| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC DINJAN P O DINJAN DIST DIBRUGARH ASSAM 786 183 E 4 CWE DINJAN | DIBRUGARH | ASSAM | 786183 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.7 L+₹43,270 (2.04%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.8 L+₹54,680 (2.57%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹22.5 L+₹1.3 L (5.98%)Rejected-Finance BORBARUAH BAZAR A T ROAD DIBRUGARH ASSAM | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹25.8 L+₹4.5 L (21.4%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
7 Nov 2020, 6:00 pmClosed
GE (AF) Mohanbari
GE (AF) Mohanbari
REPAIR AND MAINTENANCE OF PERIMETER LIGHT, STREET LIGHT, BUILDING SECURITY LIGHTS, POST TOP LAMPS AND MISC E/M NATURE WORKS AT AF STN DINJAN UNDER GE (AF) MOHANBARI.
2020_MES_374168_3
NIT No . 8001/244/01/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AFS Dinjan
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Mohanbari
₹40,000
Yes
18 Jan 2021
23 Oct 2020
9 Nov 2020
23 Oct 2020
7 Nov 2020
24 Oct 2020
Amount
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5 m in depth for laying of cables, pipes/pole/stay etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in Soft/loose soil, making the surface plain complete all as specified and directed by Engineer-in-charge.
Supply and spreading dry coarse sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18 cm complete all as specified and directed by Engineer-in-charge. (Note: Punned thickness shall be measured and paid. )
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for well burnt bricks having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Laying only old burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed by Engineer-in-charge.
Boring/Drilling (horizontally) manually under existing road (without disturbing the top surface of road) suitable for passing cable protection pipe etc complete all as specified and directed by Engineer-in-charge.
Material and labour for painting of erected steel tubular swaged poles of LT over head line ( Except embedded portion), 8.5/9 M long complete including all MS work mounted on pole , earth protection & water pipe ( if exists) with two coat of aluminium paint after necessary preparation and providing 07 Nos bands/ straps with synthetic enamel paint ( any tint 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on black ground complete all as specified and directed by Engineer-in-charge.
Supply and installation of steel tubular swaged poles type 410 SP-31 (9 mtr long) complete with CI base plate and finial taper plug, bolts, nuts and screws including Dismantaling of old poles complete all as specified and directed by Engineer-in-charge. Note :- Excavation, earth work and PCC only will be measured and paid separately, all other accessories and other works deemed to be included in the unit rates quated by the contractor.
M&L plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations/mass concrete complete all as specified and directed by Engineer-in-charge.
Material and labour for plain cement concrete 1:3:6 type C2 using 40 mm graded crushed stone aggregate as as in foundations/mass concrete complete all as specified and directed by Engineer-in-charge.
Material and labour for plain cement concrete type C1 (1:2:4), using 20 mm graded crushed stone aggregate, as in pedestal coping including necessary formwork finished fair using extra cement complete all as specified and directed by Engineer-in-charge.
Material and labour for dismantling and taking down of existing unserviceable single fittings for repair, maintenance of street/ security/ perimeter/ garden/post top lantern light fittings etc of LED of any wattage or make from pole/ wall/ building/ tower at any height by disconnecting electrical connections and repairing by split opening the same in to the parts for fault finding and replacement of unserviceable spare parts i.e. surge arrestor, LED driver, wire, pipe etc with same capacity, testing and refixing at same location or as directed after necessary repair complete all as specified and directed by Engineer-in-charge. Note :- (i) The Supply of spare parts i.e. surge arrestor, LED driver, wire, pipe etc shall be measured and paid seperately. (ii) minor spare parts such as nuts, bolts, washers, cotton waste etc deemed to be included in the quoted rates. (iii) Inventory of all defective parts required to be replaced will be recorded in a separate register alongwith pole No & location / area and type of light fittings before replacement duly signed by JE, Engineer-In-Charge & contractor and the same shall be produced at the time of payments for verification.
Supply and fixing in repair LED Street light driver 60 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge. (Make:Bajaj/Havells/Surya/Crompton)
Supply and fixing in repair LED Street light driver 80 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge. (Make:Bajaj/Havells/Surya/Crompton)
Supply and fixing in repair LED Street light driver 120 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge. (Make:Bajaj/Havells/Surya/Crompton)
Supply and fixing in repair LED Street light driver 150 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge. (Make:Bajaj/Havells/Surya/Crompton)
Supply and fixing in repair LED Street light driver 200 watts for suitable LED fittings complete all as specified and directed by Engineer-in-charge. (Make:Bajaj/Havells/Surya/Crompton)
Supply only surge protection devices compatible with industrial & outdoor LED voltage 5 KV fixtures upto rated power of 75 W for suitable LED fittings complete all as specified and directed by Engineer-in-charge. (Make:Bajaj/Havells/Surya/Crompton)
Supply only surge protection devices compatible with industrial & outdoor LED voltage 5 KV fixtures rated power above 75 W and upto 150 W for suitable LED fittings complete all as specified and directed by Engineer-in-charge. (Make:Bajaj/Havells/Surya/Crompton)
Supply and fixing in repair GI bracket for street light made out of 40 mm dia GI pipe light grade 1.2 metre in length bend in shape as required including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed by Engineer-in-charge.
Supply & fixing in repair loop in loop out polycarbonate Junction box in accordance with IEC 60670-22 of size 200 mm x 160 mm x 98 mm, suitable for LT cable 16/25 sqmm with front openable hinged cover and locking arrangements with IP 66 degree of protection, with MCB 'C' series, 6 Amps, Single Pole, 10 KA, 240 volts and aluminium bus bar of suitable capacity complete with electrical connection fixed to pole/wall with suitable size FI clamp 20mm x 3mm, nuts, bolts and washer including duty painted with powder coated paint complete all as specified and directed by Engineer-in-charge.
Material and labour for taking out defective/ burnt out LT underground cable including loop and protection pipe from base of street light pole including demolition of PCC coping of pole if required and cutting faulty cable and jointing cable with jointing kit suitable for LT cable of size uptp 50 sqmm sqmm 4.0/3.5 core and fixing cable in existing position with dismantled cable protection pipe and cable covers etc including testing complete all as directed. Note: (i) LT joint kit and earth work shall be measured & paid separately under relevant item of this schedule. (iii) Coping and extra cable required for the job shall be measured and seperately under relevant item of this schedule.
Material and labour for straight through joints size 6 sqmm to 16 sqmm, 4 core/ 3.5 core (epoxy type) for LT PVC/XLPE insulated armoured aluminium conductor cable including jointing and testing complete all as specified and directed by Engineer-in-charge. (Note:- Cutting of faulty cable/joint is deemed to be included in the above quoted rates.)
All as per Item No. 24 above but size 25 sqmm to 50 sqmm, 4 core/ 3.5 core
Disconnecting and taking out the existing unserviceable LT cable of any size, Supply and fixing/laying/connecting, testing and commissioning XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with multistranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 4 core laid in trench /poles/on wall/floor in ducts etc including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceiling / walls without cable duct) as required at site complete all as specified and directed by Engineer-in-charge. (Note: 1. Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items 2. Serviceable bricks obtained will be kept aside for re-use under relevent item.)
All as per item No.26 above but 16 sqmm 4 core.
All as per item No. 26 above but 25 sqmm 3.5 core.
Supplying and laying in repairs 15mm bore galvanised mild steel pipe /tubing, light grade complete with all fittings, for protection of cable, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed by Engineer-in-charge. (Note : Excavation & Earth work shall be measured and paid separately)
Supplying and laying in repairs 50mm bore galvanised mild steel pipe /tubing, light grade complete with all fittings, for protection of cable, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed by Engineer-in-charge. (Note : Excavation & Earth work shall be measured and paid separately)
Supply and Fixing in repair PVC insulated, PVC round sheathed, copper conductor cable 1.5 Sqmm two core for connection of street light/ flood light/ post top lantern etc on pole /wall/ pillar from over head conductor/ junction box/ DB including termination clip etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 25 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 60 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 80 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 120 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 150 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 200 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
Supply and fixing for LED flood light, suitable for high mast application, epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 180 Watt, non integral IP-66 with all acessories including taking down unserviceable light and removing from work site complete all as specified and directed by Engineer-in-charge.
Supply and fixing for LED flood light, suitable for high mast application, epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 200 Watt, non integral IP-66 with all acessories including taking down unserviceable light and removing from work site complete all as specified and directed by Engineer-in-charge.
Supply and fixing for LED flood light, suitable for high mast application, epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 90 lumen per watt, system wattage 300 Watt, non integral IP-66 with all acessories including taking down unserviceable light and removing from work site complete all as specified and directed by Engineer-in-charge.
Supply and fixing for LED Post Top lantern having Die-cast aluminium graphite grey powder coated spigot housing, spun aluminium graphite grey powder coated finish housing, die-cast aluminium decorative designer top, Opal polycarbonate diffuser, and low powder LEDs connected in series and parallel combination with better heat dissipation arrangement, noiminal voltage 240 Volts, system wattage 25 Watt, delivering lumen equal to/greater than 90 lumen per watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed by Engineer-in-charge.
M/s T D Sen and Co
M/s Shiva Technical Enterprise
M/S Abhi Traders
M/S RK Trading
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .