Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Being L1 |
| Sl No | Description | Qty | Unit | shoiab construction L1 |
|---|---|---|---|---|
| 1.00 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in all types of soil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc. including shoring and dewatering (if necessary) and refilling with selected excavated earth in layers of not more than 500 mm thick, each layer well rammed and consolidated including disposing the surplus earth within a distance of 200 m all as per specifications including clearing Jungle, uprooting of rank vegetation, grass, brush wood etc. complete and as directed by the Engineer-in-charge . From 0.00 to 1.50 m depth from Average Ground Level | 200 | CuM | 300 ₹60,000 Lowest |
| 2.00Lead charges for 1st 1 KM or part thereof, by mechanical transport including loading unloading, stacking / levelling etc.Note: The rates in respect of above items are applicable for NET Quantities arrived at after making deduction for voids @ 30% for Debris & @ 20% in respect of soil from corresponding TRUCK Measurement. | ||||
| 2.10 | Soil | 150 | CuM | 250 ₹37,500 Lowest |
| 2.20 | Debris | 200 | CuM | 250 ₹50,000 Lowest |
| 3.00 | Providing and laying in position cement concrete of 1:3:6/ M-10 with minimum cement content 220 Kg/Cum (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) including consolidation, finishing, curing etc. complete as per specificationsand drawings but excluding the cost of Form work shuttering, centering Complete at all levels. | 35 | CuM | 7,000 ₹2,45,000 Lowest |
| 4.00Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications. Notes: i) For all the items, of item no. 4 - in view of limit on water-cement ratio for durability requirements, concrete admixtures (Naphthalene / Melamine based superplasticizers) can be used after taking prior approval of Engineer-in-Charge and the rates quoted for these items shall be inclusive of the cost of admixtures, trial mixes, testing (at site & at approved labs), etc. complete.ii) All projections, fins etc. in the concrete surface formed at the joints in the formwork should be ground & flush and finished at no extra cost.iii) The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. | ||||
| 4.10 | up to Plinth Level | 25 | CuM | 10,000 ₹2,50,000 Lowest |
| 4.20 | In Super Structure | 10 | CuM | 10,000 ₹1,00,000 Lowest |
| 5.00 | Extra for RCC/PCC Using Ready Mix Concrete from outside project area including transporting and pumping from approved batching plants . | 45 | CuM | 1,000 ₹45,000 Lowest |
| 6.00 | Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings. Steel supplied by the contractor
"Using TMT bars of specified grades all dia. bars TMT bars to be supplied by the contractor of approved equivalent quality/ product meeting technical parameters, confirming to IS 1786. All test reports to be provided along with the supply of the materials." | 3 | MT | 90,000 ₹2,70,000 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.7 L
Closing Date
30 Jan 2026, 3:00 pmClosed
Chief Engineer
Civil Engineering Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085
Structural repair, double skin roofing, Painting of S86 and S86A Shed at South site, BARC, Trombay, Mumbai.
2026_BARC_893982_1
BARC/CED/ET/76/2025-2026 Dated 14/01/2026
Open Tender
Civil Works
Item Rate
456 days
South site, BARC, Trombay, Mumbai.
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹2.7 L
4 Jun 2026
16 Jan 2026
3 Feb 2026
16 Jan 2026
30 Jan 2026
16 Jan 2026
Lead charges for 1st 1 KM or part thereof, by mechanical transport including loading unloading, stacking / levelling etc.Note: The rates in respect of above items are applicable for NET Quantities arrived at after making deduction for voids @ 30% for Debris & @ 20% in respect of soil from corresponding TRUCK Measurement.
Debris
Providing and laying in position cement concrete of 1:3:6/ M-10 with minimum cement content 220 Kg/Cum (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) including consolidation, finishing, curing etc. complete as per specificationsand drawings but excluding the cost of Form work shuttering, centering Complete at all levels.
Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications. Notes: i) For all the items, of item no. 4 - in view of limit on water-cement ratio for durability requirements, concrete admixtures (Naphthalene / Melamine based superplasticizers) can be used after taking prior approval of Engineer-in-Charge and the rates quoted for these items shall be inclusive of the cost of admixtures, trial mixes, testing (at site & at approved labs), etc. complete.ii) All projections, fins etc. in the concrete surface formed at the joints in the formwork should be ground & flush and finished at no extra cost.iii) The minimum cement content for RCC works should be as per the latest revision of the relevant IS code.
up to Plinth Level
In Super Structure
Extra for RCC/PCC Using Ready Mix Concrete from outside project area including transporting and pumping from approved batching plants .
Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings. Steel supplied by the contractor "Using TMT bars of specified grades all dia. bars TMT bars to be supplied by the contractor of approved equivalent quality/ product meeting technical parameters, confirming to IS 1786. All test reports to be provided along with the supply of the materials."
Providing Structural steel work in M.S Plain Plates and chequrred Plates for Embedded Parts, Trench Covers, Connection plates etc.including cutting, hoisting, fixing in position and applying a priming coat of approved zinc chromate steel primer etc.including cost of structural steel Plates, welding all labour charges etc. complete as per drawings and specifications. Using materials of approved manufacturers. All test reports to be provided along with the supply of the materials.Note: 1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2) Welding weights, connections, bolts and nuts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. 3) All holes will be made by drilling only. Gas cutting of holes will not be permitted.
Providing Structural steel work using angles, channels, joists and other sections, welded and / or bolted in built up sections for trusses , structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Up to and including 300 mm Joists, 350 mm channels, and below sections Using materials of approved equivalent quality/ product meeting technical parameters, confirming to IS 2062. All test reports to be provided along with the supply of the materials. Note: 1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2) Welding weights, connections, bolts and nuts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate. 3) All holes will be made by drilling only. Gas cutting of holes will not be permitted.
Providing, supplying, cutting, welding, fabricating, hoisting and fixing in position structural steel members like trusses, purlins, posts etc. using MS hollow / circular / square / rectangular tubular sections including appling a coat of Zinc chromate primer of approved make all as per specifications, drawings and as directed by the Engineer in charge
Providing, centering, shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels
For Sub Structure
For Super Structure
Providing and constructing Half brick masonry using Flyash/ Flyash Lime bricks with minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 (using crushed sand) including scaffolding, raking out joints, curing etc. complete and with stiffners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement in Super Structure up to Floor - II level. (Reinforcement will be paid under relevant item)
Providing and constructing brickwork in cement mortar 1:6 using crushed sand with Flyash/ Flyash Lime bricks with minimum 70 kg/ Sq.cm strength of approved make and size in super structure above plinth up to and including Floor II level including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings.
Providing 12 mm thick Internal plastering in cement mortar 1:4 without cement punning (using crushed sand) finished smooth, including sieving of sand to required fineness, preparation of the surface, scaffolding, curing all as per specifications, drawings and as directed at site complete.
Providing 15 mm thick plastering using Ready mix internal plastering compound of approved make for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding complete all as per specifications and as directed at site by the Engineer-in-charge
Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge
Extra for cement punning for all types of mixes complete all as per specifications and as directed
Providing and laying (IPS Flooring) cement concrete flooring 1:2:4, using crushed sand 50 mm thick finished smooth to the required level, finishing with a floating coat of neat cement including cement slurry, providing and fixing 30 X 3 mm glass strip, curing, cleaning the surface neatly at the time of handing over the area complete as per specifications and drawings as directed by the Engineer in charge
Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting,window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-in-charge
Extra for nosing in steps of treads Using Kotah stone
Providing and fixing Glazed VITRIFIED floor tiles of approved make in different sizes conforming to IS 15622 in all colours and shades in Glossy or Matt or satin finish laid over a bed of minimum 20 mm thick bed of cement mortar 1:4 (using Crushed sand) and jointing with grey cement slurry including grouting with the joints with white cement based Tile Grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Engineer-in-charge
Using Tiles of size above 900 x 900 mm and up to 1200 x 1200 mm
Providing and Fixing Homogeneous 2.00 mm thick PVC sheet / tile in flooring and skirting of approved make in approved pattern on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer including, levelling small undulations with plasterof paris if required , rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer-in-charge in approved colour and shade
Providing and fixing 15- 17 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Telephone Black colour for kitchen platforms, vanitiy counters, Wash basin Counters, Door Frames, window sills, facias and similar locations of required size, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete as directed by the Engineer-in-charge at all levels
Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately)
Anodised Aluminium sections (Minimum anodizing thickness of 15 micron)
Extra for Colour Anodizing / Dyed anodizing on Aluminium sections & sheets
Providing and fixing Aluminium Grill 10 mm thick in natural Silver anodising of min 15 Microns with a opening size of 80 mm x 66 mm and Minimum weight of 3.13 Kg/ Sq.M including providing and fixing Suitable 'F' / 'H' section outer frame and mullion fixing with screws complete all as per specifications and as directed at site by the Engineer-in-Charge .Aluminium alloy shall be of 6063-T6 with Yield strength of minimum 6.5 kg/ sq.mm.
Providing and fixing 9 mm thick pre-laminated particle board flat pressed 3 layer or graded wood particle board conforming to IS 12823 Grade-I, Type - II in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge Prelaminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item)
With frosted glass panes of 5.00 mm thickness
Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item)
With clear float glass panes of 4.0 mm thickness
With clear float glass panes of 5.00 mm thickness
Providing and fixing approved quality and shape locks cum handle of approved make for sliding shutters
Providing and fixing approved quality stain less steel body roller wheels of approved make for sliding shutters
Providing, supplying and fixing hollow metal flush steel doors 40 mm thick of approved make consisting of door frame and shutters and all hardware fittings, frame made out of 14g thick G.I sheets and shutters made of 16g thick sheets, hollow portion filled with puff, including necessary stiffners in shutters and frame, vision panel of specified size with 4 mm glass and clip on pressed steel frame for vision panels, fixing 4 nos heavy duty stainless steel 304 grade ball bearing hinges, mortise / dead lock of approved make, a pair of 200 mm long stainless steel handles, 250 mm long stailless steel tower bolt, etc. frame hollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete, fixing in concrete with anchor fastners. finished with Polyurethane painting of approved colour complete all as per drawings and specifications and as directed by the Engineer-in-charge.
Providing and fixing aluminium aldrops of size 250 X 16 mm ISI marked anodised transparent or dyed to requried colour or shade with necessary screws, bolting from rear side complete as per specifications and as directed by the Engineer-in-charge
Providing and fixing brass mortise latch and lock of approved make with 6 levers and a pair of lever Brass handles with necessary screws etc complete suitable for fixing in wooden / steel/ FRP/ doors as per specifications.
Providing and fixing aluminium handles 175 mm long Inner grip 125 mm with 12 mm dia rod plate type BOW handles ISI marked of approved make, anodised transparent or dyed to req. colour or shade with necessary screws etc. complete.
Providing, painting and finishing walls with two coats of exterior emulusion paint of approved make on sand face plaster/ plain plaster & concrete of required shade including base coat of water proofing cement paint, preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge.
Providing, applying wall painting two coats on new work with premium plastic emulsion paint of approved brand to give an even shade without cement primer.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge.
Providing, applying wall painting two coats with Lustre paint of approved brand to give an even shade over a coat of cement primer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge
Providing and Painting two coats of synthetic enamel paint on Steel Surfaces of approved brand and manufacture to give an even shade without primer coat, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge.
Providing and fixing double tubular scaffolding system using H- frames with cup lock type on the exterior side upto seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in - charge. The elevational area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding ( Scaffolding will be paid only for Structural Repairs and related items for external faces only)
Providing and applying white cement based wall putty of approved make over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge.
Providing and Painting with Epoxy PU paint using 2 coats of (120 Micron dry film thickness) Epoxy PU coating as finishing coat over a priming coat of epoxy primer of 50 micron thickness over steel surfaces at all locations prepared and applied as per manufacturer' specifications including preparation of surface by cleaning with wire brush and rubbing, scraping , applying sand paper , making free of Rust, dust, dirt etc. filling the holes, joint, cracks if any using epoxy putty complete. all as per manufacturers technical data and as directed at site to achieve minimum overall dry Film thickness of 170 micron (50 Micron primer Coat + 120 micron finishing Coat). On STEEL surfaces
Providing and fixing lay in false ceiling of 600 x 600 mm perforated corrosion resistant Aluminium magnesium alloy metal panel fixed in 24 mm 'T' frame work of module 600 x 600 mm. Panels shall be of size 575 mm x 575 mm with perforation of 1.50 mm dia in a 3 diagonal square pattern giving 22% perforated area of approved colour in 0.70 mm thick Aluminium alloy 3105 with square edges Tiles to be stove enamelled on a continuous application for pre-treatment. The coils to be go through 4 stages of pre treatment three times of oven baked through conversion coating, priming and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability.The coils to be painted on both sides after degreasing. inside surface to have a primer of 5 microns and a coat of natural colour of 5 microns, exposed surface to have a primer of 5 microns, binder of 5 microns and a top coat of approved colour 15 microns. Grid system for fixing ceiling tiles shall comprise of tees. The 24mm main tee runers shall be suspended at an interval of 1200mm centre to centre. The 24nn cross tee runner shall be suspended at an interval of 600mm centre to centre and further supported with 24mm cross tee with inter locking arrangements to form a Grid of 600mm x 600m. The main tee shall be supported by means of 4mm G.I.rod from slab / roof. The suspension shall be provided at 1200 to 1500mm centre to centre.provision for lights, diffusers etc. to be made including extra supports wherever necessary. A non-woven felt made of glass reinforced fibre glued oner the perforation for sound absorbtion Measurements shall be as per actual area of false ceiling with out deductions for lights and diffusers.
Dismantling plain cement concrete manually / by mechanical means carefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-in-charge.
Dismantling roofing including ridges, valleys and gutter etc and stacking the material within 50 m lead. G.S Sheet / FRP Sheet / AC Sheet
Dismantling Aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplaus material and stacking of serviceable materials within 100 m lead as directed by the Engineer-in-charge
Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge.
Dismantling old plaster / skirting carefully , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 100 m lead.
Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and dispoal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge.
Dismantling doors, windows and clear storey openings (steel / wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100 m lead (full windows) Of area 3.00 Sq.M and below.
Dismantling doors, windlows and clear storey windows (steel / wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100 m lead (full windows) Of area beyond 3.00 Sq.M
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismantling and stacking within 100 m lead
Providing and fixing precoated Galvalume roofing accessories using self drilling / self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete.
Roofing accessories of Galvalume sheet up to 600 mm total width for ridges, gutters, aprons,and flashings
Supplying, fabricating, testing, transporting, handling and erecting at required positions and levels metal roofing and canopy roofing including flashings and insulation etc. as per approved drawings and design complete as directed by the Engineer-in-charge including all consumables comprising of the following: Double skin insulated standing seam roofing system comprising of 0.50 mm thick colour coated / bare Al-Zinc Alloy coated steel 0.50 mm with overall width of 400 to 500mm by seaming for 100% water tightness on outer face and 0.50 mm thick inner linear sheet with galvalume sheet profile and physical material properties as specified. These sheets shall be fixed on specially reinforced polyamide or acetylyte anti friction di electric brackets at every location for permitting unhindered, free sheet movement at all required locations. The profile shall have a special in built drainage joint at side laps to make it fully watertight even in fully submerged condition. It shall have overall depth of 100 mm from horizontal after fixing . The side laps shall be of interlocking type without requirement of any mechanical seamer. Insulation: This shall be comprising of two layers of rockwool insulation each of 50 mm thick with density of 48 kg / Cu. M. Sub Grit (Top Hat) 1.5 mm thick Glavanised steel hat section fixed to main purlins, above first layer of insulation, to support the aluminium sheets. Inner linear sheet of 0.50 mm nominal TCT of physical material properties as specified. Vapour Control layer : The vapour contol layer to reduce the movement of water vapour from inside the building through the roof construction to reduce the risk of condensation shall consists of 3 layer membrane to be laid continuous across its surface shall be fully sealed at laps, perimeters, penetrations to ensure effectiveness & aluminium foil of 0.50mm thick laid over insulation board.
Providing structural repairs in old damaged concrete structures / surfaces with approved Polymer with following operations 1) Removal of loose/Spalled or damaged concrete by chipping and cleaning the concrete surface and reinforcement steel with wire brush and with water 2) Cleaning the re bars with Acetone for complete rust removal and washing with water to make the surface clean. 3) Applying protective coat / bond coat using polymer and cement in the proportion of 1: 1.5 (1 part of polymer and 1.5 parts of cement in synthetic enamal paint like consistancy with brush) 4) Reinstate the area with polymer modified mortar in layers of maximum 20 mm with the proportion of Cement 50 Kg : washed and dried river sand 87.50 kg ; silica sand 37.50 Kg. mixed with 10 litres of Polymer (or 1 Kg cement : 1.75 kg washed and dried river sand ; 0.75 Kg silica sand : 200 ml polymer)5) If thickness of repair exceeds 20mm , after every 20 mm thick repair, bond coat as per 2 above to be applied and further thick of repair to be continued for each layer. This work is inclusive of all materials, labour, complete all as directed at site using approved polymer suitable for structural repair shall be used)Note: Scaffolding will be paid separately under relevant item
Providing and repairing to external plastering in cement mortar 1:4 (using crushed sand) of thickness 12 mm to 20 mm in patches of area up to 2.5 sq metres including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls ncluding admixtured with approved Water proofing compound @ 2% by weight of cement used and as per manufacturer's specifications ,sieving of sand to required fineness complete including disposal of rubbish to the dumping ground within 50 metres lead
Providing SFMC Micro concrete for strengthening of structural members including mixing, pouring, curing as per manufacturer specifications and as directed by the Engineer-in-charge. Using SFMC with 50% Quartz aggregate by weight (Only SFMC consumed alone will be measured for payment)
Providing, supplying, fixing in position, under floors or in walls sand cast iron pipes including required specials like bends, tees, 'Y' collars, cowl etc for soil, waste and ventilation pipes conforming to IS.1729 or Cast Iron hubless pipes confirming to IS 15905 of approved make including cost of jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site.75 mm dia sand cast iron S&S pipe as per IS:1729 with 0.90 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905
150 mm dia sand cast iron S&S pipe as per IS:1729 with 1.20 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905
Supplying, Stacking and Laying of 150 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, moorum etc. complete all as per specifications and as directed by the Engineer-in-charge
Providing & Applying polymer modified, liquid applied, crack bridging, elastic, 2 pack acrylic polymer modified cementitious water-proofing coating system on concrete /plastered wall surfaces. The waterproofing chemical shall have Tensile strength of not less than 2 N/mm2 , Elongation not less than 35%. The substrate must be prepared by suitable mechanical preparation techniques such as high pressure water jetting, needle guns, blast cleaning etc. and properly pre-wetted to a saturated surface dry (SSD) condition. Blast clean to remove all contaminants within pores /blowholes.Mixing of Mortar shall be carried out as per Manufacturers specification using slow speed paddle mixer (500- 600 rpm).Subsequently,application of mortar and Curing shall be carried out as per Manufacturer's specifications all as per the directions of the Engineer -in Charge at all levels and locations complete. Note: Scaffolding will be measured and paid under relevant item.
Providing and fixing PVC rain water pipes conforming to relevant IS type B and PVC SWR fittings & specials conforming to relevant IS including jointing with seal ring / With PVC solvent adhesive including fixing in walls using clamps etc complete all as per drawings, specifications and as directed by the Engineer-in-charge
SWR PIPE 110 mm O/D
Providing and fixing square mouth S.W. gully trap complete with CI grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design
150 x 100 mm size gully trap "P" type
Providing and constructioning Inspection chambers of Internal size clear dimention of 900 x 600 mm in 230 thick brick masonry with cement mortar 1:4 over a bed of 150 mm thick 1:4:8 cement concrete foundation, plastering with cement mortar 1:4 20 mm thick on inside, out side and all exposed sufaces finished with a floating coat of neat cement, brick corbelling at top to provide opening of 900 X 450 mm, embedding the frame and cover with CC 1:2:4 concrete, and fixing cast iron steps if necessary at 300mm intervals complete . Depth of chamber not exceeding 900 mm. (excavation, soling, cast iron cover and C.I steps will be paid separately under relevant item)
Extra depth over initial depth of 900 mm for chambers of 900 x 600 mm internal size.including fixing cast iron steps (C.I steps shall be paid under relevant item)
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top, with 230 mm brick work in cement mortar 1:4, inside and ouside & all exposed surfaces cement plaster 20 mm thick with cement mortar 1:3 finished with a foating coat of neat cement, foundation concrete of mix 1:3:6 and making necessary channel in cement concrete 1:2:4 finished with a floating coat of neat cement all complete as per standard design , fixing C.I circular manhole cover, C.I steps as per the drawing (C.I frame & cover, C.I steps and excavation work will be paid seperately under relevant Item.) For an initial depth of 910 mm
Extra depth for circular type manhole 910 mm internal dia at bottom and 569 mm Internal dia at top, in brick work. Beyond 0.91 m
Supplying and fixing Cast Iron Man hole or Cast Iron Steps cover of approved make and weight as specified in the drawings or as directed by the Engineer in charge.
Supplying and fixing CI cover 300 x 300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg
Carrying out Civil Engineering works like surveying & leveling, checking of form work fabrication, reinforcement fabrication as per drawings, witnessing sample retrieval & testing for various construction materials, ensuring concrete ingredient ratio at batching plant and pouring of appropriate grade of concrete in plain and reinforced concrete works, ensuring proper mixing of approved ingredients & waterproofing admixtures for mortars and brickwork, plaster, flooring & waterproofing works, and other civil & PH works including supervision of construction safety as per BARC specifications & relevant documentation, compiling, binding and preparation of tender documents & Agreements overall as directed by Engineer-in-Charge. Notes : (1) Each Job shall be carried out by one qualified Technician having minimum SSC with Trade certificate in Masonary/Plumber/Carpenter/Painter Trade of not less than one year duration from ITI/Government Recognised Vocational Training Institute or experienced Technician retired from Government service. (2) Deployment: The contractor shall deploy one Technician for each job as Single Day work for 6 working days per week for minimum 8 ½ hours per day with 30 minutes of break, in General (Ist / IInd) or on Round the clock shift including Saturdays, Sundays & holidays whenever necessary as per the discretion of the Engineer-in-Charge during the contract period. In case of emergency works like continuous pouring of concrete or shutdown/maintainance work, the Technician will have to stay longer occasionally as per the instruction of the Engineer in-charge. No additional payment will be made on this account. (3) Period of work: The contractor shall carry out number of Jobs per day as directed by Engineer-in -Charge. (4) Mode of measurement : Measurement will be per job basis per day. A single job shall be carried out by deploying one Technician exclusively for the particular job. (5) The Technician should be engaged after scrutiny by EIC of CED, BARC and approved by Competent authority and the deployed Technician will report to BARC Engineer/ EIC. (6) The minimum notice period before change of technician is 1 (One) month; failing which a compensation, for not providing technical support, of Rs. 1,223/- per day of shortfall in notice period will be levied on the contractor.
Retired departmental supervisor.
Any other Technician having minimum SSC or Trade certificate in Masonary/Plumber/Carpenter/Painter Trade of less than one year duration from ITI/Government Recognised Vocational Training Institute.
Carrying out Civil Engineering works like surveying & leveling, checking of formwork fabrication, reinforcement fabrication as per drawings, witnessing sample retrieval & testing for various construction materials, ensuring concrete ingredient ratio at batching plant and pouring of appropriate grade of concrete in plain and reinforced concrete works, ensuring proper mixing of approved ingredients & waterproofing admixtures for mortars and brickwork, plaster, flooring & waterproofing works, and other civil & PH works including supervision of construction safety as per BARC specifications & relevant documentation, compiling, binding and preparation of tender documents & Agreements overall as directed by Engineer-in-Charge. Note : (1)Each Job shall be carried out by one qualified Degree holder with 2 (Two ) years experience/Diploma holder with 5(Five) years experience (Licentiate in Civil/Construction Engineering / Technology) conducted by Board of Technical Examinations / University/ Autonomous Govt / Govt recognized Polytechnic/ Institute. (2)Deployment: The contractor shall deploy one Engineer for each job for minimum 26 working days per month for minimum 8 ½ hours per day with 30 minutes of break, in General (Ist / IInd) or on Round the clock shift including Saturdays, Sundays & holidays whenever necessary as per the discretion of the Engineer-in-Charge during the contract period. In case of emergency works like continuous pouring of concrete or shutdown/maintainance work, the person will have to stay longer occasionally as per the instruction of the Engineer in-charge. No additional payment will be made on this account.(3) Period of work: The contractor shall carry out number of Jobs per month as per requirement at site for the period mentioned in NIT.(4) Mode of measurement : Measurement will be per job basis. A single job shall be carried out by deploying one engineer exclusively for the particular job.(5) Engineer should be engaged after scrutiny by EIC of CED, BARC and approved by Competent authority and the deployed Engineer will report to BARC Engineer/ EIC. (6) The minimum notice period before change of engineer is 1 (one) month; failing which a compensation, for not providing technical support, of Rs. 1,579/- per day of shortfall in notice period will be levied on the contractor.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 6.08 MB
Tendernotice_2.pdf
PDF • 1.43 MB
TechnicalbidET76.xls
Tender Documents • 0.07 MB
ProformaofScheduleET76.pdf
Tender Documents • 0.27 MB
ScheduleAET76.pdf
Tender Documents • 0.22 MB
BOQ_939658.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .