Loading…
Loading…
Tender Value
₹2.2 Cr
EMD Value
₹2.6 L
Closing Date
9 Apr 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any Telecom work involving provision of MIS/LAN/ WAN/ Helpline /UTS/ PRS / FOIS / value added enquiry system/video enquiry system/Data connectivity/ Datacom equipment / video conferencing / wireless communication/secured communication/Wi-Fi/ Telecom work involving computer based enquiry system.
9 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure- V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
1. Tenderer must understand the work before quoting. Submission of tender shall be deemed to have been done after careful study and examination of papers as well as work site and understanding of the implication thereof. 2. Quoted rates shall include all types of taxes (including GST), duties, carrying cost of all materials for the work including loading unloading involved in the concerned work. 3. All the supply materials to be deposited at the store of SSE/Tele/Store/ASN. 4. All material supplied by Railway as well as those supplied by the contractor have to be transported from the store of SSE/Tele/Store/ASN to the site of work by the contractor's own arrangement. 5. All released materials as well as any leftover material intact will have to be transported from the site back to the office of the SSE/Tele/Store/ASN by contractor's own arrangement. 6. Any consumables which is required for execution of the work, not mentioned in this schedule as Rly. supply, contractor has to arrange for the same as per advice of Site Engineer. 7. Items supplied by the contractor will be inspected by the authorized representative of Sr. DSTE/ASN or RDSO/RITES as mentioned in schedule of work. Cost of inspection is as applicable. 8.Contractor have to submit indemnity bond for safe custody and protection of railway materials during transportation (sample may be collected from office) 9. Work to be done as per advice of site engineer.
10.The Contractor & his supervisors, staff must take proper precaution during working in Railway area to prevent any interference with existing Rly. system, working & passengers. 11. Care should be taken to avoid damage to existing gears during the work. Any damages to the Railway property shall be made good by the contractor in his own cost. 12. Payment shall be made as per extant works contract procedure based on actual work done. 13. Latest guideline of Railway Bd.'s vide letter no. 2018/CE-I/CT/9 dated 04.06.2018 regarding "Letter of Credit" as Mode of payment in Works Tenders or Service Tenders is attached in pdf file. 14. An Eastern Railway Guidelines (ER cable cut JPO) for protection of cables while digging work in the vicinity of underground Signalling, Electrical & Telecommunication cable (ER letter No.SG.224/13/0, dt.12.08.2024) has been finalised. Accordingly, while working near underground Signalling, Electrical & Telecommunication cable, proper care should be taken to avoid the cable cut, other wise the penalty amount as per Railway Guidelines will be recovered from the erring contractors. 15) PVC clause shall be applicable only in tender having advertised value above Rs.2 Crore vide Railway Bd,s letter no. 2022/CEI/ CT/GCC-2022/Policy, dated 14.07.2022.
Asansol Division: Replacement of overaged SCADA system in UDL-SNT and UDL- STN (via BBI Section) and alongwith implementaion of Cyber security in Asansol Division.
47-SDSTE-ASN-2025-26
47-SDSTE-ASN-2025-26
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹2.6 L
9 Apr 2026
17 Mar 2026
26 Mar 2026
97 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,20,48,404.95 | ||
| — | 45.00 | — | — | ||
| Supply of Optic Fibre Cable 6 Core(Single mode) armoured, as per TEC Spec. TEC/GR/OFC-02/03.Sep.2003 or latest, Make: Uniflex/Usha martin/Birla ericson optical ltd./similar. Inspection: Rites. | — | — | — | 18,74,160 | |
| — | 45.00 | — | — | ||
| Excavation of trench in all kinds of soil (1.2 mtr. Depth 300 mm width) and refilling of the trench without Bricks and final back filling, ramming and consolidation of soil as well as the disposal of the soil, if any. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately. Note: Payment will be made as per actual work done on pro-rata basis, if the required depth is not available at site. If the depth of trench is not uniform in a span of 100 mtr. of shorter lengths along the cable run, minimum depth will be taken for that particular stretch for payment. Prior permission should be taken before laying of cable if the depth of trenching is less than 1.0 Mtr. Inspection: Consignee. | — | — | — | 60,65,795.25 | |
| — | 45.00 | — | — | ||
| Supply of PLB-HDPE Duct for UG armoured Optical Fibre Cable diameter 40.0 mm, as per RDSO Specification No. RDSO/SPN/TC/45/2013 Revision 2.0 or latest, in length of 1000mtrs/roll. For each K.M. of HDPE duct pipe following items are to be supplied (a) end plugs-02nos., (b) cable sealing plugs-02nos., (c) plastic couplers slip fit/push fit type-02nos., (d) end plugs to be provided along with drum-02nos. MAKE: WESTERN/Gangotri/similar. Note: OFC being laid for any other applications like SCADA for switching stations, HDPE Ducts of other Colours shall be used like PINK/VIOLET, GREEN as per Technical Circular-124-A" (Modified)-attached, Inspection: Consignee | — | — | — | 28,29,015 | |
| — | 45.00 | — | — | ||
| Laying Of HDPE DUCT 40/33 mm in trenchs and protective works including pulling of single mode armoured OFC Cable( fibre) through duct in trenches as advised by site engineer. Note: (1)Contractor will take over the OFC cable from Railway store to site of work duly checked the continuity of each fiber from end to end (2) before & after cable laying of OFC cable through duct, continuity test from end to end of each fiber to be made by contractor to ensure availability of all fibers duly certified by the site enginner. | — | — | — | 11,13,030 | |
| — | 45.00 | — | — | ||
| Supply of Splice Closure for Optical Fiber Cables Armoured and Metal free type OFC With screws sealing as per as per TEC/GR/TX/OJC-002/03/APR-2010, including all miscellaneous items & consumables for fiber splicing, Optical fibre joint/splice enclosure shall be compatible with the type of optical fibre cable 6 Core. make: 3M/Comscope/R&M/Drone Edge/similar, Inspection: Consignee. | — | — | — | 1,60,110 | |
| — | 80.00 | — | — | ||
| Jointing, terminating and Splicing of 6 Fibre Optical Fibre Cable and fixing of termination Box/FDF/Placing of joint clousers in pit required at various location including tranportation of all the jointing & terminating materials from railway store to the works site and returning leftover materials to the railway store. The rate should include all jointing materials. | — | — | — | 2,32,695.2 | |
| — | 500.00 | — | — | ||
| Supply of GI pipe with threaded coller of 50mm nominal dia. (3.6mm thickness) as per IS Spec. No.IS:1239 Part-I: 2004, medium grade, perforated of required length. This includes supply of all materials required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges & sudden bends. Inspection: Consignee. | — | — | — | 2,02,000 | |
| — | 500.00 | — | — | ||
| Fixing of GI Pipe of required length at all road crossing/track crossing which fall on cable route & laying of telecom cable through them & also on bridge/below mettaled road/L- Xing/culvert/track crossing for laying of cable through it. This also includes installation of all materials required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges & sudden bends. | — | — | — | 49,000 | |
| — | 30.00 | — | — | ||
| Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x 1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the tenderer. | — | — | — | 2,00,220 | |
| — | 50.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as: - Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. | — | — | — | 1,79,800 | |
| — | 500.00 | — | — | ||
| Boring under Metalled Road/Railway track for crossing of Telecom cables.Boring to be done for crossing road/rail at 1 mtr depth & after boring min. 2" dia G.I pipes are to be inserted & cable to be laid through the pipes. | — | — | — | 3,53,950 | |
| — | 20.00 | — | — | ||
| Supply of POWERIDE PDU 6AMP - 4, 1.5 Metre cable with Extension, made of MS- CRCA material, No. of 6 Amp Switches: 4, No. of Sockets - 5 Pin 6 Amp: 4, ISI Marked switch, Conformity of Switches to IS:3854/1997, MAKE: POWERIDE/Similar, Inspection: Consignee. | — | — | — | 28,182.8 | |
| — | 18.00 | — | — | ||
| Supply of Earth Electrodes mild steel galvanized , light class , as per Specification No. IS:1239(Part-I)-1979 and as per PCSTE/ER's Drg. No. SI/TYP/0097 dated 25.03.25. Earth electrode pipe should be 3 mm thick, 50 mm dia. and perforated ( staggered) with 5 mm dia holes 2 nos. per 305 mm length alongwith supply of CI threaded cap, nuts, bolts, other materials as mentioned in Drg. No. SI/TYP/0097 . Earth electrode pipe to be galvanised after drilling and fabrication. Inspection: Consignee. | — | — | — | 26,928 | |
| — | 18.00 | — | — | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or cable for apparatus cases, signal post & other equipment as per guideline mentioned in PCSTE/ER'S DRG. NO. SI/TYP/0097 with provision of alternate layers of charcoal /coal and salt . Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. As per requirement MS flat may be joined by welding to increase length or to be cut & drill hole to shorten the length. All hardware and other miscellaneous materials required for installation to be supplied by the contractor | — | — | — | 20,898 | |
| — | 900.00 | — | — | ||
| Supply, Transportation at site and Installation of RCC cable route marker engraved and painted with Yellow color on both side along the route at every 30 meter and at route diversion. The cable marker shall be as per ER Drg No.S.I.-S&T/1/2024 Vide ER Technical Circular: 108 (attached) or latest. The fixing work is to be done as per extant practice of E. Rly. and as per Railway site supervisor. Inspection: Consignee. | — | — | — | 3,75,300 | |
| — | 250.00 | — | — | ||
| Excavation,trenching and earth work for Road crossing and Repair of pacca road to original state after cable laying work. Depth of trench should not be less than 1 mtr. This work to be done as per instruction of Rly. Site engineer. All materials (except cable, GI Pipe) required for the execution of the work shall be supplied by the contractor. Note: If required depth can not be achieved at particular location, then alternative location to be selected as per instruction of Rly. site engineer | — | — | — | 97,345 | |
| — | 300.00 | — | — | ||
| Excavation of trench(1.0 mtr. depth from bottom of rail), earth work and re- instatement of track while track crossing for laying of cables. This work to be done as per instruction of Rly. Site engineer. All materials (except cable, GI Pipe) required for the execution of the work shall be supplied by the contractor. Note: If required depth can not be achieved at particular location, then alternative location to be selected as per instruction of Rly. site engineer | — | — | — | 40,158 | |
| — | 300.00 | — | — | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of two (02) nos. Of 40mm HDPE pipes & two (02) nos. 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts 40mm & 50mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer. | — | — | — | 5,27,400 | |
| — | 25.00 | — | — | ||
| Supply of Fiber Distribution Management System 6 port, Single Mode, Simplex Fiber Optic Patch Panels, 19 inch 1 U Rack Mountable with SC connector with all accessories , make: Drone Edge/Syrotech/similar, Model: SY-LIU-6F 6 Port, Rack Mount LIU/ DRON EDGE 1224SLD/similar Inspection: Consignee. | — | — | — | 1,94,280.75 | |
| — | 25.00 | — | — | ||
| Supply LC-SC-10 MTR PATCH CORD ARMOURED SIMPLEX, Cable Diameter: simplex : 3.8mm, Outer Jacket: PVC or LSZH, Ferrule Type: Ceramic, Connector Retention: 100N, Armoured Flexible Tube Material: Stainless, Inner Diameter: 0.9mm,Tensile Strength : less than or equal to 147 N, Min. Bend Radius : greater than or equal to 40 ± 5vv, Pressure Resistance: less than or equal to 2450/50 N , Inspection: Consignee. | — | — | — | 23,010 | |
| — | 25.00 | — | — | ||
| Supply of SC-SC-10 MTR PATCH CORD ARMOURED SIMPLEX, Cable Diameter: simplex : 3.8mm, Outer Jacket: PVC or LSZH, Ferrule Type: Ceramic, Connector Retention: 100N, Armoured Flexible Tube Material: Stainless, Inner Diameter: 0.9mm, Tensile Strength : less than or equal to 147 N, Min. Bend Radius : greater than or equal to 40 ± 5vv, Pressure Resistance: less than or equal to 2450/50 N , Inspection: Consignee. | — | — | — | 19,470 | |
| — | 25.00 | — | — | ||
| Supply of fire retardant Simplex Fiber Optic Patch Cord LC - LC (up to 03 mtr length), Connector Insertion loss, Max.0.3dB, Sheath material: PVC, Fiber type: Single Mode 9/125 micron, Make: Dlink/Molex/Digisol/AMP/Syntimax /similar. Inspection: Consignee. | — | — | — | 7,749 | |
| — | 3050.00 | — | — | ||
| Supply of CAT6 U/UTP Cable for Indoor use, 4-pair unshielded twisted pair (UTP) cable, FR PVC Jacket, High Density Polyethylene insulation, 23 AWG solid copper conductor for superior conductivity, Conductor diameter: 0.57 mm (23 AWG), supports Gigabit Ethernet (1000 Base-T) standard, Make -Molex/DLINK/similar, Inspection: Consignee. | — | — | — | 57,950 | |
| — | 22.00 | — | — | ||
| Supply of RSTP OPTICAL MODEM 4PORT, 48V/110V, with rapid spanning tree protocol & loop free topology for ethernet network, Detailed specification attached as per annexure A, make: Team Engineers/similar, Inspection: RITES. | — | — | — | 8,58,000 | |
| — | 22.00 | — | — | ||
| Supply of RSTP LAN EXTENDER 4PORT, 48V/110V , Detailed specification attached as per annexure A, make: Team Engineers/similar, Model: Teamlink 3002ILE/similar. Inspection: RITES. | — | — | — | 8,36,000 | |
| — | 20.00 | — | — | ||
| Supply of E1 to Ethernet converter, 48V power supply, Detailed specification attached as per annexure A, make: Team Engineers/similar, model: TEAMLINK3101 IETH-E1/similar. Inspection: RITES. | — | — | — | 9,03,078 | |
| — | 15.00 | — | — | ||
| Supply & Installation of 8 port POE Switch, Number of Ports: Eight 10/100/1000 Mbps ports (4 PoE enabled Port) ports, Switching Capacity: 16Gbps, Standards: IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, ANSI/IEEE 802.3 NWay Auto-negotiation, IEEE 802.3x Flow Control, PoE Features: Supporting IEEE 802.3af, Supplie power to PD: up to 15.4Watts, Total PoE budget: 52Watts, Data Transfer Rates: Ethernet- 10 Mbps (half duplex), 20 Mbps (full duplex), Fast Ethernet- 100 Mbps (half duplex), 200 Mbps (full duplex), Gigabit Ethernet- 2000 Mbps (full duplex), LED Indicators for Link/Activity/Speed/PoE Status/Power/PoE Max, Power Adapter: AC input: 100 to 240VAC, 50/60 Hz, DC output: DC 48V/1.25 A (60Watts), Media Interface Exchange: Auto MIDI/MDIX adjustment for all parts, make: Dlink/similar, model: DGS-1008P/similar. Inspection: Consignee. | — | — | — | 2,22,263.7 | |
| — | 2000.00 | — | — | ||
| Running, laying of power cable/data cable/cat-6 cable through pvc pipes as per site engineer's instruction. All fixing material to be arranged by contractor. | — | — | — | 11,660 | |
| — | 2000.00 | — | — | ||
| Supply of flame retardent PVC conduit pipe (lSl Mark), 25mmx1.5mm, This includes all required fixing materials such as screws, nut & bolts, washers,clamps, elbow, Tee, etc make: Anchor/AKG/Precision/Polycab/similar. Inspection: Consignee. | — | — | — | 76,600 | |
| — | 5.00 | — | — | ||
| Supply of 12 mm Diameter Wire Fastener Circle Cable Clips with Metal Nail. Set of 100 Nos. make: Hiplast/Hi tech/similar. Inspection: Consignee. | — | — | — | 1,742.55 | |
| — | 500.00 | — | — | ||
| Supply of self Adhesive electrical insulation tape, size: 1.8 c.m x 6.5 m x 0.125 mm , make: steelgrip/similar. Inspection: Consignee. | — | — | — | 4,980 | |
| — | 15.00 | — | — | ||
| Supply of 10 pair/0.63 mm Copper Conductor Dia, Armoured Polythene insulated polythene sheathed jelly filled telephone cable with poly-al moisture barrier, as Per Spec. No. IRS-TC- 41/97 with Latest Amd. No. 3 or Latest. Inspection: RITES. | — | — | — | 22,98,072.45 | |
| — | 15.00 | — | — | ||
| Laying of Telecom cable including meggering of all laid cable as per instruction of site engineer. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee. | — | — | — | 1,57,075.95 | |
| — | 30.00 | — | — | ||
| Supply of 6-Quad Cable termination box (drawing attached) with wago terminal (Two in-put & Two out-put), separater & stoppers suitable for minimum 4nos. of 6 quad cable termination with door locking arrangement to terminate 4Nos. of quad cable for telecom & signal circuits (size- {lxbxh}: 3' X 1.5' X 3'). 8nos. Cable entry/exit holes of dia. 40mm each as per drawing attached with edge protection rubber grommets. Wall mounting brackets/Screws for wall mounting enclosure at rear side. 1 no. side door with secure lock. Material: MS Sheet, Thickness: 2mm, Powder coated finish. There should be provision for 4nos. Quad cable entry & 4nos. Quad cable exit as per drawing. cable armour earthing is to be done before/below cable termination box. space between 2 Wago termination hinged on DIN Rail: Min. 1feet. 4nos. Cable entry/exit Inspection: Consignee. | — | — | — | 3,99,670.8 | |
| — | 30.00 | — | — | ||
| Fixing of Quad termination box (drawing attached) and Termination of Quad Core on Quad termination box in ASM Room, ofc room etc. as per instruction of Rly. site engineer. All Fixing materials (1.2M x 1.2 M x 16 mm thickness ply wood board, casing, caping, screws, etc.) will be supplied by the contractor. wago terminal (Two in-put & Two out-put), separater & stoppers to be fixed on DIN Rail. Separater is to be fixed after each 6quad cable termination. Stopper is to be fixed on each side of DIN Rail after fixing 50nos. wago terminal on each DIN Rail. | — | — | — | 2,02,863.6 | |
| — | 20.00 | — | — | ||
| Supply of ABS Telephone instrument single push button, Caller Id Landline Set,, 16 digit single line LCD Display, Real-time clock with year, date and month display, Outgoing capacity: 5 outgoing phone memory, Incoming capacity: 30 incoming phone memory, 2 Level ringer volume switch, Mute option, Redial, call back, including all accessories, model: BEETEL C-51/similar, make: Beetel/similar Inspection: Consignee. | — | — | — | 19,920.2 | |
| — | 20.00 | — | — | ||
| Supply of 4 WIRE WAY STATION CONTROL TELEPHONE, as per IRS- TC 60/2007 with latest amdt. Including 4W telephone as per IRS: TC - 38/97, or latest, Make: Anu vidyut/Bentron/Epsilon. & supply of 12V/7AH Power supply unit for control phone. Inspection: Consignee. | — | — | — | 1,34,200 | |
| — | 20.00 | — | — | ||
| Supply of Decoder card as per IRS: TC 60/2007Amdt.-1or latest for 4 wire DTMF way station control equipment. Make: Anu vidyut/Bentron/Epsilon. Inspection: Consignee. | — | — | — | 1,06,252.2 | |
| — | 20.00 | — | — | ||
| Supply of power supply unit for telecom installation at way side station suitable to operate max 6 equipment of DTMF type (12V/7AH) battery with suitable battery charger) as per RDSO spec. No. IRS: TC-72-97 or latest. Make: Anu vidyut/Bentron/Epsilon. Inspection: Consignee. | — | — | — | 74,800 | |
| — | 20.00 | — | — | ||
| Installation of 4W way station DTMF equipment as per RDSO spec. no IRS-TC/60 /93 or latest (with 4 wire telephone as per spec. No IRS-TC-38 /97 or latest) as per instruction site engineer. Make- Bentron, Epsilon or similar. | — | — | — | 25,140 | |
| — | 10.00 | — | — | ||
| Supply of MODULAR TYPE DC-DC CONVERTER, INPUT-110VDC, OUTPUT-48VDC/10A. DC-DC convereter should be compatible to work in SCADA Network. MAKE: GALLANT OR SIMILAR. Inspection: Consignee. | — | — | — | 3,54,000 | |
| — | 20.00 | — | — | ||
| Supply & installation of JT 1:8 Fiber Optical Splitter 1310nm PLC Type SC Input SC Output G652D Fiber Box Type, Integrated with splice cassette and cable management rods., with all accessories, make: Syrotech/JT optics/similar, Inspection: Consignee. | — | — | — | 58,254 | |
| — | 2.00 | — | — | ||
| Supply of desktop/All in one PC. 13th Generation Intel Core™ i7 processor FreeDOS, 60.5 cm (23.8) diagonal, FHD, IPS display, anti-glare, Intel UHD Graphics 770, 16 GB DDR4-3200 RAM, 1 TB SSD Hard drive, Network interface: Intel I219-LM GbE, Wireless: Intel Wi-Fi 6E AX211 (2x2) and Bluetooth 5.3 wireless card, Webcam: 5 MP IR camera (pull-up) with integrated dual array digital microphones, Ports: 1 RJ-45; 1 HDMI 1.4; 2 SuperSpeed USB Type-A 5Gbps signaling rate (charging); 2 SuperSpeed USB Type-A 10Gbps signaling rate (charging); 1 Display Port™ 1.4a, Audio features: Realtek ALC3252 codec, internal speaker (optional), combo microphone/headphone jack, with Keyboard & mouse-wireless including all accessories & 3 Year Onsite Warranty. Make- HP/Lenovo/Dell or better. model: HP ProOne 440 G9 60.5 cm (23.8) All-in-One Desktop PC/similar. Inspection: Consignee | — | — | — | 1,94,916 | |
| — | 4.00 | — | — | ||
| Supply of 24-port GbE L2 Switch with GbE Uplink, Total port count: 28, 24 port PoE+ GbE 100/1000 Mbps + 4 port GbE combo (SFP/RJ-45) (28 ports total), 375W PoE+ (802.3af/ 802.3at) power budget, Switching capacity (Gbps): 56, Forwarding rate (Mpps): 42, Input power: 100 - 240 V AC, 50/60 Hz, Max. power consumption (watt): 22.5, Including all accessories, make: Zyxel/similar. model: GS2220-28/similar, Inspection: Rites. | — | — | — | 1,29,328 | |
| — | 26.00 | — | — | ||
| Supply of wall mount 6U Rack Enclosures Networking/Server Rack with power strip 5A socket 06 no. & MCB, Depth of the Rack: Upto 600mm, Transparent Toughened Glass used in front door, CRCA Steel rear door, with Secure Locks, Support cable entry from top or bottom, with fan tray and two nos. fans, , make: Valrack/Dlink/Digilink/similar. Inspection: Consignee. | — | — | — | 2,32,701.3 | |
| — | 50.00 | — | — | ||
| Supply of CAT-6 UTP RJ-45 patch cord (5mtr long) twisted stranded cable terminated with RJ45 modular plugs at both the ends. TIA/EIA-568-C.2 standard, Insulation Material : High Density Polyethylene, Outer Jacket: FR-PVC, Conductor diameter: 24 to 26 AWG, Conductor Metal : Bare Copper, Make D-Link/Similar Inspection: Consignee. | — | — | — | 13,056.5 | |
| — | 15.00 | — | — | ||
| Execution of Thermo Shrink Jointing Kit as per site engineer's instruction at various location. Cable jointing shall be carried out at site as per the detailed procedure suggested by RDSO approved manufacturers of thermoshrink jointing kit for PIJF & 6-Quad cable. Jointing kit will be supplied by Railway. Inspection: Consignee. | — | — | — | 11,500.65 | |
| — | 15.00 | — | — | ||
| Supply of Thermo shrink jointing kit TSF2 as per RDSO No. RDSO/SPN/TC/57/2015 or latest for PIJF cable 0.63mm dia. Copper conductor as per IRS:TC-41/97 with latest amdt for upto 50Pairs. Inspection: Consignee. | — | — | — | 43,882.05 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TECHNICALCIRCULAR-124-HDPEColour.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf
ATTACHMENT
TenderDocument_SnT.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
AllAnnexure.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
TypicaldiagramofEarthElectrodeGIPipe_2025.pdf
ATTACHMENT
TELE-BOX-QuadTerminationBox_2025latest.pdf
ATTACHMENT
Annexure-A.pdf
ATTACHMENT
CABLECUT_DiggingJPO_12.08.2024.pdf
ATTACHMENT
GCCCorrectionslip11.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .