Loading…
Loading…
Tender Value
₹2.3 L
EMD Value
₹4,700
Closing Date
31 Aug 2026, 3:00 pm3d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
TENDER ELG
13 conditions · 4 needing a document upload
The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with Provision for sinking of Deep Tube Well (300 mm x 200 mm) dia at Sorting Yard Coaching Complex under AEN/HQ/HWH.
EL-HWH-25-21-3670~ER
EL-HWH-25-21-3670
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹4,700
10 Aug 2026
10 Aug 2026
17 Aug 2026
57 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,34,673 | ||
| — | — | — | Above/ 2044.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos.single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phaseand neutral in PVC conduit / casing along with 1 no. singlecore HRFR / FRLS grade, PVC insulated, copper conductorcable of size 1.5 sq.mm, 1100V grade for Earth ContinuityConductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 7.00 | — | — | |
| — | — | — | Above/ 326.00 Below/P | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socketand one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 2.00 | — | — | |
| — | — | — | Above/ 3400.00 Below/P | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 50.00 | — | — | |
| — | — | — | Above/ 4640.00 Below/P | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 20.00 | — | — | |
| — | — | — | Above/ 549.00 Below/P | ||
| Extra cost for conceal wiring in respect to PVC conduit / casingfor light, fan, plug, power plug, multi-plug point etc. includingmake good of wall surface as its original condition | — | 9.00 | — | — | |
| — | — | — | Above/ 1330.00 Below/P | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | 70.00 | — | — | |
| — | — | — | Above/ 1078.00 Below/P | ||
| Extra cost involvement for modular switch, bell push, plug socket,fan regulator, USB point, TV socket etc. with other accessories( Make of Modular switch, socket, box, cover plate etc. - ABB /Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 11.00 | — | — | |
| — | — | — | Above/ 800.00 Below/P | ||
| Drawing of cable on wall / structure with suitable size and shapeGI clamps including supply of suitable size GI Clamp and GI nut-bolts and commissioning of cable( Cable will be supplied by Railway ) | — | 20.00 | — | — | |
| — | — | — | Above/ 4680.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting with covering of cable through suitabe dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 orhigher) along with refilling the trench and make good of surface as its original condition( Cable will be supplied by Railway ) | — | 20.00 | — | — | |
| — | — | — | Above/ 18240.00 Below/P | ||
| Trenching and laying of cable under ground by soil cutting with covering of cable through suitable dia HDPE pipe includingsupply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface asits original condition. ( Cable will be supplied by Railway ) | — | 120.00 | — | — | |
| — | — | — | Above/ 1700.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith makegood of floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 20.00 | — | — | |
| — | — | — | Above/ 7030.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make goodof floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | Above/ 1730.00 Below/P | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. longGI pipe ( Make - Tata / Jindal / Bansal ) for protectionof cable on pole with proper GI clamps and GI nuts & boltsincluding supply of GI pipe( Cable will be supplied by Railway ) | — | 2.00 | — | — | |
| — | — | — | Above/ 2310.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with IngressProtection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul,Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics& BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current,Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greaterthan 50000 burning hours, The Luminaire & Driver both should be ofsame make / brand and individually BIS approved with 60 months warranty including fixing with suitable dia heavy gauge GI bend pipewith GI clamps made of GI flat of size 40mm x 6mm and GI nut-boltson structure / wall.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 2.00 | — | — | |
| — | — | — | Above/ 848.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of 20-22W LED batten (Type of LED - Surface Mounting Device ) tube with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, extruded aluminium housing and milky polycarbonate diffuser ( LEDchip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago,Cree, Lednium, APT Electronics & BridgeLux ), LED luminaire system efficacy - Greater than 120 Lumens per Watt @ 350mA drive current,Colour Temperature - 6500K (Cool white), CRI>80, SDCM<5, Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD<10%, Driver HV Cut off @ 325V/440V (P2P) protection for8 hrs., Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and indivi- dually BIS approved with 60 months warranty including fixing withGI clamps made of GI flat of suitable size & GI nut-bolts.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 4.00 | — | — | |
| — | — | — | Above/ 2360.00 Below/P | ||
| Supply of AC Wall Bracket Fan 400 mm sweep suitable for operation on 1Ph, 220- 240V, 50 Hz supply system includingfixing, connection and commissioning with GI clamps madeof GI flat of suitable size and GI Nut-Bolts on wall / structure. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) | — | 1.00 | — | — | |
| — | — | — | Above/ 5044.00 Below/P | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 8 way, 50Hz, complete with 4 nos. SP MCB of current rating from6A to 32A, 10kA, 240V, 50Hz as per requirement of load and1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V,50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 1.00 | — | — | |
| — | — | — | Above/ 121.00 Below/P | ||
| Fixing, connection and commissioning of above SPN MCB DBwith suitable arrangement including all incoming and outgoingcable connection with suitable cable termination arrangement. | — | 1.00 | — | — | |
| — | — | — | Above/ 19004.00 Below/P | ||
| Supply, fixing, connection, testing and commissioning of MCCB with Microprocessor Release of breaking capacity 36 kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection5) Adjustable neutral overload protection, 6) Provision of Thermal Memory 7) All Microprocessor protection-based MCCB / ACB must have facility of individual 'LSIG' fault indication,suitable for Release Range 40-100A, 4 Pole including metal enclosure with internal wiring.( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 1.00 | — | — | |
| — | — | — | Above/ 60380.00 Below/P | ||
| Supply of Submersible Pump Motor set in multistageconstruction of maximum pump discharge 11.67 LPS (10000 GPH approx.) at 57 Mtrs. total Head (187 Ft approx.) with 15 HP ( 11 KW ) AC induction motor suitable foroperation on 3 Phase, 415V, 50Hz, AC supply system complete with all accessories such as total 65 Mtrs. length of 3 core flat PVC insulated flexible copper conductor cable of size 4.0 sq.mm, 1100V grade ( motor to starterpanel ), one flow meter, one delivery sluice valve one Non-Return Valve, one pressure gauge and all other accessories. ( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 1.00 | — | — | |
| — | — | — | Above/ 3152.00 Below/P | ||
| Installation, testing and commissioning of Submersible Pump-Motor set ( 10000 GPH ) and column pipe, supportingclamps and other accessories. | — | 1.00 | — | — | |
| — | — | — | Above/ 8940.00 Below/P | ||
| Supply of Submersible pump controller in sheet steel enclosure incorporated with Fully Automatic Star-Delta Starter with singlephase preventor suitable for 11 KW / 15 HP, 3Ph, 415V, 50Hz ( 10000 GPH ) pump motor ( similar to LK (L&T) Type -MU-G15 FASD Starter, Cat.No.- CS94091 or equivalent ).( Make - LK (L&T) / Siemens / ABB / BCH ) | — | 1.00 | — | — | |
| — | — | — | Above/ 466.00 Below/P | ||
| Installation, connection, testing and commissioning of above starter panel by suitable size GI clamps and nut-bolts. | — | 1.00 | — | — | |
| — | — | — | Above/ 6852.00 Below/P | ||
| Supply of heavy gauge GI pipe of dia 75mm with one end socket as per IS:1239 (Part I) of 1990 or latest.( Make - Tata / Jindal / Bansal ) | — | 12.00 | — | — | |
| — | — | — | Above/ 31344.00 Below/P | ||
| Supply of heavy gauge GI pipe of dia 100mm with one end socket as per IS:1239 (Part I) of 1990 or latest.( Make - Tata / Jindal / Bansal ) | — | 48.00 | — | — | |
| — | — | — | Above/ 8020.00 Below/P | ||
| Supply of Supporting Clamps for holding column pipe madeof GI flat of size 400mm x 100mm x 12mm along with GI nuts and bolts | — | 20.00 | — | — | |
| — | — | — | Above/ 2487.00 Below/P | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip.( For details not covered in this specifications, IndianStandard Code of Practice for earthing IS : 3043 - 1987,Reaffirmed - 1996 should be followed ) | — | 1.00 | — | — | |
| — | — | — | Above/ 35798.00 Below/P | ||
| Goods & Services Tax ( at present @ 18% ) | — | 1.00 | Lumpsum | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
3670Clause_1.pdf
ATTACHMENT
TenderBooklet.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf Tender form and annexure
ATTACHMENT
Advancecorrectionslipsupto11.pdf Advance Correction Slip
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].