Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹10.4 L+₹1.0 L (10.8%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹11.1 L+₹1.8 L (18.7%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹12.9 L+₹3.6 L (38.3%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹15.9 L+₹6.5 L (69.9%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹19,200
Closing Date
24 Nov 2020, 6:00 pmClosed
AGE (I) (AF) Chimney Hills, Bangalore
Asst Garrison Engineer I AF Chimney Hills Chikkabanavara Post Bangalore, PIN- 560 090
SPECIAL REPAIRS TO BUILDINGS OF AGE YARD AT 2 AFSB MYSORE
2020_MES_388817_1
8415/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) Chimney Hills, Bangalore
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) (AF) Chimney Hills, Bangalore
₹19,200
Yes
26 Mar 2021
7 Nov 2020
26 Nov 2020
7 Nov 2020
24 Nov 2020
11 Nov 2020
7 Nov 2020 - 10 Nov 2020
Amount
Taking down chowkats or frame with shutter (without taking off shutter from frame) area not exceeding 1.5 sqm each all as specified and as directed.
Taking down chowkats or frame with shutter (without taking off shutter from frame) area not exceeding 1.5 sqm each as in steel windows and ventilators all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing coat) and including removing rubbish off the premises complete all as specified and as directed.
Taking down cement plaster of any description from wall/ceiling and roof slabs including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking up or down 20 mm bore mild steel galvanised tubing with all fittings and connections including cleaning for re-fixing or removal to store complete all as specified and as directed.
Dismantling water tanks, capacity exceeding 250 litres but not exceeding 500 litres and removing complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level complete all as specified and as directed.
Dismantling of 100 mm internal dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenche, if required all as specified and directed.
Material and Labour for hard core of broken stone or boulders of guage not exceeding 63mm deposited spread and levelled in layers not exceeding 15cm thick watered and rammed to true surface complete all as specified and as directed.
Material and Labour for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and as directed.
Material and Labour for forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, in cement mortar 1:4 complete all as specified and as directed.
Material and Labour for making good under cills or over arches, lintels and bressummers, including all pinning when necessary, in cement mortar 1:4 complete all as specified and as directed.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified and as per drawings and directed by Engr-in-Charge
Supply and fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, in the frame at site as per specification & drawing and as directed
Supply and fix butt hinges, 75mm size, medium weight, cold rolled mild steel all as specified and directed
Supply and fix 75 mm long aluminium anodised barrel tower bolts of extruded section and fixed, all as specified and directed
Supply and fix 75 mm long extruded aluminium alloy handles, cast type, anodised all as specified and directed
Supply and fix 150 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed
Supply and fix in repairs harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. all as specified and directed
Supply and fix in repairs brass chromium plated tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges including brackets complete all as specified and as directed.
Supply and fix aluminium anodised powder coated windows, frames with 3 channels for sliding glazed and mosquito proofing shutters & with necessary accessories like jointing cleats, rubber packing, beading and screws etc, including 4mm thick glass panes, stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm for mosquito proofing and powder coated aluminium grill of design DG-103 as per TD drg no AFB/TD/352/11 Sht 1/2 & 2/2 and AFB/TD/237/05 Sht 1/1, complete all as specified and directed.
Supply and fix aluminium anodised powder coated louver ventilators with necessary accessories like jointing cleats, rubber packing, beading and screws etc, including 4mm thick tinted glass cut to 10 cm wide strips as in louvers, stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm for mosquito proofing and powder coated aluminium grill of design DG-103 as per TD drg no AFB/TD/352/11 Sht 1/2 & 2/2 and AFB/TD/237/05 Sht 1/1, complete all as specified and directed.
Material and labour for rendering 15 mm thick in cement mortar 1:4 on concrete surfaces over roof slab mixed with water proofing liquid as per manufacturers instructions finished even and smooth without using extra cement complete all as specified and as directed. Note : Liquid water proofing compound shall be measured and paid separately as supply only item here in after
Supply only liquid water proofing compound all as specified and as directed.
Material and Labour for applying oil bound bituminuous primer @ 0.20 kg/Sqm and providing 4 mm thick APP modified water proofing membrane weighing not less than 4.0 Kg/sqm, reinforced with non polyester matt weighing not less than 160 gms/Sqm having softening point not less than 150 degree centigrade, having tensile strength of 650 N/5 cm and 350 N/5 cm in longitudinal and transverse directions respectively, reinforcement tearing strength of 180 N, laid over roof slab and bonded to the sub strata by heat process by flame torch application with and including minimum 10 cm side over lap and 15 cm end over lap, sealed/fused by flame torch application as per manufacturer's instructions, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg /sqm and finally applying solar reflective bituminous aluminium paint @ 0.10 kg/Sqm over the membrane complete all as specified and directed.
Material and Labour for 12 mm thick Perforated particle board/tiles 60x60 cm size, in ceiling for insulation and acoustic purposes, fixed with staples on 605 x 605mm size anodised aluminium snap grid frame work, suspended with ceilling cleats made out of Galvanised flat iron 40x3 mm size, 60mm long secured to 6mm dia adjusting level GI hangers (up to 1200mm length) fixed to roof slabs with expansion hold fasteners 12.5mm dia, 40mm long and applying one coat of oil bound distemper over a coat of primer including preparation of surfaces complete all as specified and directed.
Material and Labour for cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate), 75mm thick as in plinth protection, finishing cement concrete surface even and smooth without using extra cement, laid in panels including necessary form work and forming construction joints filled with seailing compound grade - A complete all as specified and directed.
Material and Labour for 75mm thick cement concrete 1:4:8, type D-2 (using 40mm graded aggregate) as in sub base to floors complete all as specified and directed.
Material and labour for 40mm thick, cement concrete 1:2:4, type B1, using 20 mm graded crushed stone aggregate, as in pavings, path floors finished even and fair and making impression whilst the concrete is green complete all as specified and directed.
Material and Labour for coloured non skid ceramic joint free tiles 7 to 8 mm thick (square/rectangular) area exceeding 0.06 Sqm but not exceeding 0.11 Sqm laid in floors etc., set, jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Material and Labour for coloured non skid ceramic joint free tiles 7 to 8 mm thick (square/rectangular) area exceeding 0.11 Sqm but not exceeding 0.18 Sqm laid in floors etc., set, jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Material and Labour for coloured non skid ceramic joint free tiles 7 to 8 mm thick (square/rectangular) area exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in skirtings etc., set, jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including a backing coat of rendering 10 mm thick in cement mortar 1:4 complete all as specified and directed.
Material and Labour for glazed ceramic tiles of size 300 x 200 x 7mm thick on vertical surfaces as in dado/skirting set, jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including a backing coat of rendering 10mm thick in cement mortar 1:4 complete all as specified and as directed.
Supply and fix 15 mm bore mild steel galvanised tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors including cutting chases for concealed water tubing etc., and making good to facing where required and pointing in cement mortar 1:3, cutting not exceeding 10 cm in girth and including taking up or down old steel tubing and connections complete all as specified and as directed.
Supply and fix 20 mm bore mild steel galvanised tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Fixing only 20 mm bore old steel tubing and connections (old steel tubings obtained from taking up/down shall be reused) in new or old position including fittings (Walls, ceiling, floors, etc.,) complete all as specified and as directed.
Supply and fix in repairs bib taps cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down for iron pipes or for brass ferrule, bore dia of pipe 15 mm complete all as specified and directed.
Supply and fix in repairs stop valves fancy type, cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union, bore dia of pipe 15mm complete all as specified and directed.
Supply and fixing in repairs vitreous china wash down water closet pedestal pattern white with 'P' or 'S' trap and plastic water closet seat cover including fixing bolts etc complete all as specified and as directed.
Supply and fix in repairs 10 litres capacity PVC valveless, syphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and PVC connection 15mm size with PTMT nuts of length 600mm and 15 mm angle stop valve of PTMT (Minimum weight 15mm-90gms) any colour, high pressure screwed for iron pipe complete all as specified and directed.
Supply and fix 500 Ltr capacity rotational moulded polythene water storage tank (Cylinderical vertical with closed top) hoisted and fixed in position and connecting the inlet and out let pipe etc complete all as specified and directed.
Supply and fix in repairs 25 mm ball brass valves. high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed.
Supply and fix in repairs PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed.
Supply and fix in repairs 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in floors complete all as specified and directed
Supply and fix in repairs 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed
Supply and fix in repairs PVC (SWR) bends, 110mm bore, any radius all as specified and directed.
Supply and fix PVC (SWR) 110mm bore, junction single (single T) Equal or unequal complete all as specified and directed.
Supply and fix PVC (SWR) couplers 110/110 mm bore complete all as specified and directed.
Supply and fix PVC (SWR) vent cowl 110 mm bore complete all as specified and directed.
Supply and fix PVC (SWR) 'P' trap 110/110 mm bore complete all as specified and directed.
Material and labour for complete removal of existing treatment including preparation of old decorated surfaces of walls and applying two coats of white wash over chalk whiting all as specified and directed.
Material and labour for complete removal of existing treatment including preparation of old decorated surfaces of ceilings and applying two coats of white wash over chalk whiting all as specified and directed.
Material and Labour for preparation of old decorated surfaces of walls by washing, rubbing, brooming down or steel wire brushing or scraping down smoke soot, moulds, mass and efflorescent slats, and applying one coat of colour wash complete all as specified and directed.
Material and labour for complete removal of existing treatment including preparation of old decorated surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
Material and labour for complete removal of existing treatment including preparation of old decorated surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
Material and labour for preparation of old painted wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
Material and Labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Taking down carefully existing copper /aluminium point wiring (Light, fan, socket or power) complete including fittings and fixtures such as switches ceiling roses socket, regulator etc. and making good disturbed surfaces of walls, floors etc to match with the existing surface/ finishes complete all as specified and directed.
Material and Labour for Point wiring with 1.5 sqmm single core FRLS, PVC insulated and unsheathed cable 1100 volts grade, confirming to IS-694 and marked, with multistranded copper conductor drawn through and including suitable size rigid PVC conduit along with fittings and all accessories, cutting chases and making good to walls, floors etc, including 1.5 sqmm, single core FRLS, PVC insulated unsheathed 1100 volts grade, copper cable green colour as earth continuity conductor and connected to common earth dolly, fabricated/pressed steel terminal box made out of 1.60mm thick modular bottom sunken type, suitable modular top cover with frame, number of modules as required complete all as specified and as directed for one light/fan/bell point controlled by one one way switch.
All as per item No. 59 here-in-before but for 3 pin, 5 Amps socket outlet controlled by one, one way switch on independent board.
All as per item No. 59 here-in-before but for 3 pin, 5 Amps socket outlet controlled by one, one way switch on same board.
All as per item No.59 here-in-before but for 3 pin 15 Amps switch socket outlet on independent board with 2.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade copper cable and provision of 2.5 sqmm FRLS PVC insulated unsheathed cable 1100 volts grade stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting up to fittings complete.
Supply and fixing modular switch one way, 6 Amps, 1 module 230 Volts complete all as specified and as directed
Supply and fixing modular switch one way, 16 Amps, 1 module 230 Volts complete all as specified and as directed
Supply and fixing modular bell push, 6 Amps, 1 module 230 Volts complete all as specified and as directed
Supply and fixing modular socket, 6 Amps, 2/3 pin combined, 2 module, 230 Volts complete all as specified and as directed
Supply and fixing modular socket, 6/16 Amps, 2/3 pin combined, 2 module, 230 Volts complete all as specified and as directed
Supply and fix ceiling rose, surface type PVC/ Polycarbonate, isolated body, three terminal, ISI marked complete all as specified and as directed.
Supply and fixing modular type fan regulator electronic step type 250 Volts single phase 2 module,120 watts connecting suitable for ceiling fan 1200 /1400 mm sweep complete.
Material and Labour for taking down ceiling/wall mounted/exhaust fan any type, make and size, after disconnecting cable ends for carrying out repairs in buildings, refixing the same with suitable fasteners after completion of repairs including minor servicing i.e. cleaning, greasing, oiling etc.. and applying one coat of synthetic enamel paint by spraying, colour as approved, refixing the same, connecting including providing flexible copper conductor cable 23/.0076 from ceiling rose/connector to fans complete all as specified directed.
Supply and fix in repairs energy efficient LED batten tube light fitting T8 1 X 22 watt LED tube including crystal glass LED tube light with integrated electronic driver (double side connection) of 20 watt, 4ft in length, nano diffuser technology and connecting with twin core flexible copper cable from fitting to ceiling rose all as specified and as directed. Make: Havells Model No REGALBATTENT8UPTO1X22WSSBSWH for batten and CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent in Crompton/Philips/Bajaj
Supply and fix in repairs energy efficient surface and wall mounted LED batten with aluminium housing & integrated electronic driver of 10 watt , 2 ft length Land connecting with twin core flexible copper cable from fitting to ceiling rose all as specified and as directed. Make: Havells Model No LUMILINEPLUSBS10WLED865SPCSS or equivalent in Crompton & Philips
Supply and fix surface mounting LED flat panel, 34 W, 2' X 2' size, aesthetically designed and glare free symmetrical illumination, suitable for grid ceiling all as specified and directed. Make: Havells Model No. PLUTOSURFACE2X2PLS34WLED840S or equivalent in Phillips/Bajaj
Supply and fix in repairs bldg security light 35 W, LED, IP 65 including 40 mm dia medium grade GI pipe bracket 1.2 mtr long bend to shape fixed on wall/beam/poles with suitable size MS clamps, bolts, nuts, washers, etc suitable size complete all as specified. Make: Havells Model No ENDURACITYLITEPLUSSL35WLED757SASYBOPC or equivalent in Philips or Bajaj
Supply and fix lamp holder, PVC/polycarbonate with back plate suitable for batten fittings with LED bulb 7 watt complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure vertical loadline distribution board TP&N, 06 ways, 415 volts, double door, with 250 amps rated bus bar, neutral link, blanking plate with IP 43 protection and suitable for mounting MCCB as incomer and MCB as outgoing including taking down old old unserviceable DBs complete all as specified and as directed.
Supply and fix in repairs sheet metal enclosure distribution board SPN, 12 ways, 415 volts, double door, with 200 amps rated bus bar, neutral link, blanking plate with IP 43 protection and suitable for MCBs including taking down old unserviceable DBs complete all as specified and as directed.
Supply and fix in repairs sheet metal enclosure distribution board SPN, 04 ways, 415 volts, double door, with 200 amps rated bus bar, neutral link, blanking plate with IP 43 protection and suitable for MCBs including taking down old unserviceable DBs complete all as specified and as directed.
Supply and fix in repairs MCB single pole, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity, confirm to IS/IEC 60898-1, C' series complete all as specified and as directed.
Supply and fix in repairs MCB single pole, 240 volts, 40 Amps, 10 KA rupturing capacity, confirm to IS/IEC 60898-1, C' series complete all as specified and as directed.
Supply and fix in repairs MCB SPN, 240 volts, 32 Amps, 10 KA rupturing capacity, confirm to IS/IEC 60898-1, C' series complete all as specified and as directed.
Supply and fix in repairs MCCB 03 Pole, 415 Volts, 50 Hz, 125 Amps, fixed type, breaking capacity 16 KA repturing capacity including spreader links on both sides complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified. Note : A deduction of 10% shall be made from total computed volume of filling to cater for bulkage irrespective of machinery used for ramming.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed.
Supply, laying, jointing, testing and commissiong LT under ground, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cables with stranded aluminium conductor 1100 volts grade confirming to IS, laid in trenches, ducts, passing through pipes or fixed to wall with suitable clamps/saddles etc., including cable glands, terminal socket and connecting of size 2 Core x 10 Sqmm complete including taking out/down damaged/unserviceable LT UG XLPE cable of size 10 sqmm, 2 core from trenches/ drawn through pipes etc., after necessary electical disconnection all as specified and as directed.
Supply and laying common burnt clay, building bricks, sub class 'B' designation 75 and laid in trenches for cable protection as specified and directed.
Labour only for riddled earth done through by riddling of excavated soil and spreading the same in layers, overall thickness 23 cm, below and upper part of the LT UG cable for cable cushioning all as per clause 19.75 of SSR part -I complete all as specified and directed
Supply and laying galvanised steel pipe 40mm bore dia light grade including all fittings complete laid in trenches or in floor, for road crossing/fixed on wall/on pole for protection of LT UG cables all as specified and as directed
Material and Labour for replacement of earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm, 6mm thick, buried directly in ground vertically at a depth not less than 2.25 metres deep below normal ground level with top edge of the earth plate not less than 1.5 metres below normal ground level and filling with mixture of common salt and charcoal surrounded all sides 15cm thick (minimum)and connecting electrode with galvanised iron wire of 4 mm dia by means of bolts, nuts, check nuts and washers made up of galvanised iron or steel and protected by light grade 15mm dia galvanised iron pipe connected to main switch board or main control board and watering arrangement with 20 mm bore GI medium grade pipe, GI funnel with wire mesh, including PCC 1:3:6 type C-1 pit with cover made of RCC 1:2:4 type B-1, reinforced with welded steel wire fabric not less than 4 kg per sqm with handle and angle iron frame, including necessary excavation and earth work, returning filling and disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in electrical plate No. 3 of MES schedule part-1 connected to test point terminal all as specified including taking down old earthing & testing new earthing on completion all as directed.
Sri Lakshmi Venkateswara Enterprises
H S S ENGINEERS AND CONTRACTORS
Suneetha Engineers and Contractors
SREE VARU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .