Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.0 LAccepted-AOC | ₹35.0 L | 1 | Accepted-AOC L1 |
| 2 | 2₹39.9 L+₹4.9 L (14.1%)Rejected-Finance GROUND 35 PALM AVENUE BALLYGUNGE KOLKATA WEST BENGAL 700019 | KOLKATA | WEST BENGAL | 700019 | ₹39.9 L+₹4.9 L (14.1%) | 2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹36,460
Closing Date
5 Nov 2019, 6:00 pmClosed
DGM(T)
Haldia-Mourigram-Rajbandh-Barauni Pipelines, P.O. Duilya, Andul-Mouri, Mourigram Distt. Howrah 711 302
Annual Maintenance Contract for Repair and Maintenance of Fire Fighting system at HMRBPL and PHDPL stations
2019_HMRBM_105908_1
HMRBTS1954
Open Tender
Mechanical Works
Works
365 days
HMRBPL and PHDPL locations
Please refer to Tender document
6 documents required · 6 mandatory
₹36,460
Yes
24 Jan 2020
1 Oct 2019
6 Nov 2019
1 Oct 2019
5 Nov 2019
1 Oct 2019
Amount
Assistance in carrying out maintenance and inspection of fire extinguishers on monthly basis including pastings/ marking of maintenance date, cleaning, replacement of defective parts ( IOCL supplied), measuring weight and charges for labour, including oiling, greasing, testing as per direction of EIC inclusive of all tools &tackles, consumables, transportation, labour charges etc and measuring instruments for the same as directed by the EIC/ Site engineer and submitting the reports of the inspection as per HSE manual format (payment of spares not supplied by IOCL shall be made as per respective items)
For 10/9 KG. CAPACITY DCP extinguisher
For 75/70/50 KG. CAPACITY DCP extinguisher
For 4.5/5 KG. CAPACITY DCP extinguisher
For 2 KG. CAPACITY CO2 extinguisher
For 4.5 KG. CAPACITY CO2 extinguisher
For 6.8 KG. CAPACITY CO2 extinguisher
For 2 KG CAPACITY Clean agent extinguisher
Monthly: Checking, inspection, maintenance, greasing, cleaning, oiling etc. of Double headed hydrant valves alongwith all tools, tackles, manpower, material etc.
Checking, inspection, servicing, maintenance, greasing, cleaning, oiling, replacement of disc washer, blank cap if any including complete overhauling etc. of Double headed hydrant valves alongwith all tools, tackles, manpower, material etc. Payment for disc washer, coupling washer & blank cap shall be made separately.
Supplying and fitting of Hydrant Disc Washer as per directions of Engineer-in-Charge
Supplying and fitting of Fire Hydrant/ Fire Hose coupling washer
Supply and fitting of blank cap (as per IS 5290 , red colour with GI chain) suitable for 63 mm hydrant outlet as per direction of EIC
Supplying & fitting spindle assembly (Gunmetal)
Monthly maintenance of 750 GPM Monitors: Oiling & greasing through grease nipple provided on bearing, worm wheel and worm shaft, cleaning, performance checking for complete vertical and horizontal movement, nozzle movement, water throw, foam suction, ensuring proper tightning of flanges, clearing the debris around the nozzle etc as per approved procedure including tools & tackles, report submission complete as per direction of Site Engineer / EIC. Water resistant low friction synthetic grease, grease gun and all other consumable etc shall be arranged by vendor. After testing, AFFF jerry-can must be positioned and replinished near monitor including shifting, transportation etc.
Assistance in hydrotesting of fire fighting delivery hose of dia 63 mm on half-yearly basis (Type A and B ) by making arrangement of hydraulic pump, blind, shifting from plant area, building, drying etc as perapproved procedure along with CISF including tools & tackles, reportsubmission complete as per direction of Site Engineer / EIC.
Supply and installation of Clear PVC, Spiral wound hose (pick-up tube) of length 3 m length and dia 40 mm with SS jublee clamp for tightning suitable for existing connectors of 750 GPM Monitor
Supply and installation of SS strainer of dia 30mm with SS jublee clamp suitable for 40 mm pick up tube of 750 GPM Monitor
Supply and installation of SS drain valve size 15 mm/other Suitable for 750 GPM Monitor.
Hydrtest of DCP extinguishers, making out by pouring outside the cylinder, internal /external cleaning and repairingof various accessories such as cap assembly , discharge hose pipes, pressure gauge etc. by supplyling manpower gasket washer etc. Cylinder surface preparation / and application of one coat of red oxide primer bfollowing by two coat of synthetic enamel paints (fire red) ( Hydrotest proceudre will be same as briefed in IS 2190: 2010 )
For 50/70/75 KG. CAPACITY DCP extinguisher
For 10/9/5 KG. CAPACITY DCP extinguisher
Hydrostatic testing, inspection of safety valve and refilling of high pressure CO2 cylinder through CCE approved party and charging up to required pressure including taking delivery of the cylinder from the station and returning the same inclusive of all labour material ,transporation and all the other incidental expenses. The cylinder is to be returned back to the station within two week from the date of receiving from the station.
For 6.8 KG. CAPACITY CO2 extinguisher
For 4.5 KG. CAPACITY CO2 extinguisher
For 2 KG. CAPACITY CO2 extinguisher
Aluminium Painting & Refilling of CO2 gas in cartridges for using in DCP extinguishers including all labour, transportation etc. complete as per specification and direction of EIC/Site-Engineer. (CO2 CARTRIDGE OF 120/ 200g MS)
REPLACEMENT OF DEFECTIVE PARTS BY SUPPLY AND FITTING OF ITEMS FOR 5 KG DCP EXTINGUISHER
Discharge hose with squeeze grip, hose should not burst or show leakage before 50 Kgf/cm2.
Safety clip (metal) with nylon thread
DCP extinguisher cap washer
Inner container
Cap Assembly Gun Metal
Discharge tube washer
REPLACEMENT OF DEFECTIVE PARTS BY SUPPLY AND FITTING OF ITEMS FOR 9 KG/10 KG DCP EXTINGUISHER
Discharge hose with squeeze grip, hose should not burst or show leakage before 50 Kgf/cm2.
Safety clip (metal) with nylon thread
DCP extinguisher cap washer
Inner container
Cap Assembly Gun Metal
Discharge tube washer
REPLACEMENT OF DEFECTIVE PARTS BY SUPPLY AND FITTING OF ITEMS 50/70/75KG DCP EXTINGUISHER
Discharge hose with clamps (6.5 mtr length). Hose should not burst or show leakage before a pressure of 50 Kgf/cm2.
Brass connection tube between CO2 cylinder & DCP cylinder with leather washer.
Cap washer
Trolley wheel set with required fittings
REPLACEMENT OF DEFECTIVE PARTS BY SUPPLY AND FITTING OF ITEMS FOR FOR CO2 EXTINGUISHERS
HDPE discharge horn for 2 Kg/4.5 kg CO2 extinguisher along with bend pipe fitting complete in all respect as per direction of EIC.
HDPE discharge horn for 6.8 Kg capacity CO2 extinguishers with fittings as per direction of EIC.
High pressure discharge hose for 4.5 Kg/ 6.8 Kg Co2 extinguisher with fittings as per direction of EIC.
Trolley wheel set for 6.8 Kg CO2 extinguisher along with handle complete with fittings as per direction of EIC.
Handle for 2 Kg /4.5 Kg CO2 extinguisher
Safety pin with nylon string for CO2 extinguisher (For all sizes)
Supply & fitting plastic safety pin holder in CO2 extinguisher.
Supply & fitting of rubber beeding of the complete one hose box (both doors) as per direction of EIC including removing of worn out rubber beeding, labour charges, tools & tackles etc. complete in all respect
Supply & fitting of glass of hose box (Both side of the box) inclusive of rubber beading wherever required complete in all respect inclusive of material, labour, consumables etc. (Rate inclusive of both glasses & rubber beading)
Supply and Fitting of new wind sock (fluoroscent in two colour), removing of old wind sock made out of synthetic cloth in flood light tower, buildings, upto height of 10 M, as per direction of site engineer/ EIC. Approval to be granted for wind sock prior to supply.
Erection and supply of stand post of wind sock (up to height 15 mtr.) in place of damaged stand post as per specification of IOC and EIC including tools and tackles, labour chargesets complete in all respect.
Maintenance/checking/Refilling of Fire buckets with stand supplied by contractor & canopy asper the direction and satisfaction of Site engg/ EIC.
Refilling of DCP Ext. 10/09/05 Kg. Cap. DCP to be provided by IOC.
Refilling of DCP Ext. 50/70/75 Kg. Cap.DCP to be provided by IOC.
Refilling & Hydrotesting of Breathing Apparatus set cylinders with dry compressed air up to a pressure of 300 bar as per OISD guidelines and as per the direction and satisfaction of Site engg/ EIC, inclusive of transporation handling charges,hydrtoesting from CCE approved party complete in all respect.
Replacement of broken glass broken of MCP ( Size 4.5"X 3.5") as per the direction and satisfaction of Site engg/ EIC.
Vishal Profin Pvt. ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .