Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.8 LAccepted-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹72.0 L+₹2.0 L (2.87%)Rejected-Finance 88 30 RAMASAMY GARDEN ADYAR ARUNACHALAPURAM ADYAR CHENNAI TAMIL NADU 600020 | CHENNAI | TAMIL NADU | 600020 | L2 | Rejected-Finance Being a 2nd lowest bidder | |
| 3 | L3₹72.4 L+₹2.5 L (3.51%)Rejected-Finance NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-Finance Being a 3rd lowest bidder | |
| 4 | L4₹75.1 L+₹5.1 L (7.27%)Rejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L4 | Rejected-Finance Being a 3rd lowest bidder |
| Sl No | Description | Qty | Unit | G.L.THIRUMALAI NAIDU AND COMPANY L3 | Banyan Engineers and Contractors L4 | YOGAA MANPOWER AGENCY L2 | DJ Group L1 |
|---|---|---|---|---|---|---|---|
| 1.00B/R PORTION: | |||||||
| 1.01 | Demolition of cement concrete (unreinforced) of any description and in any position, sunken floor not otherwise specifically provided complete all as specified and directed | 29.1 | Cum | 540 ₹15,714 | 700 ₹20,370 | 500 ₹14,550 | 422 ₹12,280.2 Lowest |
| 2.00 | M&L for PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in padding on roof slab of required thickness for levelling the surface of roof slab, finished fair and even complete all as specified and directed. | 13.2 | Cum | 6,300 ₹83,160 | 5,500 ₹72,600 Lowest | 6,500 ₹85,800 | 6,000 ₹79,200 |
| 3.00 | M&L for complete removal of existing roof treatment of any description in patches viz. tarfelt or membrane surface or roof tiles etc. including grubbing up of tree roots and removing all the debris to a distance n.exc 100m and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc and applying the following roof treatment complete all as specified by Manufacture's instruction and as directed:-
(a) Applying Ist course of 15 mm thick cement screed in CM 1:4 over concrete surface including mixing with water proofing compound @ 200ml per bag of cement .
(b) Applying 2nd course of bituminious primer confirming to IS-3384 @ 0.4 litre /sqm over the screed bed.
(c) Applying 3rd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree and applied at the ate of @ 1.2 kg/sqm.
(d) Applying 4th course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per Manufactures instructions. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celicious and applied @ 1.2 kg/sqm over APP membrane,(f) Applying 6th course of a one coat of solar reflective aluminium paint @ 0.10 Litre / sqm on wall surfaces complete all as specified and directed. Note:- WPC shall be measured and paid separately. | 330 | Sqm | 630 ₹2,07,900 Lowest | 800 ₹2,64,000 | 850 ₹2,80,500 | 640 ₹2,11,200 |
| 4.00 | Taking down of existing the existing water proofing treatment on walls including cement /lime mortar rendering and clenaing the surface with water and applying 10 mm thick rendering in cement mortar 1:3 mixed with liquid ater proofing compound @ 200 ml per 50kg of cement , cleaning and preparation of newly plastered wall surfaces and applying the following water proofing treatment all as specified by Manufactuer's instruction and as directed (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 litre /sqm over the screed bed.
(b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celicious and applied @ 1.2 kg/sqm.
(c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per Manufacture's instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celeicious and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed. Note:- WPC shall be measured and paid separately. | 50 | Sqm | 540 ₹27,000 Lowest | 700 ₹35,000 | 850 ₹42,500 | 650 ₹32,500 |
| 5.00 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed by Engineer-in-charge | 5 | Quintal | 450 ₹2,250 | 500 ₹2,500 | 1,000 ₹5,000 | 320 ₹1,600 Lowest |
| 6.00 | Dismantling of PGI / CGI / Galvalume sheets of any description as in roof coverings | 138 | Sqm | 27 ₹3,726 | 100 ₹13,800 | 80 ₹11,040 | 13 ₹1,794 Lowest |
| 7.00 | S&F 0.50mm thick corrugated (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. | 138 | Sqm | 810 ₹1,11,780 | 775 ₹1,06,950 | 650 ₹89,700 Lowest | 790 ₹1,09,020 |
| 8.00 | S&F mild steel framed brackets of angles or tees with web and flanges cut toshape, drilled and countersunk for screw, including bending andwelding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290 Gde-E-165 complete all as specified and as directed | 500 | Kg | 135 ₹67,500 | 140 ₹70,000 | 110 ₹55,000 Lowest | 131 ₹65,500 |
| 9.00 | S&F Mild teel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running railsand guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B all as specified and as directed | 900 | Kg | 135 ₹1,21,500 | 140 ₹1,26,000 | 110 ₹99,000 Lowest | 131 ₹1,17,900 |
Tender Value
₹79.2 L
EMD Value
₹1.4 L
Closing Date
21 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Vishal Garg,IDSE,SE,SAG
CWE Chennai,Pallava Sallai Chennai-02
SPECIAL REPAIS TO BLDG NO P-XXIV AT IGOE UNDER GE CHENNAI
2025_MES_733439_1
88493/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE Chennai
As per Tender documents
7 documents required · 7 mandatory
₹1,000
GE Chennai
₹1.4 L
20 Feb 2026
30 Sept 2025
23 Oct 2025
30 Sept 2025
21 Oct 2025
14 Oct 2025
Amount
B/R PORTION:
Demolition of cement concrete (unreinforced) of any description and in any position, sunken floor not otherwise specifically provided complete all as specified and directed
M&L for PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in padding on roof slab of required thickness for levelling the surface of roof slab, finished fair and even complete all as specified and directed.
M&L for complete removal of existing roof treatment of any description in patches viz. tarfelt or membrane surface or roof tiles etc. including grubbing up of tree roots and removing all the debris to a distance n.exc 100m and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc and applying the following roof treatment complete all as specified by Manufacture's instruction and as directed:- (a) Applying Ist course of 15 mm thick cement screed in CM 1:4 over concrete surface including mixing with water proofing compound @ 200ml per bag of cement . (b) Applying 2nd course of bituminious primer confirming to IS-3384 @ 0.4 litre /sqm over the screed bed. (c) Applying 3rd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree and applied at the ate of @ 1.2 kg/sqm. (d) Applying 4th course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per Manufactures instructions. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celicious and applied @ 1.2 kg/sqm over APP membrane,(f) Applying 6th course of a one coat of solar reflective aluminium paint @ 0.10 Litre / sqm on wall surfaces complete all as specified and directed. Note:- WPC shall be measured and paid separately.
Taking down of existing the existing water proofing treatment on walls including cement /lime mortar rendering and clenaing the surface with water and applying 10 mm thick rendering in cement mortar 1:3 mixed with liquid ater proofing compound @ 200 ml per 50kg of cement , cleaning and preparation of newly plastered wall surfaces and applying the following water proofing treatment all as specified by Manufactuer's instruction and as directed (a) Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 litre /sqm over the screed bed. (b) Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celicious and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per Manufacture's instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celeicious and applied @ 1.2 kg/sqm over APP membrane, (e) Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed. Note:- WPC shall be measured and paid separately.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed by Engineer-in-charge
Dismantling of PGI / CGI / Galvalume sheets of any description as in roof coverings
S&F 0.50mm thick corrugated (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed.
S&F mild steel framed brackets of angles or tees with web and flanges cut toshape, drilled and countersunk for screw, including bending andwelding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290 Gde-E-165 complete all as specified and as directed
S&F Mild teel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running railsand guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B all as specified and as directed
M&L for cutting holes into or through brick / stone walls but in cement mortar of superficial area n.exc 150sqcm . and making good in cement mortar 1:3 or cement concrete 1:2:4 type Bl as required complete all as secified.
M&L for cutting chases, pinning in brick / stone wall not exceeding 10 cm girth for concealed water tubing or conduit wiring ,making good and pointing in cement mortar 1:3 complete all as specified and directed.
Supply and laying CPVC pipe SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete with all pipe fittings including taking up or down the existing pipe line of any description complete all as specified for following sizes :-
20mm outer dia bore
25mm outer dia bore
32mm outer dia bore
S&F in repairs vitreous china wash basin of oval counter foul type including fitting inside granite platform, including waste coupling, waste pipe and brackets etc complete all as specified and directed. Note: The RCC slab and granite platform shall be measured and paid separately under relevant item.
S&F in repairs 15mm dia Bib taps cast fancy type, chromium plated with crutch or butterfly handle, screwed for iron pipe or for brass ferrule for fancy type Chromimum plated complete all as specified and directed.Make:Jaquar
S&F in repairs two way bib tap 15 mm bore chromium plate with crtuch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union complete all as specified and directed. Make:Jaquar
S&F in repair 15mm dia CP bib cock nozzle with flange (washing machine tap) complete all as specified and as directed. Make:Jaquar
S&F in repairs 15 mm dia pillar tap mixer for both Hot and Cold long neck with aerator fancy type cast copper alloy with crutch handle screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe or for brass ferrule etc complete all as specified and as directed.Make:Jaquar
S&F in repair wall mixer 2-in-1 system with provision for over head shower complete all as specifed and directed.Make:Jaquar
S&F in repairs health faucet , hand shower with 1 metre flexible tube with wall hook chromium plated complete all as specified and directed.Make:Jaquar
S&F in repair angular stop cock 15 mm dia brass chromim plated fancy type with long shank, screwed down high pressure with crutch or butter fly handle screwed down both ends for iron pipe or for union complete all as specified and directed.Make:Jaquar
S&F in repair over head shower rose & shower arm with revolving joint of size 100mm dia round shaped single flow, ABS body chromium plated complete all as specified .Make:Jaquar
S&F in repair toilet paper holder with flap recessed type matt chromium plate complete all as specified .Make:Jaquar
S&F in repair soap dish, matt finished chromium plated (MCH /Colour CP) complete all as specified Make:Jaquar
S&F in repair corner glass shelf 300mm, matt finished, chromium plated (MCH/Colour CP) with bracket complete all as specified and directed.Make:Jaquar
S&F in repair towel ring round with round flange chromium plated complete all as specified Make:Jaquar
S&F in repairs towel rail 600mm long with flanges, chromium plated complete all as specified Make:Jaquar
S&F in repair cabinet mirror of size 330 mm X 430 mm with shelfs complete all as specified and directed.Make:Jaquar
S&F in repair tumbler holder chromium plated complete all as specified Make:Jaquar
S&F in repairs Sink made out of stainless steel 1mm thick with drainage board for kitchen and laboratory with plugs washers and wastes, including beading in cement mortar to dwarf wall including fixing cantilever brackets and connecting union to pipe overll size 915mmx460mm bowl size for 410mmx330mmx160mm including 40mm size CP waste coupling and PVC waste pipe complete all as speciifed .Make : NIRALI/JAYNA/DIAMOND/ PARRYWARE
S&F in repair 15 mm bore sink cock with swinging spout wall mounted model with wall flange complete all as specified and directed. Make:Jaquar
S&F in repairs 15mm PVC connection 450mm long of superior quality as specified.
S&F in repairs PVC waste pipe for wash hand basin of size 32mm dia , 800mm length complete all as speified and directed Make : Prayag
S&F in repairs PVC waste pipe for Sink waste pipe of size 38/40mm dia,1150mm length complete all as specified and directed Make : Prayag
S&F in repair CP cockroach trap (127mmx127mm) with waste hole/with out waste hole of Make Prayag all as specified and directed.
S&F in repair Stainless steel plate rack of size 24"X36"X10" fixed on wall with stainless screw with wooden plugs near the kitchen sink including all accessories and making good the disturbed wall tiles/concrete surface complete all as specified and directed.
S&F in repair Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 25 mm dia bore pipes
S&F in repairs rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position of 1000 litres capacity including 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
S&F in repairs PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified
S&F in repairs PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified
S&F in repairs PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified
S&F in repairs PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified
S&F in repairs PVC (SWR) bend with access door of any radius of 75mm dia
S&F in repairs PVC (SWR) bend with access door of any radius of 110mm dia
S&F in repairs PVC (SWR ) vent cowl of 110mm bore
S&F in repairs PVC (SWR ) vent cowl of 75mm bore
S&F in repairs PVC (SWR) branch piece, double Y equal or unequal 110mm bore with access door
S&F in repairs PVC (SWR) branch piece, double Y equal or unequal 75mm bore with access door
S&F in repairs PVC (SWR) junction double, double T equal or unequal 110 mm bore with access door
S&F in repairs PVC (SWR) junction double, double T equal or unequal 75 mm bore with access door
Dismantling floor, hearth or wall tiling including cement mortar bedding / existing backing coat and removing serviceable tile to store and rubbish off the premises complete all as specified .
M&L for Virified ceramic light coloured double charged tiles of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm of approved pattern as in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tile over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for Virified ceramic light coloured double charged tiles of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm of approved pattern on vertical surfaces of wall such as dado,skirting etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tile over and including backing coat in cement mortar 10mm thick 1:3 on fair faces of brick or concrete surfaces complete all as specified and as directed.
M&L for non skid ceramic coloured joint free tile 7mm to 8 mm thick concept tile, design as approved (sqaure or rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc over and including 15 mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile complete all as specified and as directed.
M&L for glazed coloured ceramic Concept designer tiles of 7mm thick and area exceeding 0.11 sqm and not exceeding 0.18 Sqm as approved by GE, fixed in vertical surfaces such as in dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness ,laid bedded and pointed in cement morter as in floors, platforms, aprons etc.complete all as specified.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement mixed with admixture of pigment to match the shade of granite stone including grinding and polishing of approved quality of any size set and jointed in grey cement slurry laid over and including 15 mm thick screed bed in CM (1:4) including polishing the granite stone by using mechanical grinder and moulding edges compete all as specified and as directed.
M&L for rounding to edges of stone slabs, such as in steps, cooking platform, and other similar situations.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified.
M&L for Machine cut kota stone slab flooring 20mm to 25mm thick over and including 15mm thick cement screed in cement mortar 1:4 including pointing, moulding the edges in white cement (1:2) using marble dust with admixture of pigment to match with shade of kota stone complete all as specified and directed
M&L for Kota stone slab 20mm to 25mm thick as in riser of steps, skirting, dado and pillar laid over and including rendering 10mm thick in cement mrtar 1:3 including pointing, moulding the edges in white cement 1:2 using marble dust with admixture of pigment to match with shade of kote stone complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specifed and directed.
M&L for 75 mm thick, plain cement concrete 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection etc, finishing the surface even and smooth without using extra cement i complete all as specified and directed. Note : concrete shall be laid at a stretch n.exc 3.0 m in length and every turning / corners.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed
S&F Stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves, filling in steel frames and the like complete all as specified and directed.Note:Reinforcement shall be measured and paid separately under relevant item.
M&L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified
Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar of any description including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for brick work with fly ash old size bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and directed
M&L for brick work with fly ash bricks stright or curved on plan to any radius, as in half brick thick wall built in cement mortar 1:4 complete all as specified and directed
S&F Gl wire netting 0.90mm dia & 12mm mesh in patches of lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting & waste complete all as specified
M&L for dubbing out average 15mm thick on irregular face of walls in patches in cement mortar 1:4 complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces of walls in two layers ,first layer with 10 mm thick im CM 1:6 and subsequently with 5 mm thick in CM 1:4 mixed with water proofing compound as per Manufacturer's instruction , finished the surfaces even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately under relevant item
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 as in ceiling surfaces in patches finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Supply only Liquid water proofing compound Make : SIKA / FOSROC / CHOKSEY
M&L for preparation of new plastered surfaces of wall and applying plaster of paris putty of 1 mm thickness over a coat of primer over newly plastered surface ,finished even and smooth and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete all as per Manufacturer's specification and as directed.
M&L for complete removal of existing treatment of old surfaces of wall and applying plaster of paris putty of 1 mm thickness over coat of primer over the prepared surface ,finished even and smooth and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete all as per Manufacturer's specification and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of primer complete all as per Manufacturer's specification and directed.
M&L for complete removal of existing treatment of any description from surfaces of ceiling and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of primer complete all as per Manufacturer's specification and directed.
M&L for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls complete all as specified and as directed .Make : APEX of Asian or other equivalent make of shalimar / Nerolac/ Berger.
M&L for complete removal of existing treatment of any description and applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces complete all as specified and as directed Make : APEX of Asian or other equivalent make of shalimar / Nerolac/ Berger.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area not exc.1.5 sqm each including separating guard bars/grills/wire mesh etc. complete all as specified
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exc.1.5 sqm but not exc 4sqm each including separating guard bars/grills/wire mesh etc complkete all as specified
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exc.4.0 sqm but not exc 7.5sqm each including separating guard bars/grills/wire mesh etc complete all as specified
Taking down shutters of any description exc. 1sqm but not exceeding 2sqm each including builders hardware complete all as specified .
S&F second class hard wood,plain solid straight chowkats and frames rebated on the solid, rounded or chamfered put together with glue pinned at joints, supplied and fitted complete all as specified and as directed.
S&F pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F pressed steel frames of size 125mm x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B0 using 12.5 mm graded crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs ,water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F 35mm thick second class hard wood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze, etc. with sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
S&F plain framed, panelled shutter 35mm thick (two panel) with lock rail & panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces ,second class hard wood rail & style of size all as per IS: 1003 (Part I), kiln seasoned & chemically pressure treated complete all as specified and as directed.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge metred cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the 19mm x 19mm square tube fixed to wall in repairs by drilling 100mm long MS screws using PVC fastener all as per specification and directed.
S&F Factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick with 2,4,6 raised panel design with 2mm thick moulded Prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing and all as directed.
S&F Butt hinges, 100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21
S&F Butt hinges, 100mm size medium weight cold rolled mild steel
S&F Aluminium anodised barrel tower bolts of extruded section 150mm long
S&F Aluminium anodised barrel tower bolts, extruded section of size 200mm long
S&F Aluminium handles cast type anodised 125 mm size
S&F Aluminium handles cast type anodised 150 mm size
S&F Aluminium alloy, anodised sliding door bolts 300mm long with hasp and stable (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections as specified and as directed.
S&F mild steel 300 mm , ordinary rat rail rod pattern springs including rollar and rollar plate complete.
S&F 140 mm over all length of cover plate, floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor.
S&F Aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wood/steel frames all as specified
M&L for preparation of new wooden surfaces of any description exc. 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified
M&L for preparation of new steel surfaces of any description exc. 10 cm in width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified.
S&F aluminium powder coated (Minimum thickness of powder coating 50 micron) frame for doors / windows / ventilator / partition including glassing clips with one or more tracks and joining cleats for fixing and other accessoreies as required complete all as specified and directed by Engineer-in-Chage .
S&F aluminium powder coated sliding window (for width 1.00 above and openable for below 1.50 M width) using alumimium section weighing not less than 0.495 Kg per RM for frame and 0.48 Kg per RM for sliding shutters including aluminium anodised snap beads, screws and fixed alongwith same section in three rolling sliding shutters two for fully glazed with 5mm thick tinted glass fixed with glazing clips, and one for wiremesh shutters etc including fixings of all builders hard ware such as wirmesh ,hinges, bow handles, locking arrangements etc complete all as specified and directed by Engineer-in-Charge.
S&F aluminium powder coated ventilators using alumimium section weighing not less than 0.48 Kg per RM for frame louvers aluminium anodised snap beads, screws and fixed alongwith with 5mm thick frostes/pin headed glass fixed with glazing clips, and one for wiremesh shutter fixed on frame including fixings of all builders hard ware such as wirmesh ,hinges, bow handles, locking arrangements etc complete all as specified and directed by Engineer-in-Charge.
S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
S&F Sheet glass 5.5mm thick, plain ordinary quality & glazing with oil putty in square exc 0.5 sq.m in each pane fixing to aluminium frame work including hacking out old broken glass (any thickness, size, quality or description ) from Aluminium section fixed with beads/glazing clips complete all as specified
S&F in repairs 12mm thick plywood, grade BWR,fixed with screws to timber frame work type BB with decoraive laminate type1 0.90mm thick of surface finish colour and pattern as approved and other side white lamination type 1 0.5mm thick fixed with approved adhesieve as per manufacturers instructions complete all as specified
S&F in repairs 18 mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work complete all as specified and directed.
S&F 6mm thick external teak wood lipping over 18/19mm thick particle board/plywood fixed with nails
S&F continous (piano)hinges mild steel,bright finish or electro galvanised width of flaps (when open) 30mm complete all as specified .
S&F in repairs Locks, drawer, cupboard shutters grade I, size 75 mm ,Brass 4 levers complete all as specified
S&F in repairs stainless steel cabinet hinges /self closing honges (Bombay Hinges) complete all as specified
S&F in repairs Magnet closures to cabinet cupboards complete all as specified
S&F in repairs stainless steel curtain rods with L clamps and with suitable globe brackets and brass screws complete all as specified
M&L for small articles such as hold fasts etc. of Flat Iron 25 x 3, Grade confirming to Fe-290 Gde E-165 complete all as specified
M&L for preparing small articles such as hold fasts, end of posts etc. of area n.exc 0.1Sqm and treated with Cresote Oil/ black bituminous paint complete all as specified
M&L preparing of wood and wood based materials, steel, and iron work, new or old and treating ends of posts, backs of chowkats, etc, area tarred exc 0.1 sq m but n exc 0.5 sq m each and treated with tar or coat tar black paint
M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate for fixing of hold fast complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate, as in floor,25mm average thickness , mixed with WPC at the rate of 200ml per bag of cement complete all as specified and directed. Note: Liquid Water proofing compound shall be measured and paid separately.
M&L for Plain Cement concrete 1:5:10 type E2 using 40mm graded stone aggregate in mass concrete in sunken floor, bed blcoks, and similar work complete all as specified and directed.
M&L for cleaning the surface (for sunken floor portion) with wire brush and washing with hydrocholoric acid to remove dust, dirt, oil grease, loose particle etc and applying a coat of water base acrylic polymer modified MIX GUARD AC or other equivalent make appoved by GE @ 1kg per sqm as in part A (Powder) and Part B (liquid) in a ratio of 3:1 with and including 20mm thick rendering in CM 1:4 as in sunken floor slab, walls mixed with intergal water proofing compound and finished even and smooth complete all as per Manufacture's instruction and all as directed by Engineer-in-Charge.
INTERNAL ELECTRIFICATION
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses,regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified
M&L for point wiring of size 1.5 sqmm with PVC insulated unsheathed multistranded copper conductor cabel of 1100V grade drawn through non metallic rigid PVC conduit including accessories, concealed in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete for complete for :-
one light point controlled by one switch
one fan point controlled by one switch
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
one bell/buzzer point controlled by one bell push
One light point controlled by two 2-way switch
All as per item No. 131 above but for One 3 pin socket outlet 15 Amps, independent, with 4.0 sqmm cable complete all as specified ( for Geyser & Ac)
All as per item No 131 but for one socket outlet three pin 15amps controlled by one switch, independent board with 2.5 sqmm size cable complet all as specified
S&F modular cover plate with frame 1 module complete all as specified
S&F modular cover plate with frame 3 module complete all as specified
S&F modular cover plate with frame 4 module complete all as specified
S&F modular cover plate with frame 8 module complete all as specified
S&F modular switches suitable for type AC 240V, 6 Amps 1 module complete all as specified
S&F modular switches suitable for type AC 240V, 6 Amps 1 module 2 way complete all as specified
S&F modular sockets suitable for type AC 240V, 6 Amps 2 module complete all as specified
S&F modular switches suitable for type AC 240V, 16 Amps 1 module complete all as specified
S&F modular power sockets suitable for type AC 240V, 16 Amps 2 module complete all as specified
S&F modular bell switch suitable for type AC 240V, 6 Amps complete all as specified
S&F call bell of multi music type A/C 230 volts complete all as specified
S&F ceiling rose , polycarbonate, isolated body with 2 to 3 terminals
Taking down ceiling fan and removing blades from fan body and depositing to store yard of AGE E/M including connecting rod, cotter pins and all accessories complete all as specified
S&F ceiling fans complete with blades, down rods, electronic regulator (2 Modular) and accessories, 230 V, 1200 mm sweep five star rated with brushless direct current (BLDC) motor, complete all as specified and directed.
Taking down Exhaust fans and depositing to store yard of AGE E/M including all accessories complete all as directed
S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers ,complete all as specified
S&F 20 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminum housing with wide range of wattages to suite variety of application areas, complete all as specified and directed Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or other equivalent make of Philips/Bajaj.
S&F 10 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminum housing with wide range of wattages to suite variety of application areas, complete all as specified and directed Make : Havells Cat No. LUMILINEPLUSBS10WLED865SPCSSIND or other equivalent make of Philips/Bajaj.
S&F 15 Watts round ceiling COOL LIGHT is a functional range of aesthetically designed surface mounted downlights with aluminum housing and heat sink for better thermal performances, complete all as specified and as directed Make : Havells Cat No. INTEGRANXTRDDLRSURD15WLED865S or other equivalent make of Philips/Bajaj.
S&F 10 Watts Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs, Complete all as specified and as directed Make : Havells Cat No. HEXAFT10WLED857SSYMBOPC or other equivalent make of Philips/Bajaj.
Taking down the existing geyser, refixing the same after all necessary plumbing and electric works done and make necessary repairs if any, complete all as specified and as directed
Taking down AC box any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F MCB Power unit with 4 module steel box consisting of 3 pin 24 Amps socket with Plug top and MCB SP 25 Amps, suitable for operation of AC & Geysers etc. complete all as specified. Make :- Havells/Legrand/Anchor
Taking down sub main wiring any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F sub main wiring complete with two runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable (FRLSH) of 1100 volts grade drawn through into non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed Note:- Two runs of PVC insulated cable 10 sqmm and one run 10 sqmm of earth wire and one run of conduit including accessories shall be measured as one unit length.
Taking down MCB DB any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F MCB distribution board made of 1.2mm thick special grade CRCA sheet, powder coated with high quiality weather proofing paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 430 Volt 12 way MCB DB , SPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one complete all as specified and directed by Engineer-in-charge
S&F MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 8 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection complete all as specified.
Taking down MCBs any type and any size complete after taking proper disconnecting electric supply properly and making good surface complete all as specified and directed.
S&F MCB of rating 240 Volts, SPN 63 Amps
S&F MCB of Single pole of rating 6 to 32 Amps 240 Volts
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4 mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified inlcuding testing on completion.
S&F LED security light fitting 35 Watts made out of pressure die cast aluminium powder coated housing high impact resistant 4 mm thick toughened glass cover and matrix of power LEDs in built electronic driver up to 4 KV surge protection fitted with adjustable pole adopter to enable on site tilt angle setting and input power 25 W system lumens 85/W operating voltage 160-260 V including brackets made out of 25 mm / 20 mm dia GI medium grade tubing of suitable length and bend to shape including fixing MS flat iron clamps, bolts & nuts as per site requirement complete all as specified and as directed.
EXTERNAL WATER SUPPLY
M&L for cutting existing GI water tubing in position for insertion of Tee of 80 x 80 x 40 mm size to connect GI pipe 80 mm dia including necessary earth work excavation complete all as specified and directed
Supply and lay galvanised steel water tubing 40mm bore medium grade with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., laid in trenches complete all as specified
Supply and lay galvanised steel water tubing 25mm bore medium grade with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc.,fixed complete to walls and ceilings or laid in floors complete all as specified .
S&F 25mm bore Gun metal globe / Gate valve conforming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe including all fittings/ fixutres like nipple, union etc, complete all as specified and directed.
Taking up or down steel tubing and connections of 40mm dia from any position complete all as specified
Taking up or down steel tubing and connections of 25mm dia from any position complete all as specified
YOGAA MANPOWER AGENCY (BID ID -3456124)
G.L.THIRUMALAI NAIDU AND COMPANY (BID ID -3453599)
Banyan Engineers and Contractors (BID ID -3455959)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
88493TENDER.pdf
Tender Documents • 1.03 MB
BOQ_821228.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .