Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.2 LAccepted-AOC 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L1 | Accepted-AOC Being lowest tendereer | |
| 2 | L2₹74.9 L+₹3.7 L (5.15%)Rejected-Finance | L2 | Rejected-Finance Being other
than lowest
tenderer | |
| 3 | L3₹77.7 L+₹6.5 L (9.11%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600 043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L3 | Rejected-Finance Being other
than lowest
tenderer | |
| 4 | L4₹77.8 L+₹6.6 L (9.23%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-Finance Being other
than lowest
tenderer | |
| 5 | L5₹79.0 L+₹7.8 L (10.9%)Rejected-Finance 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L5 | Rejected-Finance Being other
than lowest
tenderer |
Tender Value
₹89 L
EMD Value
₹1.6 L
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
86497E8 PROVN OF POWER BACKUP FOR CADETS ACCN AT OTA, CHENNAI UNDER GE STM CHENNAI
2021_MES_461585_1
86497E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
STM CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE STM CHENNAI
₹1.6 L
Yes
11 Oct 2021
20 Jul 2021
30 Aug 2021
20 Jul 2021
23 Aug 2021
10 Aug 2021
20 Jul 2021 - 28 Jul 2021
60 days
Amount
BOQ UPLOADED ON 20 JUL 2021
SCH "A" PART-I (DG SET AND ALLIED WORKS)
Earthwork in excavation by mechanical means (hydraulic excavator) in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and as directed.
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Common burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
Taking out existing cable any type / cross section upto 300 sqmm and supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(a) 3.5 core, cross sectional area 95 sqmm.
(b) 3.5 core, cross sectional area 120 sqmm.
(c) 3.5 core, cross sectional area 300 sqmm.
Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under roads / crossings etc., of the following bores for cable protection complete all as specified and as directed.
Earthwork, cutting across roads etc., as required shall be measured and paid separately.
(a) 50mm bore of pipe.
(b) 80mm bore of pipe..
Steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors / laid through out the bridge including necessary clamps, clips, wall hooks, wooden plugs for fixing the pipes in position, the following bores complete all as specified and as directed.
(a) 50mm bore of pipe.
(b) 80mm bore of pipe..
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 32mm x 6mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Supply, installation, commissioning and testing of silent type DG set complete with sound proof canopy ,diesel engine driven generating set of Prime Power (PRP) Output of 200 KVA at NTP, with 10 % overload capability in accordance with ISO-8528 and ISO-3046 AC 415 Volts, 3 phase, 4 wire 0.80 power factor directly coupled to diesel engine water cooled mounted on common MS fabricated frame with AVM pads weather proof as per CPCB norms, acoustic enclosure installed on a PCC hard standing , to be constructed by the tenderer as per manufactures’ recommendation ,with and including all excavation for PCC foundation, vibration dampers and other accessories comprising of ENGINE, ALTERNATOR, AMF CONTROL PANEL, GEN SET CONTROLLER, CONTROL SYSTEM AND MISC WORKS complete all as specified and as directed.
The brief requirement of the DG Set is given in the BOQ. The tenderer shall however read the same in conjunction with the particular specifications given here-in-after and rate quoted id deemed to include for all the provisions given therein.
AM BUILDERS
lakshmibuilders
devan enterprises
EVEREST ENGINEERING WORKS
Global Safety Engineering and Management Solutions
pmv.enterprises
SRI LAKSHMI ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .