Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.4 L+₹71,325 (2.68%)Rejected-Finance PLOT NO 52 BAKSHI NAGAR JAMMU 180001 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹27.7 L+₹1.1 L (4.06%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹28.9 L+₹2.2 L (8.24%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹30.8 L+₹4.2 L (15.6%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 May 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN 913862 c/o 56 APO
Repairs to roof treatment and plastering to certain building in South Zone under AGE B/R Dett A GE 862 EWS
2020_MES_341958_1
GER-10/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹60,000
Yes
27 Jun 2020
30 Apr 2020
1 Jun 2020
30 Apr 2020
30 May 2020
16 May 2020
60 days
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheeting in roof covering complete all as specified and directed.
Dismantling framed trusses N.exc 10 M span of any description complete all as specified and directed.
Fixing only of roof trusses (framed), trussed, purlins, crane gantries, rails and fastening, and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed. (using old steel sections obtained from dismantling of framed trusses).
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
Rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but not exceeding 10 cm long and diameter of neck 16 to 20 mm complete all as specified and directed.
Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long and diameter of neck exceeding 20 mm but not exceeding 25mm complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Rolled mild steel work as in wind ties using flat iron including all necessary drilling bolting, riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per instructions including dismantling of existing board etc complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
Stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Description all as per srl item No 14 above but except stones complete all as specified and directed. (using old serviceable stones retrieved from demolition after cleaning).
Extra over stone walling of any type of stones for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Brick work with sub class "B" bricks straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Rendering 20mm thick in CM 1:6 on stone masonry surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20mm thick in CM 1:4 on stone masonry surfaces of wall, finished even and smooth without using extra cement mixed with water proofing compound as per manufracturer's instructions complete all as specified and directed. Note:- Supply only WPC shall be measured & paid seprately.
Taking down cement plaster, any description on brick or stone or cement concrete of walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement mixed with water proofing compound as per manufracturer's instructions complete all as specified and directed. Note:- Supply only WPC shall be measured & paid seprately.
Rendering 15mm thick in CM 1:4 on other than fair faces brick masonry surface or on store masonary of walls, finished even and smooth without using extra cement mixed with water proofing compound as per manufracturer's instructions complete all as specified and directed. Note:- Supply only WPC shall be measured & paid seprately.
Supply only integral water proofing compound complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over and including a coat of cement primer complete all as specified and directed.
Preparation of newly plastered surface of walls and applying two coats of oil bound distemper over and including a coat of cement primer complete all as specified and directed.
Preparation of new or previously untreated steel or iron surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of Synthetic enamel paint over and including a coat of zinc chrome red oxide primer complete all as specified and directed.
Preparation of old steel surfaces and applying one coats of synthetic enamel paint any tint, surface of any description over 10cm width or girth not other wise described complete all as specified and directed.
Complete removal of existing treatment from old decorated surfaces of walls and applying two coats of oil bound distemper over and including a coat Birla wall care putty 1.5mm thick and a coat of cement primer complete all as specifed and directed.
40mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in padding over roof surface to maintain proper slope, finishing concrete surface even & smooth without using extra cement complete all as specified directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S Jasbir Singh
M/S. Choudhary Dewan Chand And Sons
RAJINDER CHOUDHARY
M/S SURINDER PAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .