Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹44.7 L+₹56,163.39 (1.27%)Rejected-Finance NOT AVAILABLE | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹45.2 L+₹1.1 L (2.49%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹45.7 L+₹1.6 L (3.66%)Rejected-Finance ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹45.8 L+₹1.7 L (3.87%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹87,200
Closing Date
3 Aug 2022, 6:00 pmClosed
GE (AF) JORHAT
GE (AF) JORHAT PIN-785005
PROVN OF SHEDS ON EXISTING PLINTH AT AFS UNDER GE (AF) JORHAT.
2022_MES_538121_1
8975/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) JORHAT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹87,200
Yes
17 Oct 2022
14 Jul 2022
5 Aug 2022
14 Jul 2022
3 Aug 2022
27 Jul 2022
Amount
Demolition of cement Concrete (unreinforced) above ground floors and pavings exc 15 cm thickness and removing debris from site of work to out side MOD land complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out as in soft / Loose soil, complete all as specified and directed.
M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Removing excavated material (soil) to a distance exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm. complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D2(using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete flat complete all as specified and directed.
M&L for Reinforced cement concrete,M-25 (Design mix) as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Use and waste of formwork to sides of columns, pillars etc. for fair finished surfaces of concrete complete all as specified and directed.
M&L for Reinforced cement concrete, M-25 (Design mix) as in columns, pillars, piers, posts and struts complete all as specified and directed.
S&F Mild steel TMT bars 08 to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F MS Steel work as in tubular trusses, posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed.
S&F Mild steel bolts 20 mm dia of neck, purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed.
S&F Pre- painted Galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as per specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after preparation of new steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described. complete all as specified and directed.
M & L for point wiring with 1.5 sqmm FRLS grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC casing and capping (not less than 20 mm wide) complete with all acessories including PVC board/ box of suitable size for mounting of switches, sockets, regulators etc including 1.5 sq mm stranded copper conductor cable FRLS grade PVC insulated and unsheathed as earth continuity conductor for one Fan / light point controlled by one way switch complete by maintaining the colour code complete all as specified and directed.
-Ditto- all as per Ser item No 17 here-in-before but with 2.5 sqmm cable for 15 amps socket outlet on independent board, using 2.5 sqmm earth continuity conductor complete all as specified and directed.
S&F 100 watt highway, light luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete all as specified and directed. Make : Crompton Cat No. LHB11-100-CDL/60-M or its equivalent of make Philips / GE as approved by GE
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and directed.
S&F Ceiling rose surface backelite three terminals, PVC / polycarbonate insulated body complete all as specified and directed.
S&F Switch piano flush type, 6 Amps 240 volts single pole one way complete all as specified and directed.
S&F SP&N DBs, double door, 240 volt, 8 way for incorporating MCBs SP with 200 Amps rated busbar complete all as specified and directed. MAKE:- Legrand Cat part No. 5076 11 or equivalent of make L&T/ Siemens as approved by GE.
S&F MCB SP&N, 240 volts, 32 Amps, 10 KA, C Curve including connection, testing and commissioning complete all as specified and directed.
S&F MCB single pole, 240 volts, 5 - 32 Amps, 10 KA, B Curve including connection, testing and commissioning complete all as specified and directed.
M&L for Earthing with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to GI wire 4 mm dia as earthing lead by means of nut, bolts and washers made out of galvanised iron mild steel and 32 mm dia GI pipe "light grade" for protection of earth lead and connected to test point or as directed including PCC Pit in Cement Concrete Type C2 1:3:6 (using 20mm graded stone aggregate) and RCC Cover of size 450X450X50mm in RCC type B1 1:2:4 (20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, including necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Soil upto a distance of 50.00 mtr and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and testing on completion, complete all as specified and directed.
S & F 300mm long and 12 mm dia Air termination, single pointed, copper rod including necessary fixing arrangement complete all as specified and directed.
S&F Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors of fixed to pole or any other indicated situation for loop earthing etc as required including making test point and testing complete all as specified and directed.
S&F 40 mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw with suitable enclosure made out of 2mm thick CRCA sheet complete all as specified and directed.
M&L for Earthing complete with copper plate electrode 30cm x 30cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to copper strip 20x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified and directed complete with excavation & earth work, PCC pit in cement concrete type C2 1:3:6 (Using 20mm graded stone aggregate) and 50mm thick RCC cover of size 450X450X50mm in RCC type B1 1:2:4 (Using 20mm graded stone aggregate) reinforced with and including 8.0 mm dia TMT bar @100mm centre to centre both ways, having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) forprotection of earth lead conductor all as directed and testing on completion complete all as specified and directed.
S&F 40mm dia galvanised iron pipe (medium grade) with all fittings laid in trench, floors or fixed to wall for mechanical protection of earth strips etc.complete all as specified and directed.
M & L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 4 core, complete all as specified and directed.
M & L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 16 sqmm 2 core, complete all as specified and directed.
Excavation in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, and getting out in Soft / Loose Soil, complete all as specified and directed.
Removing excavated materials not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the starting point, complete all as specified and directed.
M&L for Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. (NOTE : For the purpose of payment, punning thickness of Sand cushioning shall only be measured and paid).
S&F Sub-Class 'B' brick, well burnt, laid breadth-wise along the length of Cable as in Trenches over Sand Cushion for UG Cable protection, complete all as specified and directed.
S&F LT Panel cubical outdoor, cabinet type, platform mounted factory made CPRI approved totally enclosed dust and vermin proof openable from front side only and made out of 14 SWG (3.15mm) thick CRCA MS Sheet of overall size 750 mm (height) x 750 mm(width) x 450 mm (depth) and built on suitable size angle iron frame work , having front hinged door,GI earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and powder coated paint (Nickel Grey) The panel should be suitable for 415 volts , 50Hz, 3 phase 4 wire system and protection level not less IP-20 and internal connection should be provided with aluminium strips of suitable size including necessary foundation work and comprising following:-
1.BUS BAR CHAMBER: - M S Sheet bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 200 Amps- 4 Nos supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification 2. INCOMMER :- MCCB of capacity 63 amps 415 volts, 50 Hz 4 pole breaking capacity of 16 KA - 1 Nos.
4.OUTGOING FEEDERS:- (a) MCCB of capacity 40 amps 415 volts, 50 Hz 4 pole with breaking capacity of 16 KA - 2 Nos. (b) SPN MCB of capacity 32 amps of breaking capacity 10 KA for building load.
S&F Galvanised Iron Pipe 50mm Bore ‘Light grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.
M/S KESHAVECONSTRUCTIONS
KAY CEE CO. INDIA
M/S DHAR AND DHAR
M/S BARUAH ELECTRICALS
S.N.Lahoty
A.PONGSHI PHOM
M/S FRONTIER CONSORTIUM
THE SUPPLY AGENCY
M/S Praduman Kumar Sharma
Bidder Name
KAY CEE CO. INDIA
S.N.Lahoty
satyabhama and co
M/S KESHAVECONSTRUCTIONS
THE SUPPLY AGENCY
M/S Praduman Kumar Sharma
M/S DHAR AND DHAR
A.PONGSHI PHOM
M/S FRONTIER CONSORTIUM
M/S BARUAH ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .