Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC JAISALMER | JAISALMER | RAJASTHAN | 342310 | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.2 L+₹21,581.50 (0.62%)Rejected-Finance 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹36.0 L+₹98,899.29 (2.83%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹39.6 L+₹4.6 L (13.2%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹40.5 L+₹5.5 L (15.6%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
27 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
PROVN OF OFFICE ALONGWITH TOILET, STONE SET PAVING CROSSING AND CERTAIN OTHER MINOR WORKS UNDER GE (A) JAISALMER
2023_MES_583990_1
8270/22-23/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹87,000
Yes
31 Mar 2023
2 Mar 2023
29 Mar 2023
2 Mar 2023
27 Mar 2023
15 Mar 2023
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in hard rock complete all as specified & directed by Engineer-in-Charge. Note (i) Hard rock obtained from excavation shall be stacked properly. Stacked hard rock shall be measured by deducting 50% quantity for voids for hard rock, remaining quantity will be considered of soft/disintegrated rock. (ii) Hard rock obtained shall be issued under Schedule of credit, which shall not be allowed for uses in work.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge.
Removing excavated material soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
M&L for moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & directed by Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C-2, (using 40 mm graded stone aggregate) as in foundation concrete, mass concrete or supporting pedestal including necessary form work etc complete all as specified & directed by Engineer-in-charge.
M&L for Pre-cast cement concrete block masonry with solid block PCC (1:3:6) type C-1 exc 10cm in width and setting in cement mortar (1:6) complete all as specified & directed by Engineer-in-Charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-Charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified & directed by Engineer-in-Charge.
M & L for Keyed pointing to rubble masonry uncoursed or brought up to courses in cement mortar 1:4 complete all as specified & directed by Engineer-in-Charge.
M&L for rendering 15 mm thick, plaster in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for rendering 10 mm thick, plaster in cement mortar (1:6) on brick/ stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for rendering 10mm thick on brickwork or concrete on wall surfaces in cement mortar 1:4, finished even and smooth without using extra cement mixed with water proofing compound complete all as specified & directed by Engineer-in-charge. Note :- Supply only WPC will be measured and paid separetly.
M&L rendering 10 mm thick on fair faces of concrete surface in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
Supply only water proofing compound complete all as specified & directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and apply two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified & directed by Engineer-in-Charge
M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing path & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for 100 mm thick cement concrete (1:2:4) type B-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing path & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) laid in alternative bays as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25, 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by the Engineer in Charge.
M&L for Glazed ceramic coloured tiles 450x300x7mm thick in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 10mm thick backing coat in CM (1:4) complete all as specified and directed by the Engineer in Charge.
S&F solid PVC door frame of size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. Square tube suppling and fixing in opening as per specification and drawing complete all as specified & directed by Engineer-in-charge.
M & L for factory made solid PVC moulded door shutter, with particle board core 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-charge.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded all as specified & directed by Engineer-in-charge.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete without glazing bars, dovetailed or welded all as specified & directed by Engineer-in-charge.
S&F factory made steel ventilators with top hung shutters incl hinges, steel peg stay complete all as specified & directed by Engineer-in-charge.
S & F sheet glass 3mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F, glavanised mild steel wire cloth, 0.45 mm nominal dia of wire and average width of aparture 1.40mm and fixed with tinned tack or galvanised wire stapples complete all as specified & directed by Engineer-in-charge.
S&F, 3mm thick, figured glass, pin head type and glazing with oil putty in squares not exceeding 0.50 sqm in each panes complete all as specified & directed by Engineer-in-charge.
S&F 20mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F bib taps cast copper alloy with crutch or butterfly handle , fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore of pipe complete all as specified and directed by Engineer-in-charge. (Make :- Prayag cat part No. 9206, Cera F 2006151, Jaquar CON-047 KN or equivalent in Appx'C' list of makes)
S&F 15 mm bore stop cock, fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F angle valves, cast copper alloy, CP, fancy type cromium plated with long shank and cup, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15 mm bore dia of pipe complete all as specified and directed by Engineer-in-charge. (Make :- Prayag Cat Part No 9210, Jaquar CON 053 KN, Cera F 2006202 or equivalent in Appx'C' list of makes)
S&F 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F 32mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified & directed by Engineer-in-charge.
S&F Vitreous china wash down water closet pan (Pedestal pattern), white (EWC) with necessary P/S Trap and fixed in repairs including jet spray and seat cover complete all as specified & directed by Engineer-in-charge. (Make :- Cera Cat Part No-S1050104, hindware cat Part No-20011 or equivalent in Appx'C' list of makes)
S&F 1000 litres capacity, three layered, white colour Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed by Engineer-in-charge.
S & F 20mm bore dia ball brass valves high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F vitreous china wash hand basin, coloured, flat back, excluding pillar tap, waste pipe, and including cutting for and pinning in ends of brackets or erecting stand, complete all as specified & directed by Engineer-in-charge. (Make :- Prayag Cat Part No 9250, Jaquar CON 167KNS, Cera F 2006461 or equivalent in Appx'C' list of makes)
M & L for 10 ltr capacity valveless syphonic PVC flushing cistern with waste pipe fixed to wc etc complete all as specified and directed (Make :- Jaquar Cat Part No WHC-WHT-1842, Cera B 1010102 or equivalent in Appx'C' list of makes)
S&F 450 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified & directed by Engineer-in-charge.
S&F of Grating doom 100mm dia of PTMT (Minimum weight 25Gms) complete all as specified & directed by Engineer-in-charge.
S&F Single towel rail 600mm long complete all as specified & directed by Engineer-in-charge. (Make :- Jaquar Cat Part No ACN-111 NM, Prayag BA-20, Cera F 5003103 or equivalent in Appx'C' list of makes)
S & F looking mirror 700x500mm, 5mm thick complete all as specified & directed by Engineer-in-charge. (Make:- Prayag Cat part No BLM-02, case No B3510112 or equivalent in Appx'C' list of makes)
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified & directed by Engineer-in-charge. (Make : Prayag Cat part No BS 73, case F 702010S or equivalent in Appx'C' list of makes)
M&L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
M&L for providing water proofing treatment with APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric ( wt not less than 150gm/Sqm) applied on primed surface ( priming coat as per the directions of Manufacturer) by forced (torch) application with 10cm overlaps and finally coating the surface with bituminuous aluminum paint @ 100gm/Sqm complete all as specified and directed by the Engr-in-Charge.
S&F vitreous china urinal flat back,, white, with grating and union for discharge pipe (exclusive flushing cistern, flushing pipe, and waste pipe) including connections to flushing pipe and outpipes fixed all as specified and directed.(Make :- Jaquar Cat part No. URS-WHT-13261, Cera S 4020102, Hindware 60002 or equivalent in Appx'C' list of makes)
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
S&F, 150 mm size extruded aluminium alloy handles, fabricated type, anodised all as directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section all as specified & directed by Engineer-in-charge.
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-charge.
S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed by Engineer-in-charge.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165 complete all as specified & directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles (Joint free) of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed by Engineer-in-charge.
All as per item no 67.00 above but in skirting over 10 mm screed bed complete all as specified & directed by Engineer-in-charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified & directed by Engineer-in-charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in Soft/dense soil complete all as specified & directed by Engineer-in-charge.
Removing excavated material exc 250m but n.exc 500m and depositing where directed complete all as specified & directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern laid over and including 25mm thick sand cushioning compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
S&F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde E-250 quality-A) complete all as specified & directed by Engineer-in-charge.
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:2:4 type BO using 12.5 mm graded stone aggregate for levelling course for consolidated thickness shall be varied from 25 to 85 mm as per the requirements complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick plaster in cement mortar (1:4) mixed with WPC on concrete surfaces of roof top and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid seperately as supply only).
S&F Pressed steel frames for doors with one or more rebates of size 125x60 mm including necessary fixing lugs, hinges, lock strike plate, etc.,and including filling of pcc 1:2:4 type B-0 in pressed steel frame complete all as specified and directed by Engineer-in-charge.
S & F, 35 mm thick second class hard wood factory made plain, framed, panelled shutters, with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and Style as per IS:1003 (Part-1), kiln seasoned and chemically pressure treated all as specified & directed by Engineer-in-charge.
S & F, 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified & directed by Engineer-in-charge.
M&L for roughly squared stone 5cm thick as in lintels n exc 3m in length, hammer dressed on face and soffits, hoisted, set and pointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
Supply and fix Decorative Curtain Rails Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified & directed by Engineer-in-charge. (Note :- Pattern of Fixing bracket and stops as approved by Engr in charge )
M&L for 5cm sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete all as specified & directed by Engineer-in-charge.
M&L for precast cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in landings, shelves, cover slabs (manholes etc) and similar articls with plain faces, set in cement morat (1:6) with and including necessary form work complete all as specified & directed by Engineer-in-charge.
M&L for 150mm dia SGSW drain pipes grade `A’ (ISI marked) laid in trenches and jointed in CM 1:1 and tested complete all as specified & directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe all as specified & directed by Engineer-in-charge.
M&L for mild steel TMT bars 6mm to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-charge.
S&F 110 mm dia PVC (SWR) vent cowl complete all as specified & directed by Engineer-in-charge.
Cutting is to existing manholes for new drains, for removing existing branch drain, making good to walling and rendering cutting out branch channel and making good benching bore of pipe 150 mm complete all as specified & directed by Engineer-in-charge.
M&L for Construction of Septic tanks, excavation in any type of soil, foundation in PCC 1:2:4, stone masonary in CM 1:4, RCC slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc complete for 25 users complete all as as specified and as directed by Engineer-in-charge shown on drawings (Refer TD drg No. CEJZ/TD/31 dt. 14 Dec 2013 Sheet No. 1/3 to 3/3).
M&L for Construction of Soakage wells excavation in any type of soil, foundation in PCC 1:3:6, wells of honeycomed and solid in M-25 concrete, including intercepting chamber, screed chamber, stone masonary work in CM RCC cover slab in M-25/RR masonary/Filling with brick bats complete of size 1.8.m dia x 6.00 mtr deep complete all as as specified and as directed by Engineer-in-charge shown on drawings (Refer TD drg No. CEJZ/TD/29 dt. 14 Dec 2013 Sheet No. 1/3).
M&L for stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed, bedded in cement mortar 1:3, joints 20mm thick, grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete as directed by Engineer-in-Charge. Note :- Stone for the setts shall be of the best quality, granite, trap, basalt or quartzite. Use of sedimentary stone shall not be permitted. Stone setts shall be approximately rectangular in shape, with a tolerance of plus or minus.
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete as directed by Engineer-in-Charge.
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.
a) One light point controlled by one switch
b) One ceiling fan/Exhaust fan point controlled by one switch
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One 2/3 pin socket outlet 5Amps on independent board.
All as per item No 96.00 above but point wiring with 4 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 volts grade and 4.0 Sqmm PVC insulated and unsheated (FRLS) cable 1100 volts grade with multi stranded copper conductor as earth wire for 15/16 Amps multi porpose socket combination point on independent board. Note : Modular switch and socket shall be measured and paid separately.
S&F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-Charge.
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-Charge.
S&F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-Charge.
S&F step type modular fan regulator 120W -2 module ISI Marked with valid CML No complete all as specified & directed by Engineer-in-Charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-Charge.
Supply and fixing of building security light fitting LED 30 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment with fixing arrangement such as GI pipe bracket, MS clamp ,Nut bolts etc and connecting complete all as specified & directed by Engineer-in-Charge. Make Havells cat pot No .EDDURAPEARLSL30WLED757SASYTOPCMP or equivalent in Appx'C' list of makes)
S&F bracket of GI pipe light grade of 40mm bore dia, 1.2 meter in length, MS clamps made of FI 40 mm x 6mm incl nuts, bolts & washers including two coats of synthetic enamel paint over a coat of zink chrome primer complete all as specified & directed by Engineer-in-charge.
S & F surface and wall mounted LED tube light along with fixture, 4 ft, 20W, extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 V, 50HZ, AC supply and operating tempureture 0 to 50 C ,power factor >0.9, lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified & directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer including MCCB 100A 25 KA complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-Charge.
S&F fans ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-Charge.
Supply & fix exhaust fans AC single phase 230/240 V of size 300 mm sweep with louver in provision of existing wall complete all as specified & directed by Engineer-in-Charge.
M & L for point wiring for explosive atmosphere with 1100 volts grade PVC insulated unsheathed single core (FRLS) cable with stranded copper conductor of size 1.5 Sqmm drawn through and including ERW rigid stove enameled steel conduit of suitable size but not less than 19mm dia with and including bends, elbow, couplings & GI Saddle clips etc (duly approved/tested by CMRI) , fixed with and including 1.5 sqmm PVC insulated unsheathed single core (FRLS) cable with stranded copper conductor for continuous earth for following :- (Note :- Flame proof junction box shall be measured and paid separately under relevant item of the schedule).
One flame proof light point/ Fan point controlled by one switch complete all as specified & directed by Engineer-in-Charge.
S&F switch flame proof rotary type switch with termination box in LM6, 16A, single pole 250V complete all as specified & directed by Engineer-in-Charge.
S&F flame proof junction box 4 way for cable entry complete all as specified & directed by Engineer-in-Charge.
S&F flame proof double compression brass cable gland complete all as specified & directed by Engineer-in-Charge.
Supply and fixing LED light fitting 1x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable in flexible metalic conduit with suitable size complete all as specified & directed by Engineer-in-Charge.
M&L flame proof MCB DB SPN 4 way double door complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-Charge.
Supply and fix FLP/WP switch/Isolator 10 Amp double pole ON/OFF complete all as specified & directed by Engineer-in-Charge.
Supply and fix FLP/WP switch/Isolator 10 Amp single pole ON/OFF complete all as specified & directed by Engineer-in-Charge.
M&L Air termination, single pointed copper rod 12 mm dia 300 mm long with base fixing complete all as specified & directed by Engineer-in-Charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom, burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 32x6 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point earth dolly and earth chamber as shown in in elect plate No 2 of SSR Pt--I including all necessary earth work ,excavation ,earth chamber with PCC 1:3:6,Type C1 and RCC chamber cover of PCC 1:2:4 with handle and funnel for 20 mm dia GI watering pipe etc complete all as specified and directed Engg-in-Charge .
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to GI strip 25x4 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed Engg-in-Charge.
NOTE FOR ITEM No. 164.00 & 165.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with Aluminium strip of 25X3 mm size complete all as specified and directed Engg-in-Charge.
M & L Earthing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex. head screw.Material and labour for testing/termination point made out of 25 x 4 mm GI strip of length 150 mm duly housed in suitable MS box insulators etc for linking the down conductor and the earth terminals of the lightening arrester system complete all as specified and as directed Engg-in-Charge.
Supply and fix insulators made out of porcelain for fixing the lightening roof conductor and the down conductor complete all as specified & directed by Engineer-in-charge.
Supply, laying and testing LT XLPE insulated, armoured heavy duty, electric cable, with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core complete all as specified & directed by Engineer-in-charge.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCCB 4 Pole 160 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
M& road cutting in trenches for laying cable protection pipe including making good the surface with top 200mm thick shall filled with PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-charge. Note :- (i) Rate quoted by the Contractor shall deemed to inclusive of road cutting, earth work, excavation & PCC. (ii) Supply and laying of pipe will be measured and paid seperately.
S&F 20mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings laid in trenches or fixed to walls/ ceiling or under floors etc complete all as specified and directed by Engineer-in-charge.
S&F 40mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings laid in trenches or fixed to walls/ ceiling or under floors etc complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore gun metel, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed with fittings and accessories. ISI marked and as per IS 14846 complete all as specified & directed by Engineer-in-Charge
S&F 40 mm bore gun metel, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed with fittings and accessories. ISI marked and as per IS 14846 complete all as specified & directed by Engineer-in-Charge
Supplying, installing, commissioning and testing of hi wall split type air conditioner units of capacity 2 TR, indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality 5 star rating non CFC type with nominal cooling capacity system complete all as specified & directed by Engineer-in-charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed by Engineer-in-charge.
MARUDHARA CONSTRUCTION COMPANY
M/S OM VISHNU ENGINEERING & CONSTRUCTION COMPANY
Bhawani Constructions
Leelashah Enterprises
AMBEY MAA CONSTRUCTION COMPANY
M/S MAYA CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .