Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC PLOT NO 39 SHRI SHIVE NAGAR 05 MOTI BANDHA MACHEDA HARMADA JAIPUR 302013 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹37.7 L+₹86,756 (2.35%)Rejected-Finance H NO 209 D SHRI SHIVA NAGAR IV MANCHARA SIKAR ROAD JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹41.2 L+₹4.3 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹77,220
Closing Date
23 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jaipur
GE Jaipur
ADDN/ALTN OF SHELTER No 9006/1-4/2006 AND 9006/CH/DH/2006 IN NALA GARDEN COMPLEX UNDER ZONE-II AREA AT JAIPUR MIL STN
2024_MES_681455_1
GE/J- /2024-25
Open Tender
Civil Works
Item Rate
180 days
GE Jaipur
As per Tender Docuements
5 documents required · 5 mandatory
₹500
GE Jaipur
₹77,220
Yes
18 Jan 2025
26 Oct 2024
25 Nov 2024
26 Oct 2024
23 Nov 2024
9 Nov 2024
Amount
Dismantling of plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof covering complete all as specified and directed.
M&L pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L prepainted galvatume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strenght of 550 Mpa as in ridge / roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises complete all as specified and directed.
M & L for light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles n exc. 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the floor laid over and incl 15mm thick screed in cement mortar 1:6 complete all as specified and directed.
M & L for light shade vitrified ceramic tiles 10mm thick (square / rectangular) polished, area of each tiles n exc. 0.36 sqm in vertical surface such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering in CM 1:4 complete all as specified & directed.
M&L 2mm thick fibre glass reinforced translucent plain sheeting with side laps fixed with coach screw, wire steple or drilling in wall, RCC post etc and washer in roof, wall etc completeall as specified and directed
M&L complete removal of existing treatment of old plastered surfaces of wall and applying two coats of distemper oil emulsion of approved tint complete all as specified and directed.
Taking down shutters of any description of area exc 1 sqm but n exc 2 sqm each complete all as specified and directed.
S & F 35mm thick second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
S&F 35mm thick Plain framed panelled shutters 2nd class hardwood (any numbers of panel) with panel of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial faces veneers,and fixed to chowhat complete all as specified and directed.
S & F 100 mm butt hinges medium weight cold rolled mild steel and fixed complete all as specified and as directed.
S&F 150mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F 150mm long aluminium handles, cast type anodised complete all as specified and as directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor; overall length of cover plate 150mm complete all as specified and directed.
S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete as directed and specified.
M&L for preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (Ist quality) over a coat of pink primer complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire steple complete all as specified and as directed.
Dismantling false ceiling board or insulation board etc, any thickness including snap grid frame etc complete all as specified and as directed.
Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with Dune Tegular 24 Edge Tiles of 16mm thickness and Prelude 24mm face exposed grid. The tiles shall have sand texture visual with acoustical punchers, Humidity Resistance (RH) of 99%, NRC 0.5 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84 with Board edge in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of up to 41%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on Prelude 38 with 24 mm wide T - section flanges colour global white (matching to tile colour) having roll formed double stroke rotary stitching on all T sections i.e., the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 15 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 18kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull-out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications above) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall.Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per recommended procedure. SUSPENSION SYSTEM accessories supplied by consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).
S&F 12mm thick Ply wood, grade BWR type BB 12 mm thick fixed with screw to timber frame work complete all as specified and directed.
M&L Preparing old painted steel surfaces of any description, not otherwise descri-bed, over 10 cm in width or girth and applying two coat of synthetic enamel paint (Ist quality) of approved tint complete all as specified.
M&L for preparation of old painted wooden surface of any description, not otherwise descri-bed, over 10cm in width or girth and applying one coat of synthetic enamel paint (Ist quality) of approved tint complete all as specified & as directed.
M&L preparation of new steel surface of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint (Ist quality) over a coat of red oxide primer complete all as specified and as directed.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates conforming to Fe410-W(Gde E-250) Quilaty A complete all as specified and directed.
S&F for solid PVC Wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixed at site on PVC frame as per specification and drawing complete all as specified and directed.
S&F 5 mm thick PVC Sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
S&F factory made steel window with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars devetailed or welded incl inserting the holdfast in stone / brick masonay and make good the distrubed portion complete all as specified and as directed.
S & F factory made steel window with side hung shutters including box type hinges with steel handle and steel peg stay complete without glazing bars devetailed or welded incl inserting the holdfast in stone/brick masonay and make good the distrubed portion all as specified and as directed.
M & L for sheet glass 3mm thick ordinary quality and glazing with oil putty in square not exc.0.5sqm in each pane complete all as specified and directed.
E/M portion Taking down carefully surface aluminum /copper point wiring, casing capping /PVC concealed conduit for (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concelled rigid non matalic PVC conduit medium grade not less then 20mm dia ISI marked with all conduit fittings/fixing accessories with modular metal flush box of thickness not less then 1.0mm thick covered with modular white sheet cover plate and frame for mounting, switches, sockets, fan regulators for one light point controlled by one switch incl making good the disturbed portion complete all as specified and directed.
,---ditto--- all as per item No. 32 above but one fan point controlled by one switch complete all as specified and directed.
,---ditto--- all as per item No. 32 above but for socket outlet 6 Amps controlled by one switch on the same board with other swithces complete all as specified and directed.
,---ditto--- all as per item No. 32 above but socket outlet 6 Amps controlled by one switch on independent board complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) drawn into and including concelled rigid non matalic PVC conduit medium grade not less then 20mm dia ISI marked with all conduit fittings/fixing accessories with modular metal flush box of thickness not less then 1.0mm thick incl covered with modular white sheet cover plate and frame for mounting, switches, sockets, fan regulators for one 3 pin, 16 Amps socket outlet point controlled by one swith on independent board incl making good the disturbed portion complete all as specified and directed.
S&F angle holder, insulated polycarbonate body with back plate complete all as specified and directed.
S&F switch modular 1 way 6 Amps, 230 volts, 1 module complete all as specified and directed.
S&F modular switch 1 way 16 Amps, 230 volts, 1 module complete all as specified and directed.
S&F modular socket, 2-in-1, 6/16 Amps, 2/3pin combined 2 module AC 230 volts complete all as specified and directed.
S&F modular socket 6 Amps, 2-in-1, 2/3 pin combined 2 module AC 230 volts complete all as specified and directed.
S&F modular fan regulator 100 watts, 120-280 volts 2-module, step type complete all as specified and directed.
S&F ceiling rose 3 plates polycarbonate body complete all as specified and directed.
Taking down MCB distribution board with incoming and outgoing controls any make and capacity after disconnecting complete all as specified and directed.
S&F MCBs Distribution board tripple pole and neutral (VTPN) 4 ways, powder coated, CRCA steel sheet, suitable for MCCB incomer upto 160amp, degree of protection IP-43, IK09 with reversible double door, 415V, recess mounted having insulated 200 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. Note : MCCB, MCBs and MCB DB shall be of the same make.
S&F MCBs Distribution board SPN, 8 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 415V, recess mounted having insulated 100 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F MCBs of 'B' curve single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
,---ditto-- all as per item No. 47 above but MCB SPN 32 amps complete all as specified and directed.
,---ditto-- all as per item No. 47 above but MCB tripple pole 40 to 63 amps complete all as specified and directed.
S&F MCCB TPN, 100amp, 415 volt, adjustable type, with breaking capacity 16KA, thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB including reqd cable connections with copper lugs of suitable size and testing & commisioning complete all as specified and directed.
S&F LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. Make - Philips Cat part BN308C LED20S-6500 L120 PSU WH, Crompton Cat part CIS-305-40-57-SL-DP-NWH, Havells Cat no STOUTPLUS600BS20WLED840SPCWH.
S&F LED batten (0.6m) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 900 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 50000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed.
Supply and fixing energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with full glow fully diffused diffuser and lumen output of 3600 lumens having constant current electronic driver of 36 watt duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required complete all as specified & directed.
S&F LED bulk head light fitting 9 /10 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate body with LED driver duly prewired connection with 0.75sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified & directed.
S&F greenline high efficiency LED light luminaire 35 watt complete with driver, pressure die cast aluminium housing, UV stablized polycarbonates cover, inbuilt power unit, IP-65 protection including mounting bracket made of 25mm GI pipe, medium grade ISI marked not less than 1.2m, bend in shape, fix with 02 no clamps, nut, bolt and washers as reqd and painting the bracket with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for taking out ceiling fan 1200mm sweep 50Hz AC 230 volts and refixing at new location including minor repair and replacement of fan blade, down rod, nut, bolt and washer or spray painting in existing colour including 0.5sqmm thre core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling as required and writing MES No. on fan body complete all as specified and directed.
S&F ceiling fan 1200mm sweep 50 Hz AC 230 votls, 5 star rated in white colour with BLDC fan motor, Min air delivery 210 CFM with service value 6.00 BEE, blade set, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as required complete all as specified and directed. Note: Old ceiling fan shall be returned to MES store
S & F in repair 20amp, single pole and neutral socket outlet, with 2 pole and earth, metal enclosed plug top in powder coated CRCA steel sheet enclosure recess mounted with chained matel cover for socket out let with and incl one single pole B curve MCB 20 Amps complete all as specified and directed.
S&F exhaust fan, high speed, steel body 300mm sweep, 1400 RPM, four blade, heavy duty motor, copper wound double ball bearings, grey colour with louver, nuts, bolts and washers fixed in wall incl making suitable size of hole in brick/stone wall and making good the disturbed portion as per existing incl three core 0.75sqmm copper cable connection with protective steel bird guard complete all as specified & directed.
S&F exhaust fan, high speed, steel body 380mm sweep, 1400 RPM, four blade, heavy duty motor, copper wound double ball bearings, grey colour with louver, nuts, bolts and washers fixed in wall incl making suitable size of hole in brick/stone wall and making good the disturbed portion as per existing incl three core 0.75sqmm copper cable connection with protective steel bird guard complete all as specified & directed.
Supply, fixing and install of wind powerless industrial roof air ventilation fan stainless steel made out of wind turbine body 600mm sweep, 24" wind flow fins, high temperature resistant double ball bearing fixed on roof top as IS standard with fixing arrangement on RCC / CGI plateform with prevention of rain, dust, insects, noise etc complete all as specified and directed
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) making PCC pit of size 0.3m X 0.3m X 0.3m (inner size) in mix 1:3:6 type C1, 40 mm thick cover reinforced with 6 mm dia M.S bars, 3 nos both ways with lifting hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, including necessary excavation and earth work and testing on completion to achieve value not more than 2.0 ohm complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.5mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected with galvanised earth strip 32 x 6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI wire upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete. (Note - GI strip size 32x6 mm upto 7.5 m included in the item).
Dismantling and taking out UG cable any size and fixed in any position and removal from site complete all as specified and directed.
Supply, laying, jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on poles of size 35 Sqmm 3.5 core including all necessary clamps, nut, bolt washers complete all as specfied and directed .
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc. or for laying of cables n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as directed.
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as directed.
M & L Sand cushioning to under ground cable with screened and washed sand (non cohessive), 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge. Note : Punned thickness shall be considered for payment purpose.
M & L bricks for protection cover to UG cable (using old size sub class B bricks) with width equal to length of brick, laid dry and flat abutting each other with gaps between adjecent bricks not exceeding 10mm complete all as specified and directed.
S & F 50 mm bore GI tubing light grade with all fittings, fixed to wall/ pole / laid in road crossing etc as reqd for protection of cable complete all as specified and directed. Note : Cost of MS clamp, nut bolt, washer and GI fittings etc shall be inclusive in the quoted rates.
Supply, installation, testing and commissioning of LT feeder pillar panel board outdoor, fabricated out of min 3mm thick CRCA sheet suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system fabricate in compartmentalized design totally enclosed, dust, weather & vermin proof duly painted and consisting with TPN copper bus bars (R,Y & B) of rting 1.5 tims that controllling MCCB supported on 'F' class SMC insulators with 4 outgoing and one MCCB TPN incoming fixed in PCC 1:3:6 (using 20 mm graded stone aggregate) including danger plate etc including taking down old complete all as directed not less than (750mm x 650mm x 250mm) and leg height upto 45mm installed on procelain insulator with bus bar chamber protection class IP 42 class font opening & compartmental type with approach for cable entry an for easy maintenance duly internally wired with FRLS, PVC insulated stranded copper conductor cable of 1.0 sqm including Degital Amps Meter, Volt meter with LED indicators for R, Y & B and comprising of the following :- Incoming : One MCCB 160 Amps 4 pole 36 KA 415 Volts, 70-100%, 50 Hz Outgoing : (a) MCCB 100 Amps 25 KA AC 415 Volts - 03 Nos (b) One MCCB TPN, 63 Amps 16 KA , AC 415 Volts.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Satish kumar and company (BID ID -3167067)
M/s KAKSI ENTERPRISES (BID ID -3167353)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .