Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.6 LAdmitted-Fee/PreQual/Technical/Finance | -37.63% | ₹2.6 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹3.1 L+₹53,021.70 (20.3%)Admitted-Fee/PreQual/Technical/Finance | -25.00% | ₹3.1 L+₹53,021.70 (20.3%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹3.3 L+₹69,814 (26.7%)Admitted-Fee/PreQual/Technical/Finance | -21.00% | ₹3.3 L+₹69,814 (26.7%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹3.5 L+₹90,132.69 (34.4%)Admitted-Fee/PreQual/Technical/Finance | -16.16% | ₹3.5 L+₹90,132.69 (34.4%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹4.2 L+₹1.5 L (58.6%)Admitted-Fee/PreQual/Technical/Finance BIKANER BIKANER RAJASTHAN | -1.11% | ₹4.2 L+₹1.5 L (58.6%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.2 L
EMD Value
₹8,396
Closing Date
14 Sept 2026, 9:00 amClosed
EE 14th Division IGNP Bajju
EE 14th Division IGNP Bajju
Fencing and Electrification work of Vth type quarters at CC RD 931 Bajju
2026_IGNP_595708_1
NIB 03
Open Tender
Civil Works
Percentage
90 days
RD 931 Bajju
As per BID
2 documents required · 2 mandatory
₹500
EE 14th Division IGNP RD 931 Bajju
₹8,396
Yes
15 Sept 2026
7 Sept 2026
14 Sept 2026
7 Sept 2026
14 Sept 2026
7 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with four horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete.As per PWD BSR 2026.Ch.No.-9,Item no-9.32 | 684 | mtr | 517 | ₹3,53,628 |
| 2 | Clearing jungle including uprooting of rank vegetation , bushes,shurbs , brush wood , trees and sapling of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared As per IGNP BSR 2026,Ch no-6,Item No.-1 | 10,000 | Sqm | 2.5 | ₹25,000 |
| 3 | Earth work excavation in ordinary soil, kassi work undressed As per IGNP BSR 2026,Ch no-7,Item No.-1 | 2.16 | Cum | 70 | ₹151.2 |
| 4 | Brick masonary in foundation and plinth with brick designation 75 In cement sand mortar 1:5 + For using brick class designation 100 instead of class designation 75 For brickwork in square or rectanglar pillars, As per IGNP BSR 2026,Ch no-10,Item No.-6.d+7.a+7.d | 3.37 | Cum | 5,961 | ₹20,088.57 |
| 5 | Cement plaster with cement sand mortar (1:3) including racking of joints, smooth finishing and curing etc.complete including all leads of all construction materails of thickness. 12 mm thick in 1 coat (IGNP Bsr 2026,Ch no,-11,item no -2.3) | 7.2 | Sqm | 219 | ₹1,576.8 |
| 6 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. Short point (up to 3 mtr.) As per PWD BSR 2025 item no. 1.1.1 | 8 | Point | 291 | ₹2,328 |
| 7 | Medium point (up to 6 mtr.) As per PWD BSR 2025 item no. 1.1.2 | 12 | Point | 509 | ₹6,108 |
| 8 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. As per PWD BSR 2025 item no. 7.38 | 4 | Each | 460 | ₹1,840 |
| 9 | Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. As per PWD BSR 2025 item no. 7.20 CH no.7 | 4 | Nos | 186 | ₹744 |
| 10 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. 2 x 4.0 sq.mm As per PWD BSR 2025 item no. -4.1.11 CH no.4 | 25 | mtr | 107 | ₹2,675 |
stage.html
html • 0.03 MB
finance_1056650.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_1056650.xls
BOQ • 0.35 MB
condnewnonplan.pdf
Additional Documents • 0.13 MB
bidnonplan.pdf
Tender Documents • 11.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .