| Sl No | Description | Qty | Unit | AAYANSH ELECTRICAL SOLUTIONS L3 | A.A.ENTERPRISES L4 | ARYAN ENTERPRISES L2 | M/s Electrical Engineers L1 |
|---|---|---|---|---|---|---|---|
| 1.00Providing, Installation and commissning of Digital Relay (make C&S, Ashide and ABB) in Place of Numerical/Mechanical/Damaged (Burnt) Relay of 11 KV Feeders at 33/11 KV Sub-Stations of EDD Hapur, In the Jurisdiction of ETL-Hapur of ETD-Hapur, Under EDC-Hapur. | |||||||
| 1.01 | Providing, Installation and commissning of Digital Relay (make C&S, Ashide and ABB) in Place of Numerical/Mechanical/Damaged (Burnt) Relay of 11 KV Feeders at 33/11 KV Sub-Stations of EDD Hapur, In the Jurisdiction of ETL-Hapur of ETD-Hapur, Numerical (3O/C+IE/F) should have following technical specification :
(i) Current rating : 1A/5A site selectable.
(ii) Aux Supply : 24-23 V AC/DC rated (As per IEC).
(iii) Draw out with CT shorting.
(iv) SCADA compatible with RS 485 Port.
(v) Frant LEDs display for following : L1, L2, L3, E Trip for faulty Y phase/Earth, Low set trip, high set trip.
(vi) Relay should have minimum 4 DI, 6 DO.
(vii) The relay should have cold load pick up, harmonic blocking and CBFP. It should have minimum 10 fault records and 10 events records.
Selting Ranges
(a) Ip> 5 to 400 % is step of 1 %
(b) Ip>> 5 to 3000% in step of 1%
(c) Ie> 5 to 250 % is step of 1 %
(d) Ie>> 5 to 1500 % is step of 1 %
(e) Tp> 0.01 to 1.50 % is step of 0.01
(f) Te> 0.01 to 1.50 % is step of 0.01
(g) Tp>> 0.01 Sec to 20 Sec in step of 0.01 Sec
(h) Te>> 0.01 Sec to 20 Sec in step of 0.01 Sec
All T&P, Labour will be provided by contractor in all respects | 25 | Nos. | 21,000 ₹5.3 L | 5,000 ₹1.3 L | 18,000 ₹4.5 L | 19,550 ₹4.9 L |
| 1.02 | Retro-fitting / modification work in existing VCB/DCB panel for installation of protection relay of different make including modification of relay slot, mounting arrangement, wiring adjustment, drilling/cutting, supply of small hardware/material, transportation, labour and complete installation as required for proper commissioning of relay – complete in all respect will be done by Contractor. | 25 | Nos. | 5,000 ₹1.3 L | 22,500 ₹5.6 L | 6,000 ₹1.5 L | 2,500 ₹62,500 |
Tender Value
₹6.3 L
EMD Value
₹6,300
Closing Date
27 Mar 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER EDC HAPUR
PROVIDING INSTALLATION WIRING TESTING COMMISSIONING AND DISMANTLING OF NEW DIGITAL RELAY IN PLACE OF DAMAGED MECHANICAL EARTH FAULT AND OVER CURRENT RELAY OF 11 KV VCB FOR PROPER TRIPPING SYSTEM AT 33/11 KV SUB STATIONS IN O AND M SCHEME ETD HAPUR
2026_PVVNL_1127246_1
53(W)/EDCH/2025-26
Open Tender
Electrical Works
HAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER, EDC, HAPUR
₹6,300
1 Apr 2026
19 Mar 2026
27 Mar 2026
19 Mar 2026
27 Mar 2026
19 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing, Installation and commissning of Digital Relay (make C&S, Ashide and ABB) in Place of Numerical/Mechanical/Damaged (Burnt) Relay of 11 KV Feeders at 33/11 KV Sub-Stations of EDD Hapur, In the Jurisdiction of ETL-Hapur of ETD-Hapur, Under EDC-Hapur. | |||||
| 1.01 | Providing, Installation and commissning of Digital Relay (make C&S, Ashide and ABB) in Place of Numerical/Mechanical/Damaged (Burnt) Relay of 11 KV Feeders at 33/11 KV Sub-Stations of EDD Hapur, In the Jurisdiction of ETL-Hapur of ETD-Hapur, Numerical (3O/C+IE/F) should have following technical specification :
(i) Current rating : 1A/5A site selectable.
(ii) Aux Supply : 24-23 V AC/DC rated (As per IEC).
(iii) Draw out with CT shorting.
(iv) SCADA compatible with RS 485 Port.
(v) Frant LEDs display for following : L1, L2, L3, E Trip for faulty Y phase/Earth, Low set trip, high set trip.
(vi) Relay should have minimum 4 DI, 6 DO.
(vii) The relay should have cold load pick up, harmonic blocking and CBFP. It should have minimum 10 fault records and 10 events records.
Selting Ranges
(a) Ip> 5 to 400 % is step of 1 %
(b) Ip>> 5 to 3000% in step of 1%
(c) Ie> 5 to 250 % is step of 1 %
(d) Ie>> 5 to 1500 % is step of 1 %
(e) Tp> 0.01 to 1.50 % is step of 0.01
(f) Te> 0.01 to 1.50 % is step of 0.01
(g) Tp>> 0.01 Sec to 20 Sec in step of 0.01 Sec
(h) Te>> 0.01 Sec to 20 Sec in step of 0.01 Sec
All T&P, Labour will be provided by contractor in all respects | 25 | Nos. | - | - |
| 1.02 | Retro-fitting / modification work in existing VCB/DCB panel for installation of protection relay of different make including modification of relay slot, mounting arrangement, wiring adjustment, drilling/cutting, supply of small hardware/material, transportation, labour and complete installation as required for proper commissioning of relay – complete in all respect will be done by Contractor. | 25 | Nos. | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.89 MB
Standbidnew53.pdf
Tender Documents • 0.69 MB
BOQ_2102396.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid