Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC 7 4 DNYANESH SOCIETY WARJE MALWALDI PUNE 411 058 | PUNE | MAHARASHTRA | 411058 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.6 L+₹2.7 L (7.88%)Rejected-Finance JAIN SADAN MAHAL ROAD SHIVPURI DISTT SHIVPURI MP | SHIVPURI | SHIVPURI | MADHYA PRADESH | L2 | Rejected-Finance High Rate | |
| 3 | L3₹37.1 L+₹3.2 L (9.36%)Rejected-Finance | L3 | Rejected-Finance High Rate |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
17 May 2022, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8301 ADDN / ALTN AND SPECIAL REPAIRS TO DEMO AREA OF COMMUNITY MEDICINE CENTRE AT AFMC UNDRE GE (CENTRAL) PUNE
2022_MES_520217_1
8301 ADDN / ALTN AND SPECIAL REPAIRS TO DEMO AREA
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Pune
As per tender documents
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹75,000
Yes
1 Jul 2022
26 Apr 2022
19 May 2022
26 Apr 2022
17 May 2022
10 May 2022
Amount
Demolition of brick work or stone/ boulders masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles and rubbish off the premises (outside of MoD land) complete all as specified and directed by Engr-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and rubbish off the premises (outside of MoD land) complete all as specified and directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engr-in-Charge.
Surface dressing n exc 15 cm deep in any type of soil complete all as specified and directed .
M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed .
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed .
M&L Cement concrete type C2 1:3:6 (using 40 mm graded) in foundations,filling and mass concrete complete all as specified and directed .
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil complete all as specified and directed .
M & L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified & directed.
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) gde D-5 and setting in CM 1:6 complete all as specified and directed .
M & L for 600 x 300 x 6 to7 mm thick, coloured glazed vitrified tiles as in skirting/dado set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick rendering in cement mortar 1:4 on stone / brick/ concrete masonry surfaces complete all as specified and directed .
M&L for 15mm thick rendering in CM 1:6 over Stone /brick / concrete wall surfaces trowelled to even & smooth w/o using extra cement for external wall surfaces complete all as specified and directed .
M&L preparation of newly plastered surfaces of wall & finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 sqm all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, in soft/loose soil returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed .
M & L for cement concrete in foundation in type C-1, 1:3:6 (using 20 mm graded aggregate) complete all as specified and directed .
S & F Rolled section / tubular section as in main and cross beam, hip and jack rafters, purlins where connect to common rafters and running rails, fixed with angle cleats or other connection plates, posts, trusses, Fe 410-W (Gde E 250) quality A including fixing of MS plates including necessary welding complete all as specified & directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet, bent to shape, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed in half round with self tapping screws as as specified . Note: Pattern (plain corrugated or manglore pattern desing) and colour as approved by GE
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed .
M & L preparation of new steel surfaces of any description , over 10 cm in width or girth , not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F powder coated anodised aluminium fixed see through cubicals , comprising of at least 63.50 x 38.10 x 1.85 mm aluminium section and including jointing cleats, aluminium snap beading 20x15mm, rubber gasket, glazing clips, 12 mm thick plain glass at sides and top fixed with rubber beading and glazing clips and all other fittings required to erect as per site requirement and as approved by Engr-in-charge complete
Dismantling posts or struts (wood, steel or R.C.C.) any section, (Posts embedded in concrete or natural ground) including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling fencing wire mesh , any type complete all as specified and directed.
Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed.
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter - flat complete all as specified and directed.
M & L Mild steel work in post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Mild steel screw bolts 5 to 10 mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
Supply only of Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 1 Km and depositing where directed
S & F Framed work Fe 410 as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings inclusive of steel sheeting or other covering, running rails and guides and hanging; also fastening and fixing with ornamental and itricate design complete all as specified and directed.
M & L granite ( of any type ) work ( table rubbed and polished ) 18 to 20 mm thick in steps, jambs, pillars, window cill , cooking platform and flooring in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite with and including screed bed or bedding layer 15 mm thick, in CM 1:6 on stone masonry surfaces complete all as specified and directed.
Demolition of stone slabs and tiles of any description of thickness in floors, aprons etc laid bedded and pointed in any mortar and rubbish off the premises (outside of MoD land) all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced and rubbish off the premises (outside of MoD land) all as specified and directed by Engr-in-Charge.
M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or bouldes complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for machine pressed precast concrete interlocking glossy finish paver block any shape and size of 60 mm thickness, M-35 grade chemically coloured laid over and including 25 mm thick stone dust including necessary formwork at edges with filling of concrete including circular cutting wherever required etc complete all as specified and directed.
M&L for precast cement concrete Kerb stone with PCC type-C-1 (1:3:6) using 20mm stone aggregates including weathering slightly rounded or chemfered angles or throating etc set in cement mortar (1:3) complete all as specified and as directed.
M & L for preparation of newly untreated concrete surfaces and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for cement concrete in foundation in type C-1, 1:3:6 (using 20 mm graded aggregate) complete all as specified and directed
ANIL CONSTRUCTION CO.
Parhar Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .