E.E. JSV Division Anni
E.E. JSV Division Anni
SH C/o Main Channel over RCC Columns at RD 360 to 450 90 Mtrs., C/o PCC Retaining wall 90 mtrs. and wire crate as embankment protection at RD 360 to 450 mtrs.
2026_HPIPH_126610_1
11578-623
Open Tender
Civil Works
Item Rate
180 days
Nither
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,000
₹1.0 L
5 Feb 2026
24 Jan 2026
3 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
Cutting in earth work and disposal of excavated earth in all kind of soil such as pick work, jumper work, blasting work in soft/ hard rock or chiseling wedging, out soft/ hard rock where blasting is prohibited i/c all leads and lifts complete as per direction of Engineer-in-charge.
Excavation in foundation trenches etc. in all kinds of earth work such as spade work, pick work, jumper work saturated /un saturated soil blasting work and chiseling/wedging out of rocks where blasting work prohibited up to all depth and lifts including pumping and bailing out water where ever required stacking the excavated earth not more than 3mtrs.clear from the edge of excavation and then returning the stacked soil in 15cm.layers when required into the plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated material within all leads and lifts, useful material available from excavation to be properly stacked and handed over free of cost to the department as per direction of the Engineer-in Charge.
Providing and laying cement concrete 1:3:6 (1cement: 3sand: 6 graded stone agg.40mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per satisfaction and direction of Engineer-in-charge.
Providing and laying cement concrete 1:1.5:3 (1cement:1.5 sand : 3graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and re-inforcement for reinforced concrete work in:
Foundations, footings, basis of columns & the like and mass concrete.
Wall (any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level.
Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and cantilevers up to floor two levels within all leads and lifts as per direction of Engineer-in-Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs.and removal of the same for in situ reinforced concrete and plain concrete work including all leads and lifts:
Foundation footing and bases of columns & like mass concrete.
Column pillar, Piers, Abutments, post and Struts.
Lintels, beams, plinth beams, girders, bressummers and cantilevers.
Vertical surfaces such as walls (any thickness)portions and the like including attached pilaster buttresses plinth and string course and the like
Flat surfaces such as soffits of suspended floors, roofs, landings and the like, floors etc upto 200 mm in thickness with in all leads and lifts as per direction of Engineer-in-Charge.
Providing Placing &Laying mild /tor steel reinforcement for RCC. work including bending, binding and placing in position complete up to floor two level including all leads and lifts.: a) Tor steel
Providing and laying cement concrete 1:5:10 (1cement: 5sand: 10 graded stone agg.40mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per satisfaction and direction of Engineer-in-charge.
Wire crates made of G.I.wire filled with boulders with square cut faces against the wire, (Boulder filling to be measured and paid for separately) i/c all leads and lifts. (a) G.I.Wire 5mm thick corresponding to SWG-6 (15Cmx15cm.Mesh). within all leads and lifts.(TR)
Wire crate made of G.I wire filled with boulders with square cut faces against the wire (Wire crate to be measured and paid for separately)in all leads and lifts as per the direction of Engineer-in-Charge.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.64 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.30 MB
form8.pdf
Tender Documents • 1.28 MB
terms.pdf
Tender Documents • 0.48 MB
BOQ_186776.xls
BOQ • 0.34 MB
form6.pdf
Tender Documents • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .