Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹26.2 L+₹2.1 L (8.62%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹27.9 L+₹3.8 L (15.7%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹31.2 L+₹7.1 L (29.7%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹32.9 L+₹8.8 L (36.7%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Jul 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR TO EXTERNAL RAIN WATER DRAIN, COMMON AREAS, MISC REPAIR AND MISC E/M WORKS INCLUDING DAILY MAINTS COMPLAINTS WORK AT SANJAY VIHAR, APS COLONY, SIGNAL ENCLAVE, PRATAP CHOWK, TARURUS ENCLAVE AND ADJOINING AREAS UNDER GE (CENTRAL) DELHI CANTT-10
2023_MES_604862_1
GE/C-37/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
4 Aug 2023
22 Jun 2023
20 Jul 2023
22 Jun 2023
18 Jul 2023
6 Jul 2023
22 Jun 2023 - 6 Jul 2023
Amount
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose or disintegrated soil complete all as specified by Engineer-in-Charge .Note; Most of the Excavation will be done manually and no extra cost will be paid to contractor seperately for manual excavation. If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor.
M&L PCC 1 : 4 : 8 type D2 using 40mm graded stone aggregates as in foundation of manholes, drains, posts and in sub base etc complete all as specified by Engineer-in-Charge.
Demolition and breaking up drain pipes of 150mm dia and more (Salt glazed ware, AC or Reinforced concrete) set in cement mortar.
S&F DWCPE(SN4) 150mm diameter sewage pipes including snap fit coupler and rubber ring incl testing ,properly jointing and laying in trenches to a level bed complete all as specified by Engineer-in-Charge.
M & L for concrete (1:3:6) type C2 as in bed suitable for 150 mm bore of pipes including forming and benching cradles; complete all as specified by Engineer-in-Charge.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose/disintegrated soil or rocks complete all as specified.
Removing excavated material rocks to a distance n exc 500m and depositing where directed .
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1 : 2 : 4 type B1 finished smooth and reforming benching as required for 150 mm or 200 mm dia pipes complete all as specified.
S&F in replacement Precast plastic fibre reinforced concrete man hole covers "medium duty" of overall size 1000 mm x 500 mm x 75 to 80 mm factary made complete all as specified and directed .
Demolition of brick work built in cement mortar in any description and position, complete all as specified.
Brick work with old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified.
All as per item No 11 above but except bricks, all as specified. (Servicable bricks retrieved from Serial Item No 01 shall be used).
Taking down cement plaster in any thickness from brick or stone etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 finished even and smooth without using extra cement including water proofing compound complete all as specified by Engineer-in-Charge Note : Water proofing compound shall be measured separately under appropriate items
M & L Providing, cement concrete in roof kerbs or mud stops, coping to top of wall, rounded or chamfered on edges type C1 1:3:6 (20mm graded stone aggegate) including demolition complete all as specified and as directed.
Demolition of cement concrete to ground floor(unreinforced) and paving n.exc 15cm thickness (below or above ground level) and removing rubbish of out side MOD land.
M&L PCC 1:5:10 type E2 using 40mm Grade Stone aggregates as in foundation and sub base complete all as specified by Engr-in-Charge.
M&L Sand filling (sand cushioning) under floors or in foundation incl watering and consolidation all as spd and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment all as spd and directed.
M& L 300 x 300 mm , 22 to 25mm thick chequered cement concrete tiles, set, jointed and pointed in near cement slurry in floors including 15mm thick screed bed in floor in C M 1:6 including 25mm thick cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) including demolition of existing flooring/hardstanding all as specified and disposing to debries etc all as directed.
S&F of 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed complete to walls, ceilings or in floors with suitable clamps/bracket including taking down old pipes and necessary cutting through RCC roof and brick work etc and making good all as specified.
S&F of 110mm dia PVC (SWR) bends any radius with solvent joints, complete all as specified.
M& L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in plinth protection 75 mm thick laid in bays and surfaces finished even and fair, including filling the joints with bitumen mastic including demolition of existing surface all as specified and disposing to debries etc all as directed by Engr-in-Charge.
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Pratap chowk and adjoining area.
Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Pratap chowk and adjoining area.
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 24, 25 & 26 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician and 01 helper at Pratap Chowk Complaint cell from 0900Hrs to 1700 Hrs from Monday to Sunday. Electrician and helper shall report to complaint cell at 0900 hrs daily and get the job card for carry out the work and same will be retrun to concered JE at 1700 hrs as token of completion of job. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) All ser numbered complaint docket will be provided by contractor and amount of docket included in this. (h) Daily attendance register will be maintained by conserned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Attending to electrical complaint of no light / short circuit in light or power circuit / MCCB tripping or any other emergency nature complaint during night hours (from 09 pm to 05 am). Notes for Item No. 27 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician at Pratap Chowk Complaint cell from 2100 Hrs to 0500 Hrs from Monday to Sunday . Electrician shall report to complaint cell at 2100 hrs daily . In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) Daily attendance register will be maintained by converned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
Supply only socket piano outlet 6 Amp flush button type all as specified.
Supply only bell push single pole 6 Amps all as specified.
Supply only switch piano flush button type single pole 16 Amps.
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete.
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge.
Supply only replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed.
Supply only Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed.
Supply only ceiling rose surface PVC type with three terminals.
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed.
Supply only insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
Supply only industrial metal clad plug top, 3 pin, 10amp / 20 amp (ISI marked) as directed.
Supply only industrial metal clad socket 3 pin 10 amp / 20 amp (ISI marked) as directed.
Supply only plug top 16 Amps 3 pin 230- volts
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz,
Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting.
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and directed.
Supply only PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) .
Supply only Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked)
Supply only replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
supply only hole fastner madeup of MS 4" long with complete nut bolt all as specified.
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
Supply only thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.
Supply only replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge
Supply only liquid water proofing compound complete all as specified and directed.
Schedule of Credit
imran construction company
SHREE RAM BUILD TECH
POONAM ENTERPRISES
M/S Parmod Johar
M/S MSD & Associate
S D Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .