Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹17.9 L+₹2.8 L (18.4%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹17.4 L+₹2.3 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Sept 2019, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Biakner
Repair maintenance of internal wiring, A/C equipment, Fans and Geyser of 187 MH at Mil Stn Bikaner
2019_MES_277684_1
GE (N) BKN/Token-40/19-20
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (N) Bikaner Mil Station
Class E Category b (i)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹40,000
Yes
17 Mar 2020
27 Aug 2019
24 Sept 2019
27 Aug 2019
23 Sept 2019
11 Sept 2019
Amount
Taking down carefully existing unserviceable Copper/ aluminium batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engr-in-Charge.
Taking down of unserviceable DBs/switch fuses/changeover in sheet steel enclosure complete with MCBs/Fuse/grips any capacity and removing from site and making good disturbed surface of wall, floor etc. Taking after disconnecting all cable complete all as specified and as directed by the Engr-in-Charge.
M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in existing PVC concealed conduit and including new sunken box covered with and including 3 mm thick bakelite laminated sheet top cover of approved make for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 03 here-in-before but One 3 pin socket outlet 5 Amps on the same board with other switches.
All as per item No 03 here-in-before but One 3 pin 5 Amps socket point on independent board.
Point wiring with stranded copper conductor cable 1100 volts grade (ISI marked) PVC insulated and unsheathed single core of size 2.5 Sq mm single core in and including PVC casing capping with all fittings such as tees, bends etc terminating in MS sunken box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ for one socket outlet and/or switch-socket-outlet, 15 Amps independent including provision of 2.5 Sqmm PVC insulated unsheathed copper conductor cable single core as earth wire to the common earth & connecting to earth dolly complete all as specified and as directed by Engineer-in-Charge. Note :- Two run of 2.5 Sqmm cable & one run of earth wire shall be measured as a single unit( For Geyser also)
All as per item No 06 here in before but in existing conduit
S&F switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge Make :- Anchor/Leader/Havells
S&F socket outlet flush type, 3 pin, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make : - Anchor/Leader/Havells
S&F Bell push button piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge Make : Anchor/Leader/Havells
S&F Bell Ding Dong AC single pole 230 volts multi music type complete ISI marked, all as specified and as directed by Engineer-in-Charge. Make : Make : Anchor/Leader/Havells
S&F switch piano flush type, Single pole 15 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge Make : Anchor/Leader/Havells
S&F socket outlet flush type, 3/5 pin, 5/15 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make : - Anchor/Leader/Havells
S&F lamp holder insulated body with back plate complete all as specified and as directed by Engineer-in-Charge. Make :- Anchor/Leader/Havells
S&F in replacement ceiling fan regulator electronic type, 230 Volt, 150 Watt with 5 step of control including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge. Make:- Anchor /Leader/Havells
S&F in replacement ceiling rose PVC/poly carbonate insulated body three terminal ISI marked, complete all as specified and as directed by Engineer-in-Charge. Make :Anchor/Leader/Havells
S&F Sheet metal enclosure for distribution boards, double door type suitable for fixing MCBs 240 volts 8 way with 200 Amps rated bus bar, SPN, , supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make - Legrand/ GE/Seimens
S&F Sheet metal enclosure for distribution boards, double door type suitable for fixing MCBs 240 volts 12 way with 200 Amps rated bus bar, SPN, , supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make - Legrand/ GE/Seimens
Supply and fixing sheet metal enclosures double door for distribution box made out of CRCA mild steel sheet surface powder coated surface mounting TPN 4 way 415 volts 200 Amp rated bus bar & vermin proof suitable for incorporation of MCBs & isolators etc completed all as specified and directed by Engineer-in-charge Make - Legrand/ GE/Seimens
S&F Sheet metal enclosure for distribution boards, enclosure double door (VPTN) 4 way TPN 415 Volts with 200 Amps rated bus bar with one MCCB TP 100 Amp 415 Volts 25 KA as incommer , including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make - Legrand/ GE/ Seimens
S&F MCB single pole, 240 volts of rating 6-32 Amps, breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make :- Legrand/ GE/ Seimens
S&F MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens
S&F in replacement PLL LED Lamp two pin 9W complete all as specified Make :Crompton Greaves/Philips/Wipro
S&F in replacement PLL LED Lamp two pin 11W complete all as specified Make :Crompton Greaves/Philips/Wipro
S&F in replacement PLL LED Lamp two pin 13W complete all as specified Make :Crompton Greaves/Philips/Wipro
S&F in replacement PLL LED Lamp four pin 18W Make :Crompton Greaves /Philips /Wipro
S&F in replacement PLL LED Lamp two pin 18W Make :Crompton Greaves /Philips /Wipro
S&F in replacement Moulded Case Circuit Breakers (MCCB) 04 pole of capacity 100 Amp 50 Hz 415 Volt with rupturing capacity 16 KA with including fixing arrangement on the MS/angle iron sheet including nut, bolt etc. complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens
Supply & fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volt complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand/ GE/ Seimens
S&F Decorative ultra slim linear LED lightening fixture, energy efficient 18/20 Watt complete all as specified and directed by engineer-in-charge. Make SYSKA/BAJAJ/PHILIPS
S&F Decorative ultra slim linear LED lightening fixture, energy efficient 9/10 Watt complete all as specified and directed by engineer-in-charge. Make SYSKA/BAJAJ/PHILIPS
Supply & fix LED bulk head ,09W / 10 W, IP65 dia cast aluminium housing powder coating finished complete all as specified and directed by Engineer-in-charge. Make Syska / havell's / Phillips.
Supply and draw in replacement sub main wiring of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through existing conduit and including one run of 6.0sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.)
ditto as item No 35, above but 4.0 sqmm and earth wire as 4 sqmm
Repair to sheet metal LT panel floor mounted 415 volts, 50 Hz any type and capacity and removing the unserviceable parts and , checking all joint & wiring and testing after replacement of unserviceable parts including one coat of synthetic enamelled paint over complete LT panel. Note : New items paid for separately in relevant items.
Supply and fixing LED type phase indicator (RYB) with base holder
Supplying and laying in replacement through pipes / drains/ ducts/ floors/ walls / ceilings/ equipment etc under ground cables XLPE LT PVC insulated armoured of cross sectional area 25 Sqmm x 3 ½ core heavy duty cable with aluminium conductor 1100 volt grade ISI marked of following cross sectional area all as specified and directed by the GE and Engineer in Charge. Make : Havell's/NICCO/ICL/CEI/RPG
All as per item No 39 here in before size of cable 35 Sqmm 3.5 core Make : Havell's/NICCO/ICL/CEI/RBG
All as per item No 39 here-in-before but section of cable 16 Sqmm x 2 Core Make : Havell's/NICCO/ICL/CEI/RBG
M & L in replacement of old unserviceable flood light fittings in to LED Flood light luminaries with secondary optics made in pressure die cast housing and heat single in aluminium extrusion with IP66 of capacity 120 watt Cat Part No BARFEG120WLED in make Bajaj/ Havells /CG
M & L in replacement of recess mounted T5 minor optics luminaries of capacity 1 X 28 watt with LED lamp make : CG/Bajaj/Havell’s
Supply, Fixing and connecting of LED streetlight made up of pressure die cast aluminium housing with toughned glass and individual LEDs with secondary optics 45 watts Including suitable size street light fitting bracket with suitable size clamps, nut bolts and washers including twin core flexible cable 2.5 Sqmm as per site requirement complete all as specified as directed by Engineer-in-Charge Make – HPL,Phillips, Crompton greaves, Bajaj , Wipro, C&S
Taking down fan, Ceiling fan (1200/1400mm) and dismantling blades, opening the fan body carefully, and cleaning body and all moving part with suitable agent and greasing with best quality of grease and replacement of unserviceable part refixing and hanging the same complete after replacement of required parts and testing complete all as directed by Engineer-in-Charge.
S&F in replacement Ball bearings for ceiling fan of suitable for 1200/1400mm size fan all as specified and directed by Eng-in-charge. Make : NBC, SKF
S&F in replacement Capacitor 2.5 mfd , 230 Volts for ceiling fan all as specified and directed by Eng-in-charge. Make : Havells/Tibcon/Bajaj.
Taking out old burnt winding and Rewinding of ceiling fan 1200/1400mm sweep of any make,with suitable size of super enamelled copper wire, varnishing, drying, testing and shifting complete all as specified and directed by Eng-in-charge. Make : Chetak, Atlas, Millan
Taking down exhaust fan 230/300/450mm sweep, and dismantling blades, opening the fan body carefully, washing the bearings, body and all moving part with suitable agent and greasing with best quality of grease and replacement of defective part and make it functional, refixing and hanging the same complete after replacement of required parts and testing complete all as directed by Engineer-in-Charge (Spares shall be measured and paid separately).
Supply & Fixed replacement Ball bearing for Exhaust fan of 300/450 mm sweep of suitable size as specified and directed by Engr-in-Charge. Make :- NBC/SKF
Supply & Fixed replacement Capacitor 3.15 /4 mfd for exhaust as specified and directed by Engr-in-charge. Make : Havells, Bajaj, Usha
Taking down old burnt winding and Rewinding of Exhaust fan 230/300/450 mm sweep, with suitable size of super enamelled copper wire, varnishing, drying, testing and shifting complete all as specified and directed by Engr-in-Charge. Make of copper wire :- Chetak/Atlas/Millan
Taking down unserviceable compressor including bushes, grommets, sleeves, washers , mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing water coolers and Supply and fixing in replacement new compressor hermetically sealed unit (compressor) including provison of new bushes , grommets, sleeves, washers, mounting rubbers , nuts, bolts, terminal covers, brazing and clips of existing make and capacity in the existing water coolers of any make and capacity 120 litres.
S&F in replacement Filter for water coolers complete all as specified and as directed by Engineer in Charge
S&F in replacement Capillary tube of existing size of copper for water coolers complete all as specified and as directed by Engineer in Charge
S&F in replacement Drain pipe of same quality, length and dia meter as per existing for water coolers complete all as specified and as directed by Engineer in Charge
S&F in replacement Push cock 15 mm chromium plated (stainless steel) for water coolers complete all as specified and as directed by Engineer in Charge
S&F in replacement Thermostat for water cooler , 60/120/150 Ltr Make Indfoss for water coolers complete all as specified and as directed by Engineer in Charge
S&F in replacement Relay suitable for water cooler(compressor model KCJ-444 HAJ/ 2612 Make : Annapurna/ Hi-tec) for water coolers complete all as specified and as directed by Engineer in Charge
Supply and fixing overload protector for water cooler , 60/120, Ltrs compressor model KCJ-4440 Make – Annapurna/ Hi-tec
Supply and fixing capacitor 80-100 MFD (Running ) Make TIBCON
S&F capacitor 100-120 MFD (Running ) Make TIBCON
Taking down defective fan motor from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size. Fan motor of capacity 1/35 HP, 230 volts, single phase. Make: Devidyal/Cheyak/Milan including replacement of shaft, bushes, mounting rubbers, nuts, bolts and re-fixing after reassembling and testing in existing water coolers (Note: The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps.)
All as per srl item No 63 here in before Fan motor of capacity 1/10 HP, 230 volts, single phase.
S&F in replacement Blade for fan motor water cooler having compressor capacity 1/10 HP.
S&F in replacement Blade for fan motor water cooler having compressor capacity 1/35 HP.
REPAIR TO AIR CONDITIONERS Taking down of any size unserviceable compressor 1.5 ton capacity window/split type AC of any make and supply & fixing new compressor 1.5 TR capacity of AC including provn of new bushes , grommets, sleeves, washers, mounting rubbers , nuts, bolts, terminal covers, brazing and clips of existing make and capacity in the existing ACs and recommended by existing O.E.M.
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing window type/ Split type Air Conditioners, Refrigerator , Deep Freezer and Water cooler of any size of make and model as per existing complete all as specified and as directed by Engineer-in-charge.
PVC filters for AC (Window type )
Removing of existing window type / split type AC 1.5/2.0 Ton capacity mounting , cleaning of evaporator and condenser with alkaline based solution, washing of AC, oiling of fan motor and Refixing on mounting , including Provn for making opening air tight and dust proof including testing and commissioning complete all as directed.
Taking down defective fan motor from AC, dismantling the old burnt window from the motor and rewinding with super enamelled copper wire as per existing size Make : Milan/ Chetak/Devidyal including replacement of shaft, bushes mounting rubbers nuts bolts and refixing after reassembling and testing in existing AC.
Supply and fixing capacitor 45/50 MFD AC Motor
Supply and fixing relay for AC 1.5 Ton AC window type
Replacement of defective PCB of AC ( 1.5 TR).
REPAIR TO walk in cooler : Taking down of any size unserviceable compressor 01 ton capacity walk in cooler of any make and supply & fixing new compressor 01TR capacity of walk in cooler including gas charging , fan blade , fan motor any size, evaporator unit , condenser unit with connecting accessories etc. and recommended by existing O.E.M.
Repair to automatic voltage stabilizer 4/5 KVA capacity single phase of any make and & repair/replacement of unserviceable parts such as transformer , relay ,Volt meter etc as required at site and re-fixing the same after testing on its original position and as directed by Engr in Charge (Spares shall be measured and paid separately).
M&L rewinding of transformer with super enamelled copper winding wire for single phase volrt stabilizer of capacity 4/5 kVA.
Replacement of unserviceable relay for 4/5 kVA single phase volt stabilizer.
Replacement of unserviceable voltmeter 0-300 Volts single phase, square/round type as per sample.
Taking down unserviceable compressor including bushes, grommets sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing refrigerators and Supply and fixing new hermetically sealed unit (compressor) including provn of new bushes, grommets, sleeves , washers , mounting rubbers nuts and bolts , terminal covers, brazing and clips of existing make and capacity in the existing refrigerator for 190 Litres capacity of any make.
S&F in replacement Condenser for 190 Litres refrigerators of any make complete all as specified and as directed by Engineer in Charge
S&F in replacement Filter suitable for 190 Litres refrigerators of any make complete all as specified and as directed by Engineer in Charge
S&F in replacement Capillary tubes of copper existing sizes as per sample.
S&F Door gasket as per sample
Supply and fixing thermostat for refrigerator 190 Litres refrigerators of any make complete all as specified and as directed by Engineer in Charge
Supply and fixing relay for refrigerator 190 Litres refrigerators of any make complete all as specified and as directed by Engineer in Charge
S& F Plug top 5 Amp capacity, 230 volts
REPAIR TO DESERT COOLERS Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and apply one coats of black bituminous paint and applying spray painting with synthetic enamel paint to external surfaces of desert coolers and replacement of front steel grills, side panel, grass pad, regulator three step and on/off switch etc complete all as specified and as directed by Engr-in-charge.
Taking down carefully old unserviceable water pumps heavy duty of capacity 1/70 HP , 230 volts 50 HZ single in lieu providing new submersible type water pump complete all as specified and as directed by Engr-in-charge.
Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor kit 1/6 to 1/8 HP 230 volts 50 HZ including replacement of mounting legs complete all as specified and directed. Make : Khaitan/ Indo/ Cool Home/victor/CG.
S&F in replacement 1000 halogen Planoconvex spot light complete with 100 W halogen Bipin T-11 lamp spherical anodised reflector imported socket 150mm dia planoconvex lens, bottom sliding knob , yoke, colour frame & suitable clamp type SL-35H or Equivalent as approved. Make of fitting : Modern stage service, PR Lighting inc, Delhi Light & Music Center Jia lighting & Audio Equipment Co, Illumination india, Make of Lamp CG/ Phillips /Bajaj
S&F in replacement 1000W halogen profile light consisting of 2 nos, 150mm dia PC lenses, imported socket ellipsoidal anodised aluminium reflectro, 1000W halogen Bipin T-11 lamp, yoke colour frame & Suitable clamp, type : Modern - 220 or equivalent as approved Make of fitting . Modern stage service PR lighting Inc, Delhi Light & Music center, Jia lighting & Audio Equipments Co Illuminatio India Make of lamp : CG , Phillips,Bajaj
S&F 500W halogen flood light for cyclorama . Make of fittings : DTS , Italy , Modern Stage Service PR lighting Inc, Delhi Light & Music center Jia Lighting & Audio Enuipments Co, Illumination India, Make of Lamp. CG,Phillips,Bajaj
S&F 1000W halogen light with mash & bamdoor consisting of 2 nos singhle contect compressible holders yoke, 1000W halogen tube & suitable clamp type : HL-44 or Equivalent as approved Make of Fitting. Modern stage servcie PR lighting Ino , Delhi light & Music Center Jia , Lighting & Audio Equipments Co, Illumination India make of Lamp : CG, Phillips , Bajaj
Supply and fix in replacement of existing U/s circular light of any wattage, any make, from any hight and fixed LED commercial down light -round Recess mounting bakelit LED down light, round PDC aluminium body with outer frame, separate driver with 6000K of capacity 15 watt as per polycab cat part no PCGLRD 01 15 16 or equivalent make in CG, Bajaj, Havells
Supply and fix in replacement of existing FPL light fitting 3 x 36 watt of any make and fix with LED slim panel Edgelit LED slim panel having white powder coated extruded aluminium body with high quality LGP and PMMA diffuser separate HPF driver. suitable for arm strong and grid ceiling of size 2 x2 CCT 6000 K of capacity 40 watt as per polycab cat part no PCGLP ECO 2x2 40 60 or equivalent make in CG, Bajaj, Havells
S&F in replacement of existing foot light with LED foot light of capacity 1 x5 watt 230 volt indoor recess mounting foot light with all accessories
S&F in replacement of existing U/s cove light with 9 watt LED light fitting mounting in cove at the ceiling complete with all accessories.
S&F in replacement of existing high bay light /flood light fitting of any capacity and make with the LED Beam/flood lights of capacity 100 watt as per cat part no SSK-BLS-COB -100w of syska LED or equivalent make in CG, Bajaj, Havells
GS BUILDERS AND ENGINEERS
BIDAWAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .