Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.9 L+₹25,838.15 (1.76%)Rejected-Finance | L2 | Rejected-Finance Being not L1 |
Tender Value
₹14.1 L
EMD Value
₹28,200
Closing Date
23 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF MISCELLANEOUS WORKS AT 2 AFSB MYSORE
2023_MES_633340_1
82138/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) Chimney Hills
As per tender documents
7 documents required · 7 mandatory
₹500
AGE (I) (AF) Chimney Hills
₹28,200
26 Feb 2024
18 Dec 2023
25 Jan 2024
18 Dec 2023
23 Jan 2024
4 Jan 2024
18 Dec 2023 - 28 Dec 2023
Amount
Surface excavation not exc 30 cm deep and avaraging 15 cm deep and getting out soft/loose soil, all as specified and directed.
M & L for excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard/dense soil complete all as specified and dirtected..
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soft disintegrated rock, all as specified and dirtected..
Removing excavated material n. exc 250 M and depositing where directed at a level not exc 500 M above the starting point as per directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard/dense soil, all as specified and directed.
M&L Hard core of gauge n exc 63 mm broken stone deposited, spread and levelled in layers n exc 15 cm thick, watered and well rammed to a true surface, all as specified and directed.
M&L for cement concrete type B2 1:2:4 (40 mm graded aggregate)filling in mass concrete in post holes, all as specified and directed.
M & L for Plain Cement Concrete 1:3:6 Type C2 using 40 mm graded stone aggregate as in foundation concrete complete all as specified and dirtected.
M&L for PCC 1:2:4 Type B1 using 20 mm graded aggregate in win- dow or door cills, lintels,bressumers, steps,quoin blocks (for use with masonry), string courses, copings.kneelers, apex stones, pier caps,columns, posts,boundary pillars,bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling).corbels, brackets,etc. (of any section indicated), with plain fair faces,including chamfers, weatherings,throat- ing etc. and setting in mortar complete with joints to match complete all as specified and directed.
M&L for Providing precast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas,water troughs,mangers, shelves and similar articles with plain faces including chamfers,weatherings,throating etc and setting in cement mortar 1:4 complete with joints to match etc complete all as specified and directed.
M&L Precast cement concrete block masonry type C1 1:3:6 (20mm graded aggregate) with solid blocks exc 10 cm in width and setting in CM 1:4 complete all as specified and directed.
M&L for aluminium anodised powder coated windows with 3 channels for catering mosquito proofing &4mm thick plain/tinted glass with necessary accessories like jointing cleats, rubber packing,beading,air gaps filled with silicon agent and screws etc complete,including powder coated aluminium grill of DG-103 as per TD drg no AFB/TD/352/11,Sheet 1/2 & 2/2 and AFB/TD/237/05,Sheet 1/1, all as specified and directed.
M&L aluminium anodised powder coated ventilator with 4mm thick tinted glass with movable/ adjustable system incl necessary accessories like jointing cleats, rubber packing,beading,air gaps filled with silicon agent and screws etc complete all as specified.
S&F of Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded door frame complete all as specified and directed.
S&F for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, all as specified and directed.
S&F for Plain, Aluminium sheeting of 0.71 mm thick, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) fixed with self tapping screws as specified and directed.
M&L for Cutting opening in cement concrete/brick walls (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces wirh cement plaster where ever required,providing litel beam for top of the door where required and fisnish the area suitable for fitting to steel door, all as specified and as directed.
M&L for framed work such as grills, gratings, gates etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tank and similar works including fixing to channel section using MS bearing hinges to frame confirming to Fe-290 grade-E-165.
M&L for framed work as in Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. in cluding cleats, brackets, etc, Fe-410- W(Gde E-250) quality B, complete all as specified and directed.
Repair to collapsible steel gates n exc 9 sqm, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified, erected in position and securing runners position and securing runners with hold fast and brackets, complete greasing and oiling to movable position and replacing old runners if required, complete all specified and directed.
S&F for powder coated aluminium Anodised section of size 83.50x44.45x2 mm thick or equivalent sections for aluminium partition including sliding door for horizontal and vertical style for inserting12mm thik particle board or 6 mm thick black tinted glass fixing of fittings wherever required with necessary accessories like jointing cleats, rubber packing,beading,door handles,tower bolt,sliding bolt and locking syStem and screws etc complete all as specified and directed .
S&F for Welded steel wire fabric supplied and fixed complete to wood or steel members weight n exc 4.00 kg/sqm complete all as specified and directed.
M&L for mild steel TMT bars 6 mm to 8 mm dia and over, cut to length, bent to shape required including cranking bending spirally & binding with and including mild steel wire (annealed) not less than 0.9mm dia etc complete all as specified and directed.
S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire & average width of aperture 1.40mm with tinned tacks, or galvanised wire staples, all as specified and directed.
M&L for 55mm thick avarage thickness cement concretet 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring surface is to be finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick cement plaster on fair faces of brick work on concrete surfaces in cm (1:4) rendering to be finished even and smooth without using extra cement complete all as specified and directed.
M&L for framed work such as grills, gratings, gates etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tank and similar works including fixing to channel section using MS bearing hinges to frame confirming to Fe-290 grade-E-165, all as specified and directed.
S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde-E-250) quality A, all as specified and directed.
S&F compound girders and stanchions,lattice girder, aerial masts, stging for water tanks and the like including caps,bases, splices etc.builtup from two or more beam or channel section or angles with plates,including all lattice bars,stiffeners,gusset plates,etc of Fe-410-W(gde-E-250)quality-A, all as specified and directed.
S&F for steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.or induction butt welded to angles, cleats conforming to I. S.1161-1979 grade St.-240, all as specified and directed.
S&F Non - skid Ceramic colouerd tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but n exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20 mm thick screed bed or bedding layer of mortar 1:4, all as specified and as directed.
M&L for providing 75 mm thick Cement Concrete type D-2, 1:4:8 (40 mm graded stone agg) as in sub base to floors.
M&L for providing 100 mm thick Cement Concrete type B-1, 1:2:4 (20 mm graded stone agg) as in floor etc, all as specified and directed.
M&L for providing 75 mm thick Cement Concrete type D-2, 1:4:8 (40 mm graded stone agg) as in sub base to floors, all as specified and directed.
M&L for providing 100 mm thick Cement Concrete type B-1, 1:2:4 (20 mm graded stone agg) as in floor etc complete all as specified and directed, all as specified and directed.
M& L for mastic flooring for gas godown purpose is a mixture of fine and coarse limestone and dolomite aggregate and synthetic bitumen 90/15 Grade laying thickness min 30mm,levelling uniformly to existing concrete flooring finishing smooth complete all as specified and directed.
S&F PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls 110 mm bore pipe, all as specified and directed.
S&F PVC (SWR) bends any radius 110 mm bore pipe, all as specified and directed.
S&F for PVC (SWR) junction single, (Single T) equal or unequal 110/110 mm bore, all as specified and directed.
S&F Salt-glazed stoneware gully traps, square or round mouthed, tvpe 'P' size 150 mm x 150 mm complete with for setting and jointing to drains with cement mortar 1:1 including necessary excavation and earth work concrete in beds,surrounds,kerbs etc and cast iron grating complete all as specified and directed.
S&F for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in 150mm dia bore reinforced cement concrete pipe complete all as specified and directed.
S&F for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for dia of pipe 150mm complete all as specified and directed.
Taking down cement or cement plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on brick or concrete surfaceof walls, surface finished fair and even without using extra cement, all as specified and directed.
M&L for preparation of plastered and other surfaces with alkali resistant priming paint new plastered surface on walls and applying two coats of cement based paint complete all as specified and directed.
M&L preparation of old distempered wall surfaces by washing, rubbing down and stopping of distempered surfaces and applying one coats of distemper oil emlusion.
M&L for preparation of plastered and other surfaces with alkali resistant priming paint old plastered surface on walls and applying two coats of cement based paint complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat red oxide, all as specified and directed.
M&L for writing of letters in English and hindi on MS plates background colour will be white,letters in red colour for safety/operating instructions of fire safety what ever directed,red colour painting to bottom wall area,indicating FP No,bordering with red colour line,smooth finishing complete all as specified and directed.
Making good under cills or over arches, lintels and bressummers, including all pinning when necessary in CM 1:4, all as specified and directed.
Supply and fixing LED light fitting 1 x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, all as specified and as directed.
Supply and Fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, all as specified and as directed.
M&L for Point wiring with 1.5 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of same size as in phase/neutral and connected to common earth dolly drawn through and including ERW conduit and coduit accssories all as directed alongwith fittings and accessories, fixed /laid/concealed in walls/ceilings including cutting chases and making good to walls, floors etc, and also incl suitable sunken type pressed steel terminal box and suitable laminated sheet top cover for One light point or one fan point controlled by one switch, all as specified and as directed.
M&L for Point wiring with 2.5 sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS-694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of same size as in phase/ neutral (2.5 Sqmm) and connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongth with fittings and accessories, fixed/ laid/ concealed in walls/ ceilings inculding cutting chases and making good to walls, floors etc, and also incl suitable sunken type pressed steel terminal box and suitable laminated sheet top cover for One light point or one fan point controlled by one switch, all as specified and as directed.
Supply and Fix febricated MS clamps with two coat of red oxide primer and one coat of synthetic enammeled paint including screwing/ cutting of wall and make good with existing colours for fixing of lights, all as specified and as directed.
S & F Switch socket combination 2in 1, 3 pin, 6 and 16 Amp flush type universal, all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & pavings n exc 15 cm thickness (below or above ground level), all as specified and directed.
Taking down steel window and ventilator (Without taking off shutter from the frame) of area n exc 1.50 Sqm each.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
A. N. Kalbhavi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .