Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 266 1 S B GORAI ROAD BESIDE VIDYASAGAR MAIDAN ASANSOL 713301 | ASANSOL | BURDWAN | WEST BENGAL | 713301 | ₹4.7 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹4.8 L+₹7,087.33 (1.50%)Rejected-Finance 778 N LOWER CHELIDANGA ASANSOL PASCHIM BARDHAMAN | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | ₹4.8 L+₹7,087.33 (1.50%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹4.9 L+₹17,217.63 (3.63%)Rejected-Finance RAJBARI PARA JALPAIGURI | JALPAIGURI | JALPAIGURI | WEST BENGAL | ₹4.9 L+₹17,217.63 (3.63%) | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | M/S. SWAPAN BANERJEE L1 | M/s. SOMA ENTERPRISE L2 | MS S G Enterprise L3 |
|---|---|---|---|---|---|---|
| 1.00 | withdrawling the submersible pump motor set from river bed tube well after disconnecting of all the electrical and hydraulic connections as per direction of EIC | 4 | each | 2,300 ₹9,200 Lowest | 2,350 ₹9,400 | 2,450 ₹9,800 |
| 2.00 | Washing developing of tube well with air compressor pump and engine for 8 (eight) hours contineous pumping per dey with necessary arrangement for testing the yield in gallons as per hour with "V" notch including hire and lobour charges for all tools and plants and scafolding as required | 4 | /day | 7,520 ₹30,080 Lowest | 7,560 ₹30,240 | 7,620 ₹30,480 |
| 3.00 | Washing cleaning of the pump parts like stud nuts, coupling, shaft, impeller, bush, sleeve, rings sequentially then fitting fixing with supplying stud nuts, sleeve rings as per direction of EIC. | 2 | each | 740 ₹1,480 Lowest | 790 ₹1,580 | 810 ₹1,620 |
| 4.00 | Supply & delivery at site of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) a) Discharge-9 M3/Hour at head of 34 Mt (Head discharge may varies with out changing the motor HP rating considering the acceptence of the dept.) | 1 | each | 24,200 ₹24,200 Lowest | 24,400 ₹24,400 | 24,600 ₹24,600 |
| 5.00Supply & delivery of the following G.I/other materials for | ||||||
| 6.00 | 80 mm dia. Heavy type flange | 5 | each | 250 ₹1,250 Lowest | 260 ₹1,300 | 280 ₹1,400 |
| 7.00 | 80 mm dia. 90 degree bend, GI | 1 | each | 1,450 ₹1,450 Lowest | 1,650 ₹1,650 | 1,800 ₹1,800 |
| 8.00 | 80X150mm dia. GI Nipple | 1 | each | 215 ₹215 Lowest | 255 ₹255 | 290 ₹290 |
| 9.00 | 80 mm X 65 mm reducing socket | 1 | each | 250 ₹250 Lowest | 280 ₹280 | 300 ₹300 |
| 10.00 | 100 mm X 150 mm nipple | 1 | each | 200 ₹200 Lowest | 250 ₹250 | 290 ₹290 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
30 Jul 2025, 6:00 pmClosed
ASSISTANT ENGINEER
O/O Assistant Engineer,BMSD,PHE Dte.
Installation of 1 no new submersible pump (old riverbed tubewell) with allied works at Bhara w/s Scheme under BMD, PHE, Dte.
2025_PHED_878573_7
WBPHED/AE/BMSD/NIeT-4 OF 2025-2026
Open Tender
MECHANICAL
Item Rate
10 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
15 Sept 2026
18 Jul 2025
4 Aug 2025
18 Jul 2025
30 Jul 2025
18 Jul 2025
Amount
withdrawling the submersible pump motor set from river bed tube well after disconnecting of all the electrical and hydraulic connections as per direction of EIC
Washing developing of tube well with air compressor pump and engine for 8 (eight) hours contineous pumping per dey with necessary arrangement for testing the yield in gallons as per hour with "V" notch including hire and lobour charges for all tools and plants and scafolding as required
Washing cleaning of the pump parts like stud nuts, coupling, shaft, impeller, bush, sleeve, rings sequentially then fitting fixing with supplying stud nuts, sleeve rings as per direction of EIC.
Supply & delivery at site of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) a) Discharge-9 M3/Hour at head of 34 Mt (Head discharge may varies with out changing the motor HP rating considering the acceptence of the dept.)
Supply & delivery of the following G.I/other materials for
80 mm dia. Heavy type flange
80 mm dia. 90 degree bend, GI
80X150mm dia. GI Nipple
80 mm X 65 mm reducing socket
100 mm X 150 mm nipple
80 mm dia GI socket
200 mm ms flange 12 mm Slipon type
4 sq mm submersible flat cable as per IS-694 (Make- Approved)
Halide gasket
Supply, delivery and storage at site 80 mm dia M.S. E.R.W. column pipe, 4.85 mm thickness with both end threaded including one socket and threaded protector painted with anti corrosive paint a) 1.5 Mtr. Long
6 Sq. mm 3 core, 1.1 KV grade, Al. XLPEA cable conforming to IS : 7098 (Part – I) (Make-Approved)
For laying of cable by cutting sand at riverbed and laying through underground trenching and ramming the shifted soil as per direction of EIC.
Laying the above 10mm2 3 core PVC/ XLPE insulated aluminium Armored cable on existing water supply pipe collecting line made by our civil counter part with proper laying of cable and binding it with suitable size GI wire from T/W to the riverbed P/H complete as per IE rule as per direction of the EIC.
Supplying, fitting, fixing bolts with nuts, washer: 10 to 16 mm dia: Length up to 75 mm
Excavation of the sand / sany soil surrounding and top of existing connection line and depositing spoil with in the lead beyond 2 mtr including bailing out water manually and dressing bed after cable laying with pipe all complete as per direction of EIC. Depth of excavation upto 1.5 mtr.
Welding in M.S. structural work with gas or electric, Continuous weld.
Cutting to requisite length or shape departmental R.S. joists, channels, angles, tees, plates etc.
Installation of the pumping machinery with valves, pipe specials, short piece of item no-4, 5.8-5.10, including lowering of column pipe, making all electrical connection (including panel connection) and water line interconnection complete as per direction including supply of necessary materials as required for the work excluding cable laying and testing for a certain period.
Earthwork inexcavationof foundation trenches or drains, inall sorts of soil (includingmixed soil but excluding lateriteor sandstone) including removing, spreading or stacking the spoils within a lead of 75m. asdirected. The item includes necessary trimming the sidesof trenches, levelling,dressingandrammingthe bottom, bailing out water as required complete.
Earthwork infilling in foundation trenches or plinthwith good earth, in layers not exceeding 150mm. Including watering and rammingetc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.
Lowering of repaired submersible pump motor set from river bed tube well after disconnecting of all the electrical and hydraulic connections as per direction of EIC
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).
Add: 18% GST
Add: 1% Cess
M/s. SOMA ENTERPRISE (BID ID -6746149)
MS S G Enterprise (BID ID -6746174)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .