Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.0 L+₹1.7 L (7.29%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L2 | Rejected-Finance Rejected due highest rate quoted | |
| 3 | L3₹28.6 L+₹5.3 L (22.8%)Rejected-Finance | L3 | Rejected-Finance Rejected due highest rate quoted | |
| 4 | L4₹28.7 L+₹5.4 L (23.1%)Rejected-Finance | L4 | Rejected-Finance Rejected due highest rate quoted | |
| 5 | L5₹34.8 L+₹11.5 L (49.2%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L5 | Rejected-Finance Rejected due highest rate quoted |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
24 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) GURGAON
GE (AF) GURGAON
ADDN ALTN TO BUILDING NO P 41 AT AF STN ARJANGARH UNDER GE AF GURGAON
2023_MES_634580_1
GE/GUR-/NIT-57/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹86,000
5 Mar 2024
27 Dec 2023
26 Jan 2024
27 Dec 2023
24 Jan 2024
10 Jan 2024
Amount
Taking down cement or cement lime plaster on stone/brick wall, ceiling incl raking out joints, hacking for key, scrubbing down with water etc, including removal of rubbish outside MoD land and necessary scafolding upto 4th mtr. complete all as specified and as directed.
M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished fair and even, complete all as specified and as directed .
M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) finished even and smooth without using extra cement, complete all as specified and as directed.
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as specified and as directed.
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed.
Material and labour, Gunniting to existing RCC Chajja, facia, parapet, beams, landings and similar RCC members after removing all loose concrete & preparations of surface, application of derusting chemical such as Dr Fixit Rust Remover or equivalent, welding additional bars/welded steel wire fabric if found necessary, priming reinforcement bars with a coat of zinc primer of coating not less than 40 micron, provision of bonding agent with bonding material like Dr Fixit bonding agent and repair to external RCC structure with slurry light and steel/ply form work and shortcrete concrete of mixed 1:3:1 (one part of cement, three part of coarse sand and one part of 10mm and down aggregate) of minimum 50mm thick incl plastering 5 mm thick in CM mortar 1:3 all as specified in IS 9012-1978 (all priming and bonding epoxy based paint shall be of Dr Fixit epoxy zinc primer or equivalent) etc complete all as specified and as directed, as below:- Note(s) : 1. The rates include for necessary formwork and scafolding etc. 2. Reinforcement and welded steel wire fabric shall be measured and paid separately.
Supply only TMT steel bars for reinforcement in required length and dia, complete all as specified and as directed.
Supply only welded steel wire fabric, weight not exc 4kg/sqm, complete all as specified and as directed.
M&L for Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of single side prelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification complete all as specified and as directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet & reinforced with MS square tube and fixing in opening as specification & drawing, complete all as specified and as directed.
S&F, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel frames with tinned tacks, or galvanized wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and as directed.
S & F 3mm thick Sheet glass ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and as directed. Note:- New steel required for glazing glass in steel window shall be paid for separately.
S & F aluminium handle cast type anodised, 125 mm long complete all as specified and as directed.
S & F aluminium, anodised, barrel tower bolt of extruded section, ISI marked, 150mm long complete all as specified and as directed.
S & F Mild Steel butt hinges, medium weight 100mm size complete all as specified and as directed.
M&L for Cutting hole in brick wall built in cement mortar exceeding half brick but not exceeding one brick and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B – 1 complete all as specified and as directed.
M&L for factory made box type steel window with pintol hinges & 2 Nos 100mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and as directed.
S&F framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars barred iron doors, ladders, framed balusters, walkways, railing, frame work of water tanks, grills to balconies fixed to RCC/ brick walls and similar work complete all as specified and as directed.
M&L for , 18-20 mm thick machine cut kota stone slab as in flooring, steps of stair(treads), set with neat grey cement slurry @ 3Kg/Sqm, laid over and including 20mm thick cement and sand mortar (1:6) screed bed/bedding layer, jointed with grey cement slurry mixed with pigment to match the sahde of the slab including rubbing and polishingincl dismantl ing damaged stone slab of any description complete all as specified and as directed.
M&L, machine cut kota stone slab 18-20mm thick as in skirting/dado, riser of steps, laid over and including 10mm thick backing coat in CM (1:4), set in neat grey cement slurry @ 3Kg/Sqm, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed.
M&L for, Non-skid ceramic white tiles, 7 to 8 mm thick (square/rectangular) of size 300 x 300 mm , in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for First quality, Non skid ceramic white tiles 8 to 10 mm thick (square or rectangular) of size 600 x 600 mm, laid in floors set and jointed with neat cement slurry over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed.
M&L for First quality, Non skid ceramic white 8 to 10 mm thick (square or rectangular) of size 600 x 600 mm, on vertical surface set over and including 10 mm thick rendering with cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed.
M & L for first quality white glazed ceramic, tiles fixed in pattern of different colour including border of size 300x450x7 mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed. Note :- Pattern of the tiles shall be decided by GE at the time of execution.
Dismantling/removing old damaged worn out APP of any thickness incl screed bed or plastering of any thickness and removing the rubish materials outside MOD land at a dumping place earmarked marked by any state govt/municipalities etc any distance complete all as specified and as directed.
M&L for 15 mm thick screed bed in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 150 ml by per bag of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately.
Supply only Integral water proofing compound complete all as specified and as directed.
M&L for, water proofing treatment of roof consisting as under:- (a) Applying a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of primer @ 0.30 litre/ sq.m including preparation of roof surfaces (b) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions complete all as specified and as directed.
All as per Srl item No. 30 hereinbefore but on vertical surfaces, using hot blown bitumen having penetration value 30/40 applied 1.20 Kg/ Sq.m over primer @ 0.30 litre/ Sq.m, complete all as specified and as directed.
M&L for Preparation of old steel painted surfacesl of any description over 10cm width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc , filling in crevices and cracks etc with approved filler and applying two coats of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and as directed.
M&L for preparation of new decorated surface of walls and applying two coats of exterior emulsion (any colour) paint over a coat of primer of same manufacturer to achieve uniform and smooth surface using roller brush complete all as per manufactures instructions, specified and as directed.
M&L for preparation of old decorated surface of walls and applying two coats of exterior emulsion (any colour) paint over a coat of primer of same manufacturer to achieve uniform and smooth surface using roller brush complete all as per manufactures instructions, specified and as directed.
S&F in repairs 19 mm dia Aluminium curtain rod with powder coated along with ornamental attachment at both ends and one set of ornamental decorative MS clamps to fixed to walls complete all as specified and as directed.
M&L for Preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc , filling in crevices and cracks etc with approved filler and applying two coats of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and as directed.
M&L for preparation of new surfaces of steel or iron work of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer on steel surfaces complete all as specified and as directed.
M&L for Preparation of newly plastered surfaces of wall and applying two coat of Cement Base Paint of approved colour and shade by accepting officers over and including a coat of primer as per manufacturers instructions complete all as specified and as directed including necessary scafolding upto 4th floor.
M&L for preparation of new plastered surfaces and apply two coat of oil bound distmper over a coat of primer, complete all as specified and as directed.
M &L for preparation of newly plastered surface of ceiling and applying two coats of white wash complete all as specified and as directed.
M & L for preparation for old plastered surfaces on walls and applying two coats of cement base paint complete all as specified and as directed.
M&L for preparation for old surfaces on wall and applying two coats of oil emulsion paint (white or tinted) over a coat of primer with chalk whiting on plastered surfaces complete all as specified and as directed.
M&L for preparation of old surfaces on ceiling including cornices pilasters steel scrappers , wire brushing, and efforescent salts and treating oil and greasy spots and applying two coat of white wash on ceilling complete all as specified and as directed.
Taking down steel tubing/ PVC 15mm bore and connections including cleaning for refixing or removing to stores complete all as specified and as directed.
All as per Srl Item No 44 hereinbefore but 20mm bore complete all as specified and as directed.
S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and as directed. Note : Cutting chases as required shall be measured and paid seperately.
S & F 20 mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and as directed. Note : Cutting chases as required shall be measured and paid seperately.
S&F 75mm PVC (SWR) pipes single socketed in any length along with rubber ring joint laid in trenches with all accessories complete all as specified and as directed.
Dismantling water tanks of capacity exceeding 250 and not exceeding 500 ltrs complete all as specified and as directed.
S & F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres complete all as specified and as directed.
M&L for ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore dia iron pipe supplied and fixed in repairs complete all as specified and as directed.
S&F in repairs 15mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed.
S&F in repairs 20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors/walls, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description including cast-in-situ terrazzo (below or above ground level), not exc. 15 cm thickness, including removal of rubbish outside MoD land, complete all as specified and as directed.
M&L for PCC (1:3:6) Type C-2 50 mm thick using 40 graded stone aggregate as in sub base of floor complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block coloured and polished of any shape and size confirmeing to IS-15658-2006 of 60 mm thick, M-35 grade over 25 mm thick sand cushioning, etc complete all as specified and as directed.
M&L for sand for sand cusion for interlocking tiles including spreading and levelling complete all as specified and as directed.
M&L for PCC 1:2:4 Type B-1 (using 20mm stone crushed agg.) as in rounded or chamfered on edges in any description complete all as specified and as directed.
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and as directed.
M&L for Brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and as directed.
Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and as directed.
M&L for concealed point wiring for the following the PVC insulated and sheathed cable 1.5 sq mm (nominal area) multistranded copper conductor 1100 v FRLS grade single core including PVC conduit medium grade of appropriate size (not less than 20 mm dia) ISI marked concealed in wall and surface on ceiling complete with all accessories and all as specified including 1.5 sq mm PVC insulated sheathed multistranded copper conductor to common earth and connected to earth dolly for following :- (Note: 1. The cutting chases shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. 2. Rate quoted by the contractor deemed to be included metal flush box (not less than 2.5 mm thick) of suitable size as required at site and 3 mm thick laminated sheet suitable for mounting of switch and socket etc .)
One light point control by one switch .
One ceiling fan/exhaust fan control by one switch .
One 3 pin socket outlet, 5 Amps independent .
One 3 pin 5 amps socket outlet on the same board with other switches .
All as per item No. 65 hereinbefore but wire 2.5 sq mm cable for switch socket outlet 3 pin 15 Amps with 1.5 sq mm as earth continuity conductor. (FOR 15 Amps socket point)
All as per item No. 65 hereinbefore but wire 4.0 sq mm cable for switch socket outlet 3 pin 15 Amps with 4.0 sq mm as earth continuity conductor. (FOR geyser/AC point)
S & F switch piano flush type one way 5 Amps complete all as specified and as directed.
S&F ceiling rose three terminal complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5 Amps complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and as directed.
S&F switch piano, flush type single pole 15 Amps complete all as specified and as directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED tube light fitting mirror type with high output diffuser 2 feet, 10 watts 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Taking down carefully exsiting ceiling fan of any size, sealing cable end, dismantling blades and removing fan and blades and kept aside for reuse complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type complete all as specified and as directed.
S & F MCCB 125 Amps capacity, 3 pole, 25 KA, 415 volts, complete with extended terminals to be fixed in TPN DB. complete all as specified and as directed.
S&F in repair TPN DB's 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and as directed.
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
S & F in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar complete all as specified and as directed.
S & F MCB SP 6-32 Amps, 10 KA, 'C' Series complete all as specified and as directed.
S & F MCB SPN 40 Amps, 10 KA, 'C' Series complete all as specified and as directed.
M&L for earthing to switch gear/MCB DB with mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of galvanised iron nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust mixed with common salt to a packed thickness of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10 mm dia MS round bar as handle, 20 mm bore GI pipe medium grade for watering and 15 mm dia GI pipe light grade for protection of earth lead up to 7.5 mtr with funnel, wire mesh etc with and including testing complete all as specified and as shown in electrical plate No 3 of MES sch Part I.
S&F Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed or any other indicated situation for loop earthing etc. As required 4 mm dia galvanised iron or steel wire complete all as specified and as directed.
S&F MS seamless steel tube 15 mm dia down rod for hanging the fan including cutting the false ceiling and making good the false ceiling after fixing of fan down rod complete all as specified and as directed.
S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 4 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit (conealed wiring) of suitable size complete all as specified and as directed. (FOR SPN DB's )
Supply and fixing wall fan 400 mm sweep, 240 Volts, AC, 3 speed, pull cord for speed and oscillaation, aluminium blades for high air thurst complete suitable clamps for wall mounting complete all as specified and directed. Make : Havells, Model No. GIRIK or its equivalent in Bajaj/Havells
S & F in repair sub main wiring for circuit of size 2.5 sq mm 2 core (FRLS) alongwith earth wire of 1.5 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit of suitable size complete all as specified and as directed.
S&F heavy duty single phase, steel body exhaust fan 300 mm sweep, 900 RPM complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener complete all as specified and as directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
akhil enterprises
Mohd Talha
JAIPAL AND BROTHERS
Ish Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .