| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹14.3 L+₹54,543.25 (3.95%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹14.7 L+₹88,019 (6.38%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹15.2 L+₹1.4 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹15.8 L+₹2.0 L (14.2%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
18 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bamrauli
GE (AF) Bamrauli
REPAIR MAINTENACE OF VARIOUS SEWAGE INSTALLATIONS ALSO OTHER CONNECTED WORKS AT AIR FORCE STATION BAMRAULI
2021_MES_443134_1
8633/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) Bamrauli
As per Tender Documetns
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹28,000
8 Jul 2021
15 May 2021
19 Jun 2021
15 May 2021
18 Jun 2021
2 Jun 2021
60 days
Amount
Taking out aerator motor pumping set of 10 HP capacity from existing foundation after disconnecting of elect connection & necessary pipe line by opening nut bolts etc and dismantling the aerator motor pumping set for carrying out the repairs, reassembling the same including repairs worn-out nuts, bolts and washers including de-rusting, descaling, servicing, oiling, greasing ,reinstalling, testing and making good all Sewage line and electric connections to ensure proper functioning entire unit and commissioning complete all as specified and directed by Engineer-in-charge. Note :- (i) The unit rate quoted is deemed to be inclusive of the cost of nuts, bolts, washers and all material required for overhauling , de-rusting, descaling etc. (ii) Spare parts will be measured and paid separately under relevant items of this schedule.
Supply only Aerator Impeller suitable for aerator motor pumping set of capacity 10 HP.
Supply only Base Plate suitable for aerator motor pumping set of capacity 10 HP.
M&L for rewinding to aerator motor of capacity 10 HP of any make with supper enamelled copper winding wire of existing size and quantity including insulating materials ie varnish , sleeves etc including dismantling for repair and commissioning after repair complete all as specified and directed by Engineer-in-Charge.
Taking out non -clog submersible pump set of 0.37 KW capacity from existing soak well after disconnecting of necessary pipe line by opening nuts, bolts etc and dismantling the pump of any make for carrying out the repairs, reassembling the same including repairs worn-out nuts, bolts and washers etc reinstalling, testing and making good all water line and electric connections to ensure proper functioning of entire unit and commissioning complete all as specified and directed by Engineer-in-Charge. Note :- spare parts will be measured and paid separately under relevant items of this schedule.
All as per Sl Item No. 5 above but Non clog submersible pump set of 1.5 HP capacity.
All as per Sl Item No. 5 above but Non clog submersible pump set of 4 HP capacity.
All as per Sl Item No. 5 above but Non clog submersible pump set of 5 HP capacity.
All as per Sl Item No. 5 above but Non clog submersible pump set of 15 HP capacity.
M&L for rewinding of non-clog submersible pump set of 0.37 KW capacity of any make with supper enamelled copper winding wire of existing size and quantity including insulating materials ie varnish , sleeves etc complete including dismantling and commissioning after rewinding all as specified and directed by Engineer-in-Charge.
All as per Sl Item No. 10 above but Non clog submersible pump set of 1.5 HP capacity.
All as per Sl Item No. 10 above but Non clog submersible pump set of 4 HP capacity.
All as per Sl Item No. 10 above but Non clog submersible pump set of 5 HP capacity.
All as per Sl Item No. 10 above but Non clog submersible pump set of 15 HP capacity.
S&F in repairs Rotar shaft S/S suitable for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Stator motor suitable for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Impeller for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Bearing set (set of 02) for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Upper body for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Lower body for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of Oil seal chamber for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Oil seal for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Pump body for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 'O' ring set for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Rotar shaft S/S suitable for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of Stator motor suitable for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Impeller for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Bearing set (set of 02) for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Upper body for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Lower body for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Oil seal chamber for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Oil seal for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Pump body for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 'O' ring set for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Allen screw for non clog submersible motor 0.5HP/1.5HP/ 2HP/ 4HP/ 5HP complete all as specified and directed.
S&F in repairs screwed adjuster for non clog submersible motor 0.5HP/1.5HP/ 2HP/ 4HP/ 5HP complete all as specified and directed.
S&F in repairs Impeller nut cover for non clog submersible motor 0.5HP/1.5HP/ 2HP/ 4HP/ 5HP complete all as specified and directed.
S&F in repairs Hex bolts and nuts including washer for non clog submersible motor 0.5HP/1.5HP/ 2HP/ 4HP/ 5HP complete all as specified and directed.
S&F in repairs cable cap for non clog submersible motor 2HP/ 4HP/ 5HP complete all as specified and directed.
S&F in repairs upper seal for non clog submersible motor 2HP/ 4HP/ 5HP complete all as specified and directed.
S&F in repairs lower seal for non clog submersible motor 2HP/ 4HP/ 5HP complete all as specified and directed.
S&F in repairs Allen screw for non clog submersible motor 15HP complete all as specified and directed.
S&F in repairs screwed adjuster for non clog submersible motor 15HP complete all as specified and directed.
S&F in repairs Impeller nut cover for non clog submersible motor 15HP complete all as specified and directed.
S&F in repairs Hex bolts and nuts including washer for non clog submersible motor 15HP complete all as specified and directed.
S&F in repairs cable cap for non clog submersible motor 15HP complete all as specified and directed.
S&F in repairs upper seal for non clog submersible motor 15HP complete all as specified and directed.
S&F in repairs lower seal for non clog submersible motor 15HP complete all as specified and directed.
S&F in repairs Mechanical seal (set of 02) for non clog submersible motor of capacity 2 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Mechanical seal (set of 02) for non clog submersible motor of capacity 4 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Mechanical seal (set of 02) for non clog submersible motor of capacity 5 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Mechanical seal (set of 02) for non clog submersible motor of capacity 15 HP ( Make :Kishore/ Kirloskar/ KSB/ Crompton) complete all as specified and directed by Engineer-in-Charge.
M&L for Gear oil suitable for aerator motor/pumping set including removal of existing unserviceable oil complete all as specified and directed by Engineer-in-Charge. Make Veedol/Power gear/MAK
M&L for compressor oil suitable for aerator motor/ pumping set complete all as specified and directed by Engineer-in-Charge. Make Veedol/Power gear/MAK
Labour for taking out sludge from sand filter bed and transportation to depositing the existing platform , cleaning of sand filter complete inside and outside removing of unwanted vegetation in sand filter complete as directed by Engineer in charge.
Labour for taking out sludge from existing platform and transportation to deposit where directed by Engineer-in-Charge including cleaning of Platform, complete removal of unwanted vegetation in platform complete as specified and directed by Engineer- in- Charge.
Supply and laying clean dry river sand (as specified for filter bed) laid in filter bed for bedding complete all as specified directed by Engineer -in- Charge.
M&L for pumping out sewage water mixed with sludge from aeration tank containing two tanks each of size 30 Mtr x 15 Mtr x 3 Mtr deep, de-watering of sludge from the sump by the help of pump, complete all as specified and directed. Note :- For the purpose of measurement depth of contents (Water/Sludge) shall be measured not exceeding 2.5 Mtr ).
All as per Sl Item No. 58 above but from clarifier tank of 16 Mtr dia and 3 Mtr depth complete all as specified and directed.
Removing sedimented sludge (by excavating) not exceeding 75 cm deep (average) and getting out from aeration tank for removing out side of MOD and deposited where directed at a place allotted by local municipality/ municipal corporation including spreading of sufficient bleaching powder over the sludge to take all precautionary health measures complete all as specified and directed.
All as per Sl Item No. 60 above but sump well each of dia not less than 3 Mtr and average depth of excavation not exceeding 90cm complete all as specified and directed.
M&L for opening choked line of sump well upto a depth of 10mtr from ground level with necessary tools and plant to make through the sludge from one system to another complete all as specified and directed. Note: (i) The Contractor has to make his own arrangements for Tools & Plants at his own cost. (ii) The contractor shall be fully responsible for safety of the labourer engaged during the said work and necessary safety measures/equipment shall be provided to the labourer.
S&F in repairs MCCB, 415 volts, four pole of capacity 16 Amps, 16KA, ICS = 100% ICU with Thermal- Magnetic Release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections complete all as specified and directed. Make: Legrand/Siemens/Schneider/L&T/Hager/ABB
All as per Sl Item No. 63 above but 40 Amp capacity
All as per Sl Item No. 63 above but 100 Amp, 36 KA breaking capacity
S&F in repairs non clog submersible pump controller in sheet metal enclosure type MU-G6 DOL for three phase motor 415 volts, 50 HZ, 5 HP, 6-10 Amps relay range including suitable size LT panel, outdoor type, for mounting/fixing the pump controller, cubical compartmentalised of 2mm thick CRCA sheet powder coated front door openable with angle iron 45x45x5 mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 (Using 20 mm graded stone aggregate), thimbling and cable entry boxes with cable gland including painting with two coats of powder coated painting over a coat of red oxide primer complete all specified and directed. Make: Cat Part No. SS97756COVO of L&T (or) techno commercially equivalent model in Legrand/Siemens/Schneider/ABB/Hager
S&F in repairs non clog submersible pump controller in sheet metal enclosure Type MU-G20 FASD for three phase motor 415 volts, 50 HZ, 15 HP, 11KW, 9-14 Amps relay range including suitable size LT panel, outdoor type, for mounting/fixing the pump controller, cubical compartmentalised of 2mm thick CRCA sheet powder coated front door openable with angle iron 45x45x5 mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer complete all specified and directed. Make Cat Part No. SS95984DOAO of L&T (or) techno commercially equivalent model in Legrand/Siemens/Schneider/ABB/Hager
Supply and laying in repairs PVC flexible suction pipe of size 50mm dia, thickness 6mm dia with all fittings/fixtures laid in sump complete all as specified and directed. Make : Supreme / Premier / Finolex
Supply and laying in repairs PVC flexible suction pipe of size 80mm dia, thickness 6mm dia with all fitting laid in sump complete all as specified and directed. Make : Supreme / Premier / Finolex
Supply and laying in repairs Nylon rope of 24mm dia complete all as specified and directed.
M&L for cleaning, scrubbing and preparation of old painted surfaces of LT panel inside and outside including railing across at STP various locations complete and applying two coats of synthetic enamel painting over a coat of red oxide primer complete all as specified and directed.
M&L for welding LT panel i.e. door front/ rear, hinges, compartment etc and making good the existing surface after necessary work complete all as specified and directed by Engineer-in Charge. Note:- (i) Necessary electric shutdown to the panel shall be taken by the contractor before commencement of the repair/welding work. (ii) Painting work will be measured separately under relevant item.
Cleaning of installation surrounding areas i.e cutting grasses, bushes etc and making neat and clean the area complete all as specified and directed by the Engineer-in-Charge.
S&F in repairs MU1 contactor, 16A, 415V complete all as specified and directed. Make: Cat Part No. CS94007DOO of L&T (or) techno commercially equivalent model in Legrand/Siemens/Schneider/ABB/Hager
S&F in repairs MU2 relay, 13-21A complete all as specified and directed. Make: Cat Part No., SS95979OOCO of L&T (or) techno commercially equivalent model in Legrand/Siemens/Schneider/ABB/Hager
S&F in repairs LED type indicator lamp of red/blue/green colour for phase indication with and including taking down of unserviceable indicator and making all electric connection in existing panel complete all as specified and directed. Make : C&S / Converse / Salzer / Schneider/ BCH/L&T/ Siemens
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
Mohit Enterprises
M/S SATISH KUMAR
M/S SWASTIK BUILDERS
chauhan construction
M/S R S Traders
MAYANK ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .