The Executive Engineer, B.D-II,P.W.D., Manipur
Office of the Executive Engineer, BD-II, P.W.D., Khuyathong, Manipur,
Reconstruction of Govt. Qtrs. Type-V/F No.2 at Sanjenthong Officers Colony.
2021_PWDM1_1519_1
EE/BD-II/etender/2021-22/05
Open Tender
Civil Works
Item Rate
365 days
Sanjenthong Officers Colony
EMD, Tender Fee, GST Registration, Enlistment order of the contractor and all other documents mentioned in NIT.
3 documents required · 3 mandatory
₹10,000
EE, Building Division No.II, P.W.D., Manipur
₹2.1 L
20 Sept 2021
2 Sept 2021
20 Sept 2021
2 Sept 2021
20 Sept 2021
2 Sept 2021
120 days
Amount
SH:Construction of Main Building :
Earth work in Excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a) Hard / Dense soil.
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Filling with sandy soil under floors including watering, ramming, consolidating and dressing complete .
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size).
Reinforcement for RCC work i/cbending, binding and placing in position complete. (a) Thermo-mechanically treated bars steel bars.
Providing form work i /c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in
a) Foundation, footing, bases of columns etc. and mass concrete.
(b) Columns, pillars, post and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunching, cantilevers, girders bressumers and lintel (Not exceeding 1.0 m. in depth).
(d) Flat surface such as suspended floors upto 200 mm. thickness.
(e Edges of slabs and bricks in floors and walls. (Under 20 cm. Wide).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering and reinforcement. All work up to plinth level. (A) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string Coarses, fillets, columns, pillars, piers, abutment, posts and struts upto floor two level excluding the cost of centering, shuttering finishing. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roof having slope up to 15 degree landing balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of shuttering and reinforcement. with (a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
2nd Class (Local first class) brick work in foundation & plinth with cement mortar 1:3 (1 cement: 3 Coarse sand).
2 nd class (local first class) brick work in superstructure with cement mortar 1:3 (1 cement: 3 Coarse sand). (Rectangular Column)
Half brick masonry 2 nd class (local first class) in cement mortar 1:3 ( 1 cement: 3 Coarse sand) in Superstructure.
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought, framed and fixed in position Local best quality Teak wood
P/F 50 mm. thick paneled glazed or paneled and glazed shutters for doors and windows, c/ windows i/c bright finished or black enameled M.S. iron butt hinges with necessary screws. A) Local best quality Teak wood.
Providing & fixing MS round Providing & fixing MS round or square bars at required spacing in windows frame of window & c / window.
Providing and fixing Brass sliding bolts bright finished or/and black enameled with nuts and screws etc, complete. a). 300 x 16 mm.
Providing and fixing Aluminium Tower bolts (barrel type) with screws etc. complete
Providing and fixing Aluminium handles with necessary screws etc. complete. a) 125 mm.
Providing and fixing M.S. Hooks & eyes a) 150 mm.
Supplying door & window clamps with 40 mm x 6 mm F.B. 80 cm long i/c. bends.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. b) Size of tile 600 x 600 mm (Double charged) i)Non-Branded.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorbsin less than 0.08 % and conforming to IS 15622 of approved make in ll colours & shade in skirting, risers of steps over 12 mm. thick bed of cement mortar 1:3 (1 cement: 3 Coarse sand) including grouting the joint with white cement & matching pigments etc. complete. b) Size of tile 600 x 600 mm (Double charged) i)Non- Branded.
Providing and laying rectified(Non-skid) Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
White glazed tiles 10 mm thick in skirting risers of steps & dado on 10 mm thick cement plaster 1:3 (1 cement:3 coarse sand) & jointed with white cement slurry. (20 x 30 cm size)
15 mm cement plaster 1:3 (1 cement : 3 Coarse sand).
12 mm cement plaster 1:3 (1 cement : 3 Coarse sand).
15 mm cement plaster 1:3 (1 cement : 3 Coarse sand) with a floating coat of neat cement.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Painting (two or more coats) with plastic emulsion paint of approved quality on new work except walls to give an even shade.
Finishing walls weather shield paint of approved quality on new work (three or more coats) to give even shade.
Providing & fixing 25 x 25 mm Uningthou wood balusters 25 mm x 25 mm square, wrought fixed with ends housed (square or splay) to hand rails and tread or strings complete.
Providing anf fixing 75 mm x 60 mm moulded hand rails in straight lengths complete in Uningthou wood.
Applying ready mixed priming coat pink primer of approved quality on new wood work.
Painting two coats (excluding priming coat) with chocolate, red, grey or buff paint of approved quality on new steel or wood work.
Painting (one or more coats) with black Japan to give an even shade.
Varnishing (two or more coats) with superior Copal varnish of approved quality i/c sizing on new work.
Providing under layer for plinth protection of 75 mm. thick rammed and consolidated and grouted with fine sand i/c preparation of ground.
Providing Plinth protection 50mm thick in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggrt. 20mm nominal size) including finishing the top surface of concrete smooth.
Construction of 2 nd class brick masonry 150 mm wide open surface drain in cement mortar 1:3 ( 1 cement: 3 Coarse sand ) finished with a floating coat of neat cement.
Providing and fixing white vitreous China pedestal type water closet (Euopean type W.C. pan) with seat and lid 10 litres low level white vitreous china flushing cistern & C.P. flush bend with fitting & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fitting and brackets, cutting and making good the wall and floors wherever required: A. W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing lead chaulked joints to 100 mm HCI pipes.
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings: 1) Flat back wash basin of size 630 x450 mm.
Providing and fixing C,P. brass bib cock of approved quality conforming to IS:8931: A. 15 mm dia. Ordinary.
Providing and fixing 100 mm HCI soil, waste & vent pipes.
Providing and fixing MS holder bat clamps of approved design to 50 mm HCI pipe sockets i/c cost of cutting holes and making good the walls etc.
Providing and fixing GI pipes complete with GI fittings and clamps i/c cost of cutting and making good the walls etc. (Internal works).
a) 15 mm dia.
b) 25 mm dia.
Providing and fixing 100 x 100 x 100 mm HCI branch of the required degree with access doors, insertion rubber washer 3 mm thick bolts and nuts complete.
Providing and fixing CP brass shower rose with 12.5 mm or 19 mm inlet a) 100 mm diameter.
Providing and fixing telephonic shower rose with one meter flexible tube, Dimple / Round / Fancy.
Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleat with CP brass screws and washers complete.
Providing and fixing 610 x 20 mm diplomat brass towel rail complete with CP brass brackets fixed to wooden cleat with CP brass screws.
Providing and fixing soap container of glass with CP lid & brackets fixed to wooden cleat with CP brass screws.
Providing and fixing 600 x 120 mm glass shelf ( Indian make) with CP brass brackets guard nail complete fixed to wooden cleat with CP brass screws.
Providing and fixing 100 mm HCI colar.
Providing and fixing C,P. brass stop cock (concealed) of standard design and of approved make conformimg to IS:8931. A. 15 mm nominal bore
SH : Septic tank. ( 25 Users)
Earth work in Excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. a) Loose/Soft Soil.
P/L cement concrete in foundation and plinth excluding the cost centering and shuttering. (a) 1:4:8 (1 cement : 4 coarse sand : 8graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering and reinforcement. All work up to plinth level. (A) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string s, fillets, columns, pillars, piers, abutment, posts and struts upto floor two level excluding the cost of centering, shuttering finishing. 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing form work i /c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in
a) Foundation, footing, bases of columns etc. and mass concrete.
(b) Flat surface such as suspended floors upto 200 mm. thickness.
(c) Sides soffits of beams, beam haunching, cantilevers, girders bressumers and lintel (Not exceeding 1.0 m. in depth).
(d) Edges of slabs and bricks in floors and walls. (Under 20 cm. Wide).
Reinforcement for RCC work i/cbending, binding and placing in position complete. (a) Thermo-mechanically treated bars steel bars.
Reinforced cement concrete work in beams, suspended floors, roof having slope up to 15 degree landing balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of shuttering and reinforcement. with (a) 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Half brick masonry 2 nd class (local first class) in cement mortar 1:3 ( 1 cement: 3 sand) in Superstructure.
15 mm cement plaster 1:3 (1 cement : 3 sand) with a floating coat of neat cement.
Providing and fixing C.I cover with frame (for manhole and chambers) a) 600 x 450 mm (light duty) (25kg)
Providing & fixing 100 mm HCI terminal guard.
Providing & fixing 100 mm HCI Collar.
Providing and fixing HCI traps with 100 mm inlet and 100 mm outlet of self cleaning design with HCI screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
Md. Abdul Kashim
stage.html
html • 0.02 MB
finance_1682.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .