Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LQualified | ₹1.2 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹1.5 L+₹30,100 (25.5%)Qualified GROUND FLOOR WARD 13 POLICE THANA ROAD NAWKOTHI BEGUSARAI BIHAR 851130 | BEGUSARAI | BIHAR | 851130 | ₹1.5 L+₹30,100 (25.5%) | L2 | Qualified MII |
| 3 | L3₹1.6 L+₹42,700 (36.2%)Qualified | ₹1.6 L+₹42,700 (36.2%) | L3 | Qualified MII |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
16 Aug 2022, 1:00 pmClosed
Repair of package type ductable AC Plant
3658756
GEM/2022/B/2415834
Repair of package type ductable AC Plant of Cap 3 x 5.5 TR. SM.MES NO 416.175.SA.16. 416.176.SA.16.
15 days
West Bengal; Darjeeling
Total value wise evaluation
BOQ
1 document required · 1 mandatory
Exempted
16 Aug 2022
5 Aug 2022
16 Aug 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) | Spec |
|---|---|---|---|---|---|---|---|
| 1 | Repair of package type ductable AC Plant of Cap 3 x 5.5 TR. SM.MES NO 416.175.SA.16. 416.176.SA.16. 416.177.SA.16 at WSA DB NO 11 at Air Force Station Bagdogra. 01 | Dismantling of defective package type ductable AC plant of Cap 3x5.5 TR capacity unit of any make thorough checking or repair of all accessories and components and reassembling the same after repair or replacement of defective accessories or components and testing complete all as directed by Engineer In Charge including transportation to workshop and back. Note i. Supplying of new accessories or components required for the system shall be measured & paid separately here in after. ii. Supply of sealed compressor unit painting etc shall be measured and paid separately. ii. Old serviceable accessories or components obtained from dismantling shall be refixed as directed by Engineer in Charge and labour charges for refixing shall be deemed to be included in the unit of item rate.Dismantling of defective package type ductable AC plant of Cap 3x5.5 TR capacity unit of any make thorough checking or repair of all accessories and components and reassembling the same after repair or replacement of defective accessories or components and testing complete all as directed by Engineer In Charge including transportation to workshop and back. Note i. Supplying of new accessories or components required for the system shall be measured & paid separately here in after. ii. Supply of sealed compressor unit painting etc shall be measured and paid separately. ii. Old serviceable accessories or components obtained from dismantling shall be refixed as directed by Engineer in Charge and labour charges for refixing shall be deemed to be included in the unit of item rate. Each Job 01. | 1 | Each Job | Darjeeling | 15 | |
| 2 | Repair of package type ductable AC Plant of Cap 3 x 5.5 TR. SM.MES NO 416.175.SA.16. 416.176.SA.16. 416.177.SA.16 at WSA DB NO 11 at Air Force Station Bagdogra. 02 | S & F 5.5 TR scroll compressor ductable type suitable for package type ductable AC plant of Cap 3x5.5 TR capacity including taking down unserviceable one. Make Blue star or Kirloskar or LG or Carrier. Note. unserviceable compressor shall be the property of contractor. Each 01. | 1 | Each Job | Darjeeling | 15 | - |
| 3 | Repair of package type ductable AC Plant of Cap 3 x 5.5 TR. SM.MES NO 416.175.SA.16. 416.176.SA.16. 416.177.SA.16 at WSA DB NO 11 at Air Force Station Bagdogra. 03 | S & F Aluminium fan blade 5.5 TR ductable suitable for package type ductable AC plant of Cap 3x5.5 TR capacity outdoor unit including taking down unserviceable one. Each 02. | 1 | Each Job | Darjeeling | 15 | |
| 4 | Repair of package type ductable AC Plant of Cap 3 x 5.5 TR. SM.MES NO 416.175.SA.16. 416.176.SA.16. 416.177.SA.16 at WSA DB NO 11 at Air Force Station Bagdogra. 04 | S&F 3 Pole power contactor of following capacity 40 Amp including taking down unserviceable one. Make Havells or Legrand or Seimens or L&T. Each 02. | 1 | Each Job | Darjeeling | 15 | - |
| 5 | Repair of package type ductable AC Plant of Cap 3 x 5.5 TR. SM.MES NO 416.175.SA.16. 416.176.SA.16. 416.177.SA.16 at WSA DB NO 11 at Air Force Station Bagdogra. 05 | Supply & filling refrigerant gas R 22 for charging of 1.5 TR to 11.6 TR capacity split mega split and ductable split type AC complete all as specified. 12 Kg. | 1 | Each Job | Darjeeling | 15 | |
| 6 | Repair of package type ductable AC Plant of Cap 3 x 5.5 TR. SM.MES NO 416.175.SA.16. 416.176.SA.16. 416.177.SA.16 at WSA DB NO 11 at Air Force Station Bagdogra. 06 | Dismantling unsv remote control assembly and replacing unsv items Changing of PCB Board to replace any existing faulty mechanical support and reducing the chances of errors and also the possibilities of short circuit of the air conditioning system. Such as IC. PCB. Transformer and magnetic coil suitable for indoor of capacity 5.5 TR package type AC and reassembling the same after testing complete. Each 02. | 1 | Each Job | Darjeeling | 15 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3658756.pdf
GEM_BID
specifications-ac_2022-08-05-12-18-37_4abc5de3b6392eae3370833f98c3228e.pdf
BOQ
boq_repair_of_ac_2022-08-05-12-18-37_f7142fa675640fb903c31480d43c763b.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .