| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹11.7 L+₹2.1 L (21.8%)Rejected-Finance A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹12.6 L+₹3.1 L (31.9%)Rejected-Finance | L3 | Rejected-Finance Being not lowest tenderer | |
| 4 | L3₹19.2 L+₹9.7 L (100.8%)Rejected-Finance | L3 | Rejected-Finance Being not lowest tenderer | |
| 5 | L4₹14.3 L+₹4.7 L (49.2%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L4 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
4 Jul 2023, 6:00 pmClosed
CWE AF TUGHLAKABAD
AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
REPAIR/MAINT OF STP AND SEWAGE INSTALLATION AT BRD AF STN UNDER GE (AF) TUGHLAKABAD
2023_MES_601392_1
CWE/TKD/TOKEN-12 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) TUGHLAKABAD
As per NIT conditons
7 documents required · 7 mandatory
₹500
HQ CWE AF TUGHLAKABAD
₹46,000
Yes
21 Aug 2023
6 Jun 2023
6 Jul 2023
6 Jun 2023
4 Jul 2023
20 Jun 2023
Amount
Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in the tank and removing/cleaning of tanks by scrapping with wire brush or any other means on walls and bottom of tank and removing the sludge / silt / sand / fungus etc deposited inside the sumps / tanks and depositing where directed, including writing the date of cleaning and due date of cleaning in white colour on black background on external walls complete all as required at site and directed by the Engineer-in-Charge at 7 BRD for Sewage Plant capacity 250/300KLD. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- No manual scavenging is allowed at any cost. The Engnieer-in-Charge shall ensured that no manual scavenging is being carried out at site any lapse shall be treated as per law of land and contractor alongwith Engineer-in-Charge shall be held responsible for the same
(a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved by the MCD (c) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. (d) Contractor shall insure all safety measures and will be responsible for all safety precaution of worker.
All as per item No 01 but cleaning of MBBR-1 and MBBR-2 of Sewage treatment plant capacity 250/300KLD complete all as specified and directed.
All as per item No 01 but cleaning of Tube settler/lamella clarifier of Sewage treatment plant capacity 250/300KLD complete all as specified and directed.
All as per item No 01 but cleaning of Treated water tank with chemical contact tank of size upto capacity 250/300KLD complete all as specified and directed.
M&L for cleaning and desiIting the sewage well of capacity ,dewatering the complete well,of 100 to 125 Cum removing all the deposited sludge, soil and other material from the well including bailing / pumping out muddy water from the well by manually or by providing suitable pump sets from bottom level of well, scrapping out the scales / deposits from inner surface of the well throughly, washing with bleaching powder and soda ash, cleaning / bailing out settled materials completely by any means and removing sludge to a distance up to 3 km out side of defence land limit and dispose off in low lying area including dewatering as required. Note:-(i) Contractor is to arrange own diesel pump, T&P etc for cleaning purpose and minor spares and consumable like small screws, washers, cleaning agents consumables etc is deemed to be included in the cost, the unit rate quoted deemed to be include all safety precautions to be taken while working in Lift well. (ii) The accumulated/deposited sludge after drying shall be disposed off out side the defence land to a distance exceeding 1.5 KM and not exceeding 5.00 KM from the Lift well cost of which shall be deemed to inclusive in the quoted rate and nothing extra shall be paid on this account. (iii) Before commencement of work, necessary arrangement for disposal of sewage/sludge be made and work to be carried out in fast pace by deploying more man power at lift well in order to complete the work at the earliest.
Supply only Calcium based granule Chlorine (calcium hypochlorite) having chlorine content upto 68% disinfect for water treatment complete all as specified & directed.
M&L for replacement of Unsv MBBR Media from the tank and supply of filling Fresh media of MBBR Media in the main reactor as specified of existing /suitable Make with the following specificatios:- Effective surface area of media Approx - 400 Sqm/Cum (b) Mesdia ht Approx - 15/10 mm (c)Media dia Approx- 22 mm (d) Weight per unit surface area approx -22 mm (e) Voidage - >093 gm/Cucm (g) Media fill Range - 25-55% of volume
M&L for replacement of Hybrid Bio-Cultured (Synthetic Bacteria) suitable for STP 250/300 Cum/day complete all as specified and directed .
Material and labour for replacement of activated carbon IV 1000, granular type complete all as specified and directed.
Supply and mixing of Dewatering Poly Electrolite 100 % Purity complete all as specified and directed. Make : ION Exchange/Rayal Seema/Aqua/Thermax
Supply and mixing Calcium Hydro-Oxide (Lime, 80-85%) in Powder form as pH Booster for STP water, packing in 40 Kg Packs complete all as specified and directed.
Supply and mixing Ortho Tolidin solution 500ml for testing of dissolved chlorine in water complete all as specified and directed.
Supply and mixing Chlorination testing glass test Tube kit complete all as specified and directed.
Supply and mixing Alum Ferric (Grade-4) (best quality as per sample) for purification of water (containing lead (as PB) 30 ppm Max and arsenic 6 ppm Max) confirming to IS-299/2012 (Revised) as amended upto date complete all as specified and ddirected by Engineer-in-Charge. (Note :- The Alumino Ferric Sulphate shall be supplied in superior quality bricks (slabs) as per IS specifications. Manufacturers Name/trade mark shall be engraved on each brick (slab) in addition to marking of relavant clause of IS specification).
Supply and mixing bacteria culture airobic in 30 Kg of drum complete all as specified and directed.
Supply and mixing DAP fertiliser for day to day use in sewage treatment plant complete all as specified and directed .
Supply and mixing molasses for day to day use in Sewage treatment plant complete all as specified and directed .
Supply and mixing PAC (Poly Aluminium Chloride AC 1005 in organic soluable Polymer Powder packed in 25 Kg Poly bags completed all as specified and directed.
Carrying sample for testing of treated water/raw water of STP and submission of detailed test report to the office of the Engineer-in-charge. Details are as under:- (a) carry ing out minimum essential testing of water as per IS 3025 & IS 1622 mandatory for chemical , colour, odour, PH value, TSS, BOD,COD, Total residual chlorine, total Nitrogen, sulphate, oil and grease, Ammonical nitrogen(NH3-N) and Bacteriological total coliform organism per 100ml (MPN) and Ecoli in 100ml (b) Treated sewage water shall confirm to the following characterstics:- (i) TSS : < 10 mg/litre (ii) BOD : < 10 mg/ litre (iii) COD: < 150 mg/litre (iv) Ph: 6.5 -8.5 (v) Total coliform: < 100 MPN/100 ml (desired nil) (vi) Resudual CI> 1 mg/litre Rest of the characterstic of the treated water shall be as per IS 3025 & IS 1622 Note:- Rate quoted shall also deemed to be included for:- (i) Cost of sterilized bottle as required (ii) To and fro Transportation charges for collection of sample (iii) Tests to be contracted through approved test lab or Govt approved Engg College.
M&L in replacement of pressure gauge to read in IS/BS unit type Range 0-7.5 KG/cm2 and LB/inc2 reading marked 0-2, 0-30 respectively including taking old one complete all as specified and as directed.
M&L for cleaning, scrapping out of surface and painting of all pipe lines dia upto 100mm with two coat of primer as approved colour with two coat of synthetic enameled paint complete all as specified and as approved.
M&L for cleaning, scrapping out side of vessel properly including painting with one coat zinc chrome primer & two coats of best quality synthetic enamel paint etc.
M&L for complete overhauling and repairing of multigrade Pressure sand filter/carbon activated filter including replacement of filter media with marble stone aggregate of size 1-5mm dia in diffrent and alternate layers not less than 100 height as per existing including other connected assessories as required at site of STP capacity of 250/300 KLD including testing complete all as specified and directed. Note: (1) Rate of filter membrane of any size, type, grading and quantity as per existing is deemed to be included in quoted rate. (2) Rate are deemed to be inclusive of lifting arrangement of vessel like hydra, T&P and labour required at site. (3) Repair of minor defect encounter during overhauling of sand filter media filter is deemed to be included in quoted rate. (4) Acid and other cleaning agent required for cleaning of inner surface of vessel is deemed to included in quoted rate. (5) Rate are deemed to be inclusive of uPVC fittings (any type, size and quantity) required at site for disconnecting and refixing vessels after overhauling. (6) Rate are deemed to inclusive of repair to vessel if any damage caused to vessel and fitting due to mishandling by labour during execution of work. (7) Contractor has to take sufficient safety measures for labour and user from toxic gas and material released from filters during over hauling. Deptt will not be responsible for any mishappening caused to labour or animal due toxic gases and material . Proper disposal of toxic material is responsibility of contractor. Note:- The rate is inclusive of replacement of filter media as per OEM under this item.
S&F in replacement Moulded case circuit Breaker of capacity , 400 Amps, 04 pole , 415 Volt, 36 KA Breaking capacity, with adjustable thermal & adjustable magnetic setting complete all as specified and directed.
M&L in replacement Moulded case circuit Breaker of capacity, 250 Amps, 04 pole, 415 V, 36 KA Breaking capacity, with adjustable thermal & adjustable magnetic setting complete all as specified and directed.
M&L in replacement MCCB 200 A, 4 Pole, 415 V, 36 KA Breaking capacity, with fixed thermal magnetic release complete all as specified and directed by Engineer-in-Charge. Make : Havells/Legrand/L&T
M&L in replacement MCCB 100 A, 4 Pole, 415 V, 25 KA Breaking capacity, with fixed thermal magnetic release complete all as specified and directed.
M&L in replacement Moulded Case Circuit Breaker (MCCB) (AC 415 V) with fixed thermal magnetic release 4 pole 63 Amp 16 KA complete all as specified and directed.
Dismantling the unserviceable part of sewage treatment compressor blower and replace with including testing after completion all as specified and directed .
S&F in Replacement Suction filter suitable for sewage treatment 250 KLD /300 KLD compressor blower complete all as specified and directed .
S&F in Replacement bearing suitable for sewage treatment 250 KLD/ 300 KLD compressor blower complete all as specified and directed
S&F in Replacement gears with Hub complete with hardware suitable for sewage treatment 250 KLD/300 KLD compressor blower complete all as specified and directed.
S&F in Replacement V- Belt suitable for sewage treatment 250 KLD/ 300 KLD compressor blower complete all as specified and directed.
S&F in Replacement gear oil No-90 suitable for sewage treatment compressor blower complete all as specified and directed.
S&F in Replacement oil seal and gasket set suitable for sewage treatment compressor blower for 250/300 KLD complete all as specified and directed .
S&F in Replacement Set of rotor with shaft for sewage treatment compressor blower for 250/300 KLD complete all as specified and directed.
S&F in replacement Silencer suitable for Everest Blower complete all as specified and directed.
M&L in replacement Jet mixer nozzles of size 25 mm for equilizer tank of STP complete all as specified and directed.
Supply and fixing in replacement of pre-fabricated MS structural steel (IS marked) work consisting of channels / angles /flats/ round bars/MS pipe & other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting for hanging strcture for repair bay all as directed.
S&F in replacement Submersible cable PVC insulated copper conductor flat 3 core 6 sqmm 1100 volt complete all as specified and directed.
S&F in replacement Direct on line submersible pump starter of capacity 7.5 HP (5.5 KW) current rating 18 Amp overload relay range 10-16 Amp complete all as specified and directed.
Supply and lay in replacement or fixing or passing through pipe cable XLPE with aluminium conductor with heavy duty stranded,1100 volts of following size. Note :-XLPE insulated pvc sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS -7098 (Part-I) for pvc insulated cables size 3 core 6 sqmm .
Supply & fix in replacement of Electronic timer 415 Volt, 50 Hz range 3-10 Secs complete all as specified and directed.
S&F in replacement of Single phase preventer 6 wire, 415V suitable for pumps starter as per ground reqirement, complete all as specified & directed.
S&F in replacement CI impeller suitable for Non clogging centrifugal pump 40 HP complete all as specified and directed .
All as per srl item no 45 above but 20 HP.
Lowering/Lifting/disconnecting the electric and water pipe connection for taking out burnt non clogging submersible pumping set of capacity upto 12.5 HP by using tripod & chain pulley arrangement from sewage sump at a depth of approx 18 feet by dismantling column pipe flanged joint for carrying out necessary repair including transportation of pumping set to civil work shop for repair and return to site after repair including testing all as specified and directed .
M&L for taking out the Non clogging submersible pump 12.5 HP from the motor and rewinding of motor with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint including replacement of following items:- (a) Replacement of both side ends cover and machining to size of ball bearing. (b) Replacement of driving and nondrying end ball bearing. (c) Balancing of rotor including straightening of strips. (d) Assembling of motor including replacement of copper lead.
All as per srl item no 48 above but 5 HP
All as per srl item no 48 above but 3 HP
Opening of Non-clogging Submersible pump 12.5 HP for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning complete all as directed. (a) Replacement of cast iron impeller. (b)Replacement of bearing plate. (c)Replacement of gun metal bush. (d) Replacement of oil seal.
All as per srl item no 51 above but 5 HP
All as per srl item no 51 above but 3 HP
S&F in replacement of Cast iron sluice valve of size 150 mm dia Stainless steel stem PN- 1.6 ( Flanged) conforming to IS 14846 hand wheel operated including taking down old one all as specified and as directed.
All as per srl item no 54 above but 100 mm
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25mm X 4 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, test point of phosphorous bronze / gun metal of size 75 mmx 75 mm x25 mm, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
S&F in replacement of cast iron NRV flanged end of size 100 mm dia with all fitting and accessories including taking down old one all as specified and as directed.
All as per srl item No 57 above but 80 mm dia.
S&F in replacement of CI Butterfly valve 50 mm dia with lever operated CI Disc Nitrile/EPDM Rubber Lining test pressure PN-1.0 and ms nut bolt and washers and pair of rubber/fibers required for the work will be supplied by contractor for fixing in position complete including taking down old one all as specified and as directed.
All as per srl item no 59 above but 80 mm
All as per srl item no 59 above but 100 mm
S&F in replacement of ball valve gun metal with iron wheel/handle screwed both ends for iron pipe and fixed of size 50 mm bore including taking down old one all as specified and as directed by Engr-in-Charge.Make- Zoloto/Audcu
Taking out compressor from 12.5 HP motor and rewinding of motor same gauge with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following items complete all as specified and directed by Engr-in- charge. (a) Replacement of ball bearing. Make: SKF-02 Nos (b) Replacement of cooling fan - 01 Nos.
Taking out the 40 HP centrifugal pump from the motor and rewinding of motor same gauge with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following items All as specified and directed by Engr-in- charge. (a) Replacement of ball bearing. Make: SKF-02 Nos (b) Replacement of cooling fan - 01 Nos.
All as per srl item No 64 above but 20 HP
All as per srl item No 64 above but 5 HP
All as per srl item No 64 above but 2 to 3 HP
Opening of pump centrifugal 40 HP for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning complete all as directed. (a) Replacement of gun metal impeller. -01 Nos (b) Replacement of gun metal bush -02 Nos (c) Replacement of ball bearing. Make: SKF - 01 Nos. (d) Replacement of oil seal -01 Nos. (e) Replacement of gland -01 Job
All as per srl item No 68 above but 20 HP
All as per srl item No 68 above but 5 HP
All as per srl item No 68 above but 2 to 3 HP
Supply and Fixing in replacement of UPVC pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-80, pressure rating 10kgf/ cm2 complete with all types of fittings, laid in trenches ,wall etc in required length complete all as specified and directed Engr-in-Charge of the inner bore sizes 25 mm dia.
Supply & laying in replacement of MS pipe ( Heavy duty Class 'c') including fitting as required of 100 mm dia pipe sizes laid in treches or laying oe floor for connecting to various STP accessories and to connect outgoing water main including taking down the unserviceable pipe and depositing to MES store yard all as directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate.
Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall floor with all GI fittings like tee, socket,reducer, elbows connections as required at site of size 15 mm bore complete all as specified and directed .
All as per Item No 74 Above but Bore of pipe 20 mm.
All as per Item No 74 Above but Bore of pipe 25 mm.
All as per Item No 74 Above but Bore of pipe 50mm.
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as specified.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specified and directed by Engr-in- charge.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr-in- charge.
Supply and laying in replacement of HDPE pipe 100 mm dia complete all as specified and directed by Engr-in-Charge. Make - ISI marked.
M&L for boring holes for laying of pipe manual bookey , of 200 mm dia 2 m deep in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc. 50 m Complete all as specified and as directed by Engr-in-Charge
S&F in replacement of lamella clarifier fiber settling plates of lamella clarifier suitable for 250KLD STP plant complete all as specified and directed by Engr-in-Charge.
S&F in repair foot valve of size 100mm dia (Plastic body) with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing unserviceable foo tvalve complete all as directed at site. Make:- Prince/Astral
All as per item No 84 herein before but for 80mm dia.
All as per item No 84 herein before but for 50mm dia.
M&L in replacement of Power contactor 3 pole Type CN5 50 AC 50 Amp rating complete all as specified and directed by Engr-in-charge.
M&L in replacement of Power contactor 3 pole Type MNX 32 AC 3 rating 32A complete all as specified and directed by Engr-in-charge.
Supply & fix in replacement of contactor, 3 pole, 415V, MNX 18/22/25 complete all as specified and directed by Engr-in-charge.
Supply & fix in replacement of Electronic overload relay (Manual reset) relay range 24-40 amp suitable for direct mountimg complete all as specified and directed .
Supply & fix in replacement of Electronic overload relay (Manual reset) relay range 9-16 amp suitable for direct mountimg complete all as specified and directed .
Supply & fix in replacement of Electronic overload relay (Manual reset) relay range 45-75amp suitable for direct mountimg complete all as specified and directed .
M&L in replacement for making Pump set foundation and pipe filling support from PCC 1:2:4, type B2, with 40mm graded stone aggregate,of any shape or size as indicated including grouting of foundation bolts of suitable dia and size as required on site complete all as specified and directed at site by EIC.
S&F in replacement of pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/clading to wall, fixed with self tapping screws and bending of sheet as required and as directed.
M & L in replacement for loose filling using 40 to 80 mm stone aggregate (granite) spread to a thickness of 150 mm for out door sub station complete all as specified and directed .
Supply and lay in replacement or fixing or passing through pipe cable XLPE with aluminium conductor with heavy duty stranded,1100 volts of following size. Note :-XLPE insulated pvc sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS -7098 (Part-I) for pvc insulated cables size 3.5 core 50 sqmm .
Supply and fix bricks subclass B designation 70, laid flat in trenches for protection of cable over LT cable complete all as specified and directed.
Supply and fill dry river sand in trenches for cable cushioning, complete all as specified and directed.
S&F in replacement motor cover made of FRP sheets 3mm thick in U shape with handle for lifting including fastner, nut bolts as required on site suitable for monoblock pumpset upto 5HP, complete all as specified & directed.
S&F in replacement of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) of size 63mm outer dia of pipe UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors or in trenches, complete all as specified and directed.
Schedule of Credit
Deepak Electricals
SRA Engineering
ANAND ENTERPRISES
M/S PARKASH ENTERPRISES
Rohan Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .