning of the conductors of LT lines for maintaining the proper sag as well as after fault clearing of LT OH Lines.
Re-erection / Tensioning of the conductors of HT lines for maintaining the proper sag as well as after fault clearing of HT OH Lines.
Branch cutting / bush cutting under HT and LT overhead lines.
Total impact of GST for the purpose of CTC
M/S A. K. ENTERPRISES
M/S KUMAR ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .