Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC 1 IIND PADMA TOWER RAJENDRA PLACE WEST DELHI CENTRAL DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | ₹2.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹3.0 Cr+₹69.0 L (30.0%)Rejected-Finance | ₹3.0 Cr+₹69.0 L (30.0%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹4.4 Cr+₹2.1 Cr (90.1%)Rejected-Finance | ₹4.4 Cr+₹2.1 Cr (90.1%) | L3 | Rejected-Finance Being L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
18 Apr 2022, 5:00 pmClosed
Chief Executive Officer
Sagar Smart City Limited, Sagar Smart City Office, 2nd Floor, ICCC Building, New Collectorate Premises, Sagar, Madhya Pradesh-470002
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF SMART LED FLOOD LIGHTS IN CITY STADIUM OF SAGAR INCLUDING OPERATION AND MAINTENANCE FOR 2 YEARS UNDER SMART CITY MISSION
2022_UAD_188432_1
2022/SSCL/109
Open Tender
Electrical Works
Item Rate
180 days
SAGAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹2 L
SAGAR
3 Feb 2023
5 Mar 2022
20 Apr 2022
5 Mar 2022
18 Apr 2022
5 Mar 2022
15 Mar 2022
HIGH MAST SYSTEM
Design, Supply, Transportation, Assembly, Erection, Testing and Commisioning with all type of fitting accessories for 30 meter High hot dip galvanized high Mast Suitable for sports lighting (upto top of of head frame) suitable for installing required number of Flood Lights suitable for Wind speed . • Masts shall be structurally designed in accordance with ILE Technical Report No 7 –2003 edition considering the gust wind speed at site (Sagar) as per IS 875. • The steel used in the construction of the masts shall comply with BSEN 10025, J355 or equivalent. • All welding shall be undertaken and performed as per WPS/PQR in strict accordance with BS 5135. • Foundation drawing, test certificate and guarantee certificate shall be provided by manufacturer. • The head frame cross arm brackets shall be of suitable steel construction. • The mast manufacturer shall be accredited with ISO 9001 and ISO 14001. • All MS parts including hardware shall be hot dip galvanized as per BSEN-ISO1461 or equivalent. • The connection between the head frame and mast top shaft is by a flanged joint and bolted together. No slip joints in this position shall be used.
Supply, Assembly, Testing and Commisioning of Man rider for 30 meter Sports High Mast of 300 Kg Capacity. (This man rider is a mobile equipment and is common for all 4 Masts)
Supply, Transportation, Assembly, Erection, Testing and Commisioning of Low intensity type aviation obstruction luminaire to be mounted on highmast .weather /corrosion resisteance lamp assembly and housing complete as required as per direction etc.
Design, Supply of required material and Casting of Shallow Foundation for 30 m sports Stadium High Mast suitable for Soil Bearing capacity of 10 MT/sq m
Supply, Installation , Testing and Commisioning of DMX Controlled LED Flood lights (each floodlight will be ≥ 1000 Watt) including Accessories and DMX Programming with polycarbonate lens having CRI > 90, SDCM<5 and CCT of 5700K (tolerances on CCT: +/- as per ANSI C78:377A) with TLCI shall be 90 or more & should be flicker free <1% and shall be compliant with IP66 and IK08 classification. • Luminaire shall be designed to emit minimum lumens required as per sport standards to play night matches (without broadcasting system) with minimum system wattage of 1000W at a system efficacy of at least 100 lumen/watt. • The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 35°C • The luminaire should have choice of Narrow beam, symmetrical medium and symmetrical wide beam suiting various applications with exposed single PC optic lens for the whole luminaire. The luminaire should have fans on the back to ensure good heat dissipation and to prevent dirt from settling on the luminaire along with aiming angle scale. The luminaire should be marine salt protected, vibrations proof and wind force protected. The luminaire enables interfacing with an external light console to control LED with other DMX fixtures. The electronic driver should be fully integrated and shall have a power factor >0.95 and THD <10% with a minimum inbuilt surge protection of 10kV inbuilt in the driver and suitable for an operating temperature range of -40 to 50 deg C. • The driver must have control interface compatible with DMX-RDM protocol and shall have suitable RJ45 ports in electrical compartment of the driver box for integration with Dynamic Lighting Control Systems and 3rd Party A[1]V Systems. The driver shall have separate cable gland suitable for DMX cable entry and outgoing. Weight of the luminaire should not exceed 18 kgs and with driver should not exceed 25 kgs. The luminaire should comply with all the required IEC and IS standards. LM79 and LM80 reports must be submitted from a NABL accredited laboratory. Luminaire and driver must have BIS certificate and the same must be submitted for record. • All plastic parts, cables used etc shall be preferably UV protected. • The driver shall have separate cable gland suitable for DMX cable entry and outgoing. Supply of DMX Control system for floodlights including accessories, Supervision of Floodlight installation, Aiming and DMX Programming •1 Set = Total Floodlight System installed in 4 High Mast
Supply, Installation , Testing and Commisioning of DMX controllers, splitters, DMX wires, GI conduits, programming etc. DMX Controls shall be used for – • The right quality of light-improving visibility and safety during sports • Flexibility of field illuminations as many configurations is possible • Reducing light pollution by better optics and dimming to the right level • Energy efficiency, saving on energy costs and promoting the green credentials of your sports club • Better returns on investment with better value beyond pitch lighting illumination Low maintenance costs due to the long lifetime of LED lighting
Supply, Installation , Testing and Commisioning of LED type twin Dome Aviation Obsruction Light
Supply, Installation , Testing and Commisioning of Main Panel I/C-160 A FP MCCB with 5 nos O/G MCCB 63 A FP for stadium mast
Supply, Installation , Testing and Commisioning of of High Mast Control panel with I/C-63A FP MCCB & 25 A TPN MCB with contactor - 2 for Man-rider stadium mast
Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 3 Core
Supply & Laying of DWC pipe 50mm OD
Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt ) complete as required.
Add Extra for using salt and charcoal / coke for G.I. Plate or Copper plate earth electrode as required including excavation & refilling.
Providing & fixing 25mm X 5mm copper strip in 40mm dia G.I.pipe from earth electrode as required.
Supply, Laying, Testing and Commisioniing of 25X6MM GI strip
Supplying of integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired up to terminal block. LED of 1 to 3W each assembled on single MCPCB, having color temp6500K & having 50000 burning hrs life with minimum @ L70, system lumen output should be minimum with efficacy>80lm/W. LED driver PF 0.95 & surge protection 2KV. The colour rendering index of LED light should be more than70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete thejob. 2 Yrs Guarantee certificate from manufacturer. 40W
Supply of XLPE Insulated power cable (conforming IS-7098) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor 3.5cx95sqmm al armoured cable.
Providing and erection of black painted galvanized decorative designer poles 3 meter in different section, top 60mm dia., bottom 140mm dia. with gold colour painted ornamental cast aluminium ring having lockable weather proof flush door junction box in bottom section, base plate dia. 290mm having 4 holes of 22mm dia. complete erected in an approved manner on existing foundation. Suitable size & type of foundation bolts 4 nos. X 16mm X 450mm 'J' type (EN8 grade) 3m Height
Supply of XLPE Insulated power cable (conforming IS-7098) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 4 core x25sqmm ISI MARKED with Alu. Stranded /solid conductor
LUGS:Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu. /Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size 25sqmm
LUGS:Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu. /Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size 25sqmm
Supplying & fixing pin terminal lugs as per ISS specification suitable for cable evently cramped with high pressure tool & connection to switch gear terminal.Copper Lugs Tube Type - upto 16 sqmm
Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete Gland size 32mm suitable for cable 2,3, 3½, 4 x 25 Sq.mm OR 2,3, 3½ x 35 Sq.mm OR 2,3 x 50 Sq.mm.
Supply,Laying, Testing and Commissioning of Unarmoured copper cables (as per IS 1554) from high mast control Panel to individual luminaires 3cx2.5sqm
Gland Size 45mm suitable for cable 3/3½ x 120 Sq.mm OR 3½ x 95 Sq.mm OR 3 x 150 Sq.mm.
DIESEL GENERATOR (DG SET)
Supply, installation, testing and commissioning of diesel generating set three phase, water cooled with AMF control panel, 150/160 KVA, 415V.With electronic governor.
LED STRIP FOR INDOOR & OUTDOOR STAIR
Supplying, fixing & testing of approved make flexible LED strip comprising of 60 LED per meter W/O driver for direct mounting complete with all accessories including connection lead, fixing, connection as required. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.Flexible LED strip 24Watt/25Watt - 5 M outdoor cove light W/O driver IP65
Supplying, fixing & testing of approved make flexible LED strip comprising of 60 LED per meter W/O driver for direct mounting complete with all accessories including connection lead, fixing, connection as required. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.Flexible LED strip 24Watt/25Watt - 5 M indoor cove light W/O Driver IP 20 -33
SUB-STATION
Supplying, installing, testing and commissioning of 11/0.4 K.V. 3 Phase 50 Cycle oil immersed, naturally cooled, out door type transformer connected delta on H.T. side and star on L.T. side hand operated off load, Tap changer switch,above 100 kVA rating and diagram plate, two earthing terminal, lifting lugs, oil level guage, drain valve with plug, temperature not exceeding 50ºC on load, oil conservator with drain plug, oil filling hole with plug dehydrating silica gel breather, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all Required materials arrangements as required as per IS specification.Aluminium wound 200 KVA
Supply of support for overhead line RS joist / H-beam of I.S. standard including welding, drilling of required hole etc. complete as required.H-Beam 152x152mm , Std weight 37.1 kg per meter
Erection of RS Joist pole/'H' beam/steel tubular/steel rail pole of lengt exceeding 10 metres but not exceeding 13 metres in cement concrete M-10 (1 cement:3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required.
Supplying installing and testing of AB isolating switch assembly set gang operated suitable for 11/0.4 KV, DP structure with brass part contacts, operating rod with required GI pipe, handle locking arrangement on On-Off position conforming to IS complete with required material and installing on existing structure to complete the job as required as per specification.11KV
Supplying, installing ,testing of 11 KV D.O. fuse assembly with brass part contact for 11/0.4 KV DP Structure set of 3 with fuse with barrel with required fuse element & other materials as per specification on existing D.P. structure as required.(set of 3nos.)11KV
Supplying, installing, testing and commissioning of LT Distribution Box with TPN isolator of 600 amper on incoming,bus bar and 6 S.P.M.C.C.B.of 120 A" .on outgoing side for 200 KVA transformer
Supplying, installing, testing and commissioning of Lightning Arrestors.) 11 KV Gapless, line type
Supplying, installing, testing of earth Coil (coil of 115 turns of 50mm dia, and 2.5 Mtrs. Lead of 4 mm G.I wire.
Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any) ACSR 0.075 sq inch (80 sq.mm Al. EQ.)- (Raccoon)
Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any) AAAC 0.05 sq inch (55 sq.mm Al. EQ.)- (Rabbit)
Supplying and erection of galvanised stay set for 11kV overhead line complete with 19/20mm dia x 1.8 meters long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle (20mmx 600mm), 7/4.00mm dia G.I. stay wire and 11kV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm. nominal size) foundation including excavation and refilling etc. as required.
Supplying and erection of 11kV pin insulator complete with large steel head G.I. pin, nut, washer etc. as required.
Supplying and erection of 11kV disc insulator for 11kV overhead lines with galvanised insulator fittings, ball and socket type, and complete with galvanised strain clamp,bolts,nuts washer etc. as required.
Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt ) complete as required.
Earthing with Copper Earth plate 600mm X 600mm X 3mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt) complete as required.
Add Extra for using salt and charcoal / coke for G.I. Plate or Copper plate earth electrode as required including excavation & refilling.
Providing and fixing 25mm X 4mm G.I. strip on surface or in recessed/concealed for connection etc. as required.
Providing and laying copper tape 32mm X 6mm thick for earth electrode directly in ground as required
Supplying and laying G.I. earth lead duly installed on wall or in G.I. Pipe including connections etc complete as required 13 sq mm ( 4 mm dia )
Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per MPMKVVCO. Specification
Supply of Hand Gloves 33KV Tested
Supply of Fiber Discharge Rod I/C Connection copper Lead Tested
Supply of shock instruction chart duly framed with glass, as reqd
Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric sub-station switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 mt. apart or as required. The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel shall be erected between the posts. The angle iron post shall be erected in cement concrete M?15 (1:2:4) (20 mm graded metal) foundation, including excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade.
PVC sleeve RYB
Supplying, installing, testing and commissioning of LT Distribution Box with TPN isolator of 600 amper on incoming,bus bar and 6 S.P.M.C.C.B.of 120 A" .on outgoing side for 200 KVA transformer
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 3½ core unarmoured150 Sqmm Cable.
Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 3½ core unarmoured 300 sq. mm.
Supply, installation, testing & commissioning of LT trivector energy meter, DLMS compliant category-A (for substation/feeder metering) , 3 phase 4 wire, 440 Volts, 5 Amp, accuracy class 0.5S with GSM(GPRS compatible) modem suitable for required C.T. 5A duly tested from electricity board with uPVC box .
Anti Climbing Device (Barbed Wire 3.5 Kg) GS 2.5 mm Dia (12SWG)
Primer coat over new steel and other metallic surface with red oxide/zinc chromide paint complete with supply of material labour etc. including preparation of surface.
Primer coat with aluminium paint, brushing complete with material and labour including preparation of surface.
Supplying & fixing of Fire Extinguisher/Refills as per IS specification ABC type duly refilled 6 Kg & ready to use
Supplying & fixing of Fire Extinguisher/Refills as per IS specification 4 buckets set with sand, self supported M.S.stand i/c shed duly painted with red colour as per IS
Supplying and fixing of LT Panel accessaries of approved make in existing LT Panel including connections etc.as required as per spececification. Frequency Meter
Supplying and fixing of LT Panel accessaries of approved make in existing LT Panel including connections etc.as required as per spececification. Aluminium bus bar strips with PVC sleeves
Supplying and fixing of LT Panel accessaries of approved make in existing LT Panel including connections etc.as required as per spececification. LED lamps
Supplying and erection of 30A aerial fuse complete asrequired.
MCCB with Breaking Capacity 35 KA at 415 V. Current Rating -400 Amps & Adjustable: 70% -100% thermal & 4- 10 times magnetic setting
MCCB with Breaking Capacity 35 KA at 415 V. Current Rating -200 Amps & Adjustable: 70% -100% thermal & 5- 10 times magnetic setting
MCCB with Breaking Capacity 35 KA at 415 V. Current Rating -160 Amps & Adjustable: 70% -100% thermal & 5- 10 times magnetic setting
MCCB with Breaking Capacity 25 KA at 415 V. Current Rating -25 to100 Amps & 70% -100% adjustable
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- FOR TRIPLE POLE (TP). 6 Amp to 32 Amp Rating
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898:2002 but without enclosures :- SINGLE POLE (SP). 6 Amp to 32 Amp Rating
Supplying and fixing MNx 32Amp
Supplying and fixing MNx 25Amp
Supplying, Fixing and Testing of mixed die-electric ultra heavy duty APP capacitor 440 Volt, 3 Ph., peak inrush current upto 500 x In, over current upto 3 x In(normal current), operating losses total not more than 0.35 W / KVAr, operating life not less than 300000 hrs, switching 20000 operation / year, as per IS:13340-1993, IS:133411992, IS:13585-1994, of approved make as required as per specification 5 to 25 KVAr bank
ON/OFF push button with WL ring
Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 3½ CORE. 240 Sq.mm.(XLPE)
Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 3½ CORE. 150 Sq.mm.(XLPE)
Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 4 CORE. 16 Sq.mm.(XLPE)
Cable Laying of one number PVC Insulated and PVC sheathed power cable of 1.1.kV grade of size exceeding 120 Sq mm but not exceeding 400 Sq.mm direct in ground including excavation and cushioning protective covering and refilling the pit etc. as required.
Cable Laying of one number additional PVC insulated and PVC sheathed power cable of 1.1kV grade of size exceeding 120 Sq mm but not exceeding 400 Sq mm direct in ground in the same trench in one tier horizotal formation including excavation, send cushioing, protective covering and refilling the pit etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed aluminium conductor cable of 1.1kV grade of size not exceeding 25 Sq.mm on surface etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed aluminium conductor cable of 1.1kV grade of size exceeding 120 Sq.mm but not exceeding 300 Sq.mm on surface etc. as required.
BRASS COMPRESSION GLAND Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland Size 70mm 3 x 240 Sq.mm 3½ x 300 Sq.mm
BRASS COMPRESSION GLAND Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland Size 50 mm 3½ x 150 Sq.mm 3 x 185 Sq.mm
BRASS COMPRESSION GLAND Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland size 28mm for 3,4 x 16 Sq.mm
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size-300 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 240 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 150 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 95 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 70 Sq.mm
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 6mm to 16 Sq.mm
Suppying & installing G.I. Pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/everhead service line/for submer cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, te, elbow, nuts and bolts etc. complete in an approved manner as required to complete the job excluding cost of excavation/dismateling & other finished masonary Item complete. A' Class G.I.Pipe ISI Marked (IS-1161-69) 100 mm
Supply of Rubber mat 2 x 1.0Mtr, 1100V Tested
Designing and construction of Pedestal (Plinth) for transformer of desired size including excavation in hard rock/soft rock, base concrete 1:4:8, 20mm thick and pedestal of RCC 1:2:4 including required tar steel reinforcement for required height as per IE Rules from base concrete including shuttering and finishing with 10mm thick plaster in cement mortor 1:3 curing & white washing etc. complete as per specifications.
ELECTRICAL CONTROL ROOM (Electrical Work)
Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- a) Short point
Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- b) Medium point
Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- c) Long point
Point wiring including metallic switch box, sheet, switches, sockets for 3 pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board .
Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size including painting etc. as required as per specification 1.3.6 (a) 2x2.5 Sq.mm.
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH FLUSH TYPE ACCESSORIES SOR 1.5.1 Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (HMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for :- (C)Long Point
MODULAR SWITCH BOXES SOR 2.9.3 Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- 6 Module
MODULAR SWITCH BOXES Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch,socket etc. as required for:- 12 Module
CIRCUIT WIRING IN EXISTING CONDUIT / PVC CASING CAPPING 1.5 Sq mm cable - 3 X 1.5 sq mm
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- 8.5.1SINGLE POLE (SP) 8.5.1.2 6 Amp to 32 Amp Rating
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- 8.5.3 DOUBLE POLE (DP) 8.5.3.3 For 40 Amps. Rating only.
Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with KA value rating 10 kA of approved make confirming to IS :13947-Part III : 1993 & IEC :60947- 3:2001 (without enclosures) :-
Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Busbar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032( exclusive of MCB & isolator)- 8 way double door
Suppling and fixing of approved make step type Modular electronic, Fan regulator single/double module including connection etc. as required on existing board
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS :374/1979 with upto date ammendments. Ceiling Fan (Energy Saver 60 W)-1400 mm Sweep
Supplying, erecting and testing of approved make Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished and as required. 450mm sweep 900 RPM
Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per specification LED Lamps
Supplying, fixing and testing of approved make fluorescent single & double tube fitting 36/40 watt, rust resistant, stove enamelled paint, CRCA sheet steel housing with opal acrylic diffuser and decorative end plates complete with copper ballast complete duly wired (without tube rod) as per specification & fixing . 1 x 40/36 watt
Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor ARMOURED 3 Core 10 Sq.mm.(XLPE)
ELECTRICAL CONTROL ROOM (Civil Work)
Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. All kinds of soil
1.0 Transportation By Mechanical means including loading, unloading and stacking where ever necessary.5km or Part thereof.v
Supplying and filling in plinth under floors including,watering, ramming consolidating and dressing complete. Moorum/Hard copra
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. Cement concrete grade M-10 (Nominal Mix) with 20 mm maximum size of stone aggregate
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate. For Beams
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc.For Columns.ement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. For columns
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete. Moorum/Hard copra
Brick work with well burnt chimney bricks in bulls patent trench kiln ,crushing strength not less than 25kg /sqcm and water absorption not more than 20% in foundation and plinth.Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with chimeny brick of class designation 40 in superstructure above plinth level upto floor 2 level including the cost of scaffolding in : Cement mortar 1:4(1 cement : 4 coarse sand)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for :Foundations, footings, bases of columns, etc. For mass concrete.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for Suspended floors, roofs, landings, balconies and access platform.
12 mm cement plaster of mix :1:4 (1 cement: 4 sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:4 (1 cement: 4 fine sand).For Outer Walls.
White washing with lime to give an even shade:New work (three or more coats
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Cement concrete flooring M-15 (nominal mix) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm maximum size of stone aggregate.
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts embedding hold fasts in cement concrete blocks with cement concrete grade M-10 (Nominal Mix with 20mm maximum size of stone aggregate) painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 meter lead :Door Chowkhats
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts embedding hold fasts in cement concrete blocks with cement concrete grade M-10 (Nominal Mix with 20mm maximum size of stone aggregate) painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 meter lead :Window Chowkhats
Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM Rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters using following hinges.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Instapower Ltd.
SURYA ROSHNI LTD
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .