Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
31 Jul 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tata Power Delhi Distribution Limited
Construction of Boundary Wall & Guard Room at CVL-III Finance Office and allied civil works
200001975
TPDDL/ENGG/ENQ/200001975/FY 26-27
Delhi
1 The bidder must have executed cumulative orders equal to 56 Lacs and one single order of at least 17 Lacs in last 5 years. Order copy/ Completion certificate shall be submitted in this regard. 2 The bidder must have all Statutory Compliance like Valid PAN, ESI registration, EPF registration, GSTN Registration. Bidder must submit the copy of all these Registration certificates. 3 The bidder should have average annual turnover of Rs.56 Lacs in last three financial years. Balance Sheet, profit and loss account statement/ CA Certificate for turn over shall be submitted along with the bid
₹5,000
₹68,000
10 Jul 2026
10 Jul 2026
31 Jul 2026
Supplier Sustainability Index Questionnaire
Vendor Name : Vendor Code : Date : Vendor Code
Parameter Category (Marks) S. No. Questions Detail Description Max Score Scoring Criteria
Marks Gain Response by BA Remark By BA
Environment (100) Carbon Footprint (20) 1 Does your organization calculate GHG emissions? Please select the suitable option (Select any one response): a) Yes, we calculate the GHG emissions and data is available since FY ….... b) No, but we have plans to start GHG inventorization from FY ….... c) No, we do not compute GHG emissions, nor we have any plans in near future to do so. 5 a) 5 b) 2 c) 0
2 Which GHG emissions your organization has computed and what is their value? Please select the suitable option (multiple responses can be selected): a) Scope-1 (Direct GHG emissions from sources owned or controlled by the organization); Emissions for FY 25: .................. b) Scope-2 (Indirect GHG emissions from the generation of purchased electricity, steam, heating, and cooling consumed by the organization) Emissions for FY 25: .................. c) Scope-3 (Indirect emissions from activities upstream and downstream of the value chain, i.e. with purchasers and suppliers) Emissions for FY 25: .................. 10 a) 4 b) 4 c) 2
3 Has your organization set targets & programs to reduce carbon footprint in its overall logistic operation? Please select the suitable option (Select any one response): a) Yes, our organization has set targets and programs to reduce carbon footprint. b) No, our organization does not have set targets and programs to reduce carbon footprint. c) Partially, our organization has some initiatives but no specific targets or programs in place. d) Unsure/ Not applicable 5 a) 5 b) 0 c) 3 d) 0
Energy Consumption and Efficiency (10) 4 How does your organization manage and optimize energy consumption? Please select the suitable option (multiple responses can be selected): a) We regularly conduct energy audits and implement energy-efficient technologies. b) We have designated energy management teams to monitor and improve energy usage. c) We actively promote energy-saving practices and provide employee training on energy conservation. d) We have implemented automated systems to track and control energy consumption. e) Our organization does not have specific measures in place to manage or optimize energy consumption. 5 a) 2 b) 1 c) 1 d) 1 e) 0
5 Does the organization monitor Stack Emissions (source specific) and/ or Ambient Air Emissions (area wide) in its premises? a) Yes, the organization regularly monitors both Stack and Ambient Air Emissions b) Yes, the organization monitors Stack Air Emissions only c) Yes, the organization monitors Ambient Air Emissions only d) No, the organization does not monitor Stack or Ambient Air Emissions 5 a) 5 b) 3 c) 3 d) 0
Waste Management/ Packaging (10) 6 What are the different categories of waste which your organization generates? Please select the suitable option (multiple responses can be selected): a) Hazardous Waste and/or Battery Waste b) Plastic Waste c) Metal Waste d) Biomedical Waste e) Municipal Soild Waste & other waste streams 5 a) 1 b) 1 c) 1 d) 1 e) 1
7 Does your organization has a process to recycle these waste categories either in-house or through external agency? a) Yes, all types of waste generated by us is recycled b) Yes, ....% of our waste goes for recycling c) We are not aware if any of our waste is recycled 2 a) 2 b) 1 c) 0
8 How does the organization incorporate packaging reduction, reuse, and recycling in its purchasing practices? Please select the suitable option (multiple responses can be selected): a) We actively seek suppliers who offer minimal packaging or sustainable packaging options b) We prioritize reusable packaging solutions when available and feasible c) We have established policies to encourage recycling of packaging materials d) Our organization does not specifically address packaging reduction, reuse, or recycling in purchasing practices 3 a) 1 b) 1 c) 1 d) 0
Water Management (15) 9 Has your organization set specific targets to reduce water consumption? a) Yes, our organization has set specific targets to reduce water consumption b) Our organization has some standalone initiatives to reduce water consumption, but no specific targets are set c) No standalone initiatives or targets are there to reduce water consumption 3 a) 3 b) 2 c) 0
10 Do you have a functional Rainwater Harvesting System at your facility? a) Yes with a capacity of …….KLD in …... sqm of catchment area b) No, but we have plans to put a RWH system by …..... c) No, we do not have any plans of putting up RWH in our premises 2 a) 2 b) 1 c) 0
11 What is the source wise consumption of water in your organization? Please select the suitable option (multiple responses can be selected): a) Underground Borewell approved by local authority; ..... KL b) Underground Borewell not approved by local authority; ..... KL c) Piped Municipal water supply; ..... KL d) Water Tanker; ...... KL e) Packaged Drinking Water; ...... KL f) Treated Waste Water; ..... KL g) Water consumption is not monitored in our organization 7 a) 1 b) 1 c) 1 d) 1 e) 1 f) 2 e) 0
12 Do you have any waste water treatment facility in your organization? a) Yes, we have waste water treatment facility of ….... KLD b) No, we do not have waste water treatment facility 3 a) 3 b) 0
Innovation for Sustainability (20) 13 How is your organization fostering innovation to address sustainability challenges? Please select the suitable option (multiple responses can be selected): a) By investing in internal R&D initiatives focused on sustainability. b) By establishing cross-functional teams dedicated to innovation in sustainability. c) By partnering with external stakeholders such as startups, research institutions, or NGOs. d) By encouraging employee-led sustainability projects and ideas. e) By participating in industry collaborations or consortia focused on sustainability innovation. f) Unsure/ Not applicable 10 a) 2 b) 2 c) 2 d) 2 e) 2 f) 0
14 Please share examples in support of the above. free text 10 5 marks of each example (mention any two examples)
Continuous Improvement (15) 15 Has your organization set specific ESG targets, and how are they monitored? a) Yes, our organization has set specific ESG targets, and they are monitored through regular performance assessments via well defined KPIs. b) Partial - While we do not have specific targets, but we monitor key parameters related to ESG. c) No, our organization has not set any specific ESG targets. 5 a) 5 b) 2 c) 0
16 How does your organization engage in continuous improvement in sustainability practices? Please select the suitable option (multiple responses can be selected): a) By conducting regular sustainability audits and assessments. b) By implementing feedback mechanisms from stakeholders on sustainability initiatives. c) By setting and reviewing sustainability goals on a regular basis. d) By participating in sustainability-focused training and education programs. e) By benchmarking against industry best practices on sustainability. f) By integrating sustainability considerations into decision-making processes. g) Other (Please specify) ________________________ 5 1 mark for each response with a maximum of 5 marks
17 Has the organization taken any initiative(s) to improve the Recyclability Ration of its products (End of Life Treatment) to reduce the impact of manufactured products on the environment and society? a) Yes [please share the details] b) No 5 a) 5 b)0
Renewable Energy (10) 18 Has your organization installed solar panels in the facility for renewable power generation? a) Yes for ….. KW b) No, but we purchase solar power from outside c) No, we do not have solar power in our energy mix 5 5 if details are provided else 0
19 Please provide the % share of solar in overall energy consumption (if response to previous question is Yes) …. %
20 Are you using Electric Vehicles in your organization setup? a) Yes, we have …... nos. of EVs deployed b) No, we do not have any EV in our setup 5 5 if details are provided else 0
21 In case response to previous question is "Yes", please share the details of EVs deployed in your organization setup with respect to type of usage etc. free text
Social (50) Labor Practices (20) 22 How does your organization ensure fair wages, working hours, and safe working conditions? Please select the suitable options (multiple responses can be selected): a) By implementing regular wage reviews and adjustments to ensure fair compensation. b) By adhering to legal regulations and industry standards regarding working hours. c) By conducting regular workplace inspections and safety audits to maintain safe working conditions. d) By providing training and education on labor rights and safety protocols to employees. e) By establishing grievance mechanisms for employees to report concerns about wages or working conditions. f) By collaborating with labor unions or worker advocacy groups to address labor-related issues. 10 a) 2 b) 2 c) 2 d) 1 e)2 f) 1 Maximum 10 marks
23 Does your organization have a presence of an Internal Review Committee and Policies to ensure the workplace is free of physical abuse, corporal punishment, physical contact with the intent to injure or intimidate, and disciplinary measures that cause physical discomfort? a) Yes, our organization has an Internal Review Committee and Policies in place to ensure the workplace is free from physical abuse and corporal punishment. b) Yes, our organization has Policies in place to ensure the workplace is free from physical abuse and corporal punishment, but there is no specific Internal Review Committee. c) No, our organization does not have specific Policies or an Internal Review Committee addressing physical abuse and corporal punishment. 5 a) 5 b) 3 c) 0
24 Can you provide information on diversity, equity, and inclusion within your workforce? a) Yes, our organization actively collects and reports data on diversity, equity, and inclusion metrics within our workforce. b) Yes, our organization has implemented initiatives and programs to promote diversity, equity, and inclusion within our workforce but does not currently collect or report data on diversity, equity, and inclusion within our workforce. c) No, our organization does not have specific initiatives or programs focused on diversity, equity, and inclusion within our workforce. 5 a) 5 b) 3 c) 0
Supply Chain Labor Standards (10) 25 How do you ensure that your suppliers adhere to fair labor practices? Please select the suitable option (multiple responses can be selected): a) By conducting regular audits or assessments of suppliers' labor practices. b) By requiring suppliers to sign agreements or contracts that include provisions for fair labor practices. c) By providing training and guidance to suppliers on fair labor standards and expectations. d) By engaging with suppliers in dialogue and collaboration to address any issues related to fair labor practices. e) By sourcing from suppliers with recognized certifications or accreditations related to fair labor practices. 5 a) 1 b) 1 c) 1 d) 1 e) 1
26 What steps are taken to address human rights issues in your supply chain? Please select the suitable option (multiple responses can be selected): a) Regular audits or assessments of suppliers' human rights practices. b) Requiring suppliers to adhere to codes of conduct or standards that include human rights provisions. c) Providing training and guidance to suppliers on human rights standards and expectations. d) Engaging with suppliers in dialogue and collaboration to address human rights issues. e) Sourcing from suppliers with recognized certifications or accreditations related to human rights practices. 5 a) 1 b) 1 c) 1 d) 1 e) 1
Community Engagement (20) 27 To promote social responsibility in its value (supply) chain, is there any visible commitment from the Top Management of the organization to integrate ESG criteria under a Responsible Supply Chain Policy/Program such as but not limited to Ethical, Social, Environmental and Gender Equality criteria, and health and safety, in its purchasing, distribution and contracting policies and practices to improve consistency with social responsibility objectives. a) Yes, there is visible commitment from Top Management to integrate ESG criteria into a Responsible Supply Chain Policy/ Program. b) Partially, there is some commitment from Top Management, but not all aspects of ESG criteria are integrated into the Responsible Supply Chain Policy/Program. c) No, there is no visible commitment from Top Management to integrate ESG criteria into a Responsible Supply Chain Policy/Program. 10 a) 10 b) 5 c) 0
28 Describe your organization's initiatives for supporting local communities where you operate. Please select the suitable option (multiple responses can be selected): a) We actively participate in community outreach programs and events. b) We contribute to local charities or nonprofits through donations or volunteer work. c) We collaborate with local stakeholders to address community needs and concerns. d) We provide employment opportunities and skill development programs for community members. e) We sponsor or support local educational or environmental initiatives. 10 a) 2 b) 2 c) 2 d) 2 e) 2
Governance (50) Ethics and Anti-Corruption (20) 29 Does the organization measure the following information:- Total number of substantiated complaints received concerning breaches of customer privacy? a) Yes, it is measured, there were ….. nos. in FY 25 b) No, it is not measured 5 a) 5 b) 0
30 Does the organization measures the following information:- Total number of identified leaks, thefts, or losses of customer data? a) Yes, it is measured, there were ….. nos. in FY 25 b) No, it is not measured 5 a) 5 b) 0
31 How does your organization prevent and address corruption risks? Please select the suitable option (multiple responses can be selected): a) By implementing robust anti-corruption policies and procedures. b) By conducting regular training on anti-corruption measures for employees. c) By establishing clear channels for reporting corruption concerns. d) By conducting periodic risk assessments to identify and mitigate corruption risks. e) By collaborating with law enforcement agencies or regulatory bodies to address corruption issues. 5 a) 1 b) 1 c) 1 d) 1 e) 1
32 Has the organization established a Code of Business Ethics, endorsed by senior management indicating organization’s values, principles, standards, and norms of behavior? a) Yes, our organization has established a Code of Business Ethics endorsed by senior management. b) No, we do not have any Code of Business Ethics endorsed by our senior management as of now, but we plan to introduce it by FY ...... c) No, we do not have any Code of Business Ethics endorsed by our senior management, nor we have any immediate plans for the same. d) Unsure/ Not applicable. 5 a) 5 b) 2 c) 0 d) 0
Transparency and Reporting (15) 33 How does your organization communicate its ESG efforts to stakeholders? Please select the suitable option (multiple responses can be selected): a) Through regular reports or publications dedicated to ESG initiatives. b) By hosting stakeholder meetings or forums specifically focused on ESG topics. c) Via dedicated sections on the company website or sustainability reports. d) Through social media platforms or other digital communication channels. e) By participating in industry conferences or events focused on sustainability. 5 a) 1 b) 1 c) 1 d) 1 e) 1
34 Is there a well-established governance structure for regulating/governing its policies? a) Yes, there is a well-established governance structure in place. b) Partially, there is some governance structure, but it's not well-established. c) No, there is no well-established governance structure in place, but we intend to establish the same by FY ..... d) No, there is no well-established governance structure in place, nor do we have any plans to establish the same in near future. 5 a) 5 b) 3 c) 1 d) 0
35 Are all labor, health, and safety policies, practices, and expectations communicated to all employees and suppliers in local or appropriate languages? a) Yes, all policies, practices, and expectations are communicated in local or appropriate languages. b) Partially, some policies, practices, and expectations are communicated in local or appropriate languages, but not all. c) No, not all policies, practices, and expectations are communicated in local or appropriate languages. 5 a) 5 b) 3 c) 0
Certifications (15) 36 Does your organization have following certifications (valid till date-please mention validity) Please select the suitable option (multiple responses can be selected): a) ISO 9001 accreditation b) ISO 20400:2017 or equivalent c) SA 8000 or equivalent d) ISO 14001 certification e) ISO 18001/45001 or equivalent f) ISO/IEC 27001 or equivalent g) Other (Please specify) ________________________ 15 a) 1 b) 5 c) 4 d) 2 e) 1 f) 1 g) 1
What is GHG emission?
GHG emission stands for Greenhouse Gas emission, which refers to the release of gases into the Earth's atmosphere that trap heat and contribute to global warming and climate change.
Key Greenhouse Gases (GHGs):
1. Carbon dioxide (CO₂) – from burning fossil fuels like coal, oil, and gas.
2. Methane (CH₄) – from agriculture (e.g., livestock), landfills, and natural gas leaks.
3. Nitrous oxide (N₂O) – from fertilizers, agricultural activities, and combustion.
4. Fluorinated gases – synthetic gases from industrial processes (e.g., HFCs, PFCs, SF₆).
🔥 Why GHG Emissions Matter:
GHGs act like a blanket around the Earth. They trap heat in the atmosphere, which leads to:
· Rising global temperatures
· Melting glaciers and rising sea levels
· More extreme weather (storms, droughts, floods)
· Disruption of ecosystems and food supply
📏 Measuring GHG Emissions:
GHG emissions are usually measured in tonnes of carbon dioxide equivalent (tCO₂e) to account for the different warming potentials of each gas.
· 1 tonne of methane (CH₄) = ~28–36 tonnes of CO₂e over 100 years
· 1 tonne of nitrous oxide (N₂O) = ~265–298 tonnes of CO₂e
📊 Types of GHG Emissions (Scopes):
Scope Description Examples
Scope 1 Direct emissions from owned/controlled sources Company vehicles, fuel combustion on-site
Scope 2 Indirect emissions from purchased energy Electricity used in buildings or factories
Scope 3 All other indirect emissions in the value chain Business travel, waste, supply chain emissions
🏭 Why Are GHG Emissions Important?
Climate Change: GHGs are the primary drivers of global warming.
Regulatory Compliance: Many countries require GHG reporting.
Sustainability Goals: Companies track emissions to reduce their carbon footprint.
Investor & Customer Pressure: Transparency and climate responsibility matter.
Scope 1 Emission:
Scope 1 emissions refer to direct greenhouse gas (GHG) emissions from sources that are owned or controlled by an organization. These include:
Sources of Scope 1 Emissions:
1. Stationary Combustion – e.g., fuel burned in boilers, furnaces, generators.
2. Mobile Combustion – e.g., fuel used in company-owned vehicles.
3. Process Emissions – e.g., emissions from chemical processes in manufacturing.
4. Fugitive Emissions – e.g., leakage from refrigerants or gas pipelines.
Scope 1 Emission Calculation Formula:
Scope 1 Emissions (tCO₂e)=∑(Fuel Quantity×Emission Factor)
Fuel Quantity is the amount of fuel used (in litres, m³, kg, etc.).
Emission Factor is a standard value indicating how much CO₂ (or CO₂e) is emitted per unit of fuel used. These values are typically provided by:
IPCC (Intergovernmental Panel on Climate Change)
National databases (e.g., US EPA, UK DEFRA, India’s CEA)
Example Calculation:
Scenario: A company uses 10,000 litres of diesel in generators annually.
Emission Factor (diesel): ~2.68 kg CO₂/litre
10,000 litres×2.68 kg CO₂/litre=26,800 kg CO₂=26.8 tCO₂
So, the Scope 1 emissions from diesel use = 26.8 tonnes CO₂e
Scope 2 Emission:
🔌 Scope 2 Emissions – What Are They?
Scope 2 emissions are indirect greenhouse gas emissions from the generation of purchased electricity, steam, heating, or cooling consumed by your organization.
Even though these emissions occur at the power plant (not on-site), they are accounted for by the buyer of the energy to reflect true carbon responsibility.
📐 Scope 2 Emission Calculation Formula
Scope 2 Emissions (tCO₂e)=Electricity Consumed(kWh)×Emission Factor (kg CO₂e/kWh)÷1000
Electricity Consumed: in kilowatt-hours (kWh)
Emission Factor: varies by country and source (coal, gas, hydro, renewables, etc.)
Conversion factor ÷ 1000 to convert kg to tonnes (tCO₂e)
📊 Example Calculation
Your organization consumes 100,000 kWh of grid electricity annually
Emission factor for your grid = 0.82 kg CO₂e/kWh (common in coal-heavy grids like India)
📌 Emission Factor References (Typical Values)*:
Region Grid Emission Factor (kg CO₂e/kWh)
India (CEA, 2023) ~0.82
USA (EPA Avg.) ~0.40
Renewable Energy ~0.0
Scope 2 GHG emission calculation:
If require want help of chatgpt for calculation:
e.g. type below sentence in chatgpt
“My factory annual electricity consumption is 12000 kwh in india. calculate scope 2 GHG emission value for me.”
It will give below reply:
Thanks! Based on your input:
Annual electricity consumption = 12,000 kWh
Location = India
Grid Emission Factor (India, CEA 2023) = 0.82 kg CO₂e/kWh
📊 Scope 2 Emissions Calculation:
Scope 2 Emissions = 12,000 kWh×0.82 kg CO₂e/kWh=9,840 kg CO₂e
9,840kg CO₂e ÷ 1000 = 9.84tonnes CO₂e (tCO₂e)
Your factory’s Scope 2 GHG emissions = 9.84 tCO₂e per year
Scope 3 Emission:
🌐 Scope 3 Emissions – What Are They?
Scope 3 emissions are all other indirect GHG emissions that occur in your value chain — both upstream (supplier side) and downstream (customer side). These do not come from owned or directly controlled sources but are a major part of your overall carbon footprint.
🔍 Examples of Scope 3 Activities:
Category Examples
Upstream Purchased goods & services, transportation, business travel, waste
Downstream Use of sold products, product disposal, downstream transport, franchises
Employee-related Commuting, leased assets
📐 How to Calculate Scope 3 Emissions
Because Scope 3 involves many sources, each category may use a different approach:
✅ General Formula:
Emissions (tCO₂e)=Activity Data×Emission Factor
· Activity Data = e.g., amount of goods purchased, km traveled, tonnes of waste
· Emission Factor = standard GHG factor for that activity (from sources like DEFRA, GHG Protocol, etc.)
📊 Example Calculation – Purchased Goods
· Your factory purchases 5 tonnes of steel per year
· Emission factor for steel production = 1.9 tCO₂e per tonne
5 tonnes×1.9 tCO₂e/tonne=9.5 tCO₂e5
You would repeat this process for each major activity under Scope 3.
✏️ To Calculate Scope 3 for Your Factory, if require you can use open source available on web & provide below detail for calculation of scope 3:
1. Purchased goods (type and quantity)
2. Waste generated (in tonnes or kg)
3. Business travel data (km, flights, etc.)
4. Employee commuting (approximate number, distance, transport type)
5. Transport of goods (inbound/outbound, km and tonnes)
6. Other relevant Scope 3 activities
🌫️ Stack and Ambient Air Emissions – Overview
In air pollution control and environmental compliance, stack emissions and ambient air emissions refer to two key concepts for monitoring and managing air quality.
🔥 1. Stack Emissions (Point Source Emissions)
These are air pollutants emitted from a fixed source, such as a chimney, furnace, or exhaust stack of a factory, boiler, or power plant.
🏭 Key Characteristics:
· Controlled and measurable
· Emitted directly into the atmosphere
· Subject to environmental regulation and pollution control norms
📋 Typical Stack Pollutants:
· Particulate Matter (PM10, PM2.5)
· Sulphur Dioxide (SO₂)
· Nitrogen Oxides (NOx)
· Carbon Monoxide (CO)
· Carbon Dioxide (CO₂)
· Volatile Organic Compounds (VOCs)
· Heavy metals (e.g., lead, mercury, cadmium)
· Dioxins and furans
🧪 Measurement Method:
· Stack monitoring is done using Continuous Emission Monitoring Systems (CEMS) or manual stack sampling as per CPCB/MoEF norms.
· Results are usually reported in mg/Nm³ or ppm.
🌍 2. Ambient Air Emissions (Ambient Air Quality)
These refer to the quality of the air in the environment outside the facility — i.e., the air people breathe in surrounding areas. These include emissions from multiple sources (industry, vehicles, construction, etc.).
📋 Key Ambient Pollutants Monitored:
· NH₃ (Ammonia)
· Benzene, Benzo(a)pyrene
🧪 Measurement Method:
· Ambient Air Quality Monitoring is done using Ambient Air Quality Monitoring Stations (AAQMS).
· Reported in µg/m³ as per National Ambient Air Quality Standards (NAAQS) in India.
✅ Regulatory Standards (India – CPCB):
Pollutant Stack Limit (Typical) Ambient Air Limit (24-hr avg, Industrial Area)
PM 150 mg/Nm³ (stack) 100 µg/m³ (PM10), 60 µg/m³ (PM2.5)
SO₂ 100 mg/Nm³ 80 µg/m³
NOx 50–300 mg/Nm³ 80 µg/m³
CO 100 mg/Nm³ 2 mg/m³ (1-hr avg)
Limits vary by industry type, fuel, and state-specific rules.
Aspect Stack Emissions Ambient Air Emissions
Source From industrial stacks or chimneys From all sources in the open environment
Purpose Regulatory compliance & pollution control Public health & environmental monitoring
Monitoring Stack analyzers or sampling Ambient air monitoring stations
ESG stands for Environmental, Social, and Governance — a framework used to assess an organization’s sustainability, ethical impact, and corporate responsibility beyond traditional financial metrics.
📊 The Three Pillars of ESG:
1. Environmental (E)
Focuses on how a company impacts the natural environment.
· Carbon footprint (GHG emissions)
· Energy and water usage
· Waste management
· Pollution control (air, water, soil)
· Biodiversity and conservation
· Climate risk and adaptation
Looks at how a company manages relationships with employees, communities, and stakeholders.
· Labor practices and human rights
· Health and safety
· Diversity, equity & inclusion (DEI)
· Community engagement
· Customer satisfaction
· Supply chain responsibility
3. Governance (G)
Relates to the structure, ethics, and accountability of corporate leadership.
· Board composition and diversity
· Business ethics and anti-corruption
· Transparency and disclosure
· Executive compensation
· Shareholder rights
· Compliance and risk management
Annexure-I Schedule of Items
Tender BOQ for "Construction of Boundary Wall & Guard Room at CVL-III Finance Office and allied civil works " (TPDDL/ENGG/ENQ/200001975/26-27)
S.No Description of Item Unit Quantity "A" Ex. Work rate (Rs.) "a" Applicable GST (in Rs.) "b" Price per Unit (in Rs.) "B"= a+b Amount (in Rs.) C=A*B HSN/SAC Code
1 Earth work in excavation for all depths in all kinds of soil by mechanical means (Hydraulic excavator) / manual means including dressing of sides and ramming of bottoms including dewatering of water coming from any source such as rains, accumulated rain water, floods, leakages from sewer, drains, water lines, ground water table being high or due to any other cause whatsoever wherever required by means of suitable capacity of pumps and pipe lines etc. or by any other method during excavation, concreting and also keeping the area dry till the construction is over including close timbering including strutting, shoring and packing cavities, soldier piling, sheet piling or by any other suitable method (wherever required) etc. complete and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. No additional payment shall be made on account of dewatering and method of shoring/piling adopted for retaining earth whatsoever. M3 250
2 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lifts. M3 181
3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 25%) M3 1
4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) M3 9
5 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum M3 45
6 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum M3 9
7 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. M2 126
8 Centering and shuttering including strutting, propping etc. and removal of form for for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts. M2 80
9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. M2 18
10 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels. Thermo-Mechanically Treated bars of grade Fe-500D or more. KG 5100
11 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) M3 10
12 Brickwork with Recycled CC Bricks of size 230x110x75 mm (M10 Grade) in foundation and plinth in :- (a) Cement Mortar 1:6 (1 cement : 6 coarse sand) M3 10
13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) M3 21
14 Brickwork with Recycled CC Bricks of size 230x110x75 mm (M10 Grade) in superstructure above plinth level upto floor V level in all shapes and sizes :- (a) Cement Mortar 1:4 (1 cement : 4 coarse sand) M3 21
15 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. KG 723
16 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture M2 50
17 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work M2 50
18 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. M3 10
19 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. KG 1547
20 Disposal of all debris/rubbish/malba/surplus excavated earth/similar unserviceable, dismantled or waste materials arising out of demolition and construction activities, by mechanical means, including loading, transporting, unloading to authorized Construction and Demolition (C&D) waste recycling plant or approved municipal dumping ground as per the directions of TPDDL Engineer-in-charge, for all leads including all lifts involved. Bidder solely shall be responsible for identifying such area and bear all costs involved, TPDDL shall not be liable for the same. Bidder shall clear the site thoroughly of such unwanted materials and rubbish etc. left out of his work and dress the site to the satisfaction of the TPDDL Engineer-in-Charge in all respects before the final handing over. Nothing additional shall be paid on account of disposal of waste material to construction and demolition (C&D) waste recycling plant. M3 10
21 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m) having 50 no rounds per 6 metre length, upto 3m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) /Spring core (2.5mm thick) wire of high tensile strength of 165 KG/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) M2 119
22 12 mm cement plaster of mix for all heights: 1:4 (1 cement: 4 fine sand) M2 187
23 15 mm cement plaster on the rough side of single or half brick wall of mix for all heights: 1:4 (1 cement: 4 fine sand) M2 187
24 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer M2 375
25 Finishing walls with readymix Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS:15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. M2 375
26 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) KG 12
27 Centering and shuttering including strutting, propping etc. and removal of form for all heights: Suspended floors, roofs, landings, balconies and access platform. M2 5
28 Providing and laying brick tiles over roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat : With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 M2 4
29 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete to achieve even shade and colour: new work (two or more coats) over and including water thinnable priming coat with cement primer having COC content less than 50g/L M2 25
30 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) M2 2
31 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. M2 4
32 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 18 mm thick. M2 1
33 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces M2 2
34 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). KG 21
35 Providing and fixing stainless steel (Grade 304) gate, grill, railing etc. made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the gate with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose weight of stainless steel members shall be considered including fixing accessories such as nuts, bolts, fasteners etc.) KG 467
Total Civil Works
Electrical Works
36 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.-Group A Point 4
37 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.-Group B Point 1
38 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required-Group C Point 1
39 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 3X 2.5 Sqmm M 30
40 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 3X 4 Sqmm M 25
41 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm M 25
42 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 50 mm M 30
43 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1-2 Module EA 1
44 Supply and fixing of 6/16 Amp switch, sockets of MK make modular type in PVC/GI box complete in all respects with testing & commissioning. EA 3
45 Supply & fixing of a set of one 6 amp switch & socket of modular type with suitable size G.I box. EA 3
46 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as requireds EA 1
47 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. EA 1
48 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, #C# curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB omplete with connections, testing and commissioning etc. as required. Single pole EA 6
49 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps EA 1
50 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door ST 1
51 Supply, laying & fixing of following sizes of Cu/GI strip/wire clamped to walls, cable trays etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories saddles, clamps etc and other fixing hardware material as required for proper installation.8 SWG G.I Wire M 30
52 4CX10sq mm Aluminium "Supply, laying, testing and commissioning of following sizes of PVC sheathed PVC insulated Aluminium conductor armoured cable 1.1 KV grade on wall, or in existing cable tray / wall /hume pipe with fixing hardware etc as required. b ) 4 core 10 Sq mm Aluminium M 50
53 Supply and making end termination with brass double compression glands and aluminium lugs for PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade of the following sizes as required:- 4 C x 10 Sq.mm ST 2
54 Providing and fixing of Fan Hook in existing Slab including cutting cement concrete and making good the same. EA 1
55 Supplying and fixing of double pole 40 /63 amps rating, 240/415 volts, #C# curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB omplete with connections, testing and commissioning etc. as required 40/63 Amp DP MCB EA 1
56 Providing fixing of 1x4 foot 48 watt LED light suitable for fixing arrangement for surface/false ceiling EA 4
Total Electrical Works
Grand Total (Civil Works + Electrical Works)
Note: Above quantities are based on Estimate and may vary in future. BoQ Items quantity has been taken as above however same shall be paid as per actuals based upon finalisation of layout dring award of works. Bidder shall quote considering all allied expenses for executing BoQ items and quantity variation. Payment shall be made as per acutals. Bidders are advised to understand the detailed scope of works and then quote their best competitive all inclusive rates. *Note: All C&D watse recycled material shall be procured from MCD approved plants only. * All sundry material/ equipment pertaining to ancillary works, retrofitting etc. as may be required for execution at site shall be considered included in the scope, even if not mentioned explicitly in the item description. No separate charges shall be payable against such requirements. * Ex Work Rate shall be total landed cost at TPDDL Site/Store inclusive of all allied expenses incurred for same.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tender 200001975._20260714132138229_Safety Bid.pdf
Tender Document • 0.31 MB
Tender 200001975._20260714132138229_TPDDL-ENGG-ENQ-200001975-FY 26-27.pdf
Tender Document • 0.79 MB
Tender 200001975._20260714132138229_Supplier Sustainability Index (SSI) Questionnaire Format.xlsx
Tender Document • 0.03 MB
Tender 200001975._20260714132138229_SSI question explanation.docx
Tender Document • 0.03 MB
Tender 200001975._20260714132138229_Annexure I BoQ Excel.xls
Tender Document • 0.06 MB
Tender 200001975._20260714132138229_Annexure I BoQ.pdf
Tender Document • 0.43 MB
Tender 200001975._20260714132138229_GCC-Service w.e.f 1 12 2020.pdf
Tender Document • 1.81 MB
Notification of Qualified Bidders_20260819165909712.pdf
Corrigendum • 0.66 MB
Notification of Qualified Bidders_20260819165909712.pdf
Corrigendum • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .