Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹4.0 L+₹1,375 (0.34%)Rejected-AOC | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹4.1 L+₹3,775 (0.94%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹4.1 L+₹4,937 (1.23%)Rejected-Finance KALIKAPUR MATHPARA BOLPUR BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | L4 | Rejected-Finance Being L4 Bidder |
| Sl No | Description | Qty | Unit | PAL ELECTRICAL L4 | M/S SWAPAN KUMAR CHOWDHURY L3 | M/S. S. D. CHATTERJEE AND CO. L2 | NIRMAN ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|
| 4.00 | Dismantling of 440 Volt, 4 TR tower type AC machine both indoor and outdoor unit with suction and liquid line in proper process and deposit it to the sectional store in well manner. | 6 | nos | 2,377 ₹14,262 | 2,375 ₹14,250 | 2,372 ₹14,232 Lowest | 2,390 ₹14,340 |
| 5.00 | Dismantling of 230 Volt, 1.5 TR window type AC machine in proper process and deposit it to the sectional store in well manner. | 3 | nos | 1,076 ₹3,228 | 1,074 ₹3,222 | 1,071 ₹3,213 | 1,069 ₹3,207 Lowest |
| 6.00 | Dismantling of 230 Volt, 1.5 TR split type AC machine (Both indoor and outdoor) with proper process . | 1 | nos | 1,187 ₹1,187 | 1,185 ₹1,185 | 1,182 ₹1,182 | 1,180 ₹1,180 Lowest |
| 7.00 | Servicing and Overhauling of 440 Volt, 4 TR tower type AC machine (Both indoor and outdoor unit ) with proper tools and trackles. | 6 | nos | 3,564 ₹21,384 | 3,562 ₹21,372 | 3,559 ₹21,354 | 3,557 ₹21,342 Lowest |
| 8.00 | Reinstallation of 440 volt,4 TR tower type AC machine both indoor and outdoor unit with proper tool and trackles and mending good the damages. | 6 | nos | 5,346 ₹32,076 | 5,344 ₹32,064 | 5,341 ₹32,046 | 5,339 ₹32,034 Lowest |
| 9.00 | Reinstallation of 230 volt, 1.5 TR split type AC machine both indoor and outdoor unit with proper tool and trackles and mending good the damages. | 1 | nos | 2,927 ₹2,927 | 2,925 ₹2,925 | 2,922 ₹2,922 | 2,920 ₹2,920 Lowest |
| 10.00 | S&F 15.88mm & 6.35mm copper pipe (Make-Godrej/Totaline/Raiku) with nitrallile rubber (Make-Suprime) insulation & 3core 2.5Sqmm&4 core 1.55qmm copper un aurmored cable (Make-Finolex or KEI). | 9 | Mtr | 960 ₹8,640 | 958 ₹8,622 | 955 ₹8,595 | 953 ₹8,577 Lowest |
| 11.00 | Supply,Installation & Commissioning of Copper Refrigeration pipe line for liquid and suction line with shaddles and zip tie.Liquid Line (3/8" Outer Dia HD Copper Pipe with 0.6 mm thick) (Make-Godrej/ Totaline/ Raiku)
Liquid Line (3/8" Outer Dia HD Copper Pipe with 0.6 mm thick) (Make-Godrej/ Totaline/ Raiku) | 85 | mtr | 290 ₹24,650 | 288 ₹24,480 | 285 ₹24,225 | 283 ₹24,055 Lowest |
| 12.00 | Suction Line (5/8" Outer Dia HD Copper Pipe with 1 mm thick) (Make-Godrej/ Totaline/ Raiku) | 85 | mtr | 918 ₹78,030 | 916 ₹77,860 | 913 ₹77,605 | 911 ₹77,435 Lowest |
| 13.00 | Supply & Fixing pipe insulation in suction & Liquid line with 9 mm nitrile rubber tube for concealed Split AC.
Liquid Line | 85 | mtr | 95 ₹8,075 | 93 ₹7,905 | 90 ₹7,650 | 88 ₹7,480 Lowest |
Tender Value
Refer Docs
EMD Value
₹8,155
Closing Date
29 Aug 2023, 12:55 pmClosed
Executive Engineer,PWD
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Dismantling and reinstallation of 4 TR, 3 Ph Tower type AC machine and 1 Ph,1.5 TR Split type AC machine in OT and blood bank at Bolpur SD Hospital, Birbhum.
2023_WBPWD_558875_1
BIRED/39/e-NIQ (1st call) of 2023-2024
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Bolpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹8,155
O/O The Exe Eng, Birbhum Elec Divn
7 Jul 2026
22 Aug 2023
1 Sept 2023
22 Aug 2023
29 Aug 2023
24 Aug 2023
24 Aug 2023
Amount
Dismantling of 440 Volt, 4 TR tower type AC machine both indoor and outdoor unit with suction and liquid line in proper process and deposit it to the sectional store in well manner.
Dismantling of 230 Volt, 1.5 TR window type AC machine in proper process and deposit it to the sectional store in well manner.
Dismantling of 230 Volt, 1.5 TR split type AC machine (Both indoor and outdoor) with proper process .
Servicing and Overhauling of 440 Volt, 4 TR tower type AC machine (Both indoor and outdoor unit ) with proper tools and trackles.
Reinstallation of 440 volt,4 TR tower type AC machine both indoor and outdoor unit with proper tool and trackles and mending good the damages.
Reinstallation of 230 volt, 1.5 TR split type AC machine both indoor and outdoor unit with proper tool and trackles and mending good the damages.
S&F 15.88mm & 6.35mm copper pipe (Make-Godrej/Totaline/Raiku) with nitrallile rubber (Make-Suprime) insulation & 3core 2.5Sqmm&4 core 1.55qmm copper un aurmored cable (Make-Finolex or KEI).
Supply,Installation & Commissioning of Copper Refrigeration pipe line for liquid and suction line with shaddles and zip tie.Liquid Line (3/8" Outer Dia HD Copper Pipe with 0.6 mm thick) (Make-Godrej/ Totaline/ Raiku) Liquid Line (3/8" Outer Dia HD Copper Pipe with 0.6 mm thick) (Make-Godrej/ Totaline/ Raiku)
Suction Line (5/8" Outer Dia HD Copper Pipe with 1 mm thick) (Make-Godrej/ Totaline/ Raiku)
Supply & Fixing pipe insulation in suction & Liquid line with 9 mm nitrile rubber tube for concealed Split AC. Liquid Line
Suction Line
S & F 15mm PVC flexible drain pipe.
Supply and Charging of R410 A gas in existing copper pipe line.
Control copper cabling from ODU Unit to IDU unit of ductable Split AC. 4 Core 1.5 Sqmm unarmoured Cable.(Make-KEI/Gloster/Polycab)
3 Core 4 Sqmm unarmoured Cable.(Make- Gloster/Polycab/KEI)
Supply and Laying of 25 mm dia PVC pipe (Make-Oriplast/ Supreme) by using 15 nos 25mm dia socket, 22 nos 25 mm dia elbow, jointing by solvent cement/ adhesive and mending good the damages. (use for laying of two nos cable inside the pipe situated in outside)
Supplying and fixing of PVC Junction box (Make-Syntex (size-250mm X 250 mm X 160 mm)) consist of din rail by GI nut and bolt on outdoor iron angle.
Supplying and Fixing of 415 Volt MCB Isolator on din rail of existing DB and necessary connection. (Make-Legrand) a) 4 Pole 32 Amp. (D-5/ 6)
Supplying and Fixing of 415 Volt 32 Amp 4 way terminal.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 4 Sqmm
Supply and Installation of 4 TR tower type outdoor PCB board. (Make-Mitsubishi Heavy)
Reinstallation of existing outdoor structure by 6:3:1 cement concrete (4 nos) and 5 inch X 5 inch and 8 mm thickness MS plate welded in each stand, and 16 nos fast nut in each structure that firmly hold on the roof. S & F the corrogated sheet (Make-TATA) (Size-6 ftX 6ft) by suficient nut,bolt and screw. Painting it by one coat RO primer and two coat Synthetic paint (ISI approved) As per direction of EIC.
Febrication of 4 TR tower type AC machine indoor stand by 35mm * 35 mm * 5mm iron angle of 2 ft length and 1'1" breath with 4 nos 8" stand, use two nos 1'1" length 25 mm * 5 mm iron flat for middle support. Painting it by one coat RO primer and two coat Synthetic paint (ISI approved) As per direction of EIC.
Note:- Labour welfare Cess @ 1% and GST @ 18% on Bill amount will be deduct.
M/S. S. D. CHATTERJEE AND CO.
M/S SWAPAN KUMAR CHOWDHURY
PAL ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .