Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹25.4 L+₹6.6 L (34.8%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹26.1 L+₹7.3 L (38.5%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
6 Aug 2021, 6:00 pmClosed
GE Chandigarh
GE Chandigarh
REPAIR AND MAINTENANCE OF SUMMER/ WINTER APPLIANCES, WIRING, LED LIGHTS INCLUDING CERTAIN WATER SUPPLY WORKS AT SECTOR 9-A AND DAD COLONY SECTOR 35-B UNDER GE CHANDIAGARH
2021_MES_456666_1
GE/CHD-38/2021-22
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
CLASS D CATEGORY b i
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹72,000
Yes
1 Oct 2021
2 Jul 2021
9 Aug 2021
2 Jul 2021
6 Aug 2021
25 Jul 2021
2 Jul 2021 - 9 Jul 2021
Amount
Taking down Ceiling fan of Sweep,1200 to 1400mm, 230 volts of any make & size from any height of the building for finding out the defects such as Capacitor, winding, bearing etc and servicing / overhauling the same, including replacing minor accessories like split pins, rubber reel, PVC sleeve, greasing, clamps, etc as required, and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer-in-charge. Note:- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-In -after shall be deemed to be included in the unit rate quoted.
Taking down Exhaust fans heavy duty of Sweep 225 to 450mm, 230 volts of any make & size from walls/ trusts for finding out the defects such as Capacitor, winding, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer-in-charge. Note:- The spares referred / mentioned here-In- after shall only be paid under supply only. Rest of the spares required for functioning of the fans is deemed to be included in the unit rate quoted. The labour element required for replacing the spares listed here-In -after shall be deemed to included in the unit rate quoted.
Taking down Wall mounted/Pedestal fans of Sweep 350 to 450mm, 230 volts of any make & size from walls/floors for finding out the defects such as Capacitor, winding, bearing etc and servicing/ overhauling the same and fixing back the same in its original position along with necessary fixing materials such as nut, bolts and washers etc all as specified and as directed by Engineer-in-charge. Note for Item Sl No 1 to 3 : (i). Cost of Bearing, Capacitor and rewinding will be measured and paid separately under the respective item of the Schedule. (ii) Labour element for removing and refixing the Bearing and removing and rewinding the winding will be measured in the respective of the schedule. (iii) Misc items such as nut & bolts, Rubber bush & locking pin etc required for satisfactory completion of job deemed to be inclusive of the unit rate.
Supply and fix of Capacitor 2.5 mfd/3.15 mfd, AC 250 volts capacity all as directed. Make :Usha / Bajaj / Tibco / CG/EPCOS
All as item No 4 here in above but of Capacity 4.0 MFD, AC 250 volts Make :- Usha / Bajaj / Tibco / CG/EPCOS
Rewinding of fan motor of any make Sweep 1200 to 1400mm and rewinding the same with single strand fine enamel copper conductor of same guage weight and turns and keeping the windings into hot air oven till the moisture evaporates including testing and commissioning complete. Make : (i) ICC (ii) DEVY DAYAL (iii) USHA Note : (1) All the misc items such as impregranted paper, warnising, cotton tape and other misc items required for satisfactory completion of job deemed to be included in the unit rate. (2) The above repairs are considered to meet the anticipated requirement if any and based on the site requirement the scope will be handed over to the Contractor.
All as item No 06 here in above but for Exhaust fan 225 to 300mm sweep.
All as item No 06 here in above but for Exhaust fan 350 to 450mm sweep.
All as item No 06 here in above but for Pedestal / Wall mounted fan upto 450mm sweep.
Supply only Ball bearing suitable for 1200mm to1400 mm sweep ceiling fans
Supply only gun metal bush suitable for 1200mm to 1400 mm sweep ceiling fans
Supply only Mild steel shaft suitable for 1200 to 1400 mm sweep ceiling fans
Supply only Ball bearing suitable for 225 to 450 mm sweep Exhaust / Wall mounting fan/Pedestal fan.
Supply only gun metal bush suitable for 225mm to 450 mm sweep Exhaust / Wall mounting fan
Supply only Mild steel shaft suitable for 225mm to 450 mm sweep Exhaust / Wall mounting fan
Supply only Rubber reel for ceiling fan any type any description.
Supply and fix in repair M.S rod including clamp , nut & split pin suitable for 1200/1400/1500mm sweep fan complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair PVC canopy suitable for 1200/1400/1500mm sweep fan complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair fan blades (set of three blades) for 1200 mm sweep and 1400 mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.
Preparation of surface and painting the Ceiling fan unit of sweep 1200 to 1400mm (consisting of Fan motor, blades, canopy and downrod) with one coat of synthetic enamel paint of existing colour and marking the MES number on the fan motor with suitable paints all as directed by the Engg-in-Charge complete. Make :- Asian / Berger / Jenson & Nicholson.
M&L for lathe work to any type of fan for taking out bush from the lower body part of Ceiling/Exhaust fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft Complete all as specified and as directed by Engineer-in-charge. Note : - Supply & fixing to Bearing shall be measured and paid separately under respective item of this Schedule.
Supply and fix in repair AC ceiling fan 1200 mm sweep with Accessories Complate with set of lades, down rod and set of canopy. Make :USHA/Crompton/Havells.
Supply and fix in repair AC Exhaust fan 250 mm sweep high air delivery low noise complete with diffusers Make : USHA/Crompton Havells.
Disconnecting and removing the unserviceable Geyser electrically operated of capacity 25 to 50 litres from its original position including disconnecting the electrical and water connections and to finding out the defects and refixing the same after making the same in serviceable condition in its original position connecting up of Electric and water connections, testing and commissioning complete all as specified and directed by Engg-in-Charge. Note : (i) Spare parts such as Inner copper container, thermostat, element, hot & cold water inter connected pipes and cord flexible will be measured and paid separatley. (ii) Misc items and brazing to the Inner copper container and welding to the outer container as required for satisfactory completion of Job deemed to be included in the unit quoted rate. (iii) Existing glass wool to be used after repairs.
S&F thermostat for Geyser 0 to 80 degrees 230 volts as suits the existing geyser of any type and capacity all as specified and directed by Engg-in-Charge. Make :- Bajaj / Racold / Venus / usha
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 27 here-in-before but 50 litre capacity.
Supply and fix in repairs Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Heating element 2 KW ISI Marked complate all as specified and as directed. MAKE:-RACOLD / VENUS / GILCO / PREMIER / THEETA
Supply and fix in repairs Safety valve
Supply and fix in repairs Indicating Lamp Round /Square
Supply and fix in repairs Gun metal non return valve ,15 mm bore
S&F for inter connected PVC flexible pipe 60 cm long with both ends check nuts suitable for hot water and connecting the same between the geyser and pipe line. Make : Pressfit/Modi/Prestolast
Supply and fix in repairs Apparatus plate for 25 litre / Syphon Assy
Supply and fix in repairs Apparatus plate for 50 litre / Syphon Assy
Supply and fix in repairs Bottom plates in two halves for 25/50 liter.
Supply and fix in repairs Plug top 3-pin, 16 Amp
Supply and fix in repairs Rubber O ring /gasket for 25 ltrs
Supply and fix in repairs Electric water storage Heater (vertical type Geysers) 25 Ltrs 230 volts, AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement .Geysers to have glass lines tank, fero glass coated container,PUF insulation, glass coated heating element, 8 BAR rated pressurer, thermostat cut off etc.including cutting holes and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Make : Havells/Venus/AO Smith
M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
S&F for replacement to unserviceable flexible PVC insulated lead in lieu of provided with new flexible PVC insulated sheathed copper conductor connection lead 3- core ,size 40/0.0076 cable suitable for geyser Complete all as specified and as directed by Engineer-in-Charge. MAKE :- HAVELL’s / FINOLEX/PLAZA/RR KABEL
Cutting chasing in bricks/walls or concrete surfaces for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
S&F for sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20Amp(C-series) as in repair complete all as specified and as directed by Engineer-in-Charge.Make :-- INDO-ASIAN / Havells/ Legrand
S&F for 15mm bore stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.Make :Kiran/Leader/Prayag
S&F for 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.Make :KIRAN/LEADER/Prayag.
Taking down to 15mm bore steel tubing and connection including cleaning for re-fixing or remove from site complete all as directed by Engineer-in-Charge.
S & F for 15mm bore steel water tubing medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors complete all as specified and directed by Engineer-in-charge. Make - JINDAL/SWASTIK/SURYAPARKASH.
Unservicable sealed compressor of water cooler of capacity 150/180liters and replaceed with new sealed compressor of existing capacity & model including soldering of liquid/gas pipe cleaning the system arresting the leaking etc complete all as specified and as directed by Engineer-in Charge. Make: Sri Ram/Tikamshah/Kirlosker. NOTE:- Recharging of refrigerant gas shall be measured & paid separately under respective item of this schedule 'A'.
All as per above item No 48 here in before but water cooler of capacity 40/80Liters.
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from water cooler of 150 litres capacity complete all as specified and as directed by Engineer-in-charge.
All as per above item No 50 hereinbefore but water cooler of capacity 40/80 liters
S&F for internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge.Make :-- KALINGA/ FINOLEX/PALAZA
Supply and fix in repairs starting relay assembly suitable for water cooler of 150 liter capacity Complete all as specified and as directed by Engineer-in-Charge . Make :-- RENUTRAL/ INDFOS/DANFOS
All as per above item No 53 hereinbefore but water cooler of capacity 40/80 liter
Supply and fix in repairs over load protector suitable for water cooler of 150 liter capacity Complete all as specified and as directed by Engineer-in-Charge. Make :-- RENUTROL/ INDFOS/DANFOS
All as per above item No 55 hereinbefore but water cooler of capacity 40/80 liter
S&F in repair fan motor suitable for water cooler of 150 liter capacity Complete all as specified and as directed by Engineer-in-Charge. Make :- COOL-HOME/ AUE
All as per above item No 57 hereinbefore but water cooler of capacity 40/80 liter
Replacement to unserviceable condenser unit with new condenser unit of existing make and model suitable for water cooler of capacity 150/180 liters, complete all as specified and as directed.
All as per above item No 59 here in before but water cooler of capacity 40/80Liters.
S& F for 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler as in repair Complete all as specified and as directed by Engineer-in-Charge.
M&L for cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces of bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine over a coat of red oxide primer Complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 62 hereinbefore but water cooler of capacity 40/80 liter
S&F for replacement to unserviceable thermo-state switch in lieu of provided with new thermo-state switch suitable for water cooler any capacity Complete all as specified and as directed by Engineer-in-Charge. Make :- RENUTROL/ INDFOS
Supply and fix in repairs sealed compressor for refrigerator of capacity 180/210 liter of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge. Make :- SHRI-RAM/ TIKAMSHAH/ KIRLOSKER / WHIRLPOOL .
Recharging of gas R-10/12/134a in refrigerant cap 180/210 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Freezer door plastic with tension spring as per existing model suitable 160/210 liter cap.
Supply and fix in repairs Door liner ( Plastic ) for upto 310 liter capacity
Supply and fix in repairs Door magnetic gasket for upto 310 litre capacity.
Supply and fix in repairs Relay box type for any cap.
Supply and fix in repairs over load protector for any Cap.
Disconnection and removing the unserviceable Split AC Outdoor & Indoor Unit/ window type of Capacity 1.5 Ton to 4 Ton from the existing position carefully for finding of the defects and to replace the unserviceable spare parts such as Compressor, Condensor Fan Motor, Condensor Coil, Suction & Discharge valves, mother plates including carry out leak detection test, Gas charging, servicing such as cleaning and removing the dust particles accumulated in the unit and filters carefully and washing the cooling unit and Indoor unit with water and refixing the same in its original position complete including connecting up of the Copper Tubes and cable connections, testing and commissioning complete all as specified and as directed by Engineer-in-charge. Make of existing ACs . Make:- LG/Blue Star/Hitachi/Voltas . (i) Cost of spares such as Compressor, Condensor Fan Motor, Condensor Coil, Suction & Discharge valves, mother plates, leak detection test, Gas charging shall be measured and paid separately under the respective Schedule 'A' Item. (ii) Makes & Specifications of the spare parts for replacement should be identical equivalent to the spares suitable for existing ACs. (NOTE :- Labour element included in Item No 80 to 98)
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 1.5 Ton Single Phase for Split Type ACs complete all as specified and as2) directed by Engineer-in-charge. Make : LG/Hitachi/Voltas/Blue Star
Supply only indoor sealed Compressor Unit of Capacity 1.5 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Outdoor hermatically sealed Compressor Unit of Capacity 2 Ton Single Phase for Split Type ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only indoor sealed Compressor Unit of Capacity 2.0 Ton Single Phase for window ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only sealed Compressor Unit of Capacity 4 Ton Single Phase for Standing Split Type ACs complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Condensor Fan Motor 230 Volt suitable for 1.5 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Condensor Fan Motor 230 Volt suitable for 2 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed. Make : LG:/Hitachi/Voltas/Blue Star
Supply only Fan Motor 230 Volt suitable for window type AC of 1.5 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blu::e Star
Supply only Fan Motor 230 Volt suitable for window type AC of 2.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Fan Motor 230 Volt suitable for Standing Split type AC of 4.0 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only blower motor suitable for Split type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only blower motor suitable for window type AC of 1.5/2 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only blower motor suitable for Standing Split type AC of 4 Ton capacity complete all as specified and as directed. Make : LG/Hitachi/Voltas/Blue Star
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit made out of Copper tubing suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit consisting of Copper tubing suitable for 2 Ton Outdoor Unit of window Type Air Conditioning complete all as directed.
Supply only Condensor Coil Unit made out of Copper tubing suitable for 4 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed.
Supply only PCB/ Mother Board Unit alongwith Remote Control Unit suitable for 1.5/2/4 Ton Indoor Unit of Split Type Air Conditioning complete all as directed.
Disconnection and Removing the unserviceable /broken Fan Blade from the Outdoor units of Split AC Unit 1.5 / 2 /4 Ton Capacity and S&F New Fan Blade Unit complete suitable for existing AC Unit.
Disconnection and Removing the unserviceable Running/Starting Capacitors from the Outdoor units of Split Type AC Unit 1.5/2/4 Ton Capacity and S&F New Capacitors of capacity 36/46/50 MFD, 230 Volts, ISI Marked.
Disconnection and removing the unserviceable Display Unit and S&F Digital Display for indicating Temperature, Temperature Sensor for 1.5/2/4 Ton Split AC Unit complete all as directed. Make :- LG/Hitachi/Voltas
Supply and Charge Refrigerant (R-22)/410a/407C Suitable for existing 1.5 Ton Capacity Split / Window type air conditioning unit complete all as directed.
Supply and Charge Refrigerant (R-22)/410a suitable for existing 2 Ton Capacity Split / Window type air conditioning unit complete all as directed.
Supply and Charge Refrigerant (R-22)/410a suitable for existing 4 Ton Capacity Standing Split type air conditioning unit complete all as directed.
Disconnection and Removing the damaged Flexible PVC Drain Pipe of dia 25mm and S&F New Standard Flexible PVC Drain Pipe of dia 25mm for capacity 1.5 ton, 2.0 ton & 4 Ton capacity.
Disconnection and removing the old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2" dia and connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as directed by Engineer-in-charge.
All as per Item No 99 here in above but of 1/4" dia
Supply only Suction Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed. (Note : Labour to element included in Item No 72)
Supply only Suction Valve made of Brass suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed. (Note : Labour to element included in Item No 72)
Supply only Suction Valve made of Brass suitable for 4 Ton Outdoor Unit of Standing Split Type Air Conditioning complete all as directed. (Note : Labour to element included in Item No 72)
Supply only Discharge Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed. (Note : Labour to element included in Item No 72)
Supply only Discharge Valve made of Brass suitable for 2 Ton Outdoor Unit of Split Type Air Conditioning complete all as directed. (Note : Labour to element included in Item No 72)
Supply only Discharge Valve made of Brass suitable for 4 Ton Outdoor Unit of Standing Split Type Air Conditioning complete all as directed. (Note : Labour to element included in Item No 72)
Disconnection and Removing the Cable connections and Copper Pipe alongwith all connected items carefully from the existing indoor and out door units and Pumpdown the refriegerant from Outdoor Unit of tonnage 1.5/2/4 Ton including stabilizer from the existing positions and shifting the AC unit at new place and refixing the outdoor and indoor units with necessary copper tubing including topping up of gas and connecting stabilzer etc for its proper functioning all as directed and specified by Engineer-in-charge.
Carry out of Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete. Note :- 1 The leakage to be observed for 24 Hours and after confirmation only the refrigerant is to be provided to the unit. 2 The cost of refrigerant will be measured and paid separately under rhe respective Schedule A Item.
Disconnection and removing the unserviceable / burnt out Copper Cable between Indoor & Outdoor Unit and S&F PVC Insulated, PVC Sheathed, Multistranded Copper Cable 3 Core 4 Sqmm, ISI Marked, 1100 volts Grade and connecting to the unit along with necessary fixing materials complete. Make: Polycab/Finolex/Havells
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, pendants, regulators sockets etc, and removing from site and making good disturbed surfaces of walls, floors etc all as directed by Engineer in Charge.
Taking down existing unserviceable MCB DB along with MCBS complete by disconnecting all as directedby Engineer in Charge.
Taking down existing unserviceable T/Light fitting any type & Capacity
Taking down existing unserviceable sub main wiring with upto 2X6Sqmm aluminum/Copper cable all as directed by Engineer in Charge.
M&L for Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of walls/ceilings or concealed etc., including provision of PVC insulated 1.5 Sqmm FRLS cable copper conductor for earth continuity and connected to common earth dolly connected including necessary MS terminal box with 3mm thicknes plastic laminated sheet cover of required size for one light point controlled by one, one way 5 Amps switch housing the switches, socket outlet etc. all as specified and as directed by Engineer in Charge.
All as per item 114.00 but for One ceiling fan/ exhaust fan point controlled by one, one way 5 Amps switch
All as per item 114.00 but for One 3 pin socket outlet 5 Amps on independent board
All as per item 114.00 but for One 3 pin socket outlet 5 Amps on same board
All as per item 114.00 but for One light point controlled by two, two way 5 Amps switches.
All as per item 114.00 but for One bell/ buzzer point controlled by one bell push on same board with other switches or on independent board.
M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and modular type metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board. MAKE : Polycab / Finolex / havells/plaza
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc., with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. MAKE : Polycab / Finolex / havells NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
All as per item No 121.00 here in above but with 2x6 Sqmm for phase and neutral and 1x4 Sqmm for earth wire complete. MAKE : Polycab / Finolex / havells/Plaza.Note for Sl No 122 to 129 : Make of PVC cables : Finolex/Polycab,Havells, Make of PVC Conduit : Mecury/Sudhaker/Avon Plast
Supply and fixing switch piano flush type single pole one way 5 Amps, 230 volts. Makes :- Anchor/SSK/Leader/Bajaj
Supply and fixing socket piano flush type universal 2 in 1,3/2 pin 5 Amps, 230 volts .Makes:-Anchor/SSK/Leader/Bajaj
Supply and fixing switch piano flush type single pole one way 15 Amps, 230 volts. Makes :- Anchor/SSK/Leader/Bajaj
Supply and Fixing socket flush type universal 2 in 1, 3/6 pin 15 Amps 230 volts. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing Ding Dong bell AC. 230 volts. Makes :- Anchor/Cona/Leader/SSK
Supply & Fixing 6 Amps 1 way one module switch complete. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing 6 Amps 2 way module switch complete. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing 16 Amps one way one module switch complete. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing 6 Amps bell push one module switch complete. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing 6 Amps two/three pin socket two module complete. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing modular multi socket outlet 16 Amps three pin socket complete. Makes :- Anchor/Cona/Leader/SSK
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete. Make : Pressfit/Modi/Prestolast
All as per Item No 136.00 here in above but of size 25mm
S&F MCB DB, SPN, 2 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, SPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, TPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, TPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, TPN, 16 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB SP 6-32 Amps 230 volts 10 KA ISI marked of Make : Legrand/L&T/ Siemens / Standard.
All as per Item No 145.00 here in above but of capacity MCB SPN 40 Amps
All as per Item No 145.00 here in above but of capacity MCB SPN 63 Amps
All as per Item No 145.00 here in above but of capacity MCB DP 63 Amps
All as per Item No 145.00 here in above but of capacity MCB TPN 63 Amps, 415 Volt.
Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed. Note for Item No 150 to 162 : Make : IndoAsian/Siemens/ Standard/Havells/Legrand
Disconnection and removing the u/s light fitting and S&F as in repair batten for LED tube light 1X18/20 watts LED, 230Volt energy saving,recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge. MAKE: Philips/Wipro/C&S/Crompton/Havells/Halonix
Supply and fixing in repair LED tube rod 18/20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 20W, complete all as specified and directed by Engineer in Charge. Make : Philips/Wipro/C&S/Crompton/Havells/Halonix .
Disconnection and removing the u/s light fitting and S&F as in repair batten for LED tube light 1X9/12 watts LED, 230Volt energy saving,recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge. MAKE: Philips/Wipro/C&S/Crompton/Havells/Halonix
Supply and fixing in repair LED tube rod 1X10watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x10W, complete all as specified and directed by Engineer in Charge. MAKE: Philips/Wipro/C&S/Crompton/Havells/Halonix
Disconnection and removing the u/s light fitting from the false ceiling carefully and S&F LED (2X2) indirect light fitting square shape 36 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. MAKE :- Philips/Wipro/C&S/Crompton/Halonix
Disconnection and removing the u/s light fitting from the Surface mounted ceiling carefully and S&F LED (2X2) indirect light fitting square shape 36Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. MAKE :- Philips/Wipro/C&S/Crompton/Halonix
Disconnection and removing the u/s light fitting from the Surface mountend carefully and S&F Surface mounted LED (1X4) Panel indirect light fitting 40Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. MAKE :- Philips/Wipro/C&S/Crompton/Halonix
S&F Ceiling mounted Slim design LED recessed round Downlight with Superior light output and internal driver 18 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. MAKE :- Philips/Wipro/C&S/Crompton/Halonix
S&F Ceiling mounted Slim design LED recessed Square Downlight with Superior light output and internal driver 18 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. MAKE :- Philips/Wipro/C&S/Crompton/Halonix
S&F Flood Slim LED light output and internal driver 150 Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed. MAKE :- Philips/Wipro/C&S/Crompton/Halonix
Supply and Fixing lamp holder,batten/angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed. Make : Anchor/Cona/Leader/Bajaj
Disconnection and removing the u/s LED lamp and S&F LED lamp 9 watts complete all as spfd and directed. MAKE : Philips/Wipro/Halonex/Crompton/Halonix
S&F decorative Post top LED 40Watt for 360* indirect light with IP 65 protection 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size complete all as specified and directed. MAKE :- Philips/Wipro/C&S/Crompton/Halonix
Supply and Fixing two way swith universal 5 Amps 230 volts. Makes :- Anchor/Cona/Leader/SSK
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
S&F Tubes 15 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified. MAKE : JINDAL, TATA, BST, PRAKASH TUBES, OSWAL.
S&F Tubes 20 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified. MAKE : JINDAL, TATA, BST, PRAKASH TUBES, OSWAL..
S&F Tubes 25 mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified. MAKE : JINDAL, TATA, BST, PRAKASH TUBES, OSWAL.
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 25 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Re-fixing old steel tubes and connections of size 20 mm bore in new or old position (walls, ceilings, floors/trenches etc.) complete all as specified. NOTE: GI tube taken down under serial item No 09 shall be fixed under this item.
Re-fixing old steel tubes and connections of size 25 mm bore in new or old position (walls, ceilings, floors/trenches etc.) complete all as specified. NOTE: GI tube taken down under serial item No 10 shall be fixed under this item.
Cutting existing 15 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Cutting existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Cutting existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Cutting existing 40mm to 50 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
DI pipe 150 mm (certifugally cast) class 'K-9' (ISI Mark) in any length with spigot and socket ends as per is 1536-2001 jointed ie rubber gasket joint and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified Make: Electro Steel/Lanco/Kesoram/Tata
DI pipe 100 mm (certifugally cast) class 'K-9' (ISI Mark) in any length with spigot and socket ends as per is 1536-2001 jointed ie rubber gasket joint and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified Make: Electro Steel/Lanco/Kesoram/Tata
S&F Rubber gasket joint for 100 mm dia pipe complete all as specified
S&F Rubber gasket joint for 150 mm dia pipe complete all as specified
Run lead joint including replacement of bolts, nuts & washers for 100mm bore CI pipe /joints, fixing and testing after completion complete all as specified .
Construction of valve pit chamber of size 1000X1000X100MM with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
Supply & fixing Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 100 mm bore pipeand fixed, in repairs, complete all as specified. MAKE : SANT, BIR, LEADER,ZOLOTO, KIRLOSKAR, KARTAR.
Supply & fixing 100 mm bore cast iron non Return valve PN-1.6 heavy duty both side flanged (ISI Marked) complete with fixing arrangement including taking down old existing NRV after disconncting from pipe line & removing from site complete all as specified and as directed. MAKE : SANT, BIR, LEADER,ZOLOTO, KIRLOSKAR, KARTAR.
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 40mm dia, in repairs, complete all as specified.MAKE: SANT,BIR, ZOLOTA, KIRLOSKAR
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm dia, IN REPAIRS, complete all as specified. MAKE: SANT,BIR, ZOLOTA, KIRLOSKAR
Supply and fix in repair Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia, IN REPAIRS, complete all as specified. MAKE: SANT,BIR, ZOLOTA, KIRLOSKAR
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 80mm to 100 bore ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) Jointing material and pipe length will be measured and paid saperately under approriate item of sch 'A' herein.
Arresting of water leakage from existing pipe line in position from GI pipe of size 40mm to 50mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note :- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Arresting of water leakage from existing pipe line in position from GI pipe of size 15mm to 25mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note :- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Locating blockage in existing distribution pipe line 25/40mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location. ( Maximum up to 3 location) including necessary cutting/threading/welding work & provision of required size of fittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified . Note :- (i) Pipe length will be measured and paid saperately under approriate item of sch 'A' (ii) Contractor shall restore supply system within 8Hrs.
Dismantling to existing unserviceable submersible pump motor of 25HP, 3Phase, 440Volt, 50HZ and Rewinding to stator with PVC insulated copper winding wire including sleeves, thimble & minor spare parts like as bronze bushes, gland packing etc and Re-assembling to the same after motor after repair work . Complete all as specified and as directed by Engineer -in - Charge.
All as per item No 194 here in before but for Submersible motor of 15 HP
All as per item No 194 here in before but for Submersible motor of 12.5 HP
Supply/repair and fix for motor bearing bush (Set of five) for Submersible pump 25HP complete all as specified and as directed .
All as per above No 197 here in before but for Submersible motor of 15 HP
All as per above No 197 here in before but for Submersible motor of 12.5 HP
Supply/repair and fix for stainless steel shaft suitable for submersible pump 25HP complete all as specified and as directed
All as per above No 200 here in before but for Submersible motor of 15 HP
All as per above No 200 here in before but for Submersible motor of 12.5 HP
Supply/repair and fix for Impeller suitable for submersible pump 25HP complate all as specified and as directed by engineer in charge.
All as per item No 203 here in before but for Submersible motor of 15 HP
All as per item No 203 here in before but for Submersible motor of 12.5 HP
Supply/repair and fix for bearing bush suitable for submersible pump 25HP complate all as specified and as directed by engineer in charge.
All as per item No 206 here in before but for Submersible motor of 15 HP
All as per item No 206 here in before but for Submersible motor of 12.5 HP
Dismantling to defective induction motor with centrifugal pump set of 50HP, strip opening, taking out old burnt winding wire from stator carefully, cleaning the stator slots carefully, Re-winding to stator with copper winding wire as per exiting size of wire including providing mica paper in stator slots thimbles, vanishing to winding wire and assembling to motor after repair work including testing to motor at work shop complete all as specified and as directed by Engineer - in - charge. NOTE :- Defective spare parts, bronze bushes etc shall be measured & paid separately but fixing charges shall be deemed to be included in the unit rate of this item. nothing extra shall be entertained on this account.
Supply/repair and fix ball bearing as per existing size for motor make: SSK/NBC/SKF
Supply/repair and fix ball bearing as per existing size for centrifugal pump set make: SSK/NBC/SKF
S&F in repair PVC insulated, unsheathed copper conductor cable 10Sq mm, 3Core, Suitable for submersible pump motor complete all as specified and as directed. Make: kalinga/finolex/plaza/havells.
Disconnection and removing the unserviceable spare kit of Power contactor 3 pole, 440 volts and supply and fix new spare kit unit suitable for MNX-32 Power contactor Cat No CS94147 of Make L&T or its equivalent in Siemens/GE
All as per item No 213 here-in-above but of capacity MNX-A2 Power contactor of Make:- L&T/Siemens/GE
Supply and Fixing relay capacity of 28 to 32Amp of Make :- L&T/Siemens/GE
Supply and Fixing sinle phase pervinter Make :- L&T/Siemens/GE
Supply and Fixing Change over switch 100Amp 3Phase, 440Volt Make :- L&T/Siemens/GE
Supply and Fixing 10KVR, 3Phase, 440Volt Make :- L&T/Siemens/GE
HRC fuse for 415 volt, 63 Amp rating HF type Make L&T/Siemens/GE
Indication Lamp set of 3 for RYB & N
M & L for Outdoor type Straight through ,jointing kit,heat shrinakable for 11KV grade UG cable 120 Sqmm 3 core Aliminium conductor complete along with jointing material all as specified and as directed .
M & L for Indoor type jointing kit heat shrinakable for 240 Sqmm 3.5 Core 1100 Volts grade LT UG cable end termination with 3.5 /4 Core Aliminium conductor complete along with jointing material all as specified and as directed
Taking down of LT XLPE/ PVC UG cable 1100 V grade, 240 Sqm 3.5 core from the trenches along with cable protection covers/bricks , sand care fully for finding out the fault and relaying the same in the trenches after Repairs in the same trenches along with the existing sand , PCC covers/Bricks complete all as directed by Engineer - in charge of the following sizes :- Note : - Excavation,RFR & PCC covers will be measured and paid seperately under the respective items Note 2:- Unserviceable LT Cable replaced with new cables will be measured and paid seperately Note3:- PCC Cover/bricks and sand protection required for addtional loops of LT cable straight through joints will be measured and paid seperately under the respective items. Note4 : - Excavation,RFR,Sand cushioning cable protection covers and joints required for additional loops and re routing of cables will be measured and paid seperately.
All as per Item No 223 here in above but of 120 sq.mm 3.5 core
All as per Item No 223 here in above but of 95 Sqmm 3.5 Core
All as per Item No 223 here in above but of 50/35/25 Sqmm 3.5 Core
Supply lay ,connect, test and commisioning of LT UG 240 Sqmm 3.5 Core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3.5/ 4 core, 1100 volts, grade of the following sizes:- Make : Havells/Polycab/Nicco/ Glostar
All as per Item No 227 here in above but of 120 sq.mm 3.5 core
All as per Item No 227 here in above but of 95 Sqmm 3.5 Core
All as per Item No 227 here in above but of 50 Sq.mm 3.5 core
All as per Item No 227 here in above but of 25 Sqmm 3.5/ 4 Core
Supply anf fix in repair LT ACB 800Amp Make :- L&T/ABB
Supply and fix in repair CT/PT 800/05 400Amp Make :- L&T/Siemens/ABB
M&L for earthing complete with galvanized steel earth plate eleteode 600mmX600mmX6mm thick buried drectly in ground Verticaly to a depath not less than 2.25mtr deep below normal ground level with top edge of earth plate at a depth of not less than 1.5mtr below normal ground level connected to galvanized iron strip 32mmX6mm by means of bolts, nuts, check nuts and washers made out of galvanized iron and GI earth strip protected by 40MM bore light grede GI Pipe as well as 20mm dia medium grade pipe 1.5mtr fixed with funnel and wire mesh as Specified and connected allas shown in electrical plate No 03 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B-1 in chamber and 40mm thick 1:2:4 type B-1 cover slab with 6mm dia mield steel bars at 100mm center to center both way with 6mm dia MS hoks Complate all as Specified and as directed.
Supply & fix Indoor Type LT panel board outdoor type double door wall mounted made out of 3mm thick CRCA sheet Steel for load bearing and 2 mm thick for non load bearing and portions mounted on frame angle iron fo suitable size weather proof/veermin proof shutter type with locking arrangment of cubical type prewired with aluminium extendable busbar 125 Amps for 03 phases and aluminium busbar 125 Amps for neutral including suitable CTs etc and powder coated paited, agle iron frame base (90CMX75CMX30CM) with provision for fixing of MCCB's mounting arrangement shall be adjustabile type,Comprising of following complete all as specified. Make of the Panel board confirming to CPRI specifications only. (i) MCCB 125 Amps, Breaking capacity 35 KA, 4 pole -1 No (In coming) Make: legrand(ii) 4Nos Aluminium Bus bar of Capacity 125 Amps for Phase & Neutral (iii) MCB SP 6-32 Amp - 40 N0s (out going) Make - legrand(iv) LED/Neon indicator bulb in RYB Colour - 1 Set.
M&L for cleaning of underground sump water storage tank of approx 12mtr dia and depth 3.3mtr by dewatring the tank by providing suction pump, scraping internal surface of tank with wire brushes and removing all scale/dirt/deposited silt, washing internal surface of tank with solution of bleaching powder and one coat of white wash to internal surface of walls complate all as specified and as directed. NOTE:- (i) Removing of honey bee hives shall be the responsibility of the contractor. no additional charges shall be admissible on this account. (ii) Contractor shall be responsible for making all safety arrangement, dewatering pump, T&P etc.
Disconnection and removing the unserviceable Solar water tank made out of stainless steel alongwith puff insulation of capacity 100 ltrs with electrical heating backup of 2 KW including taking down old U/S solar water tank. Make of existing geyser :-Kamal / BHEL / Enolar System / Solarizer/Inter Solar
Disconnection and removing the unserviceable heat exchanger along with its connected items and S&F Solar water heater collector (heat exchanger) for 100 ltrs solar water heater of same size and capacity complete connecting up of connections complete all as specified and as directed. Make :-Kamal / BHEL / Enolar System / Solarize/Inter Solar
M/S BALWINDER SINGH
GS Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .