Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC OLD AIRFIELD ROAD RAWALPORA WANBAL SRINAGAR 190005 J K | SRINAGAR | SRINAGAR | J K | 190005 | ₹8.7 Cr Quoted ₹8.8 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹13.8 Cr+₹5.0 Cr (57.4%)Rejected-Finance | ₹13.8 Cr+₹5.0 Cr (57.4%) | L2 | Rejected-Finance Being other than lowest bidder |
| 3 | L3₹16.9 Cr+₹8.2 Cr (93.2%)Rejected-Finance | ₹16.9 Cr+₹8.2 Cr (93.2%) | L3 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹8.8 Cr
EMD Value
₹7.7 L
Closing Date
24 Sept 2022, 6:00 pmClosed
CE AF Udhampur
CE AF Udhampur zone
CONSTRUCTION OF QTY-50 WATCH TOWER CUM GUARD REST ROOM WITH ALL ALLIED SERVICES AT AF STATION SRINAGAR
2022_MES_531403_1
CEAFU-19/2021-22
Open Tender
Civil Works
Lump-sum
540 days
Srinagar
As per NIT and tender document
8 documents required · 8 mandatory
₹3,000
GE (P) AF Srinagar
₹7.7 L
Yes
14 Nov 2022
16 Jun 2022
26 Sept 2022
16 Jun 2022
24 Sept 2022
10 Sept 2022
Amount
Total amount of Sch 'A' PART-I ( BUILDING WORK)
Total amount of Sch 'A' PART-II ( Section-I) ( INTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' PART-II ( Section-II) ( INTERNAL WATER SUPPLY WORK)
S&F C P health Faucets with flexible tube 15mm dia for EWC including all connection complete and all as specified and directed.
Total amount of Sch 'A' PART-III( Section-I) (INTERNAL ELECTRIFICATION WORK)
SCHEDULE `A' PART-III (Sec-II) (INTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S & F LED Lamp 20 W pin type including LED light driver etc complete all as specified and directed.
Supply and fixing Bracket for Security light fitting made of 40mm dia light grade GI pipe, 1.2 Mtr length bent to suitable shape for fixing of security light fitting with all necessary accessories Bracket, nuts, bolts, washers, two clamps made out of flat iron of size 50mmx5mmx600mm fabricated in shape and drilled holes for nuts and bolts all as specified and directed.
M & L for SMC/FRP Junction box, size 325 x 220 x 150 mm (inside dimension), 3 phase including four bar busbar of 100 Amp rating, cable glands, Busbar base, etc complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Total amount of Sch 'A' PART-IV ( Section-I) (EXTERNAL ELECTRIFICATION WORK)
SCHEDULE `A' PART-IV (Sec-II) (EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Dismantling existing 33 KV, HT pole-02 Nos and ACSR conductor, and shifting of pole to other location alongwith restretching/tightening the conductor assuming 03 conductor length per span approx 50 Mtr including earth and PCC work all as directed .
Supply, installation, testing & commisioning of LT feeder pillar box (KIOSK) outdoor type with provision of aluminium busbar three phase & neutral (TPN) with 4 strip each 160 Amps capacity and 60 cm long, duly colour coded, mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar conforming to IS 8623 Part (One), CPRI approved, totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 volts, 50 Hz, AC supply, outer shell shall be made out of 3.00 mm thick CRCA sheet & MS angle section of suitable size for frame, factory fabricated. Front & back door opening, protection of enclosure IP 56 as per IS-2147 of 1962 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door & covers including suitable size angle iron/flat iron frame work/support required with four legs 60 cm long using angle iron 40 x 40 x 6mm & locking arrangement at front with duplicate keys and making connection of incoming & outgoing cable using proper cable lugs, legs grouted in PCC 1:2:4, including MCCB 40 Amps 4 pole, 16 KA, Ics = 100% Icu, with fixed magnetic & adjustable thermal release, adjustable overload 80-100% & adjustable short ckt 5 to 10 In setting complete with phase separator - 02 Nos and platform for feeder pillar/LT panel shall be of suitable size as directed, 450mm height above ground level, the foundation shall be using PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregates), 15cm thick, brick work (with sub class B bricks) in CM 1:6, 15mm thick rendering in CM 1:6 on exposed surfaces & 100 mm thick PCC 1:3:6 type C1 using 20mm graded crushed stone aggregates as in padding on top & grouting legs of panel complete all as specified.
Fixing only and restretching/tightening the existing LT overhead conductors & GI earth wire mounted on insulators of any type on poles manually or by mechanical means to the extent of permissible sag and tension and binding with steel wires of appropriate size complete having upto 7 conductors per span of approx 35-40 mtr length and tightning of stay wire etc complete all as specified and directed. NOTE: Each span upto 7 conductors in parallel between pole to pole shall be measured as one unit only.
Re-routing of the existing underground laid XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100/11000 volts grade of any size and type laid at watch tower construction location excluding all necessary excavation, returning filling, removal of soil and laying brick and providing sand all as specified and directed.
Re-routing of the existing underground CI/DI/MS water pipe line laid at watch tower location of any type and size including all necessary excavation, levelling as per specified gradient including material and labour for required joints, returning filling, removal of soil and and providing soil all as specified and directed.
Re-routing of the existing underground GI water pipe line laid at watch tower location of any type and size including all necessary excavation, levelling as per specified gradient including material and labour for required joints, returning filling, removal of soil and and providing soil all as specified and directed.
Total amount of Sch 'A' PART-V (PLUMBING WORK)
Total amount of Sch 'A' PART-VI (ROAD/PATH/CULVERT WORK)
Total amount of Sch 'A' PART-VII(SEC-I)(SEWAGE DISPOSAL WORK)
Sch 'A' PART-VII (SEC-II) (SEWAGE DISPOSAL WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S & F of LLDPE tank for 05 user including vent shaft and other necessary fixing arrangement complete all as specified and directed.
S&F CI manhole covers 600 mm dia. complete all as specified and directed.
Total amount of Sch 'A' PART-VIII (PROTECTIVE WORK)
Total amount of Sch 'A' PART-IX (DEMOLITION WORK)
Total amount of Sch 'A' PART-X (SITE CLEARANCE AND EARTH WORK)
WANI INFRATECH PVT LTD
ALCO ENGINEERSPVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .