12 Apr 2023, 5:00 pmClosed
SE RNB DIV1 BHUBANESWAR
SE RNB DIV1 BHUBANESWAR
SELECTION OF AGENCY FOR SUPPLY, PROCUREMENT AND EXECUTION OF INTERIOR WORKS (Pre-History Gallery, State Museum Part 01) AT ODISHA STATE MUSEUM BHUBANESWAR, ODISHA , INDIA
2023_EICCL_87549_1
ETCN-01 of 2023-24 3
Open Tender
Civil Works - Others
Item Rate
120 days
BHUBANESWAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹75,901
6 Jul 2023
5 Apr 2023
13 Apr 2023
5 Apr 2023
12 Apr 2023
5 Apr 2023
Amount
Civil work
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
With cement mortar 1:4 (1cement: 4 coarse sand)
Providing round the clock security guard with gun for watch & ward of Government premises and its all belongings by deploying neatly dressed security guards in 8 hour's shift including necessary T&P like torch, lathi and uniform etc.complete, as per the direction of Engineer-in-charge.(One job means 8 hour's duty).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Of area beyond 3 sq. metres
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles above 25 mm and up to 40 mm
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.
75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
New work (two or more coats)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Electrical
Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 6Amp ,250V Modular switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, Metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard/Great White/HPL)
Group-C L.P- 32 F.P- 4 C.B.P-
Supply and fixing of 6Amp plug point and 6A switch on modular metal box base and cover with all connections (make-Anchor/ Legrand /Roma/Great White/HPL)
Supply and fixing of 16Amp plug point and switch on modular metal box base and cover with all connections (make-Anchor/ Legrand /Roma/Great White/HPL)
S/F of Multipurpose board consisting 2nos. 6Amp plug and switch with all connections (Modular type)
S/F of Multipurpose board consisting 4nos. 6Amp plug and switch Modular on metal box and Modular cover with all connections
Recessed extra lead submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire -Finolex/ L&T/Havells/V-Guard /Great White/HPL) exceeding to Group-C points in 2 X 1.5sqmm +1 x 1.5sqmm
Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire -Finolex/L&T/Havells/V-Guard/Great White/Mescab/HPL/KEI)
2 X 2.5sq.mm +1 X 1.5sqmm
2 X 4sq.mm +1 X 1.5sqmm.
Supply and fixing of following different DD DB BOX .(Make-Legrand/ Hager/ Simens/ schneider)
16way Double door DB BOX.
8way Double door DB BOX.
Supply and fixing of 6Amp to 32A rating 240 V/415 V "C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make-Legrand/ Hager/ Simens/ schneider) (Acti 9)
6 to 32 SP MCB
63 A DP MCB
Supply of following Copper armoured XLPE cables insulated ISI marked.(Make- HAvells/ Polycab/ KEI / RR)
2cx1.5sqmm
3cx2.5sqmm
4cx4sqmm
4cx6sqmm
4cx10sqmm
4cx16sqmm
Cable laying
Laying of cable in ground with protective covering
Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required.
Laying of cable on surface
Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade of size not exceeding 25 sq.mm on surface as required.
Different of medium G.I. Pipe (Make - Tata/ Jindal/ (Per mtr)
25 mm G.I. Pipe (3/4")
32 mm G.I. Pipe (1")
40 mm G.I. Pipe (1 1/2")
50 mm G.I. Pipe (2")
Supply & Fixing of LED round / square Surface light fitting (Make-Bajaj/Philips /Crompton/ Havells/Wipro/Halonix/Panasonic/PAC)
32A modular DP switch
Track Light
SITC of 26-30 w LED Track zoomable track spot light 10-60°, color 3000k&4000k, all complete as per direction of Engineer-in-Charge. (UNECOTRACKLIGHTTS30WLED)(Makes-Philips /Crompton/ Havells)
SITC of Track for fixing of Track Light-make Havells or Equivalent
Air conditioning
Cassette AC System
Providing & fixing cassettes 2tr AC units
S/F 2 Ton 3-Star Cassette Ac, Make Lloyd, Model-GLC24B3XWAAG OR Equivalent
Refrigerant Piping
supply & laying of Interconnecting refrigerant pipe work with (9 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per Engineer-in-Charge.STD. & specifications, all piping inside the room shall be properly supported with MS hanger.
Drain Piping
Cassette PVC drain piping
Supply and Installation of PVC Drain pipes (Suitable for 10 Kg/cm2 Water Pressure) with fittings such as reducer, Tee, Socket, Elbow & duly insulated with 6mm Nitrile Rubber insulation
32 mm dia
S/F of Outdoor Unit Wall mounting Stand with Anchore fastener (Heavy duty for 2 Ton and above AC Machines)
Electrical Cabling.
Supply of following Copper armoured XLPE cables insulated ISI marked.(Make- Havells/ Polycab/ KEI / RR)
4cx4sqmm
Showcase
Providing and fixing of showcase as per international standard, minium air transfer
11thk Glass extra clear Laminated Safety glass
Powder coated metal structure with seemless finish not showing any screw from outside
Providing and fixing Plinths and shelfs made of glass/ CARB P2 MDf(low formaldehyde emition) paint- waterbase paint with full curing cicle as per requirement
Size 5'x3' depth-1'3" (internal size) reff drawing for size and specifications, all complete as per direction of Engineer-in-Charge.
Size 5'x4'6" depth-1'8" reff drawing for size and specifications, all complete as per direction of Engineer-in-Charge.
Vishalaakshi Consultants
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .