| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.3 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹34.2 L+₹2.3 L (7.23%)Rejected-Finance | L-2 | Rejected-Finance L-2 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
21 Jun 2023, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
SPECIAL REPAIR TO CERTAIN WATCH TOWERS AT AFS FARIDABAD IN AOR OF GE (AF) FARIDABAD (2ND CALL)
2023_MES_593821_2
GE (FBD)/AF-14/2023-2024
Open Tender
Civil Works
Item Rate
180 days
FARIDABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹94,000
Yes
2 Aug 2023
7 Jun 2023
23 Jun 2023
7 Jun 2023
21 Jun 2023
7 Jun 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris to outside the station where suitable for contractor complete all as specified and directed by Engineer-in-Charge.
Demolition of Concrete of any description and in any position not otherwise specifically provided for and disposal of debris to outside the station where suitable for contractor complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete all as specified and directed by Engineer-in-Charge.
Demolition brick work or stone/boulder masonary,built in cement mortar or cement lime mortar including all quions, arches pillars,etc but ashlar facing dressed stone work and precast concrete articles and disposal of debris to outside the station where suitable for contractor complete all as specified and directed by Engineer-in-Charge.
Taking down chowket or frame with shutter (without taking of shutter from frame) not exc 1.50 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down chowket or frame with shutter (without taking of shutter from frame) exc 1.5 sqm but not exe 4.00 Sq m each each complete all as specified and directed by Engineer-in-Charge.
M & L for Vitrified ceramic tiles Light Shade 10mm thick polished, area of each tile 600x600 Sqmm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match omplete all as specified and as directed by the Engineer-in-Charge
M & L for Vitrified ceramic tiles Light Shade 10mm thick polished, area of each tile 600x600 Sqm in walls etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, work on vertical surfaces such as skirtings, dados and risers to steps etc. complete all as specified and as directed by the Engineer-in-Charge
M & L for non-skid ceramic roof weathering tiles Light Shade 12 to 14 mm thick polished, area of each tile 400x400 Sqm in roof floor & stairs etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, with 15 mm tk screed bed of cement morter 1:4 or suitable camical as per manufacturer instruction complete all as specified and as directed by the Engineer-in-Charge
Demolition of reinforced cement concrete in roof, floors (other than ground floor), beams, stair case, landing, chhajas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (Design mix) M-25 in Columns, pillars, piers, postsand struts etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L TMT bars 10 mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (not less than 0.9 mm dia) or securing with clips quality conforming complete all as specified and directed by Engineer-in-Charge.
All as per item No 12 here-in-before but 6 mm to 8 mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides of Square,rectangular or polygonal pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer-in-Charge.
M/L for brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius built in cement mortal 1:6 using old size bricks complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with WPC @ of 3% of weight of cement complete all as specified and as directed by the Engineer-in-Charge.
M & L for rendering 15mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M&L for Setting coat 5mm thick, trowelled to even and smooth finish in cement mortar 1;2 in ceiling all as specified & as directed by Engineer-in-Charge
Supply only Liquid Water Proofing Compound complete all as specified and directed by Engineer-in-Charge.
M & L for preparing new surfaces of walls, distempering 2 coats with oil emulsion distemper white or tinted over one coat of wall care putty complete all as specified and as directed by the Engineer-in-Charge
M & L for preparing new surfaces of ceiling 2 coats of white wash in celing complete all as specified and as directed by the Engineer-in-Charge
M & L preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer (alkaliresistant priming paint) complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment in old plastered walls including preparation of old plastered surfaces and applying two coats of cement based paint in buildings upto ground plus three floor) complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of walls including preparing old plaster surfaces filling of holes with plaster of paris and applying two coat of oil bound distemper complete all as specified and directed by Engineer-in-Charge.
M&L for preparing old decorated wall surfaces , filling of holes and cracks with lime putty or plaster of paris and applying one coat of white wash on walls complete all as specified and directed by Engineer-in-Charge.
M & L for preparing old surfaces of ceiliong, one coats of white wash in celing complete all as specified and as directed by the Engineer-in-Charge
M&L for prepartion on new or old surface of steel , PVC, wood & iron work of any description not specifically mentioned otherwise over 10 cm width or girth & applying two coat of synthetic enamal paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Non skid coloured ceramic coloured plain tiles,300 x 300 x 7mm thick, conforming to Group B-IIA of IS-13712, first quality, laid in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Providing plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates, 25mm thick, as in floor/sub base and finishing concrete surface fair and even to receive top floor finishes complete all as specified and directed by Engineer-in-Charge.
Providing screed bed or bedding layer, 15 mm thick, in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
Glazed ceramic tiles, 300/350 x 450 x 7mm thick, glossy finish, conforming to Group B-III of IS-13712, first quality, of approved colour, laid on vertical surfaces such as skirting or dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Rendering, 10 mm thick, in cement mortar 1:4, on wall surafaces, as backing coat to tiles complete all as specified and directed by Engineer-in-Charge.
M&L for Dismantling floor, hearth or wall tiling including cement mortor bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type C-2 1:3:6 using 40mm graded aggregate as in plinth protection or path including necessary formwork complete all as specified and as directed by the Engineer-in-Charge
M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per Sqm of surface area, (with 20% EC) complete all as specified
Demolition of existing roof treatment (including pcc , plaster / brick tiles, mud etc) of any description and thickness upto roof slab on roof top including flashing and junction of parapet repair and disposal of debris to outside the station where suitable for contractor complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate RCC roof slabs to fill undulations to achieve uniform slope complete all as specified and directed by Engineer-in-Charge.
M&L for rendering over roof slab 10 mm thick in CM 1:3 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement and finished surfaces fair and even complete all as specified and directed by Engineer-in-Charge. (WPC shall be measured and paid separately)
M&L for APP based modified pre fabricated five layer, 3 mm thick and weighing not less than 3 Kg per Sqm water proofing membrane reinforced with non woven polyester mat 160 G Smith black finished over compatible primer conforming to IS-3488 @ 0.3 LT/Sqm, membrane laid by torch application side over lap of 75 mm and end overlap of 100 mm wide, joint/overlap sealed with torch applications for parapet etc the membrane taken up to 30 cm and then inserted inside the parapet after making necessary groove as required after necessary preparation of the surface comlete as per manufacturer's instruction all all as directed by Engr-in-Charge.
M&L for for two coat of aluminium paint over the roof ( APP membrane) all as directed by Engr-in-Charge.
Dismantling water tanks 250 to 500 ltrs capacity complete all as specified and directed by Engineer-in-Charge.
S&F Rotational molded polyethylene water storage tanks 3 layered, ISI marked (cylindrical vertical with threaded lid) hoisted and fixed in position all as specified in SSR Part-I of Capacity 500 litres with GI Tank Nipple inlet and outlet 20mm complete all as specified and directed by Engineer-in-Charge.
S&F Ball valve, high pressure with of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or fixed of size 20 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms) complete all as specified and directed by Engineer-in-Charge.
S&F Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S&F Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 25mm bore and fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing with connections complete of bore 15mm, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing with connections complete of bore 20mm, complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore ,UPVC high grade , including all fittings (like Elbow , Tee, Socket, Gi pipe connecter, nipples, tank connector etc) and fixing solutions/adhesive or chemicals and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm bore ,UPVC high grade , including all fittings (like Elbow , Tee, Socket, Gi pipe connecter, nipples, tank connector etc) and fixing solutions/adhesive or chemicals and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed by Engineer-in-Charge.
Mild steel structural steel work Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to Fe 290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
Mild steel framed work such as angles, flats, squre bars, grills, gratings, tank staging etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; door frame, ladders and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
M & L mild steel plates (Plain or chequred) channel square cut or not chequred (ordinary and counter sunk) ferming holes, sithout any attachment for Fe-410-W Gde-E 250 quality 'A' complete all as specified and directed by Engineer-in-Charge.
M&L for prepartion on new surface of steel & iron work of any description not specifically mentioned otherwise over 10 cm width or girth & applying two coat of synthetic enamal paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S&F for ECO 2000 series Approx size 1.5x1.2m (Elixir/NCL SECCOLOR)roll framed galvanised prepainted steel section windows section including provision of grills,4mm thick glass and SS wiremesh specification and drawing as per CE(AF) WAC,PALAM sheet no-1/2 and 2/2 of drawing no-CEAF/STD-191/2014 etc complete all as specified and directed by Engineer-in-Charge. (a)Fixing Details-rame and shutter frame sections should be cut to length and miter joined with poly propylene corner brackets,mullion section should be joined with frame/mullion using nylon mullion cap,ethyl propyllene diamene monomer(EPDM)gasket should be used all around glass in shutter and fixed glass.Rubber gasket should be used around the fly mesh to fix mesh in mesh shutter. (b)Accessories-Each Glazed shutter should be provided with MS powder coated friction hinges,high grade aluminium powder coated handle-1 for each shutter. (c)Glass shutter having fixed glass shall be 4mm th origin blue(ET725)GLASS,having U value of 3.85W/sqm K,light transmission factor of 18% and solar radiation factor of 0.23 for ST Gobin,HNG OR MODIGUARD. (d) Windows should be provided with grill made of 10mm SQR.MS Bars welded to at 150mm centre to centre,6mmx12mm MS flat.Total Grill unit should be powder coated and fixed to windows frame with screws. (e)Window frame should be fixed to Brick/concrete masonary by using nylons self expanding caps and driving MS electroplated 80mm long screws into the caps through frames. (f)Mesh shuuter should be provided with a stainless steel 32 guage fly mesh of 304 grades with 144 holes per sq inch.
M&L for factory made box type steel section ventilators using ERW hollow section fixed type with forsted glazing bar@ 10mm Squre bar@ 10Cm C/C and with one shop coat of zinc xhomate primer complete all as specified and directed by Engineer-in-Charge.
S & F 4 mm thick tinted glass, ordinary quality and glazing with oil putty or clips or in PTMT luvers (including all fittings like rubber/ putty/ luvers) in required shape to ventiletors complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick (styles) factory made solid panel PVC door shutters consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width tuck inside with solvent cement for styles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and joined together with solvent cement and fixing in the frame at site all as shown on drawing on page 146 of SSR Part-II 2004 including taking down the old PVC door shutters complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel tube & fixed in position as per manufacturer's instruction all as specified, as shown on drawing on page No 150 of SSR Part-II 2004 including taking down the old PVC door frame complete all as specified and directed by Engineer-in-Charge.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 59-60 (SuspensionGrade) ,calcium carbonate and natural fibers(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900N (Edge),minimum compressive strength 50 N/mm2,modulus of elasticity 850 N/mm2 and resistance to spread of flames of class A category with property of being termite /borer proof,water /moisture proof and fire retardant WPC to be laminated with PVC foil of minimum14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screw,all as per direction of Engineer-in-charge.(Note satinless steel butt hinges and necessary SS Screw shall be paid separately)PVC flush door 35 mm thk
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size 65x 125 mm in double ribbet comprising of virgin PVC polymer of K value 58-60(Suspension Grade),calcium carbonate and natural fibers (wood powder/rise husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frames density of 750 kg/cum ,screw withdrawal strength of 2200 N(face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2,modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixed in position with MS Hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge(M.S hold fast/lugs or SS Dash fasteners are included in this with this item complete) complete all as specified and directed by Engineer-in-Charge.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with. heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Single Side Prelam PVC sheet used and stile & rails having one side feathered edge and on other side 10mm 900 bent edge for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly, suppling & fixing in the frame at site as per specification & drawing.
S&F butt hinge, Stainless steel 100mm long complete all as specified and directed by Engineer-in-Charge.
S&F aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy 300 mm long and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Floor door stopper of aluminium alloy body double and tongue annodised with rubber shoe and fixed of size 150 mm complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed complete all as specified and directed by Engineer-in-Charge.
S&F extruded aluminium alloy handle fabricated type anodised 150 mm long complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 20mm wide door seal aluminium powder coated fixed with screws on bottom rails of door shutters complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass ordinary quality 3mm thick quality with oil putty or beads fixed with screws in sequence not exceeding 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/steel/Aluminium windows, or Stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F Brass 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete including taking down old one complete all as specified and directed by Engineer-in-Charge.
S&F in repair for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty all as specified and directed. including taking down old floor spring hydraulically complete all as specified and directed by Engineer-in-Charge.
S&F in Vitreous china squatting pan of Orissa Pattern size 580x 440 mm white with ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe fixed in repair including placing in position in floor and embedded in cushion of PCC 1:7:12 type E-1 using brick bats and finishing the top surfaces to match with the existing flooring complete all as specified and directed by Engineer-in-Charge.(Make: - Hindware/ Parryware/ Johnson )
S&F in vitreous china wash basin, Vitreous China any size, including Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms & cutting for and pinning in ends of bracket or erecting stand fixing of waste pipe etc complete all as specified and directed by Engineer-in-Charge.
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete including taking down by dismantling the existing unserviceable cistern of any description complete all as specified and directed by Engineer-in-Charge.(Make: - SLIMLINE (ECONOMY) with front knob of Parryware or equivalent in Hindustan Sanitary ware)
S&F 15 mm angle stop valves (fancy type),PTMT, screwed down high pressure witg crutch and butter fly handles , screwed with iron pipes or for union complete all as specified and directed by Engineer-in-Charge.
S&F in 15 mm bore , Pillar taps (fancy type), PTMT, with capstan heads,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in CP/PTMT health faucet with 1.00 to 1.50 metre long good quality stainless steel flexible pipe suitble for 15 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in PTMT CP shower rose of size 100/125mm with arm including fixing to steel pipes complete all as specified and directed by Engineer-in-Charge.
S&F Bib tap standard of PTMT any colour high pressure screwed for 15 mm bore iron pipe/ Cpvc pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in PVC waste pipe 800mm long suitable for 32mm dia waste coupling of plane PVC pipe (Not foldable type) of good quality sutable for WHB or urinal as directed by Engr in charge complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connections 15 mm size with PTMT nuts suitable for geaser of length 450 mm long complete all as specified and directed by Engineer-in-Charge.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends suitable for 110 mm external dia complete all as specified and directed by Engineer-in-Charge.
S&F in repair fancy stainless steel cloth hangers with minimum 04 hooks complete all as specified and directed by Engineer-in-Charge.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and as directed by Engineer in Charge.
Taking down rainwater pipes/PVC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clamps complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends suitable for 110 mm external dia complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) TEE suitable for 110 mm external dia complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls with PVC brackets/clamps complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) bends suitable for 75 mm external dia complete all as specified and directed by Engineer-in-Charge.
S&F PVC(SWR) tee suitable for 75 mm external dia complete all as specified and directed by Engineer-in-Charge.
S & F Stainless steel Harrison curtain rods, 19/20mm dia, including stainless steel brackets and fixing brackets as per side requiement etc including taking down old one complete all as specified and directed by Engineer-in-Charge.
M&L PCC in 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping including weathering round or chamfered and necessary form work required all as specified and directed by engineer in charge
M&L for Treatment of corroded reinforcement, Removal of loose concrete upto 20mm beyond reinfrocement and treating the exposed reinforcement with Reebaklens RR alkaline rust remover and then treat the steel with Nitozinc Primer epoxy based zinc rich anti corrosive over the steel rebarrs. The zinch rich primer shall be applied at 40 microns dry film thickness and shall have salt spray resistance of <5 mg for 96 hours as per ASTM B-117 and adhesive bond strength > 1.5 MPa as per ASTM D4541,etc,complete all as specified and directed by Engineer-in-Charge.
Dismantling asbestos cement, galvalume, fiber sheet (Plan, corrugated , semicorrugated, etc.) sheet in roof covering complete all as specified and directed by Engineer-in-Charge.
S&F Pre painted GalvaIume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge.
100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning under floors as in foundations including watering and consolidation, complete all as specified and directed by Engineer-in-Charge.
M/L Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in kerbs or mud stops, rounded or chamfered on edge including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to SI 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment over 25 mm thick leveled sand cusining etc complete all as specified and directed by Engineer-in-Charge.(Sand shall be measured and paid seperetly )
Removing demolished bldg building material including loading, unloading to a distance exc 10 km but n.exc 15 Km outside defance land complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n. exc 1.5 mtr wide & n. exc 1.5 mtr depth; for foundations, etc. n. exc. 10 sqm on plan and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material exceeding 500m but not exceeding 1.5 km and depositing where directed at al level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed by Engineer-in-Charge.
S & F RCC Class NP 2, 150 mm bore pipes laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
M&L For Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L For Plain Cement Concrete Type B2 1:2:4 (using 20 mm graded stone aggregate) in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
M&L for Precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Forming fiar finished channel n.exc 24 cm inner girth using extra cement complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes 150 mm dia bore for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, LT underground cable of size 4 core 16 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc.laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as specified and directed by Engineer-in-Charge.
S&L GI tubing light grade 40 mm bore intrenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed by Engineer-in-Charge.
Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete,(fittings Such as switches, ceiling roses, pendents, regulators sockets etc, to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 1.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one light/Fan point controlled by one,one way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No.126 mentioned here-in- before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
Switch piano, flush type single pole, one way 6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm three terminals complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in repairs complete with 2.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 2.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one 15 Amps socket outlet independent board complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin 6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F piano switch,in repairs, flush button single pole one way 16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin,6 and 16 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN 6 to 32 Amps, 240 Volts,"B" grade complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volts, 6 to 32 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with 2 runs of single core 4 Sqmm PVC insulated FRLS copper conductor cable, unsheathed LT 1100 Volts grade drawn through and including non metalic rigid concealed PVC conduit and accessories fixed on wall/roof including one run of 4 Sqmm of PVC insulated copper cable for earth continuity complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with 2 runs of single core 2.5 Sqmm PVC insulated FRLS copper conductor cable, unsheathed LT 1100 Volts grade drawn through and including non metalic rigid concealed PVC conduit and accessories fixed on wall/roof including one run of 2.5 Sqmm of PVC insulated copper cable for earth continuity complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED , Tube light fitting 20 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. >180º wide light distribution. soft glare free light complete accessories prewired and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete all as specified and directed by Engineer-in-Charge.
S&F Fresh Air fan 250 mm sweep, 240 Volt AC single phase including making hole in wall and fixing arrangements complete all as specified and directed by Engineer-in-Charge.
Supply and fix energy efficient LED flood light new Generation Energy Saving LED flood light powder coated PDC Aluminium body with toughened glass visor long life save exclusive-cast aluminium flood light fitting with high power LEDs 150 Watt as light source including necessary fixing arrarangements complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4 mm GI earth continuity conductor including 15 mm bore pipe Light grade for protection of lead by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to maint switch control board upto 7.5 mt away from earth electrode all as shown as per plate No 05 of SSR part - I including necessary earth work, PCC 1:3:6 type C1 chamber, RCC cover slab of 50 mm thick 1:2:4 with 8 mm CTD 140 mm C/C with suitable handle, watering pipe 20 mm dia light grade pipe with funnel, charcoal, salt and testing on completion and including taking old unserviceable earthing with connected items complete all as specified and directed by Engineer-in-Charge.
laxmi enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .