Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical qualified |
| 2 | Accepted-Technical | Accepted-Technical qualified |
| 3 | Accepted-Technical | Accepted-Technical qualified |
| 4 | Not Admitted-Fee/PreQual/Technical 26 AMBIKAPURI OPPS BSF WATERTANK AIRPORT ROAD INDORE M P 452005 | INDORE | MADHYA PRADESH | 452005 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.6 Cr
EMD Value
₹5.1 L
Closing Date
22 May 2026, 3:00 pmClosed
REGIONAL MANAGER RO BHOPAL
75 ARERA HILLS OPPOSITE KENDRIYA VIDYALAYA NO 1 BHOPAL MADHYA PRADESH 462011
Execution of Miscellaneous Repair Maintenance upgradation and Construction works in Zone 1 a cluster of Central Warehouses Bhopal I Year 2026 27 On Annual rate
2026_CWC_277008_1
E NIT_CWC/RO BPL/Engg./ZMC/26-27/02
Open Tender
Construction Works
365 days
BHOPAL MADHYA PRADESH
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹0
₹5.1 L
29 May 2026
8 May 2026
23 May 2026
8 May 2026
22 May 2026
8 May 2026
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1:1%:3 (1 cement : VA coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases for columns
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Columns, piers, abutments, pillars, posts and struts
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to foor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete.
Walls any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Weather shade, Chajjas, corbels etc., including edges
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
Mild steel and Medium Tensile steel bars
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with local sand, with common burnt clay non modular bricks.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
metre
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
metre
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
metre
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Shoe (Plain)
12 mm cement plaster of mix :
15 mm cement plaster on the rough side of single or half brick wall of mix :
6 mm cement plaster of mix :
Neat cement punning.
Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand):
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand):
White washing with lime to give an even shade :
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Finishing walls with water proofing cement paint of required shade :
Finishing walls with Acrylic Smooth exterior paint of required shade :
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
Applying priming coat:
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On steel work
On concrete work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
One coat
Two coats
White washing with lime to give an even shade :
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
DSR Civil 2023
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking.
Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brand.
Providing round the clock security guard with gun for watch & ward of Government premises and its all belongings by deploying neatly dressed security guards in 8 hour's shift including necessary T&P like torch, lathi and uniform etc.complete, as per the direction of Engineer-in-charge.(One job means 8 hour's duty).
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
G.S. Sheet
Asbestos Cement sheet
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road rollerincluding making good the undulations etc. and re-rolling the subgrade and disposal of surplus earthwith lead upto 50 metres.
Supplying and stacking at site.
90 mm to 45 mm size stone aggregate
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Stone screening 13.2 mm nominal size (Type A)
Stone screening 11.2 mm nominal size (Type B)
Good earth
Moorum
Laying, spreading and compacting stone aggregate of specified sizesto WBM specifications in uniform thickness, hand picking, rollingwith 3 wheeled road/vibratory roller 8-10 tonne capacity in stages toproper grade and camber, applying and brooming requisite type ofscreening / binding material to fill up interstices of coarse aggregate,watering and compacting to the required density .
Scarifying metalled (water-bound) road surface including disposal of rubbish, lead upto 50 m and consolidation of the aggregate received from scarifying with power road roller of 8 to 10 tonne capacity.
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
Cutting road and making good the same including supply of extraquantities of materials i.e. aggregate, moorum screening, red bajriand labour required.
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.New work (Two or more coats)
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.
Providing and fixing Glow studs of size 100x20 mm made of heavyduty body shall be moulded ASA (Acrylic styrene Acryloretrite ) orHIP (High impact polystyrene) or ABS having electronically weldedmicro- prismatic lens with abrasion resistant coating as approved byEngineer in charge. The glow stud shall support a load of 13635 kgtested in accordance with ASTM D4280. The slope of retro- reflectivesurface shall be 35 (+/-5) degress to base .The reflective panels onboth sides with at least 12 cm of reflective area up each side. Theluminance intensity should be as per the specification and shall betested as described in ASTM I: 809 as recommended in BS: 873part 4 : 1973. The studs shall be fixed to the Road surface using theadhesive conforming to IS, as per procedure recommended by themanufacturer complete and as per direction of Engineer-in-charge.
Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied withG.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per directionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately)
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signage
Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
DSR Civil 2023
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:
Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required :
Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require:
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to Eureopean type W.C. ofquality and make as approved by Engineer - in - charge.
DSR Civil 2023
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls
15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
DSR Civil 2023
Providing and fxing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fxing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing & fixing expanded metal mesh frame with expanded metal 20x60 mm strands 3.25 mm wide and 1.6 mm thick, and frame made of 25x4 mm M.S. flat sub divided into three equal panels with 25x4 mm M.S. Flat expanded metal to be fixed with 19x3mm M.S. Beading tack welded, 4 nos. of M.S. Cleats of size 50x50x4 mm size with holes for 12 mm dia. bolt i/c and manufacture and priming coat of approved steel primer complete as per drg. No.CWC/PG/414-AC and as per instructions of Engineer- in- charge. The whole frame with expanded metal mesh is to be fixed on the outer side of V4 openings with required size of fasteners 10x80 mm size
Supplying & fixing fire buckets
Providing and spreading non-metallic floor hardener minimum @ 4.5kg/sqm in floor concrete (as per manufactures specifications and approved by Engineer-in-charge). Nothing extra shall be payable if manufacturer specifies extra quantity.
Providing and fixing channels for preparing panels of required size and then dewatering of the concrete with vaccum dewatering machine finishing with mechanical trowel with trimix matching (thickness of flooring 75 to 150 mm, along with cutting groove joints at appropriate spacing as per direction of engineer in charge (concrete and steel to be paid separately as per relevent item)
Pluging of roof leakage in AC sheets by a cold applied bituminous caulking compound with mineral fillers in a volatile solvent to retain its plasticity as a selaing material of make shalimar/ sika or equivalnet of good quality . Complete work as per direction of official in charge. Complete compartment roof area to be measured.
Providing and fixing colour coated galvalume profile sheets (Make- TATA/JSW) with the depth of 30 mm and pitch of corrugation 200 mm (Colour and shape of profile as approved by the Engineer-in-charge), 0.60 mm(TCT) total coated thickness( tolerance as per relevant IS code), material yield strength 550 MPa, galvalume AZ-150 GSM (both side inclusive) with regular modified polyester paint and coating of 20-25 micron RMP on exposed surface including primer and 7-10 micron epoxy coating on unexposed surface including primer. The sheet should be supplied in single length as shown in drawing or as desired by engineer in charge and shall be fixed using stainless steel Hex cap headed self drilling/ tapping stainless steel screws M6, 50 mm long with 3 mm thick EPDM seal and Stainless steel stitching screw of size 19X2.5 mm excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. All screw should be sealed with silicon sealant.
Providing and fixing colour coated galvalume sheets roofing accessories (Make- TATA/JSW), 0.60 mm total coated thickness (TCT), material yield strength 550 MPa, galvalume AZ-150 GSM (both side inclusive) with regular modified polester paint and coating of 20-25 micron rmp on expose surface including primer and 7-10 micron epoxy coating on unexposed surface including primer using stainless steel self drilling/ tapping screws of size 6x50 mm with 3 mm thick EPDM seal and Stainless steel plain washer complete : Matching Profile ridge (500 - 600mm).
Complete servicing including Lubricating of old rolling shutters with grease and other suitable lubricating items to make rolling shutter in working condition all work complete as per direction of official in charge
Repair / Refilling gap between roof sheet and walls with cement concrete 1:1.5:3 ( 1 cement: 1.5 Coarse sand (Zone III), 3 graded stone aggregate 20 mm nominal size) and finishing/ leveling with avg 6 mm thick cement plaster both side of mix 1:3 ( 1 cement : 3 fine sand ) to match with existing wall plaster i/c scaffolding and all lead and lift complete as per direction of Engineer -in-charge.(avg thickness of CC 50 mm)
Labour for refixing of dismantled barbed wire or flexible wire rope in fencing.
Plugging of roof leakages in polycoated sheet roof by providing silicon sealant around bolts
Pluging of roof leakage by self adhesive tear resistant (Bituminous sealing tape, used for a wide range of waterproofing work on roofs, building components, caravans ) plugging tape/ Mastic tape of sika multiseal/ shalimar or equivalent of approved make (minimum width 100 mm) after cleaning the dirt/ sheet complete for proper fixing of tape as per direction of official in charge. Rate includes cost of all material and labour required for plugging of roof leakage. complete work as per direction of official in charge
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within: Polycarbonate sheet
Densification & Polishing: Providing Hardening, dust proofing, abrasion Resistant and sealing treatment over concrete Flooring including cleaning & drying the base surface, applying ready to use Euco Diamond Hard Euclide chamical USA/Densi Hard /Master Hard/Lizo c/Concast Densi Hard Cure Hard 24 (Sika India) 2-3 COATS . all as per manufcturer's recommendations and as directed by the engineer . Note:-Polising diamond Grits to be use 60 no, or 100 no (as per floor requirment), then 200 no, 400 no,800 no, 1500 no, and final Polish with 3000 no Diamond Grits for Semi Glossy Look.
Providing asbestos cement 6mm thick corrugated steets roofing and fixing with G.I.J. or L Hooks, bolts and nuts 8mm dia G.I.plan and bitumen washers complete (Excluding cost of purlins,rafters and trusses) corrugated sheets upto 60 pitch. With one and half corrugations overlaps
Supplying & Laying saturated felt type 3 grade-I (Hessain base) on top of AC Ridges with suitable blows type petroleum bitumen of penetration of IS grade 85/25 of approved quality by apply 1.45 Kg. per Sqm. (The hessain type tarfelt should be of approved quality and conform to IS 1322)
Manufacturing/ Providing and laying precast inter locking cement concrete paver blocks of grade M-40 and size 200mm X 100mm X 100 mm including providing and laying 50 to 80mm (avg 65 mm) thick layer of bedding sand, joint filling with fine sand, compacting with plate compactor and final compaction with vibratory roller etc. as per specification. The item includes all cost of paver blocks i.e., cost of ingredients of paver blocks such as sand, aggregate, cement of high strength OPC cement as per IS 8112-2013, cost of bedding as well as sand filled in joints. The rate shall also include all lead, lifts, materials, machine tools, plants, labour, equipment & testing etc. complete in all respects as directed by Enineer - in - Charge
Providing and Fixing at or near ground level precast cement concrete saucer drain of grade M-30
Dismantling & refixing A.C. sheets in roofing with G.I.J. or L hooks bitumen and G.I. plain washers complete as directed by Engineer-in-Charge (A.C. Sheets required for the work shall be used out of dismantled serviceable assets) shall be supplied free of cost.)
Labour for Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supply & installation of steel porta cabin of size 12'X4'X8'6'' for toilets with 2 no's of Water closet and wash basins,3 nos exhaust fans, 2 Urinals and accessories for ladies, common and gents washroom with 3 seperate entrances ,cabin with a 75mm x 75mm C-channel base, supported by a 50mm x 50mm square pipe cross member and 25mm x 25mm square pipe. It includes an 18mm fiber cement board and 1mm thick vinyl flooring. The roof, designed in a double-slope hut shape, comprises a 1.2mm MS plain sheet welded to a frame, adorned with 4mm ACP board on the inner side. The cage structure utilizes an MS framework with 50mm thick wall panels, featuring 4mm ACP board on the inner wall and 1.2mm MS sheet on the exterior. Insulation is provided by 50mm thick glass wool, enhancing thermal performance and moisture resistance. Access is through a door with a 30mm x 30mm square pipe frame, clad in MS sheet and ACP board, featuring a secure locking system. Plumbing includes a latched bath area equipped with an EWC, hand wash basin, and soap tray, using CPVC piping and ISI-standard sanitary fittings. the rate should be inclusive of all taxes and charges for making of the cabin with doors, windows, septic tank ,water tank and basic amneties, transporting, installing and electical fixures(modular switches,exhaust fan, inside and bulkhead light etc) and fittings of required plugging points & sockets of 10/5 amps at specified site/platform with painting and rubber paint on top etc complete as per the specification & directions of EIC.
Providing and applying high performance EPU Flooring of JEMKON Make of thickness on concrete surface, which includes surface preparation thoroughly by grinding & cleaning all dirt, debris to achieve a sound surface, followed by a primer coat with Tech 24 of 0.1 MM by mixing base and hardener (as per manufacturer’s specification). It will be followed by a screed coat with Tech 60 of 2 MM by mixing base & hardener & aggregates (as per manufacturer’s specification) followed by a sealer coat and application of Final Top coat with Tech SLE of 0.9 MM by mixing base ,hardener , color paste & aggregates (as per manufacturer’s specification) complete as per specifications and as directed by Engineer-In-Charge. Total thickness will be 3 MM.
Providing and applying high performance PU Concrete Flooring of JEMKON/ sika / equivalnet make of 3mm thick on concrete surface, which includes surface preparation thoroughly by scarification, Groove cutting & cleaning all dirt, debris to achieve a sound surface. Application of scratch coat of 1 mm and followed by application of Final Top coat with Tuffkrete of 2mm by mixing base , hardener , colour paste & aggregates (as per manufacturer’s specification) complete as per specifications and as directed by Engineer-In-Charge. Total thickness will be 3mm.
RR masonry in superstructure above plinth level and upto floor five level, including leveling up with CC 1:6:12 at window sills, ceiling level and the like - Cement mortar 1:6 (1 cement : 6 coarse sand).
Description of Item
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group A
Group B
Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
4 x 1.5 sq. mm
5 x 1.5 sq. mm
6 x 1.5 sq. mm
7 x 1.5 sq. mm
8 x 1.5 sq. mm
9 x 1.5 sq. mm
10 x 1.5 sq.mm
2 x 2.5 sq. mm
3 x 2.5 sq. mm
4 x 2.5 sq. mm
5 x 2.5 sq. mm
6 x 2.5 sq. mm
7 x 2.5 sq. mm
8 x 2.5 sq. mm
9 x 2.5 sq. mm
10 x 2.5 sq. mm
2 x 4 sq. mm
3 x 4 sq. mm
4 x 4 sq. mm
5 x 4 sq. mm
6 x 4 sq. mm
7 x 4 sq. mm
8 x 4 sq. mm
9 x 4 sq. mm
10 x 4 sq. mm
2 x 6 sq. mm
3 x 6 sq. mm
4 x 6 sq. mm
5 x 6 sq. mm
6 x 6 sq. mm
7 x 6 sq. mm
8 x 6 sq. mm
9 x 6 sq. mm
10 x 6 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100 A, 16 KA,TPMCCB
125 A, 16 KA,TPMCCB
150 A, 16 KA,TPMCCB
200 A, 16 KA,TPMCCB
200 A, 25 KA,TPMCCB
250 A, 25 KA,TPMCCB
250 A, 35 KA,TPMCCB
315 A, 35 KA,TPMCCB
400 A, 35 KA,TPMCCB
500 A, 35 KA,TPMCCB
630 A, 50 KA,TPMCCB
800 A, 50 KA,TPMCCB
100 A,30KA,FPMCCB
125 A,36KA,FPMCCB
200 A,36KA,FPMCCB
250 A,36KA,FPMCCB
250 A,50KA,FPMCCB
400 A,50KA,FPMCCB
630 A,50KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
8 way , Double door
12 way , Double door
16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
900mm, service value = 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum)
1050mm, service value = 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
1200mm, service value = 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1400mm, service value = 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
900mm, service value = 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum)
1050mm, service value = 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum)
1200mm, service value = 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1400mm, service value = 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supply and testing of LED well glass fixture with following wattage rating and as per technical specifications attached, OEM Warranty of 05 years, including accessories for support on wall, bracket, truss, or suitable hanging arrangement upto 1 meters, and 1 meter FR PVC insulated copper conductor flexible cable of size 1.5 sq. mm, complete as per instructions of official-in-charge.
Supply & testing of XLPE insulated copper conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment. and as per instructions of official-in-charge.
3 x 4.0 sq. mm
3 x 6.0 sq. mm
3 x 10 sq. mm
4 x 6.0 sq. mm
4 x 10 sq. mm
Supply & testing of XLPE insulated copper conductor unarmoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.
3 x 4.0 sq. mm
3 x 6.0 sq. mm
3 x 10 sq. mm
4 x 6.0 sq. mm
4 x 10 sq. mm
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.
2 x 10 sq. mm
3 x 10 sq. mm
3 X 16 sq. mm
3 X 25 sq. mm
3 X 35 sq. mm
3 X 50 sq. mm
3 X 70 sq. mm
3 X 95 sq. mm
3 X 120 sq. mm
3 X 150 sq. mm
3 X 185 sq. mm
3 X 240 sq. mm
3 X 300 sq. mm
3.5 X 25 sq. mm
3.5 X 35 sq. mm
3.5 X 50 sq. mm
3.5 X 70 sq. mm
3.5 X 95 sq. mm
3.5 X 120 sq. mm
3.5 X 150 sq. mm
3.5 X 185 sq. mm
3.5 X 240 sq. mm
3.5 X 300 sq. mm
3.5 X 400 sq. mm
4 x 10 sq. mm
4 X 16 sq. mm
4 X 25 sq. mm
4 X 35 sq. mm
4 X 50 sq. mm
Supply & testing of XLPE insulated aluminium conductor unarmoured power cable of 1.1 KV grade confirming to IS : 7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.
2 x 6 sq. mm
2 x 10 sq. mm
3 X 16 sq. mm
3 X 25 sq. mm
3 X 35 sq. mm
3 X 50 sq. mm
3 X 70 sq. mm
3 X 95 sq. mm
3 X 120 sq. mm
3 X 150 sq. mm
3 X 185 sq. mm
3 X 240 sq. mm
3 X 300 sq. mm
3.5 X 25 sq. mm
3.5 X 35 sq. mm
3.5 X 50 sq. mm
3.5 X 70 sq. mm
3.5 X 95 sq. mm
3.5 X 120 sq. mm
3.5 X 150 sq. mm
3.5 X 185 sq. mm
3.5 X 240 sq. mm
3.5 X 300 sq. mm
3.5 X 400 sq. mm
4 X 16 sq. mm
4 X 25 sq. mm
4 X 35 sq. mm
4 X 50 sq. mm
Supply and fixing of 20 mm dia flexible corrugated metal/GI conduit as required.
Supply & Testing of 3 core 2.5 sq.mm FRLS PVC insulated multicore Unsheathed Industrial Flexible Cable conforming to IS 694: 2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts. as per the instructions of the engineer incharge
Supply & testing of 2 core 2.5 sq.mm FRLS PVC Insulated Multi core Unsheathed Industrial Flexible Cable conforming to IS 694: 2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts. as per the instructions of the engineer incharge
Supply & testing of 3 core 4 sq. mm Flat Cable for submersible pump motors FRLS PVC insulated single core Unsheathed Industrial Flexible Cable conforming to IS 694: 2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts. as per the instructions of the engineer incharge
Attending to breakdown calls including identification, isolation, correction of fault, followed by restoration of circuit supply complete as required as per the instructions of Officer-in-charge.
Low impact category (as decided by Officer-in-charge)
Medium Impact category (as decided by Officer-in-charge)
High Impact category (as decided by Officer-in-charge)
Supplying and fixing following 40 /63 Ampere rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of official in charge
Triple pole
Triple pole and neutral
Supply, installation, testing & commissioning of LED Based signage board of required size, made of aluminium composite panel sheet of 3 mm thickness duly framed on 25 mm x 25 mm M.S. Square Pipe, duly computerized CNC cutting, display by using 3 mm laser cut imported acrylic sheet as per the design in bilingual, with Samsung/ Oshram make LEDs, with warranty of 1 year on LED and SMPS, with installation at site complete as per direction of official in charge
Supply and fixing of SMC junction box of size 250 x 200 x 105 mm, waterproof, Fire retardant including of din bar, 6 amp single pole MCB, 4 way connector plate and making connections including installation on street light pole with MS D-Clamp with iron strip etc. complete in all respects as per direction of Officer-in-charge.
Supply and fixing of SMC junction box of size 140 x 140 x 95 mm, waterproof, Fire retardant including of 4 way connector plate and making connections including installation on street light pole with MS D-Clamp with iron strip etc. complete in all respects as per direction of Officer-in-charge.
Testing of earth pit resistance test using calibrated ground resistance meter and submission of report, complete as per instructions of Officer-in-charge.
Supply and fixing of 150 AH 12V tall tubular battery including 4 mm copper jumper wire of required lenth and terminals, completed as required.
Supply, installation, testing and commissioning of MV compartmentalized, modular design, double door electrical panel, suitable for 415 V, 3 phase, 50 Hz, 4 wire system, Sheet thickness not less than 2.00 mm for load bearing members and 1.60 mm for doors, with following ratings aluminium bus bars, free standing, totally enclosed, with following incoming and outgoing switches, meters, inter connections with suitable size aluminium cables / bars, complete with terminating arrangements, powder coating the panel using 7 tank treatement, earthing, with cable chamber, busbar chamber, bottom/top cable entry etc., as per below description and in conjunction with technical specifications suitable for incoming and outgoing bus bar trunking/cable termination complete as required. Base supports shall be of size 75x75x8 mm MS angle iron duly primered and enamel painted.
Main Distribution Panel Design 1
Main Distribution Panel Design 2
Feeder Panel
Description of item
Cleaning of garden, Watering of landscaped/green belt areas and maintaining the plants/ shrubs, trees, bushes, flowering beds etc and keeping these in healthy condition . Maintaining the greenery, hygienic and aesthetic in lawn & other green belt area within complex ,Trimming the branches of trees obstructing the height up to 6 m above the driveway or obstructing the visibility of road signs , trimming or weeding out of unsolicited plants grown over terrace/walls of building within complex . Maintenance of Kitchen garden or similar seasonal flower garden including preparation of beds manuring/ fertigation, weeding hoeing, watering, planting of vegitable seeds/seasonal flowering seeds including spraying of insecticide and pesticide and Harvesting. (Note:-Only Good Earth, Manure, Fertilizer, Insecticide & Pesticide & saplings or seeds will be provided by the Department and other T & P material and machines shall be provided by the contractor). Frequency of cleaning shall be daily and watering or other activities shall be as per requirement . Payment shall be done on monthly basis . Area to be decided by WHM
Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forke and keeping the lawn free from weeds and fit for mowing including spreading of good earth/sludge etc as per requirement, mowing using lawn mowers and trimming of Damaged trees plants and bushes in Lawns or from any other garden within CW Complex at least once in 3 weeks and as per additional requirement. Payment shall be done at end of 6 months. Frequency: Once in 6 months in the area decided by WHM
Mixing earth and sludge or manure in the required proportion and spreading/ of sludge, dump manure and/or good earth in required thickness within complex as per requirement. Payment shall be done on monthly basis. Frequency: once a month
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant ) These includes new plants ,including seasonal flowering plants, shrubs, hedges etc. , shifting of plant from pots, Relocating the plants and /or Pots etc. within complex as per requirement by WHM, Cost of plant shall be paid extra. Payment shall be done after each work at monthly basis
Trees Plant
Shrubs Plant
Hedge Plant /Ground cover
Cutting of designer hedge/edge hoeing of hedge/edge bed Topiary cutting/shaping of plant removing of cut materials, cleaning, hoeing of plants, hoeing of trees (Topiary) watering manure and applying insecticides and fungicides etc. Payment shall be done at monthly basis. Frequency: Once in month in the area decided by WHM
Clearing heavy jungle in open area including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish upto secondary collection chamber .Payment shall be done after each work at monthly basis. frequency: once in 6 months and Area to be decided by WHM.
Clearing grass, shrubs, bushes grown unwanted near to buildings and roads and removal of the rubbish upto secondary collection chamber .Payment shall be done after each work at monthly basis. frequency: once in 3 months and Area to be decided by WHM.
Removal of garden waste by TATA 407 or equivalent including loading/ unloading and carriage including all lead and lift for complete disposal upto designated place given by ,Local authority and as per direction of officer-in-charge. Frequency: once in a week or as per requirement of WHM. Payment shall be done based on number of trips (fully loaded)
Cleaning/Sweeping of CW Roads, Main entry Ramps, Parking yards Godown Veranda/Open Platforms and Weighbridge platform area etc. including Safe disposal of garbage/ Refuse or solid waste, scraps after segregating Organic /recyclable and inorganic waste to the dustbins placed at designated disposal sites (secondary collection centres near Office/ Godown (s) and any other place within CW Complex.Frequency: Daily and Area to be decided by WHM and Total open area cleaned shall be measured for payment and Payment shall be done at monthly basis.
Cleaning, dusting, mopping of Window Glasses (both sides), floors, furnitures, etc. to make the area neat and clean free from cobwebs, flies etc , and hygeinic in Office buildings, labour Huts, Security Cabins,weighbridge cabin and other similar amenities within complex, including Safe disposal of garbage/ Refuse or solid waste, scraps after segregating Organic /recyclable and inorganic waste to the dustbins placed at designated disposal sites (secondary collection centres near Office/ Godown (s) and any other place within CW Complex.Frequency: Daily and total carpet area cleaned shall be measured for payment shall be done at monthly basis
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of WHM . (The old date written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account). Frequency: Once in 6 months. Payment shall be done after each work at monthly basis.
Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of WHM. Payment shall be done after each work at monthly basis.
Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of WHM. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of WHM. Frequency: once in 6 months, surface area of the tank shall be measured for payment. Payment shall be done after each work at monthly basis.
Each per day
Meter
E NIT_CWC/RO BPL/Engg./ZMC/26-27/02
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 1 – a cluster of Central Warehouses Bhopal-I ( Year 2026-27) On Annual rate Contract basis.
GCMXCM
Description of Work
Price Schedule: • Items mentioned at Sub Schedule A. (I): • Items based on DSR 2023 for civil works, • Non-Scheduled Market rate Items of Civil work.
E NIT_CWC/RO BPL/Engg./ZMC/26-27/02
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 1 – a cluster of Central Warehouses Bhopal-I ( Year 2026-27) On Annual rate Contract basis.
GCMXCM
Description of Work
Price Schedule: • Items mentioned at Sub Schedule A. (II) •Items based on DSR (E&M) 2025 for Electrical works • Non-Scheduled Market rate Items of E&M work.
E NIT_CWC/RO BPL/Engg./ZMC/26-27/02
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 1 – a cluster of Central Warehouses Bhopal-I ( Year 2026-27) On Annual rate Contract basis.
GCMXCM
Description of Work
Price Schedule: • Items mentioned at Sub Schedule A. (III) •Items for General Maintenance Works & Services consisting Horticulture works and House Keeping Services.
E NIT_CWC/RO BPL/Engg./ZMC/26-27/02
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 1 – a cluster of Central Warehouses Bhopal-I ( Year 2026-27) On Annual rate Contract basis.
GCMXCM
Total of Sub schedule A. (I)
Total of Sub schedule A. (II)
Total of Sub schedule A. (III)
Total of all Sub Schedules (I) + (II) + (III) {In Figures}
Total of all Sub Schedules (I) + (II) + (III) {In Words}
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
TENDERDOCZONE1BPL.pdf
Tender Documents • 5.69 MB
PriceBidZONE1.xls
Other Document • 0.24 MB
Download all tender documents and submit your bid