Loading…
Loading…
Tender Value
₹25.0 L
EMD Value
₹49,940
Closing Date
28 Jul 2026, 6:00 pm
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR MAINT OF HT DISTRIBUTION SYSTEM SERVING OF HT BREAKERS VCB AND RMUS REPLACEMENT HT UG CABLE LIGHTING ARRESTER GOD AND REPAIR OF TRANFORMERS INCLUDING MAINTENANCE OF EM INSTALLATION AT RANGE HILLS AREA UNDER GE (MH AND RH) KHADKI
2026_MES_776357_1
CWE/KKE/TOKEN- 18 OF 2026-27
Open Tender
Electrical and Maintenance Works
180 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KHADKI
₹49,940
Yes
3 Jul 2026
3 Jul 2026
31 Jul 2026
3 Jul 2026
28 Jul 2026
20 Jul 2026
3 Jul 2026 - 11 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in replacement Switch Air break Gang operated HT 22 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based 9 insulator and fitted on steel frame horizontally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete all as specified and directed by engineer-in-Charge. | 1 | Each | 27,690 | ₹27,690 |
| 2 | Supplying, installing, fixing, connecting and testing of Polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, siutable for 22 KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete all as specified and directed by engineer-in-Charge. | 1 | Each | 19,330 | ₹19,330 |
| 3 | M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 22000 Volts supply including taking down old lightning arresters complete all as specified and directed by engineer-in-Charge. | 1 | Set of three | 6,240 | ₹6,240 |
| 4 | M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 11000 Volts supply including taking down old lightning arresters complete all as specified and directed by engineer-in-Charge. | 2 | Set of three | 5,560 | ₹11,120 |
| 5 | Taking down unsv/damaged HT cable of 11KV/22 KV, of size 95 Sqmm and 120 Sqmm from the trench /pole/wall complete all as specified and directed by engineer-in-Charge.
Note:- Earth work shall be measured and paid seprately under relevent item of schedule. | 280 | RM | 30 | ₹8,400 |
| 6 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge. | 40 | RM | 2,310 | ₹92,400 |
| 7 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 120 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge. | 70 | RM | 2,600 | ₹1,82,000 |
| 8 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 300 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge. | 40 | RM | 4,530 | ₹1,81,200 |
| 9 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 11000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and directed by engineer-in-Charge. | 130 | RM | 1,720 | ₹2,23,600 |
| 10M & L for cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size and voltage grade including taking down old cable joint kit complete all as specified and directed by engineer-in-Charge. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TENDER.pdf
Tender Documents • 1.18 MB
BOQ_869381.xls
BOQ • 3.49 MB
Download all tender documents and submit your bid