| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical DUE TO SHORTFALL OF REQUISTE DOCUMENTS |
| Sl No | Description | Qty | Unit | GD ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00 | A: Ward No.1
SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=6000 W having Air Flow Rate >=590 cfm in Ward 1 with minimum 3 star and of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable.Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. | 12 | nos. | 71,000 ₹8,52,000 Lowest |
| 2.00 | SITC of 1.5 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 5200 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=5200 W having Air Flow Rate >=570 cfm in Ward 1 with minimum 3 star of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. | 4 | nos. | 51,000 ₹2,04,000 Lowest |
| 3.00 | SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek onlyalong with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes . | 12 | nos. | 12,000 ₹1,44,000 Lowest |
| 4.00 | SITC of Wall mounted Copper wound stabilizer for 1.5 TR Air conditioners of capacity 4 KVA (voltage range 90 volts-300 volts) of reputed Make i.e. Electricfield/Servocon/Aulten/Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. | 4 | nos. | 11,000 ₹44,000 Lowest |
| 5.00 | SITC of Heavy Duty Main Electrical Panel (Powder Coated) which includes MCCB 630A-4 Pole of breaking circuit capacity 50KA and of standard make i.e. Schneider and bus bar of required Size for 3 phases and neutral for connecting various ACs wires along with phase indicator and other allied accessories. The panel is to be installed on the roof and should be made weather-proof. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. | 1 | job | 92,000 ₹92,000 Lowest |
| 6.00 | Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab,Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. | 450 | mtrs | 250 ₹1,12,500 Lowest |
| 7.00 | Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. | 180 | mtrs | 220 ₹39,600 Lowest |
| 8.00 | Providing and laying of extra FRLS PVC insulated 2.5 sq mm 4 core communication cable ISI Marked (using conduits and wire fasteners / cable clips/ conduit fasteners) of reputed make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning indoor unit to the installed air conditioning outdoor units, as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. | 720 | ft | 90 ₹64,800 Lowest |
| 9.00 | Providing and fitting of MCB 40 Amp for 2.0 TR Capacity Air conditioners with of standard make i.e. Havells, L&T,Schneider, Siemens only with gang box (complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges . | 12 | set | 750 ₹9,000 Lowest |
| 10.00 | Providing and fitting of MCB 32Amp for 1.5 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box(complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges and taxes. | 3 | set | 600 ₹1,800 Lowest |
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
25 Sept 2025, 4:00 pmClosed
Superintending Engineer, Mechanical Hospital Circ
Superintending Engineer, Mechanical Hospital Circ
Provisioning of Split Air Conditioning System Hot and Cold in Ward no. 1,2,3 and 16 and Air Conditioning System with heater bank in Ward no.20 along with allied works at Govt. SMGS Hospital Jammu
2025_PWDJK_278754_2
MHCJ/Tech/e-NIT/2025-26/05
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
120 days
SMGS HOSPITAL JAMMU
as per e nit
2 documents required · 2 mandatory
₹3,000
Superintending Engineer, Mechanical Hospital Circ
₹4.4 L
Superintending Engineer, Mechanical Hospital Circ
13 Dec 2025
4 Sept 2025
26 Sept 2025
4 Sept 2025
25 Sept 2025
10 Sept 2025
4 Sept 2025 - 15 Sept 2025
8 Sept 2025
Amount
A: Ward No.1 SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=6000 W having Air Flow Rate >=590 cfm in Ward 1 with minimum 3 star and of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable.Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes.
SITC of 1.5 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 5200 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=5200 W having Air Flow Rate >=570 cfm in Ward 1 with minimum 3 star of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes.
SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek onlyalong with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Wall mounted Copper wound stabilizer for 1.5 TR Air conditioners of capacity 4 KVA (voltage range 90 volts-300 volts) of reputed Make i.e. Electricfield/Servocon/Aulten/Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes.
SITC of Heavy Duty Main Electrical Panel (Powder Coated) which includes MCCB 630A-4 Pole of breaking circuit capacity 50KA and of standard make i.e. Schneider and bus bar of required Size for 3 phases and neutral for connecting various ACs wires along with phase indicator and other allied accessories. The panel is to be installed on the roof and should be made weather-proof. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes.
Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab,Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of extra FRLS PVC insulated 2.5 sq mm 4 core communication cable ISI Marked (using conduits and wire fasteners / cable clips/ conduit fasteners) of reputed make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning indoor unit to the installed air conditioning outdoor units, as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes.
Providing and fitting of MCB 40 Amp for 2.0 TR Capacity Air conditioners with of standard make i.e. Havells, L&T,Schneider, Siemens only with gang box (complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges .
Providing and fitting of MCB 32Amp for 1.5 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box(complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of PVC drain pipes of assorted sizes viz. ¾”,etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc.with Insulation. Complete job must be as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying (with clamps/supports wherever required as per site conditions) of 185mm² 3.5 Core Aluminum armoured cable from main electric source (Transformer) to installed electric Panel. Complete job as per site requirement and as per instructions of Engineer-in-charge and also includes cost of material, labour, GST rates, Transportation, installation and all other charges and taxes.
Windows’ Work (According to JKSSR 2022) 15.13 Taking out doors, windows and clerestory window shutters (steel or wood)including stacking within 50 meters lead : 15.13.1 Of area of 3 sqm. and below
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.1 For fixed portion 22.1.1.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)22.1.2.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.3 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item.) 22.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
9.72 Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges (heavy weight) with Stainless Steel screws etc. complete. 9.72.3 75x50x2.50 mm
9.99 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 9.99.5 100x10 mm
9.102 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.102.2 100 mm
9.104 Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
14.1 Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead 14.1.2 With cement mortar 1:4 (1 cement : 4 coarse sand)
13.88 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.88.1 1 mm thick
13.89 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required,to achieve even shade and colour. - 2 coats Windows’ Work (According to JKSSR 2022)
B: Ward No.2 1 SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=6000 W having Air Flow Rate >=590 cfm in Ward 2 with minimum 3 star and of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of 1.5 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 5200 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=5200 W having Air Flow Rate >=570 cfm in Ward 2 with minimum 3 star of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Wall mounted Copper wound stabilizer for 1.5 TR Air conditioners of capacity 4 KVA (voltage range 90 volts-300 volts) of reputed Make i.e. Electricfield/Servocon/Aulten/Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Heavy Duty Main Electrical Panel (Powder Coated) which includes MCCB 630A-4 Pole of breaking circuit capacity 50KA and of standard make i.e. Schneider and bus bar of required Size for 3 phases and neutral for connecting various ACs wires along with phase indicator and other allied accessories. The panel is to be installed on the roof and should be made weather-proof. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of extra FRLS PVC insulated 2.5 sq mm 4 core communication cable ISI Marked (using conduits and wire fasteners / cable clips/ conduit fasteners) of reputed make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning indoor unit to the installed air conditioning outdoor units, as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
Providing and fitting of MCB 40 Amp for 2.0 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box (complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges .
Providing and fitting of MCB 32Amp for 1.5 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box(complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc. with Insulation. Complete job must be as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying (with clamps/supports wherever required as per site conditions) of 185mm² 3.5 Core Aluminum armoured cable from main electric source (Transformer) to installed electric Panel. Complete job as per site requirement and as per instructions of Engineer-in-charge and also includes cost of material, labour, GST rates, Transportation, installation and all other charges and taxes.
Windows’ Work (According to JKSSR 2022) 15.13 Taking out doors, windows and clerestory window shutters (steel or wood)including stacking within 50 meters lead : 15.13.1 Of area of 3 sqm.
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.1 For fixed portion 22.1.1.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) 22.1.2.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.3 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item.) 22.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
9.72 Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges (heavy weight) with Stainless Steel screws etc. complete. 9.72.3 75x50x2.50 mm
9.99 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 9.99.5 100x10 mm
9.102 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.102.2 100 mm
9.104 Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
14.1 Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead 14.1.2 With cement mortar 1:4 (1 cement : 4 coarse sand)
13.88 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.88.1 1 mm thick
13.89 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required,to achieve even shade and colour. - 2 coats Windows’ Work (According to JKSSR 2022)
C- Ward No.3 1 SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=6000 W having Air Flow Rate >=590 cfm in Ward 3 with minimum 3 star and of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes . Nos. 12
SITC of 1.5 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 5200 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=5200 W having Air Flow Rate >=570 cfm in Ward 3 with minimum 3 star of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Wall mounted Copper wound stabilizer for 1.5 TR Air conditioners of capacity 4 KVA (voltage range 90 volts-300 volts) of reputed Make i.e. Electricfield/Servocon/Aulten/Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Heavy Duty Main Electrical Panel (Powder Coated) which includes MCCB 630A-4 Pole of breaking circuit capacity 50KA and of standard make i.e. Schneider and bus bar of required Size for 3 phases and neutral for connecting various ACs wires along with phase indicator and other allied accessories. The panel is to be installed on the roof and should be made weather-proof. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of extra FRLS PVC insulated 2.5 sq mm 4 core communication cable ISI Marked (using conduits and wire fasteners / cable clips/ conduit fasteners) of reputed make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning indoor unit to the installed air conditioning outdoor units, as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
Providing and fitting of MCB 40 Amp for 2.0 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box (complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges .
Providing and fitting of MCB 32Amp for 1.5 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box(complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc. with Insulation. Complete job must be as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying (with clamps/supports wherever required as per site conditions) of 185mm² 3.5 Core Aluminum armoured cable from main electric source (Transformer) to installed electric Panel. Complete job as per site requirement and as per instructions of Engineer-in-charge and also includes cost of material, labour, GST rates, Transportation, installation and all other charges and taxes.
Windows’ Work (According to JKSSR 2022 15.13 Taking out doors, windows and clerestory window shutters (steel or wood)including stacking within 50 meters lead : 15.13.1 Of area of 3 sqm. and below
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.1 For fixed portion 22.1.1.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) 22.1.2.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.3 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item.) 22.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
9.72 Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges (heavy weight) with Stainless Steel screws etc. complete. 9.72.3 75x50x2.50 mm
9.99 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 9.99.5 100x10 mm
9.102 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.102.2 100 mm
9.104 Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
14.1 Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead 14.1.2 With cement mortar 1:4 (1 cement : 4 coarse sand)
13.88 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.88.1 1 mm thick
13.89 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required,to achieve even shade and colour.- 2 coatsWindows’ Work (According to JKSSR 2022)
D- Ward No.16 1 SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=6000 W having Air Flow Rate >=590 cfm in Ward 16 with minimum 3 star and of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of 1.5 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 5200 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=5200 W having Air Flow Rate >=570 cfm in Ward 16 with minimum 3 star of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Wall mounted Copper wound stabilizer for 02 TR Air conditioners of capacity 5 KVA (voltage range 90 volts-300 volts ) of reputed Make i.e. Electricfield/Servocon/Aulten/ Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Wall mounted Copper wound stabilizer for 1.5 TR Air conditioners of capacity 4 KVA (voltage range 90 volts-300 volts) of reputed Make i.e. Electricfield/Servocon/Aulten/Microtek only along with allied accessories. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
SITC of Heavy Duty Main Electrical Panel (Powder Coated) which includes MCCB 630A-4 Pole of breaking circuit capacity 50KA and of standard make i.e. Schneider and bus bar of required Size for 3 phases and neutral for connecting various ACs wires along with phase indicator and other allied accessories. The panel is to be installed on the roof and should be made weather-proof. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting multiple air conditioning units to the electrical panel to be installed. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of extra FRLS PVC insulated 2.5 sq mm 4 core communication cable ISI Marked (using conduits and wire fasteners / cable clips/ conduit fasteners) of reputed make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning indoor unit to the installed air conditioning outdoor units, as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes .
Providing and fitting of MCB 40 Amp for 2.0 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box (complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges .
Providing and fitting of MCB 32Amp for 1.5 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only with gang box(complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc. with Insulation. Complete job must be as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes.
Providing and laying (with clamps/supports wherever required as per site conditions) of 185mm² 3.5 Core Aluminum armoured cable from main electric source (Transformer) to installed electric Panel. Complete job as per site requirement and as per instructions of Engineer-in-charge and also includes cost of material, labour, GST rates, Transportation, installation and all other charges and taxes.
Windows’ Work (According to JKSSR 2022) 15.13 Taking out doors, windows and clerestory window shutters (steel or wood)including stacking within 50 meters lead : 15.13.1 Of area of 3 sqm. and below
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.1 For fixed portion 22.1.1.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.1 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) 22.1.2.2 Powder coated aluminum (minimum thickness of powder coated 50 microns)
22.3 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item.) 22.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
9.72 Providing and fixing ISI: 12817 marked Stainless Steel Butt Hinges (heavy weight) with Stainless Steel screws etc. complete.9.72.3 75x50x2.50 mm
9.99 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :9.99.5 100x10 mm
9.102 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.9.102.2 100 mm
9.104 Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
14.1 Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead 14.1.2 With cement mortar 1:4 (1 cement : 4 coarse sand)
13.88 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.13.88.1 1 mm thick
13.89 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever requiredto achieve even shade and colour.- 2 coats Windows’ Work (According to JKSSR 2022)
E. WARD NO. 20 AIR HANDLING UNIT FAN (MAKE :KRUGER , NIKOTRA GRAMBERT ) 5000 CFM / 90 mm static pressure as per scope of work TECHNICAL SPECIFICATION/ SCOPE OF WORK at serail no. 57
CONDENSING UNIT :( MAKE : BLUESTAR, DAIKIN, HITACHI ) CONDENSING UNIT : Condensing unit for AHU with Accessories-All controls,expansion device & Filters, system with installation 8.5 TR
CONDENSING UNIT :( MAKE : BLUESTAR, DAIKIN, HITACHI ) CONDENSING UNIT : Condensing unit for AHU with Accessories-All controls,expansion device & Filters, system with installation 11 TR
Copper piping with 19 mm Black Nitrile Rubber Insulation and cable run on cable tray with proper fitting. Pipe size 1.1/8 " suction and 5/8" liquid line
ELECTRIC PANEL COMPONE NT MAKE :( SIEMENS , SCHNEIDER ) Design, Supply, Installation, Testing & Commissioning of Dedicated Power Panel (For AHUs) located near the AHU for HVAC system. The panel should consist of incomer MCCB with appropriate rating, starter with suitable O/L relay, ON/OFF push buttons & ON/OFF/TRIP indicating lamps with control circuitry as per system requirement. Panel with Variable Frequency Drive (VFD) For Control Motor Speed as per area required CFM and temperature controller. 45 KW
ELECTRICAL HEATER BANK for Heating 70 KW Heater with thyristor and heater wiring
ELECTRICAL WIRING (Finolex or Anchor or Polycabor Havells) 4.0 Sq mm cable for AHU motor
ELECTRICAL WIRING (Finolex or Anchor or Polycabor Havells) 4.0 sq mm cable for condensing unit
ELECTRICAL WIRING (Finolex or Anchor or Polycabor Havells) Controlling cable for AHU start and stop
ELECTRICAL WIRING (Finolex or Anchor or Polycabor Havells) Cable tray (16 swgG.I. with all allied accessories/fittings)
DUCTING AND INSULATION (JINDAL ,ESSAR ) GI duct - Site fabricated / Pre-Fabricated duct suitable for 4" wg duct pressure and construction as per SMACNA standard, with 120 GSM Zinc coating thickness as per Class VIII, with M.S. Powder coated/ Epoxy painted flanges, GI threaded Rod,Aluminum rivets ,food grade silicon sealant at all joints and seams, GI nut bolts, neoprene gasket of minimum 5mm thickness and GI non slotted Black Painted angle support to hang the duct. Duct Leakage test shall be performed with Fogger machine generated fog . 24 SWG gauge GI duct for OT
Thermal insulation of SA ducting externally with X mm thick O Class Insulation with adhesive butting the joints together as under for various locations with top surface finished as under 19 mm Nitrile Insulation for supply duct
SUPPLY AND RETURN AIR DIFFUSER / GRILL Aluminum powder coated supply and return air Grill/ Diffuser Diffuser (size 450 mmx450 mm approx.)
CIVIL WORK and other miscellaneous
Providing and laying (with clamps/supports wherever required as per site conditions) of 240 mm² 3.5 Core Aluminum armoured cable from main electric source (Transformer) to installed electric Panel. Complete job as per site requirement and as per instructions of Engineer-in-charge and also includes cost of material, labour, GST rates, Transportation, installation and all other charges and taxes.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .