Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.7 L+₹74,089.40 (3.09%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹25.0 L
EMD Value
₹50,100
Closing Date
4 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMMU
GE AF JAMMU AIR FORCE STATION JAMMU
GE/AFJ-06/2020-21 PROVN OF EXTERNAL LADDER AT SRE BLDG AND PROVN OF CERTAIN REVENUE WORKS AT AF STN JAMMU
2020_MES_363091_2
CA NO GE/AFJ-06/2020-21
Open Tender
Civil Works
Item Rate
180 days
JAMMU
AS PER POLICY IN VOGUE AND AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹50,100
Yes
2 Feb 2021
2 Dec 2020
5 Jan 2021
2 Dec 2020
4 Jan 2021
15 Dec 2020
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engineer-in-charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and as directed by Engr-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engineer-in-charge.
Reinforced cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engineer-in-charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engineer-in-charge.
TMT mild steel bars, 5mm dia and over upto and including 10mm dia, as in stirrups, spacers & binders, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engineer-in-charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engineer-in-charge.
Reinforced cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and the like all as specified and as directed by Engineer-in-charge.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and as directed by Engineer-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and as directed by Engineer-in-Charge.
Cutting holes in RCC/stone/cement brick walls for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required having depth of embedded portion of hold fasts or lugs measured from the face of the jamb into the wall of thickness exceeding half brick but not exceeding one brick thick but complete all as specified and as directed by Engineer-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-in-charge.
Strutural tubular steel as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming to Fe 410-W (Gde-E- 250) quality-A complete all as specified and as directed by Engineer-in-Charge. Make and Procurement: All as specified in PS clause No 8 of tender documents
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to Fe 410-O or 310-O, complete all as specified and as directed by Engineer-in-charge.
Mild steel bolts machine made with hexagonal or square head one end each screwed other end to be fitted with washers and one hexagonal or square nut, exc 22.50 cm long but n.exc 60 cm long and dia of neck exc. 16 mm but n. exc. 20 mm complete all as specified and as directed by Engineer-in-Charge.
Fe 410-W (Gde-E- 250) qualiy A, rolled mild steel sections as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, etc. complete all as specified and as directed by Engineer-in-charge.
Anodised aluminium frame for doors, windows, ventilators and partition with one or more rebates including joining cleat for fixing etc., section 100 x 44.50 mm made from 1.50 mm thick aluminium powder coated (minimum 50 micron thickness) complete all as specified and as directed by Engineer-in-Charge. Make: JINDAL/INDAL/HINDALCO
Anodised aluminium powder coated (minimum 50 micron thickness) door shutters, fixed type with sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodized aluminium fittings such as 150mm long (4 Nos) hinges, 200mm long (2 Nos) suitable handles, 250 mm long aluminium Tower bolt (01 No), 140mm long aluminium door stopper 01 No and aluminium snap beading, screws, etc. complete all as specified and as directed. Make: JINDAL/INDAL/HINDALCO
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar 1:4, complete all as specified and directed by Engineer-in-charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for coloured vitrifired ceramic tiles light shade tiles 10 mm thick, area of each tile n exc 0.36 Square metre as in floors and the like, set and jointed in neat cement slurry and pointed in colored cement to match Shade, pattern, laying etc of tiles, over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 including finishing the surfaces even and rough for receiving tiles complete all as specfied and directed. MAKE: KAJARIA/JOHNSON/ORIENT BELL/ NITCO/SOMANY
100mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engineer-in-charge.
Pre-cast cement concrete block masonry with solid blocks, type C1 1:3:6 (20mm graded crushed stone aggregates) exceeding 10 cm in width and setting in mortar 1:4, as in kerb stones laid and jointing to edges of hardstanding complete all as specified and as directed by Engineer-in-charge.
Machine pressed / vibro mechenically floated interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of grey cement and pigment, laid over and including 25mm thick sand cushioning complete. Shape pattern of laying shall be approved by Engineer-in-charge. Make: NTC/NITCO/ULTRA /JOHNSON
Preparing plastered or unplastered old decorated surfaces of wall and applying one coat of weather proof exterior (water based) emulsion paint to be applied in caumoflaging pattern in dark colour as approved by user complete all as specified and as directed by Engineer-in-charge. MAKE: APEX ULTIMA OR BERGER (WEATHER COAT ALL GUARD)/ASIAN (APEX ULTIMA)/NEROLAC (EXCEL TOTAL)/ JEHNSON & NICHOLSON/DULUX ICI
Preparing newly plastered or unplastered surfaces of walls and applying two coats of weather proof exterior (water based) emulsion paint to be applied in caumoflaging pattern in dark colour as approved by user complete all as specified and as directed by Engineer-in-charge. MAKE: APEX ULTIMA OR BERGER (WEATHER COAT ALL GUARD)/ASIAN (APEX ULTIMA)/NEROLAC (EXCEL TOTAL)/ JEHNSON & NICHOLSON/DULUX ICI
Preparing newly plastered or unplastered surfaces of walls and ceiling and applying two coats of oil bound distemper over and including 1 mm thick single layer of wall care putty (of Make Birla White/ASIAN PAINTS/BIRLA PAINTS/ NEROLAC/JK CEMENT/ BERGER PAINTS) complete all as specified and as directed by Engineer-in-charge. MAKE: BERGER PAINTS/ASIAN PAINTS/ NEROLAC/JEHNSON & NICHOLSON/ICI DULUX/NEROLAC PAINTS
Preparing plastered or unplastered old decorated surfaces of wall/ceiling and applying one coat of oil bound distemper complete all as specified and as directed by Engineer-in-charge. MAKE: BERGER PAINTS/ASIAN PAINTS/ NEROLAC/JEHNSON & NICHOLSON/ICI DULUX/NEROLAC PAINTS
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide/zink chrome primer, complete all as specified and as directed by Engineer-in-charge. MAKE: BERGER PAINTS/ASIAN PAINTS/ NEROLAC/JEHNSON & NICHOLSON/ NEROLAC PAINTS/GOODLASS
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out, returning, filling in, in any type of soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engineer-in-charge.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge. Make and Procurement: All as specified in PS clause No 8 of tender documents
Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe 410-W (Gde-E- 250) quality-A, complete all as specified and as directed by Engineer-in-charge.
Prepainted colored trapezoidal profiled Galvalume/ Zincalume coated steel sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy mettalic coating 550 MPA yield stress as per AS-1397), as in roof covering/cladding to wall fixed with self tapping screws colour/exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling/self-tapping fastener (12-14 x 55 with EPDM seals) complete all as specified and directed by Engr-in-Charge Make : Tata Blue Scope Steel Ltd/JSW Steel Ltd/CRIL
Two coats of cement base paint on new/undecorated wall surfaces including preparation of surfaces and including curing before and after each coat complete all as specified. MAKE: SNOWCEM/ASIAN/JEHNSON & NICHOLSON/BERGER/DURACEM
Steel tubes 15 mm bore, ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. MAKE: JINDAL PIPES/TATA/PRAKAASH SURYA
Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes, complete, all as specified and as directed by Engr-in-Charge. MAKE: CERA/HINDWARE/PARRYWARE
600 mm x 450 mm mirror of thickness 5/5.5mm of slected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete, all as specified and as directed by Engr-in-Charge. MAKE: SAINT GOBAIN/MODI GUARD TRIVENI FLOAT GLASS
15mm bore pillar tap cast copper alloy chromium plated screwed downhigh pressure, with or without lettered 'hot or cold' with long screwed shanks and fly-nuts screwed for iron pipe, complete all as specified and directed by Engineer-in-Charge. MAKE: MARC/ESS ESS/KOHLER/JOHNSON
40 mm thick Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in floors and finished the surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Supply only glass dividing strips, 1.5mm thick, 38mm width of strip inserted in position, conform to design complete all as specified and directed by Engr-in-charge.
Rotational moulded polyethylene water storage tank, inner and out white, two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 2000 litres each including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, complete all as specified and as directed by Engr-in-Charge. MAKE: SINTEX/POLYWELL/ROTEX POLYCON
Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 grams), fixed in repairs complete all as specified and as directed by Engineer-in-charge.
Reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-charge.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough flat finished surfaces complete all as specified and as directed.
TMT mild steel bars, 6 to 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engineer-in-charge.
Factory made steel ventiletors conforming to IS-1038 with side hung shutters including pintal hinges with 02 Nos mild steel tower bolts of 150 mm long on each shutter, steel handle and stopper of Z section with sash bars dovetailed or welded for securing glass without guard bars/grills complete all as specified and directed by Engineer-in-Charge. (Note :- Glass panes shall be measured and paid for separately). MAKE: M/S AGEW STEEL MANUFACTURE PVT LTD AHMEDABAD/M/S SHIV MULARA NARODA AHMEDABAD/GODREJ AND BOYCE MFG MUMBAI/SEN HARVIC MUMBAI/SHIVAM STEEL JAMMU
Solid factory made PVC Door frame of size 50mmx47mm made out of 5mm plain color PVC sheet reinforced with MS Square tube, supply and fixing in opening as per specification and drawings and incluiding making good disturbed surfaces complete all as specified and directed. MAKE: SINTEX INDUSTRIES/RAJSHRI PLASTIWOOD LTD/M/S DURA PLAST EXTRACTION PVT LTD/FENESTA/ POLYTUFF
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single side Prelam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of single side Prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails having one side feathered edge and on other side 10mm 90 degree bent edge with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and as directed. MAKE: SINTEX INDUSTRIES/RAJSHRI PLASTIWOOD LTD/M/S DURA PLAST EXTRACTION PVT LTD/FENESTA/ POLYTUFF
Butt hinges, medium weight, cold rolled mild steel and fixed with screws to PVC frames, 100 mm size, ISI marked, complete all as specified and directed by Engineer-in- Charge.
Aluminium handles, cast type anodized of size 125 mm, ISI marked, complete all as specified and directed by Engineer-in- Charge.
125 mm long aluminum ISI marked anodised, barrel tower bolts extruded section, complete all as specified and directed by Engineer-in-Charge
Plain Sheet glass 3.00 mm thick, ordinary quality and glazing with oil pane putty in squares not exceeding 0.5 Sq. mm in each pane, complete all as specified and as directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar 1:6, complete all as specified and directed by Engr-in-charge.
Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar 1:3 complete all as specified and directed by Engineer-in-Charge.
Supply only Liquid Water Proofing admixture complete all as specified and directed by Engr-in-charge.
M/L Cement concrete 1:3:6 type C2 using 40mm graded stone crushed aggregate in plinth protection, 50mm thick, finished even and smooth using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and as directed.
75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in mass concrete, filling & sub base to floors, complete all as specified and as directed by Engineer-in-charge
Preparing new plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store, complete all as specified and directed by Engineer-in-Charge.
Steel tubes 20 mm bore, ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge. MAKE: JINDAL PIPES/TATA/PRAKAASH SURYA
Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20cm girth, complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceremic tiles 300 x 450 x 7 mm thick, as in dado, vertical surfaces set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 10 mm thick rendering in CM (1:4) complete all as specfied and directed. MAKE: KAJARIA/H&R JOHNSON/CERA/ NITCO/SOMANY
M&L for Granite work 18-20mm thick (Table rubbed and polished) in cooking platforms and like set in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shede complete all as per specified and as directed.
BLANK
BLANK
BLANK
100mm bore cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, with cement joints, fixed to wall including dismantling of old broken unserviceable CI pipe complete all as specified and as directed by Enginner-in-Charge. Make: SRIF (GOLD CASTINGS)/NECO (JAYASWAL)/HIF MATHURA/SKF
75mm bore cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, with cement joints, fixed to wall including dismantling of old broken unserviceable CI pipe complete all as specified and as directed by Enginner-in-Charge. Make: SRIF (GOLD CASTINGS)/NECO (JAYASWAL)/HIF MATHURA/SKF
50mm bore cast iron soil, waste and vent pipes (sand cast) in any length with or without ears, with cement joints, fixed to wall including dismantling of old broken unserviceable CI pipe complete all as specified and as directed by Enginner-in-Charge. Make: SRIF (GOLD CASTINGS)/NECO (JAYASWAL)/HIF MATHURA/SKF
Cast iron bends (any radius), 100mm bore, diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Enginner-in-Charge. Make: SRIF (GOLD CASTINGS)/NECO (JAYASWAL)/HIF MATHURA/SKF
Bends (any radius), 75mm bore, diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by Enginner-in-Charge. Make: SRIF (GOLD CASTINGS)/NECO (JAYASWAL)/HIF MATHURA/SKF
Mild steel stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, suitable for 75mm bore CI pipe complete all as specified and as directed by Enginner-in-Charge.
Mild steel stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, suitable for 50mm bore CI pipe complete all as specified and as directed by Enginner-in-Charge.
Stainless steel grating 125mm dia square or round, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
BLANK
BLANK
BLANK
Rotational moulded polyethylene water storage tank, inner and out white, two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, complete fixed in repairs, all as specified and as directed by Engr-in-Charge. MAKE: SINTEX/POLYWELL/ROTEX POLYCON
1200 mm x 6000 mm mirror of thickness 5/5.5mm of slected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete, fixed in repairs all as specified and as directed by Engr-in-Charge. MAKE: SAINT GOBAIN/MODI GUARD TRIVENI FLOAT GLASS
BLANK
BLANK
BLANK
Supply and fixing corner glass shelf with brackets complete all as specified and as directed. Make: Cat part No ACN-1173 of Jaquar or equal approved in Kohlar
Supply and fixing in repairs bathroom cabinet PVC frame box type with mirror in front of size 600 x 450mm fixed to wall with screws complete all as specified and as directed by Engineer-in-Charge. MAKE: SAINT GOBAIN/MODI GUARD TRIVENI FLOAT GLASS/PARRYWARE/ JOHSON PEDDER
BLANK
Supply and fixing vitreous china wall hung water closet with inbuilt jet, UF soft close slim seat cover, hinges, along with accessories set, size 365 x 515 x 390mm long with all fittings complete all as specified and as directed. Make: Cat part No SLS-WHT-6951JUFSM of Jaquar or equal approved in Kohlar
Supply and fixing table top basin of size 630 x 425 x 160mm including all fittings complete all as specified and as directed. Make: Cat part No JDS-WHT-25901 of Jaquar or equal approved in Kohlar
Supply and fixing single piece slip concealed cistern with floor mounting frame, installation kit and 'S' type drain pipe connection set for wall hung water closet (without flush control plate) complete all as specified and as directed. Make: Cat part No JCS-WHT-2400FS of Jaquar or equal approved in Kohlar
Supply and fixing waste coupling 32mm size full thread with 130mm height along with waste pipe complete all as specified and as directed. Make: Cat part No ALD-CHR-705L130 of Jaquar or equal approved in Kohlar
Supply and fixing exposed part kit of single lever basin mixer wall mounted consisting if operating lever, wall flange, nipple and spout (suitable for item having cat part ALD 233 and ALD 235) complete all as specified and as directed. Make: Cat part No VGP-CHR-81233K of Jaquar or equal approved in Kohlar
Supply and fixing brush holder for water closet, alongwith all fittings complete all as specified and as directed. Make: Cat part No ACN-CHR-1143N of Jaquar or equal approved in Kohlar
Supply and fixing optima sliding DR 8mm RT, with towel rod (1500-2000mm) x 2000mm complete all as specified and as directed. Make: Cat part No JSE-CHP-OPTSDR1520TR of Jaquar or equal approved in Kohlar
Supply and fixing concealed body for single lever basin mixer wall mounted with cartrige sleeve but without exposed part complete all as specified and as directed. Make: Cat part No ALD-CHR-233 of Jaquar or equal approved in Kohlar
Supply and fixing Jaquar sefly-SWR PNL JAQ anti finger print with stainless steel finish 1600 x 200mm complete all as specified and as directed. Make: Cat part No JPL-SSF-ST88158B of Jaquar or equal approved in Kohlar
Supply and fixing regular body of concealed stop cock suitable for 15mm bore pipe line, with protection CAP (without exposed parts) complete all as specified and as directed. Make: Cat part No ALD-CHR-083 of Jaquar or equal approved in Kohlar
Supply and fixing exposed part kit of concealed stop cock and flush cock with fitting sleeve, operating lever and adjustable wall flange with seal (compatible with items having cat Part No ALD-083, ALD-089 and ALD-081) complete all as specified and as directed. Make: Cat part No VGP-CHR-81083K of Jaquar or equal approved in Kohlar
Supply and fixing 15mm bore angular stop cock CP with wall flange complete all as specified and as directed. Make: Cat part No VGP-CHR-81053 of Jaquar or equal approved in Kohlar
Supply and fixing health faucet manually operated (Hand held) complete set with CP Nipple-01 (100/50mm as required) and CP Tee-01 No connected to existing taps with 8mm dia 1.20 metre long flexible tube and wall hooks complete all as specified and as directed. Make: Cat part No ALD-CHR-573 of Jaquar or equal approved in Kohlar
Supply and fixing control plate vignette prime (K5140) complete all as specified and as directed. Make: Cat part No JCP-CHR-812415 of Jaquar or equal approved in Kohlar
Supply and fixing artificial marble ledge 1601-2000mm complete all as specified and as directed. Make: Cat part No ESA-BGE-LDG 1620 of Jaquar or equal approved in Kohlar
Supply and fixing towel rack 600mm long with lower hangers, stainless steel complete all as specified and as directed. Make: Cat part No ACN-CHR-1181S of Jaquar or equal approved in Kohlar
Supply and fixing towel ring round with round flange complete all as specified and as directed. Make: Cat part No ACN-CHR-1121BN of Jaquar or equal approved in Kohlar
Supply and fixing soap dish holder complete all as specified and as directed. Make: Cat part No ACN-CHR-1131N of Jaquar or equal approved in Kohlar
Supply and fixing tumbler holder complete all as specified and as directed. Make: Cat part No ACN-CHR-1141N of Jaquar or equal approved in Kohlar
Providing, cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, bed blocks for hold fasts, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts and the like all as specified and as directed by Engineer-in-charge.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished surface of flat concrete complete all as specified and as directed.
M&L for Granite work 18-20mm thick (Table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as per specified and as directed.
Surface dressing not exceeding 15 centimetre deep in any type of soil complete all as per specified and as directed.
100 mm thick Plain cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregates) as in floors and finished the surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and as directed by Engineer-in-charge.
Broken stone hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge
Mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated) conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and as directed by Engineer-in-charge.
Preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of air cooled split units air conditioner, indoor and out door units, electric driven, single phase 230 volts, 50 Hz with 3 metre copper pipe duly insulated and electtrical cable of suitable size, mounting brackets and required accessories for installation and commissioning with following specifications: - (a) Capacity - 2.0 ton rating/6500 Kcal/Hour (b) Technology - Variable speed dual Inverter Technology (c) Compressor Type - High EER rotory compressor (d) Operating Voltage range - 145V-270V (without stabilizer) (e) Condenser Coil - 100% Copper (f) Star rating - 5 Star (g) Warranty on compressor - Minimum 5 years (h) Warranty on machine - Minimum 01 year (j) Air filter - Anti dust, anti bacteria Make: Blue star 2 ton 5 star inverter split AC Cat part No 5CNHW24PAFU or equal approved in Voltas/Hitachi
Supply, installation, testing and commissioning of air cooled split units air conditioner, indoor and out door units, electric driven, single phase 230 volts, 50 Hz with 3 metre copper pipe duly insulated and electtrical cable of suitable size, mounting brackets and required accessories for installation and commissioning with following specifications: - (a) Capacity - 1.50 ton rating/4500 Kcal/Hour (b) Technology - Variable speed dual Inverter Technology (c) Compressor Type - High EER twin rotory compressor (d) Operating Voltage range - 145V-270V (without stabilizer) (e) Condenser Coil - 100% Copper (f) Star rating - 5 Star (g) Warranty on compressor - Minimum 5 years (h) Warranty on machine - Minimum 01 year (j) Air filter - Anti dust, anti bacteria Make: Voltas 1.50 ton 5 star inverter splict AC Cat part No VOLTAS 185 VMZM or equal approved in Blue star/Hitachi
Sub main wiring with two runs of 6 Sqmm (2x6 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories etc with one run of 4 Sqmm (1x4sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, including cutting chases in wall for PVC conduit, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm), one run of 4 Sqmm (1x4 sqmm) cable and one metre of conduit will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ ANCHOR/POLYCAB Make of conduit: PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Supply and fix sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge. Make : Legrand cat part No 5078 11 or or equal approved in Schneider/ABB.
Supply and laying DWC (Double wall corrugated HDPE pipe, ISI marked, IS-14930 Part-II, having outer dia 40mm and inner dia 32mm with smooth internal and profiled external surface of non pressure under ground cable including all connected accessories like coupler, 'O' ring, etc, for protection of cable complete all as specified and as directed. MAKE: SUPREME /ASHIRWAD / FINOLEX / SFMC / ASTRAL / PRESTO PLAST
Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm, 2 core, complete all as specified and directed by Engr-in-Charge. MAKE : FINOLEX/UNIVERSAL/RPG CABLES KE I INDUSTEIES PVT LTD/POLYCAB/ GLOSTER
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :-
(a) Excavation and earth work for drilling hole for electrode in any type of soil.
(b) PCC pit in cement concrete 1:2:4 type B-1.
(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
(d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
(e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering.
(f) Requisite quantity of common salt and charcoal.
(g) Testing of earthing.
Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Supply and fixing MCB distribution board Double door SPN 230 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing MCB SPN 32/40 Amps, 230 V, AC complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4086 09 to 4086 17 of Legrand (DX³) or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Supply and fixing MCB SP 5 to 32 Amps, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4085 87 to 4085 95 of Legrand (DX³) or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
M/s Mohan lal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .