Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | L1 | Accepted-AOC First Lowest | |
| 2 | L2₹3.8 L+₹2,020 (0.53%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹4.2 L+₹45,205 (12.0%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹4.3 L+₹55,530 (14.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹4.6 L+₹80,890 (21.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹6.6 L
EMD Value
₹13,288
Closing Date
8 Mar 2024, 9:30 amClosed
Executive Engineer
EE,EandM, Division, APWD, Prothrapur, Port Blair
Construction of Gram Panchayat Building at Wandoor under EE, CD-III, Prothrapur SW Providing IEI
2024_APWD_13707_1
NIT No 99/EE/EandM/23-24 2nd call
Open Tender
Electrical Works
Item Rate
30 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹13,288
16 Apr 2024
1 Mar 2024
8 Mar 2024
1 Mar 2024
8 Mar 2024
4 Mar 2024
1 Mar 2024 - 4 Mar 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
c) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying, Installation, Testing and Commissioning of BLDC Ceiling fan (1200 mm) sweep, 5 Star rated Speed Controlled, ISI marked with all accessories etc., as required Make: Havells Model No. Efficiencia DX BLDC with out remote with 5 years warranty and with out regulator (ISI Marked and BEE 5 Star Rated) power consumption with switch control or its equivalent.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying of Plastic Exhaust Fan 200mm sweep with accessories etc as equivalent to Havells Model Ventil Air Dx or its equivalent.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450 mm sweep
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
Supplying of LED 12W Bulb in the existing Batten Holder similar to Havells comfy Vizon LED12W-B22-CDL 3 Star cat No LHLDDEAID4R012 or its equivalent make as required.
Supplying, Installation, Testing and Commissioning of CRCA housing Box type Luminaries suitable for T8 LED Tube (1 x 18 / 20W) similar to Bajaj Model No. BLRB - DB 118 or its equivalent makes required
Supplying & fixing of 20 W LED Tube light with high performance in the existing Tube lamp fitting similar to Bajaj: Model No. BLRB 20W LED or its equivalent make. As required
Supplying and Fixing of 20W LED Street light Fitting similar to Luker model No. LSTE-20 or its equivalent with suitable bend pipe on the existing wall of the building including clamping, connection etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 4 way (4 + 12), Double Door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required a) 25 Amps, 25KA TPMCCB
b) 63 Amps, 36KA FPMCCB
Supplying of following sizes of XLPE insulated Heavy duty armoured aluminium conductor UG Cable of 1.1 KV Grade conforming to IS: 7098 (part-I) and IS No. 1554 (part-I) 1988 as applicable Make: CCI/ GLOSTER/ Havells/ Polycab/ Finolex. a) 25 Sqmm x 3.5 Core (M.S)
Supplying and Laying of following one Number Double walled corrugated high density poly thylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS: No. 14930 Part I & II complete with necessary HDPE fitting for protection of 1.1 KV grade directly in ground at the depth of 50 cm i/c excavation & refilling the trench etc as required. a) 50 mm outer dia and 38 mm inner dia
Supplying and Laying of following one Number Double walled corrugated high density polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS: No. 14930 Part I & II complete with necessary HDPE fitting for protection of 1.1 KV grade directly in ground /clamping on wall surface etc as reqd. a) 50 mm outer dia and 38 mm inner dia
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm (Clamped with 1mm thick saddle)
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok) (Proof/ Test Certificate should be enclosed)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
DILIP RAJ
M/s G K Construction
AKABEA INFRASTRUCTURES PRIVATE LIMITED
JOY GURU ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .