| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAdmitted-Finance | ₹25.8 L | L1 | Admitted-Finance |
| 2 | L2₹26.5 LAdmitted-Finance | ₹26.5 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical The firm has not submitted required documents as per NIT |
| 4 | Rejected-Technical | - | - | Rejected-Technical The firm has not submitted required documents as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical The firm has not submitted required documents as per NIT |
| Sl No | Description | Qty | Unit | HARIOM ENTERPRISES L2 | SRVST CONSTRUCTION PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 100 mm dia pipe | 110.4 | Meter | 55 ₹6,072 | 50 ₹5,520 |
| 2.00 | Dismantling G.I. pipes (external work) ncluding excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore | 180 | Meter | 110 ₹19,800 | 100 ₹18,000 |
| 3.00 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. | 18 | Each | 21 ₹378 | 20 ₹360 |
| 4.00 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal ofunserviceable materials within 50 metres lead. | 18 | Each | 110 ₹1,980 | 100 ₹1,800 |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 2.25 | CUM | 6,500 ₹14,625 | 7,000 ₹15,750 |
| 6.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zoneIII) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 45 | SQM | 580 ₹26,100 | 600 ₹27,000 |
| 7.00 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch inproper shape, raking out joints and preparing a nd plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) | 250.01 | SQM | 750 ₹1.9 L | 750 ₹1.9 L |
| 8.00 | Renewing glass panes and refixing existing wooden fillets. Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) | 2.67 | SQM | 950 ₹2,536.50 | 1,000 ₹2,670 |
| 9.00 | Providing & fixing White vitreous china water closet (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm | 18 | Each | 9,000 ₹1.6 L | 8,000 ₹1.4 L |
| 10.00 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. | 90 | Each | 100 ₹9,000 | 200 ₹18,000 |
Updated dates
Tender Value
₹26.2 L
EMD Value
₹52,500
Closing Date
29 Apr 2026, 10:00 amClosed
Commandant Engineer South Zone HQr CRPF at HYDERAB
CONTRACT CELL SOUTH ZONE HQR CRPF HYDERABAD TELANGANA
Repair and maintenance of old Type-II Family residential quarters from 2157 to 2174 of A Block Total-18 Nos Quarters at GC CRPF Avadi Chennai-55
2026_CRPF_900150_2
B.V-4/2025-26-SZ-Works (GC AVD) Minor Work T/033
Open Tender
Civil Works
60 days
GC CRPF AVADI CHENNAI
AS PER NIT
3 documents required · 3 mandatory
₹0
₹52,500
31 May 2026
18 Apr 2026
1 May 2026
18 Apr 2026
29 Apr 2026
18 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 100 mm dia pipe | - | Meter | - | - | BI01010001010000000000000515BI0100001113 |
| 2 | Dismantling G.I. pipes (external work) ncluding excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore | - | Meter | - | - | BI01010001010000000000000515BI0100001114 |
| 3 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. | - | Each | - | - | BI01010001010000000000000515BI0100001115 |
| 4 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal ofunserviceable materials within 50 metres lead. | - | Each | - | - | BI01010001010000000000000515BI0100001116 |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | - | CUM | - | - | BI01010001010000000000000515BI0100001117 |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zoneIII) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | - | SQM | - | - | BI01010001010000000000000515BI0100001118 |
| 7 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch inproper shape, raking out joints and preparing a nd plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) | - | SQM | - | - | BI01010001010000000000000515BI0100001119 |
| 8 | Renewing glass panes and refixing existing wooden fillets. Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) | - | SQM | - | - | BI01010001010000000000000515BI0100001120 |
| 9 | Providing & fixing White vitreous china water closet (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm | - | Each | - | - | BI01010001010000000000000515BI0100001121 |
| 10 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. | - | Each | - | - | BI01010001010000000000000515BI0100001122 |