Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹24.9 L Quoted ₹25.7 L | L1 | Accepted-AOC OK |
| 2 | L2₹26.4 L+₹71,471.25 (2.78%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹26.4 L+₹71,471.25 (2.78%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹27.2 L+₹1.5 L (5.89%)Rejected-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | ₹27.2 L+₹1.5 L (5.89%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹28.1 L+₹2.3 L (9.14%)Rejected-Finance INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | ₹28.1 L+₹2.3 L (9.14%) | L4 | Rejected-Finance Other than lowest tenderer |
| 5 | L5₹28.7 L+₹3.0 L (11.7%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | ₹28.7 L+₹3.0 L (11.7%) | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Jul 2020, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT-10
GE E/M BASE HOSPITAL DELHI CANTT-110010
REPAIRS/ MAINTENANCE OF STREET LIGHTS FITTING, REWINDING OF CEILING FANS, EXHAUST FAN, WALL MOUNTED FANS, GEYSERS, ACS AND OTHER ALLIED WORKS AS CABINET SECTT UNDER GE E/M BHDC-10
2020_MES_355268_1
GE/BH-24/2020-21
Open Tender
Electrical and Maintenance Works
Works
180 days
GE E/M BASE HOSPITAL DELHI CANTT-10
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT-10
₹96,000
Yes
10 Oct 2020
23 Jun 2020
15 Jul 2020
23 Jun 2020
13 Jul 2020
5 Jul 2020
Amount
Attending day to day Street light complaints (Street lights fitted on poles/buildings at height up to 12 mtr from ground level) including repair/replacement of unserviceable nuts, bolts, clamps etc and repair/ replacement of unserviceable onnected accessories like cables, wires, MCB/ MCCB's, earthing, earthing strip, earth wire, Service Pillar (Feeder Pillar) bus bars, HRC fuses, rewirable fuses, contactor, timers, connector, wires, glands, thimbles etc by deploying adequate resources for attending and rectifying the defects of street lights and monitoring system complete all specified and directed.
Note: (a) Stores required for repair shall be measured and paid separately under respective items of sch.
(b) Replacement of worn out cables/wires etc. including excavation and cost of Tower wagon, cable fault locator equipment and all required tools, ladders, and all other incidental operations required for execution of maintenance work are included in the quoted rate for smooth operation.
(c) Adequate resources shall be deployed by the contractor for attending and rectifying the complain being an essential deptt.
(d) All the T&P items like eight feet height aluminium folding ladder with self supported, drill machine with bits of any size shall be arranged by the contractor at no extra cost at the time of commencement of work other wise Rs 500/day shall be recovered from the contractor. Tool Bags required for attending the complaint shall be issued by contractor to the tradesman.
(e) All the stationery i.e complaint register, job card dockets and other connected register related to the work shall be arranged and to be maintained by the contractor.
(f) Contractor shall be panelised @ Rs. 400/- per complaint/ day, if he fails to attend and rectified the complaint within 8 hours including Sunday/Saturday/Holiday on direction by verbally/telephonically.
(g) For any nature of complaint related to electric appliances other than complaint maintained in above description are also required to be done by the person employed as directed by the concern JE E/M other wise penalty @ of Rs 200/complaint shall be recovered.
(h) Any minor stores required for rectification of electric complaints other than item mentions in CA as provided by the department will also required to be fixed by the persons employed under subject CA without any extra cost .
(j) Cost of all consumable items like cotton waste, PVC insulation tape, nut bolts, screws shall deemed to be included in quoted rate.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in any type of soil (soft/loose soil) for foundation and getting out and levelling of bottom surface to required level complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming soils in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing the excavated materials not exceeding 50 m and depositing where directed at level not exceeding 1.5 m above the starting level complete all as specified and as directed.
Supply and spread fine river washed dry sand for cable cushioning in trenches, under and above of the cable complete all as specified and as directed.
Supply and lay in trenches unreinforced pre-cast cement concrete cable cover LV, type 2, flat size 250 mm x 150 mm x40 mm complete all as specified and as directed.
Boring of holes under road/pavement/hard standing or any other situation by manual mean for passing GI pipe 50mm bore grade and making good both the ends all as specified and directed at site. Note:- GI pipe shall be measured and paid separately under respective item of this Sch.
Cutting of existing road/hard standing for laying cables/pipe including making good the disturbed surface to match with the adjoining surfaces with PCC 1:3:6 type C2 complete all as specified.
Supply, laying and jointing, in trenches / passing through pipes/ fixing on poles/fixing on wall with saddles in replacement LT under ground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm, 2 core including cable connecting lugs, glands, jointing fixing materials after taking out old unserviceable cables complete all as specified and as directed.
All as per item Ser No 9 here-in-before but 4 core 10 Sqmm complete all as specified and as directed.
All as per item Ser No 9 here-in-before but 4 core 16 Sqmm complete all as specified and as directed.
Supply, laying & jointing fix in repair 2.5 Sqmm, single core Two runs PVC insulated and unsheathed FRLS cable 1100 Volts grade with multistranded copper conductor and one run of 1.5 Sqmm cable for common earth dolly drawn through street light pole including connection from kiosk box to street light fittings complete all as specified and as directed. Note :- Two run of 2.5 Sqmm cable and one run of 1.5 Sqmm cable shall be measured as one length.
S&F in replacement high power LED 35 W, vertical/horizontal surface mounting pressure die cast aluminium well glass luminaires complete all as specified and as directed. Make- Havells cat part No ENDURAWELLGLASSNEOTSS35W LED757SPCSO or equivalent model of CG/PHILIPS
S&F in replacement high power LED 50 W, vertical high bay/medium bay LED IP54 luminaire with high power COB LED complete all as specified and as directed. Make- Havells cat part No ENDURAHIBRITEPLUSHBP50W LED750S90DTOLENS or equivalent model of CG/PHILIPS
S&F in replacement high power LED 50W, die cast aluminium flood light suitable for highlighting architectural features or area lighting complete all as specified and as directed. Make- Havells cat part No JETACOMPECTOFL50W LED757 LTG or equivalent model of CG/PHILIPS
S&F in replacement high power LED 70W , die cast aluminium flood light IP65 suitable for highlighting architectural features and general purpose lighting complete all as specified and as directed. Make- Havells cat part No JETAFLAREFL70W LED 757 LTG or equivalent model of CG/PHILIPS
S&F in replacement high power LED 35W , post top IP 65 aesthetically designed with symmetrical light distribution , spun aluminium landscape luminaire with high power LEDs complete all as specified and as directed. Make- Havells cat part No CORALPT35W LED 757PSYMTOPC or equivalent model of CG/PHILIPS
S&F in replacement LED 60W, street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built in surge protection device including driver complete all as specified and as directed. Make- Havells cat part No ENDURAPEARLPLUSSL60W LED757SASYTOPC or equivalent model of CG/PHILIPS
S&F in replacement LED 90W, street light made up of pressure die cast housing with toughned glass and individual high power LED with secondary optics, IP65 protection and impact resistance of IK07 including driver complete all as specified and as directed. Make- Havells cat part No ENDURACITY LINERNEOSL90W LED757SASYBOTG or equivalent model of CG/PHILIPS
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised ironstrip 32×6mm as earthing lead by means of nuts, bolts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 5 and test point including testing on completion complete all as specified and directed. Note:- The unit rate quoted shall be include for necessary excavation and earth work , earth strip connected to test point max 7 mtr as per site requirement, PCC 1:3:6 type for earth pit & Pit cover, funnel with wire mesh including GI medium grade watering pipe 15mm bore & 40 mm dia for supporting of earth strip/wire.
S&F GI earth strip of size 32x6 mm connected both ends with necessary bolts, nuts & washers complete all as specified and as directed.
S&F in replacement fire retardant non transparent Kiosk junction box of size 310x210x120mm made of engineering plastic on piece moulding, out door type heavy duty with 04 Nos of insulated aluminium bus bar of 60 Amps capacity mounted on unbreakable insulators including 10 A MCB SP - 01 No complete with aluminium lugs of suitable size upto 50 Sqmm including 02 Nos 40 x 3mm FI clamps nut bolts washers etc duly painted both side with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. Make- Universal Switch Gear/ Schinder/ Sintex Note:- Cost of MS clamp, nuts, bolts and washers shall be included in the quoted rate.
S&F in replacement bracket for street light fitting made out of 40 mm bore light grade GI pipe of length 1.50 mtr bend/weld to shape at 120 degree for fixing of street light fitting on pole complete all as specified and as directed. Note:- Cost of MS clamp, nuts, bolts and washers shall be included in the quoted rate.
S&F in replacement GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection or fixed to the pole/ wall etc for cable protection complete all as specified and as directed. Note:- MS clamps for fixing of GI pipe shall be measured and paid separately.
M&L for rewinding of ceiling fan of any make and model of 1200 mm sweep complete with super enamelled copper wire of required size duly varnished with high quality varnish and testing complete all as specified and as directed. Note:- (i) Fans shall be issued from cab sectt store yard and will be taken by the contractor to civil work shop for repair and to bring back repaired fans to cab sectt at his own arrangement as required. (ii) Cost of ball bearing and other parts shall be measured & paid separately from respective item.
All as per item No 25 here-in-before but 1400 mm sweep complete all as specified and as directed.
M&L for rewinding of exhaust fan of any type and make with super enamelled copper wire of required size covered with high quality varnish complete of 300 mm sweep (12'') including greasing / oiling and testing complete all as specified and as directed.
All as per item No 27 here-in-before but for upto 450 mm sweep (18'') complete all as specified and as directed.
All as per item No 27 here-in-before but for upto 600 mm sweep (24'') complete all as specified and as directed.
M&L for rewinding of cabin fan/wall mounted fan of any make and sweep with supper enamelled copper wire of required size covered with high quality varnish complete including greasing /oiling removing of U/S bearing/bush/shaft and other parts and testing to the entire satisfaction of Engr-in-Charge complete all as specified and as directed. Note:- Cost of spares as required will measured and paid & separately under relevant items.
Supply only in replacement of ball bearing suitable for ceiling fans 1200/1400 mm of any size for proper running and testing complete all as specified and as directed. Make - SKF/NBC/TATA/HMT.
Supply only in replacement ceiling Fan blades as per existing pattern (set of three)of size 1200 mm sweep complete all as specified and as directed. Make- Usha /orient /Bajaj or equivalent.
All as per item No 32 but 1400 mm sweep complete all as specified and as directed. Make- Usha /Orient /Bajaj or equivalent.
Supply only in replacement Gun metal bushes for ceiling / wall fans any sweep including oiling and testing for proper running Make - SKF/NBC/TATA/HMT.
Supply only Bracket assembly of various sizes as required for hanging ceiling fan with rubber shakle nuts bolts and split pin all as required at site complete all as specified and as directed.
Supply only iron hook by using 8mm iron bar suitable for hanging ceiling fan as per site requirement complete all as specified and as directed.
Supply only in replacement of rotor shaft of ceiling fans of size 1200 mm sweep complete all as specified and as directed.
All as per item No 37 here-in-before but 1400 mm sweep of suitable size complete all as specified and as directed.
S & F stepped type Electronic Fan Regulator flush type switch size on the existing phenolic laminated sheet etc as per required at site complete all as specified and as directed. Make-Anchor/Havells/SSK.
M&L for cleaning of old dusted surface of three set of blade of ceiling fan of any capacity at existing location by using scraping cleaning complete all as specified and as directed. Note:- (a) T&P items as required shall be arranged by the contractor at no extra cost.
All as per item No 40 here in before but exhaust fan complete all as specified and as directed.
S&F in repair Air circular with wall mounting fan single phase 1440 RPM 18'' sweep heavy duty complete all as specified and as directed. Make- ALMONARD/Havells/Bajaj/CG. Note:- Old unsv fan shall be deposited in MES store yard by the contractor.
S&F metal body Exhaust fan 230 mm, sweep single phase 1400 RPM 12'' sweep heavy duty complete all as specified and as directed. Make- Havells/Bajaj/CG. Note:- Old unsv fan shall be deposited in MES store yard by the contractor.
All as per Ser item No 43 here in before but 300 mm sweep 1400 RPM complete all as specified and as directed.
All as per Ser item No 43 here in before but 450 mm sweep 1400 RPM complete all as specified and as directed.
All as per Ser item No 43 here in before but 600 mm sweep 900 RPM complete all as specified and as directed.
Supply and fixing ventilating fan 230 mm sweep Volt AC with sturdy blades fully plastic body complete sound proof complete all as specified and as directed. Make-Havells model Ventil air DXW. Note:- Old unsv fan shall be deposited in MES store yard by the contractor.
All as per Ser item No 47 here-in-before but 150 mm sweep complete all as specified and as directed. Make-Havells model Ventil air DX
S&F single phase, 230 volts, 50 Hz, wall mounted fan, 450 mm sweep fixing on wall with fan clamp/hook, connecting electrically complete all as specified and as directed. Make- Havells/Bajaj/Orient/Khaitan Note:- Old unsv fan shall be deposited in MES store yard by the contractor.
S&F in replacement ceiling Fan 1400 mm sweep, motor speed min 400 RPM single phase AC Energy saving complete as per manufacturer specification complete all as specified and as directed. Make- Havells/Bajaj/Usha Note:- Old unsv fan shall be deposited in MES store yard by the contractor.
Supply only in repair condenser 2.5 mfd including fixing of clamps with screws, sleeves etc complete all as specified and as directed. Make:- EPCOS/ Usha/
All as per item No 51 here in before but 3.15 mfd complete all as specified and as directed.
All as per item No 51 here in before but 4 mfd complete all as specified and as directed.
Supply only in repair down rod of ceiling fan made 1 mtr long MS pipe medium grade 20 mm including with bolts/check nuts, washers, safety pin etc as per existing size and shape of fans incl New U hook with rubber reel with nut bolt and washer including drilling, threading etc complete all as specified and as directed.
Supply and fixing in replacement heating element of geyser with new one for suitable for 25 ltrs/50 ltrs capacity of geyser complete all as specified and as directed. Make- Racold/ Theeta/
Supply and fixing in replacement thermostat for any make suitable for 25/50 ltr capacity of geyser complete all as specified and as directed. Make- Racold/ Theeta/
Supply and fixing Geyser (Heater water storage type) 50 Ltr capacity energy saving 5 star rating and all features as per manufacturer's specification 240V electric supplied and installed complete including 2 years maintenance spare parts guarantee complete all as specified and as directed. Make:- Havells Bello/ Bajaj/ Recold Note:- Old unsv geyser shall be deposited in MES store yard by the contractor.
All as per item No 57 here in before but 25 ltrs capacity complete all as specified and as directed.
M&L for servicing of split/window type AC of any make of capacity 1.5/2 TR indoor unit and upto 3 TR outdoor unit by disconnecting the electric connection taking out from its position, cleaning the external dirt and dust, cleaning of air filter, condenser, washing by water jet, drying by air blower, checking all electrical connections and refixing in existing position and testing etc complete all as specified and directed . Note:- (a) T&P items as required shall be arranged by the contractor at no extra cost.
S&F in replacement compressor unit re-appropriated by manufacturer with relevant warranty certificate including necessary charging the system suitable for Window/ Split type AC 1.5 Ton capacity complete all as specified and as directed. Make- Hitachi/ Voltas/ Blue Star/ Carrier.
M&L for flushing out the complete system ,re-charging of Refrigerant gas of split/window type AC upto cap 3 Ton and checking for leakage after filling of gas complete all as specified and as directed..
M&L for disconnecting and taking down burnt out blower motor of window/split type AC capacity up to 1.5 TR, opening the motor and removing burnt out winding, rewinding the same with supper enamelled copper wire of existing gauge, varnishing heating, including refixing in the existing position with and including accessories etc complete all as specified and directed.
M&L in replacement condenser coil for window/split type AC capacity up to 1.5 TR complete all as specified and directed.
M&L in replacement capillary tube for window/split type air conditioner capacity up to 1.5 TR complete all as specified and directed.
S&F in replacement front grill of window/split type AC capacity up to 1.5 TR as per existing make & size complete all as specified and directed.
S&F in replacement air filter of window/split type AC capacity up to 1.5 TR as per existing make & size complete all as specified and directed.
S&F in replacement relay of window/split type AC capacity up to 1.5 TR as per existing make & size complete all as specified and directed.
S&F in replacement starting capacitor of window/split type AC capacity up to 1.5 TR as per existing make & size complete all as specified and directed.
S&F in replacement running capacitor of window/split type AC capacity up to 1.5 TR as per existing make & size complete all as specified and directed.
S&F in replacement thermostat switch of window/split type AC capacity up to 1.5 TR as per existing make & size complete all as specified and directed.
S&F in replacement Fan blade of window/split type AC capacity up to 1.5 TR as per existing size & make complete all as specified and directed.
S&F in replacement PCB of window/split type AC capacity up to 1.5 TR as per existing size & make complete all as specified and directed.
S&F in replacement Swinging motor of split type AC capacity up to 1.5 TR as per existing size & make complete all as specified and directed.
S&F in repair energy efficient LED light fitting recessed mounted 2x2 ft, 34 Watt, Ultra moderned designed architectural LED luminaire with white powder aluminium housing with integrated electronic driver, complete fixed on ceiling complete all as specified and directed. Make- Havells cat part No PLUTONEO 2X2PLR34WLED857S or equivalent model of Philips/ Wipro.
S&F in repair energy efficient LED light fitting, Pluto panel surface mounted 2x2 ft, 34 Watt, Aesthetically designed, LED flat panel for surface mounted with electronic driver complete fixed on ceiling, all fixing complete all as specified and directed. Make- Havells cat part No PLUTOSURFACE2X2PLS34WLED857S or equivalent model of Philips/ Wipro.
M&L point wiring for modular switches with 2X1.5 sqmm , single core , multi stranded copper conductor PVC insulated (one for essential & one for normal supply) and unsheathed cable 1100 Volts grade, drawn through concealed including rigid non-metallic PVC Conduit with all fittings of suitable dia as per site requirement including cadmium plated screws as per IS and replacement of 3 mm thick phenolic laminated sheet top covers on and including sunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light/fan point controlled by one switch 5 Amps one way single pole complete including taking down old unsv wiring all as specified and directed.
All as per item No. 76 here-in-before but one three pin 5 Amps socket out let on independent board complete all as specified and as directed.
All as per item No. 76 here-in-before but one three pin 5 Amps socket out let on same board complete all as specified and as directed.
All as per item No. 76 here-in-before but, point wiring of copper cable multi stranded 2x2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
S&F Modular switch 1 way 6A ,1 module complete all as specified and directed.
S&F Modular switch 1 way 16 A ,1 module complete all as specified and directed.
S&F Modular socket outlet 6 A,2/3 pin , combined 2 module complete all as specified and directed.
S&F Modular socket outlet 16 A,2/3 pin , combined 2 module complete all as specified and directed.
S&F Modular fan step regulator single module,120w flush type complete all as specified and directed.
M&L in repair sub main wiring with 2 runs of 4 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade as per IS and one run of 2.5 sqmm size PVC insulated copper conductor complete all as specified and directed. Note:- Two run of cable with earth conductor including PVC rigid conduit shall be measured as one length).
M&L in repair sub main wiring with 2 runs of 6 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed PVC conduit min 20mm dia including PVC rigid conduit medium grade as per IS and one run of 4.00 sqmm size PVC insulated copper conductor complete all as specified and directed. Make : Finloex/Havells/Standard Note:- Two run of cable with earth conductor including PVC rigid conduit shall be measured as one length)
S&F ultra modern recess mounting luminaire with high brightness SMD LED light fitting suitable for armstrong/grid ceiling complete all as specified and as directed.. Make - Havells cat part No PLUTONEO 4x1PLR36WLED857S or equivalent model of Philips/Wipro..
Attending of electric ceiling/exhaust/wall mounted/cabin fans and geysers of any make and type complaints of all nature i.e slow running, no running, including carry out all other repairs to make by replacing switch, regulator, capacitor, split pin , screws washers etc and fans make functional at site of Cabinet Sectt under jurisdiction of AGE E/M Cab Sectt wef 0930 Hrs to 1730 Hrs including record the complaints in complaint register collection of maintenance store from store etc complete all as specified and as directed.
Note: (a) Stores required for repair shall be measured and paid separately under respective items of sch.
(b) Replacement of worn out cables/wires etc. including excavation and cost of Tower wagon, cable fault locator equipment and all required tools, ladders, and all other incidental operations required for execution of maintenance work are included in the quoted rate for smooth operation.
(c) Adequate resources shall be deployed by the contractor for attending and rectifying the complain being an essential deptt.
(d) All the T&P items like eight feet height aluminium folding ladder with self supported, drill machine with bits of any size shall be arranged by the contractor at no extra cost at the time of commencement of work other wise Rs 500/day shall be recovered from the contractor. Tool Bags required for attending the complaint shall be issued by contractor to the tradesman.
(e) All the stationery i.e complaint register, job card dockets and other connected register related to the work shall be arranged and to be maintained by the contractor.
(f) Contractor shall be panelised @ Rs. 400/- per complaint/ day, if he fails to attend and rectified the complaint within 8 hours including Sunday/Saturday/Holiday on direction by verbally/telephonically.
(g) For any nature of complaint related to electric appliances other than complaint maintained in above description are also required to be done by the person employed as directed by the concern JE E/M other wise penalty @ of Rs 200/complaint shall be recovered.
(h) Any minor stores required for rectification of electric complaints other than item mentions in CA as provided by the department will also required to be fixed by the persons employed under subject CA without any extra cost .
(j) Cost of all consumable items like cotton waste, PVC insulation tape, nut bolts, screws shall deemed to be included in quoted rate.
SANJEEV ENTERPRISES
GLIBS CONSTRUCTION
KRISHANA ELECTRIC WORKS
SNOWY ENGINEERING INC
VINAY ENTERPRISES
M/S GEETANJALI ENTERPRISES
SETHI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .