| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹12.5 L+₹6.7 L (53.2%)Accepted-AOC PLOT NO 82 S V B P NAGAR DARRI JAMNIPALI KORBA KORBA CHHATTISGARH 495450 | KORBA | CHHATTISGARH | 495450 | L2 | Accepted-AOC L1 bidder | |
| 2 | L1₹12.5 LRejected-AOC E 29 A ROAD NO 2 I P I AREA KOTA RAJASTHAN 324005 | KOTA | RAJASTHAN | 324005 | L1 | Rejected-AOC L2 bidder | |
| 3 | Rejected-Technical NO 119 1ST FLOOR SURJA DEVI SHUKLA COMPLEX NEAR GANJBANS TALL RAIPUR 492009 | RAIPUR | RAIPUR | CHHATTISGARH | 492009 | - | Rejected-Technical Rejected on guarantee clause non acceptance | |
| 4 | Rejected-Technical | - | Rejected-Technical Reject on PQR 3c | |
| 5 | Rejected-Technical BEHIND MPSEB HOSPITAL MPN 2 BIRSINGHPUR 484552 M P | BIRSINGHPUR | UMARIA | MADHYA PRADESH | 484552 | - | Rejected-Technical rejected on technocmmercial ground |
Tender Value
₹22.3 L
EMD Value
₹55,900
Closing Date
13 Aug 2019, 3:30 pmClosed
SE PnW Birsinghpur
SE PnW Birsinghpur
Supply installation and commissioning of IN SITU Oxygen analyzer for measurement of O2 percentage in flue gas for 1x500 MW Unit of SGTPS MPPGCL Birsinghpur
2019_MPPGC_26687_1
26687
Open Tender
Miscellaneous Goods
Item Wise
90 days
SGTPS UMARIA
As per NIT
12 documents required · 12 mandatory
₹1,000
Sr AO SGTPS MPPGCL Birsinghpur
₹55,900
Yes
10 Mar 2022
12 Jun 2019
17 Aug 2019
12 Jun 2019
13 Aug 2019
12 Jun 2019
Supply of In Situ Zirconia Oxygen Analyzer (for flue gas O2% measurement) Specifications- Probe length - 6 FT(1830 (mm) detector/ sensor should be mounted at the tip of probe . Cell - Zirconium oxide Power supply - 240 VAC, 50hz Output - one 4-20mA DC, with HART capability. Measuring Range- 0.01 to 100 %O2 Response time - T90 is less than 5 sec Repeatability - Typically +/-0.5% Linearity – ( +/- 1%) System Accuracy - <±0.75 % of reading or ± 0.05 % O2,which ever is greater ,based on nominal range of 0.01 to 25 % or 20 to 100 %O2 Enclosure - NEMA 4X, IP66 for electronics, Suitable for safe area Material - 316 SS Ambient temp – (-200 C to 550C) Process temperature up to - 8000 C Protective shield - For the probe installed in highly abrasive flue gas path Protective shield material-446 SS( for highly sulphuric acid area) Zero gas cylinder - 10 Ltr W.C.CS cylinder, containing 0.4% o2 balance N2 Span gas cylinder - 10 Ltr W.C.CS cylinder, containing 8% o2 balance N2 Flow meter
Installation & commissioning of all In-situ oxygen Analyzer shall be completed by firm with one to one replacement/fitment guarantee of existing analyzer
engineering equipments
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .