| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAdmitted-Finance | ₹3.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.3 CrAdmitted-Finance | ₹3.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹3.4 CrAdmitted-Finance B B ROAD BARPETA ASSAM | BARPETA | ASSAM | 781301 | ₹3.4 Cr | L3 | Admitted-Finance |
| 4 | L4₹3.5 CrAdmitted-Finance | ₹3.5 Cr | L4 | Admitted-Finance |
| 5 | L5₹3.8 CrAdmitted-Finance | ₹3.8 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Macrocosm Builders L3 | TRICON L1 | Mrinal Saikia L4 | SAHANUR ISLAM MONDAL L5 | RAMESH KUMAR JAJODIA L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00CIVIL | ||||||||
| 2.00Part A: Boundary Wall | ||||||||
| 3.00 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). | 3,400.65 | mtr | 2,100 ₹71.4 L | 1,730 ₹58.8 L | 2,100 ₹71.4 L | 3,000 ₹1.0 Cr | 2,633.73 ₹89.6 L |
| 3.01400 mm dia piles | ||||||||
| 4.00 | Centering and shuttering including strutting, propping etc. and removal of form for | 386.5 | sqm | 280 ₹1.1 L | 300 ₹1.2 L | 200 ₹77,300 | 150 ₹57,975 | 370.07 ₹1.4 L |
| 4.01 | Foundations, footings, bases of columns, etc. for mass concrete | 1,191.87 | sqm | 300 ₹3.6 L | 400 ₹4.8 L | 500 ₹6.0 L | 150 ₹1.8 L | 253.25 ₹3.0 L |
| 4.02 | Columns, Pillars, Piers, Abutments, Posts and Struts | 142.5 | sqm | 325 ₹46,312.50 | 400 ₹57,000 | 250 ₹35,625 | 200 ₹28,500 | 661.39 ₹94,248.08 |
| 4.03Lintels, beams, plinth beams, girders, bressumers and cantilevers | ||||||||
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | 77.1 | cum | 7,200 ₹5.6 L | 7,000 ₹5.4 L | 6,000 ₹4.6 L | 8,000 ₹6.2 L | 6,167.76 ₹4.8 L |
| 5.011:3:6 (1 Cement : 3 coarse sand (zone-ill) derived fromnatural sources : 6 graded stone aggregate 20 mm nominalsize derived from natural sources) | ||||||||
Tender Value
₹4.1 Cr
EMD Value
₹8.2 L
Closing Date
8 Dec 2025, 2:00 pmClosed
HoS Engineering
IPM Section, IIT Guwahati
Construction of Boundary wall around Disang hostel including 2 gates and Security room in IITG Campus
2025_IITG_886545_1
IITG/IPM/NIT/C/2025-26/72
Open Tender
Civil Works
365 days
IIT Guwahati
Please refer tender document
2 documents required · 2 mandatory
₹5,000
Payable To IIT Guwahati
₹8.2 L
6 Jan 2026
21 Nov 2025
9 Dec 2025
21 Nov 2025
8 Dec 2025
21 Nov 2025
Amount
CIVIL
Part A: Boundary Wall
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).
400 mm dia piles
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-ill) derived fromnatural sources : 6 graded stone aggregate 20 mm nominalsize derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Half brick masonry with common burnt clay F.PS. (non modular) bricks of class designation 7.5 in foundations and plinth in :
Cement mortar 1:3 (1 cement: 3 coarse sand)
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Two or more coats on new work over an under coat of suitableshade with ordinary paint of approved brand and manufacture
PART B: Security Room
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 ofspecified diameter and length below the pile cap, to carry safe workingload not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :
400 mm dia piles
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-ill) derived fromnatural sources : 6 graded stone aggregate 20 mm nominalsize derived from natural sources)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Half brick masonry with common burnt clay F.PS. (non modular) bricks of class designation 7.5 in foundations and plinth in :
cement mortar 1:4 (1 cement: 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement: 4 coarse sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete
40 mm thick with 20 mm nominal size stone aggregate
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Upto 5 mm depth and 5 mm width
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessary screws etc. complete
Twin rubber stopper
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Two or more coats on new work over an under coat of suitableshade with ordinary paint of approved brand and manufacture
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floorsas required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- charge.
With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Providing and fixing 35 mm thick factory made laminated veneer lumberdoor shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixingwith butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of :
12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT-1, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade 1, Type - II marked.
PART C: Iron Gate
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 ofspecified diameter and length below the pile cap, to carry safe workingload not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :
400 mm dia piles
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-ill) derived fromnatural sources : 6 graded stone aggregate 20 mm nominalsize derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Two or more coats on new work over an under coat of suitableshade with ordinary paint of approved brand and manufacture
Electrical
Supply of 3C 4Sq.mm CU unarmoured cable. (Make-KEI/Havells/RR Kabel/Finolex)
Supply of 18watt batten LED tube light. (Make-CG/Philips/Havells)
Supply of 60Watt Ceiling Fan. (Make-CG/Orient)
Supply of 200Watt Flood Light. (Make-CG/Philips/Havells)
Supply of 3C 2.5Sq.mm CU unarmoured cable. (Make-KEI/Havells/RR Kabel/Finolex)
Supply and installation of SMC junction Box. (Make-Sintex)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a). Upto 35 sq. mm
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a). 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a).5/6 A switch
b).3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.
a).6 Module (200mmX75mm)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
RAMESH KUMAR JAJODIA (BID ID -3329099)
M/s Macrocosm Builders (BID ID -3329342)
Mrinal Saikia (BID ID -3327976)
SAHANUR ISLAM MONDAL (BID ID -3328666)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_931842.xls
BOQ • 0.44 MB
NIT.pdf
Tender Documents • 1.39 MB
Download all tender documents and submit your bid