Loading…
Loading…
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
3 Jul 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Experience in similar nature of work:- a) The tenderer must have successfully completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar nature of works each costing not less than the amount equal to 30% of the advertised value of the tender, or Two similar nature of works each costing not less than the amount equal to 40% of the advertised value of the tender, or One similar nature of work each costing not less than the amount equal to 60% of the advertised value of the tender. (b) (i) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. And in the case of major bridges - substructure, superstructure etc.), the tenderer must have successfully completed any of the following during last 07 (seven) years, ending the last day of the month previous to the one in which tender is invited: Three similar nature of works each costing not less than the an amount equal to 30% of the advertised value of each component of the tender, or Two similar nature of works each costing not less than the amount equal to 40% of the advertised value of each component of tender, or One similar nature of work each costing not less than the amount equal to 60 % of the advertised value of each component of the tender. Note for b(i): Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly predefined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of the tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility shall be considered. The scope of work covered in other remaining components shall be either executed by the tenderer himself if he has work experience as mentioned in clause 7 (a) (ii) of Part-II of GCC or through subcontractor fulfilling the requirements as per clause 7 of Part-II of GCC or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfillment of technical eligibility. In case after the award of the contract or during the execution of work it becomes necessary for the contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of Part-II of GCC, with prior approval of the Chief Engineer in writing.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work"
Tenderer must have to submit valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by Government Electrical License Board on or before the closing date of tender. Copy of the electrical contractor license should be submitted along with the tender offer, otherwise, the tender will be summarily rejected.
51 conditions · 4 needing a document upload
Whether the cost of earnest money deposited
WHETHER VALID ELECTRICAL CONTRACTOR LICENCE AND SUPERVISOR LICENCE SUBMITTED
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
Augmentation & Upgradation by AB Cable installation to stop pilferage of electricity at Rest Camp, Replacement of ACSR by MVCC Cable for 11 KV HT Feeder, rest camp feeder, Augmentation of Water supply & upgradation of substation under SSE/P/PNO, NGC, KYQ & GHY.
EL-LM-26-27-04
EL-LM-26-27-04
Open
Works - General
120 Days
Hojai, Assam
₹0
₹6.0 L
3 Jul 2026
3 Jun 2026
19 Jun 2026
72 items across 4 schedules · ₹67,17,408.56 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Stringing, sagging, laying and commissioning of LT Aerial Bunched Cable (ABC) comprising 3 x 50 Sq.mm Aluminium Phase Conductors + 1 x 35 Sq.mm Aluminium Alloy Messenger (Neutral) Conductor + 1 x 16 Sq.mm Street Lighting Conductor, complete with running out, paying out, tensioning, sagging, clipping and fixing on pole-mounted suspension clamps, dead-end clamps and associated hardware. The work shall include loading, unloading, transportation, handling and carrying of cable from Railway store/stacking point to actual work site by contractor's own arrangement. The cable shall be strung using approved tools and techniques to avoid damage to insulation and conductors. Proper sag shall be maintained as per manufacturer's recommendations, relevant standards and site conditions. The work shall also include: Running out of cable along the alignment, Stringing through suspension and anchoring arrangements ,Maintaining proper tension and sag, Crossing roads, tracks, drains and other utilities safely ,Alignment and dressing of cable, Jointing, if required, through approved accessories (separately measured unless otherwise specified),Testing of insulation resistance and continuity after installation. The work shall be executed as per relevant IS/IEC specifications, utility practices and the direction of the Engineer-in-Charge. | Metre | 2700.00 | 36.89 | 99,603 |
| 2 | Supply of hot-dip galvanized steel tubular pole, 9.0 metre long, Type 410 SP-33, having step lengths of 5.0 m + 2.0 m + 2.0 m, sectional outside diameters of 165.1 mm x 139.7 mm x 114.3 mm and wall thicknesses of 5.4 mm x 4.5 mm x 3.65 mm respectively, complete with welded base plate and top cap. The pole shall conform to IS 2713 (Part-II):1980 or latest amendment. The steel tubes used for manufacture shall conform to IS 1161 and/or IS 1239 and shall be hot-dip galvanized as per relevant IS standards. The pole shall be designed to withstand wind loads in accordance with IS 875 (latest edition). The item shall include supply of anti-climbing device consisting of barbed wire arrangement up to 2.5 metres height from ground level complete with GI clamps, nuts, bolts and all accessories. The pole shall also be provided with a danger board of size 200 mm x 150 mm (8" x 6"), fixed with suitable GI clamps, displaying voltage grade, skull symbol and caution markings as per IE Rules and statutory requirements. The item shall be supplied complete in all respects with all hardware, fittings and accessories required for satisfactory installation as per the direction and approval of the Engineer-in-Charge. | Numbers | 57.00 | 24,528.66 | 13,98,133.62 |
| 3 | Erection of rail/tubular pole by embedding the pole to a depth of one-fifth (1/5th) of its total length in the ground, including excavation of pit of suitable dimensions, dressing, ramming and refilling of excavated earth. The foundation shall consist of a PCC base block of size 300 mm x 300 mm x 150 mm using cement concrete in the proportion of 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate of 19 mm and down size). The excavation and foundation work shall be carried out as per approved drawing and standard engineering practice. After erection, the pole shall be properly aligned, plumbed and consolidated by refilling and compacting the excavated earth. The finished foundation shall extend up to 300 mm above ground level to prevent water accumulation around the pole base. All labour, tools, plants, excavation, dewatering (if required), transportation of materials, curing of concrete and incidental works necessary for satisfactory completion of the work shall be included in the item. The work shall be executed complete in all respects as per relevant IS specifications, Railway standards and the direction of the Engineer-in-Charge. | Numbers | 57.00 | 1,374.68 | 78,356.76 |
| 4 | Supply, erection, testing and commissioning of LT stay setcomplete with 7/14 SWG stay wire, Anchorplate, Thimble, Bow, 18 inch strainingscrew, LT guy insulator and 19 mm dia, 1.8metre long LT stay rod. LT stay rod shall beburied underground by digging of earth toa depth of 6x1x1 feet and concreting thesame with 1:2:4 concrete upto the heightof 1 feet above the ground level. LT guyinsulator shall be provided at a height of12 feet vertically above the ground level. | Set | 30.00 | 379.1 | 11,373 |
| 5 | Supply and fixing of LT Suspension Clamp Assembly suitable for supporting and suspending bare/insulated messenger conductor of LT Aerial Bunched Cable (ABC) system, comprising of 1 No. suspension clamp, 1 No. mounting bracket, 1.5 metre long stainless steel strap, 2 Nos. stainless steel buckles, and all associated accessories required for complete installation. The suspension clamp shall be manufactured from high-strength weather- resistant polymer/engineering grade material with hot-dip galvanized or corrosion-resistant metallic parts suitable for outdoor use under all weather conditions. The clamp shall be capable of supporting the messenger conductor without causing damage to the conductor strands or insulation and shall provide adequate mechanical strength as per standard requirements. The item shall include supply, fixing, tightening, alignment, testing and commissioning complete with all labour, tools, tackles and accessories required for satisfactory installation on poles at site as per the direction of the Engineer-in-Charge. | Numbers | 110.00 | 341.53 | 37,568.3 |
| 6 | Supply and fixing of I-Hook for Anchor suitable for mounting of suspension clamp/dead-end clamp assembly on RCC, PSC, steel tubular or rail poles for LT Aerial Bunched Cable (ABC) system. The I-Hook shall be manufactured from forged steel or hot-dip galvanized mild steel of adequate mechanical strength and corrosion resistance, complete with nuts, washers and all necessary fixing accessories. The I-Hook shall be designed to withstand the mechanical load imposed by the messenger conductor and associated fittings under normal and adverse operating conditions without deformation or failure. The item shall include supply, installation, tightening and fixing complete in all respects, including all labour, tools, tackles and accessories required for satisfactory execution of the work as per the direction of the Engineer- in-Charge. | Numbers | 115.00 | 95.2 | 10,948 |
| 7 | Supply and fixing of Anchoring Dead-End Clamp Assembly suitable for anchoring bare/insulated messenger conductor of LT Aerial Bunched Cable (ABC) system, comprising of 1 No. anchor/dead-end clamp, 1 No. universal bracket, stainless steel strap, stainless steel buckles, fixing hardware and all associated accessories required for complete installation. The dead-end clamp shall be made of high-strength UV- resistant weatherproof polymer with corrosion- resistant metallic components and shall be suitable for outdoor installation under tropical environmental conditions. The clamp shall securely grip the messenger conductor without damaging the conductor strands or insulation and shall be capable of withstanding the specified mechanical tensile load of the messenger conductor. The universal bracket and associated hardware shall be manufactured from hot-dip galvanized steel or equivalent corrosion- resistant material.The item shall include supply, fixing, tightening, testing and commissioning complete with all labour, tools, tackles and accessories required for satisfactory installation at site as per the direction of the Engineer-in- Charge. | Numbers | 22.00 | 396.27 | 8,717.94 |
| 8 | Supply of Insulation Piercing Connector (IPC) suitable for tapping/branching of street lighting circuits and earthing connections from LT Aerial Bunched Cable (ABC) system without removal of conductor insulation. The connector shall be designed to provide a reliable electrical connection through insulation piercing technology and shall be suitable for outdoor installation under all weather conditions. The item shall include supply, fixing, testing and commissioning complete with all accessories, labour, tools and tackles required for satisfactory installation as per manufacturer's recommendations and the direction of the Engineer-in-Charge. | Numbers | 100.00 | 159.46 | 15,946 |
| 9 | Supply, installation and commissioning of Insulation Piercing Connector (IPC) suitable for LT Aerial Bunched Cable (ABC) system up to 1.1 kV grade for phase-to-phase, phase-to-neutral without removal of conductor insulation. The connector shall be designed to establish a reliable electrical connection by piercing the conductor insulation and shall be suitable for outdoor installation under tropical environmental conditions. The connector shall ensure low contact resistance, moisture-proof operation, adequate mechanical strength and long service life. Tightening shall be through controlled torque shear-head bolts to ensure proper electrical contact.The item shall include supply, installation, tightening, testing and commissioning complete with all labour, tools, tackles and accessories required for satisfactory operation as per manufacturer's recommendations and the direction of the Engineer-in-Charge. | Numbers | 295.00 | 130.11 | 38,382.45 |
| 10 | Supply, installation and commissioning of Tamper Proof Spring Loaded Distribution Service Connection Box suitable for providing distribution and service connections to 12 Nos. single-phase consumers, complete with incoming and outgoing terminals, spring-loaded connectors, busbars, neutral link, earthing arrangement, gland plates, locking arrangement and all associated accessories required for safe and reliable operation. The enclosure shall be manufactured from high-quality UV-stabilized, flame-retardant, weatherproof and impact- resistant SMC/FRP/Polycarbonate material, suitable for outdoor installation. The box shall be dust-proof, vermin-proof and moisture-resistant, with minimum protection degree of IP-54. The service connection box shall be designed to prevent unauthorized access and electricity theft and shall have provision for sealing by the utility.The item shall include supply, mounting on pole/wall structure, internal wiring, termination, testing and commissioning complete with all labour, tools, tackles, transportation and accessories required for satisfactory operation as per the direction of the Engineer-in-Charge. | Numbers | 20.00 | 3,433.15 | 68,663 |
| 11 | Supply, installation and commissioning of Tamper Proof Spring Loaded Distribution Service Connection Box suitable for providing distribution and service connections to 6 Nos. single-phase consumers, complete with incoming and outgoing terminals, spring-loaded connectors, busbars, neutral link, earthing arrangement, gland plates, locking arrangement and all associated accessories required for safe and reliable operation. The enclosure shall be manufactured from high-quality UV-stabilized, flame-retardant, weatherproof and impact- resistant SMC/FRP/Polycarbonate material, suitable for outdoor installation. The box shall be dust-proof, vermin-proof and moisture-resistant, with minimum protection degree of IP-54. The service connection box shall be designed to prevent unauthorized access and electricity theft and shall have provision for sealing by the utility.The item shall include supply, mounting on pole/wall structure, internal wiring, termination, testing and commissioning complete with all labour, tools, tackles, transportation and accessories required for satisfactory operation as per the direction of the Engineer-in-Charge. | Set | 50.00 | 2,437.12 | 1,21,856 |
| 12 | Supply, installation and commissioning of 20 mm wide stainless steel (SS) strap complete with 02 Nos. stainless steel buckles of suitable size for mounting and fixing of distribution boxes, service connection boxes, junction boxes and other electrical accessories on steel tubular poles, rail poles, PSC poles or similar structures. The stainless steel strap shall be manufactured from Grade SS 304 or higher, having adequate tensile strength, corrosion resistance and durability suitable for outdoor applications under all weather conditions. The buckles shall be compatible with the strap and capable of securely holding the mounted equipment without slippage or deformation. The item shall include cutting, positioning, tightening, fastening and fixing of the strap and buckles complete with all labour, tools, tackles and accessories required for satisfactory installation as per the direction of the Engineer-in-Charge. | Set | 150.00 | 291.55 | 43,732.5 |
| 13 | Dismantling of existing unserviceable, damaged and corroded ACSR conductor, guard wire, brackets, clamps, insulators, binding materials and other associated overhead line fittings from poles/structures at any height, including removal, lowering, coiling, stacking and handling of released materials without causing damage to reusable materials and nearby installations. The work shall include necessary precautions for safety of personnel, railway assets and public property, including shutdown coordination wherever required. All dismantled materials shall be properly segregated, measured, accounted for and transported to the nominated Railway store/depot or the office of the concerned Supervisor. The released materials shall be handed over in full quantity under proper challan and acknowledgement obtained from the concerned Railway Supervisor. Necessary entries shall be made in relevant records as directed by the Engineer-in-Charge. The contractor shall be responsible for safe custody of dismantled materials until their official handover.The item includes all labour, tools, tackles, ladders, transportation within Railway premises, loading, unloading and all incidental works required for complete execution of the work as per the direction of the Engineer-in- Charge. | Each Span | 100.00 | 101.98 | 10,198 |
| 14 | Supply, installation and commissioning of pre- insulated mid-span joint suitable for jointing of damaged/cut phase and neutral conductors, complete with all accessories required for making a reliable electrical and mechanical joint. Each set shall consist of: 03 Nos. pre-insulated compression/jointing sleeves/lugs suitable for phase conductors, and 01 No. pre-insulated compression/jointing sleeve/lug suitable for neutral (messenger) conductor, complete with insulating sleeve, jointing accessories and consumables. The joint shall be suitable for conductor sizes as specified at site and shall ensure proper electrical continuity, mechanical strength, insulation integrity and weather resistance. The insulation shall be UV-resistant, moisture-proof and suitable for outdoor service conditions. Jointing shall be carried out using appropriate compression tools recommended by the manufacturer.The item shall include supply of all materials, jointing, installation, testing and commissioning complete with labour, tools, tackles and accessories required for satisfactory completion of the work as per the direction of the Engineer-in-Charge. | Set | 25.00 | 719.95 | 17,998.75 |
| 15 | Supply, laying and commissioning of 2 Core x 16 Sq.mm PVC insulated and PVC sheathed aluminium stranded twisted service cable, 1100 V grade, complete with supply and stringing of 1 No. 6 SWG GI support wire and lacing/binding of the cable to the GI wire at intervals not exceeding 2.0 metres using suitable PVC ties, aluminium binding wire or approved fastening arrangement. The cable shall be drawn from the service pole to the consumer's service pipe/building connection point, including all accessories required for complete installation. The cable shall be weatherproof, suitable for outdoor service connection and capable of withstanding normal mechanical stresses encountered during installation and operation. The item shall include supply of cable, GI support wire, binding materials, saddles, clamps, fixing accessories, stringing, laying, termination, testing and commissioning complete with all labour, tools, tackles, transportation and incidental materials required for satisfactory completion of the work as per the direction of the Engineer-in-Charge. | Metre | 1500.00 | 60.59 | 90,885 |
| 16 | Supply, fixing and installation of 6 SWG Galvanized Iron (GI) Wire for strengthening, supporting and securing service connection cables, LT distribution cables and other electrical installations at various locations. The GI wire shall be adequately tensioned and fixed with suitable clamps, hooks, binding wire, saddles and other necessary accessories as required for proper mechanical support of the cable installation. The GI wire shall be hot-dip galvanized, free from joints, rust, defects and surface irregularities, and shall possess adequate tensile strength to withstand the mechanical load of the supported cable under normal operating conditions. The wire shall be installed in a neat and workmanlike manner as directed by the Engineer-in-Charge.. | Metre | 800.00 | 30.94 | 24,752 |
| 17 | Supply, installation, testing and commissioning of 45 Watt, 230V, 50Hz, energy-efficient outdoor LED Street Light Luminaire suitable for roadways, service roads, circulating areas, colonies and other outdoor applications, complete with mounting arrangement, connecting lead, fixing accessories and all associated materials required for satisfactory operation. The luminaire shall be of robust construction with pressure die-cast aluminium housing, powder-coated for corrosion resistance and provided with heat-resistant toughened glass cover. The luminaire shall be suitable for outdoor installation with a minimum degree of protection of IP-66 and Class-I electrical protection. The LED driver shall be inbuilt and designed for reliable operation under fluctuating supply conditions. The luminaire shall have a system efficacy not less than 105 lumens per watt, power factor greater than 0.95, THD less than 10%, and minimum surge protection of 5 kV. The LEDs shall have a minimum rated life of 50,000 burning hours at L70 performance level. The luminaire shall provide uniform illumination ensuring enhanced visibility and safety during night hours, particularly for persons with low vision. The item shall include supply, mounting, wiring, termination, testing and commissioning complete with all labour, tools, tackles and accessories as per the direction of the Engineer- in-Charge. | Numbers | 50.00 | 3,835.83 | 1,91,791.5 |
| 18 | Supply, fitting, fixing, testing & commissioning of Earthing complete with 50mm dia, 3.65mm thick , 4 mtr long GI pipe to be erected inside an earth pit of height 3.75 mtr& diameter 30 cm to be filled by alternate layers of salt (2) & charcoal (3) of width 50 cm each from the bottom and the rest by earth. Perforated holes of dia 12 mm each to be made in the pipe by drilling and a gap of 30 cm is to be maintained between the holes up to a height of 2.5 mtr from bottom. A second layer of perforated holes of same dimension are also to be made at an angle of 90o with the earlier layer of holes by keeping a vertical distance of 15 cm. A cement concrete chamber of size 30x30x30 cm and thickness 6 cm in ratio 1:3:6 by cement sand & 19mm and down stone chips is to be made around the pipe. The size of CC top cover is 24cmx24cmx4cm with provision of metallic folding handle is to be made. The cover to be provided on the 3mm top groove of earth pit (flash) as per direction of Railway Engineer. Earth continuity by 25x 5mm GI strip through alkathene pipe.75x16 mm GI nut, bolt and spring/flat washer has to be provided as per instruction of Railway Engineer. The connection of earth continuity wire with earth electrode to be made by GI soldering terminal socket of suitable size. The distance of earth electrode form building/other earthing system to be maintained by observing IE rules. As per Drg.No. : PCEE/ELG/DRG/2024/1/Rev-1 dated 28.07.2025 & as per Technical circular no.EL/PS/2025/1 (Pipe Earthing arrangements) | Numbers | 50.00 | 1,609.8 | 80,490 |
| 19 | Supply and fixing of GI Pole Clamp made out of 25 mm x 6 mm MS flat, fabricated to suitable size for fixing on steel tubular poles, complete with drilling of holes, bending, shaping and hot- dip galvanization. The clamp shall be suitable for mounting of service connection boxes, junction boxes, stay wires, cable supports, brackets, danger boards, earthing strips and other electrical accessories on tubular poles. The item shall include supply, fitting, fixing, tightening and installation complete with all labour, tools, tackles and accessories required for satisfactory execution of the work as per the direction of the Engineer-in-Charge. | Numbers | 100.00 | 151.13 | 15,113 |
| Schedule total | ₹23,64,508.82 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-LM-26-27-04final_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .