Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 52 CORPORATE HOUSE JUDGES BUNGLOW ROAD BODAKDEV AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | Admitted-Finance |
| 2 | Admitted-Finance OLYMPIA PLATINA PLOT NO 33B SOUTH PHASE GUINDY CHENNAI 600032 | CHENNAI | CHENNAI | TAMIL NADU | 600032 | Admitted-Finance |
| 3 | Rejected-Technical 2ND FLOOR 4 329A OLD MAHABALIPURAM ROAD CHENNAI TAMIL NADU CHENNAI TAMIL NADU 600041 | CHENNAI | TAMIL NADU | 600041 | Rejected-Technical Techno-Commercially Rejected as per attached summary |
Tender Value
Refer Docs
Closing Date
23 May 2024, 3:00 pmClosed
Mr. SUSHANT DESHPANDE
thyssenkrupp Uhde India Private Limited, Vikhroli Mumbai ,India.
Supply of AC UPS SYSTEM WITH BATTERIES FOR GDS AND PFCC UNIT FOR NREP
2024_NRL_793543_1
TK-1ZZZA-MP-RFQ-0097
Open Tender
Miscellaneous Goods
Supply
300 days
Numaligarh Refinery Limited Assam
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
ONLINE AS PER MS TEAMS LINK PROVIDED IN NIT
20 Sept 2024
2 Feb 2024
24 May 2024
2 Feb 2024
23 May 2024
26 Feb 2024
2 Feb 2024 - 16 Feb 2024
19 Feb 2024
SUPPLY OF AC UPS SYSTEM WITH BATTERIES FOR GDS &PFCC UNIT FOR NREP as per Technical Specification
Tag No. 1U64-SRR7-UPS-501: (1 Lot) 135 kVA, 115 V, 50 Hz, 1 Phase, Parallel Redundant UPS with Common Static Type Stabilized Bypass supply, Redundant Ni-Cd Battery Bank (100% capacity each, 30 min back-up), ACDB, Battery isolator box with MCCB (flameproof suitable for Gas Group IIC), Battery bank stand, Interconnection cables from Battery charger to Battery bank and suitable termination arrangement with flameproof (Ex-d) nickel plated brass DC cable gland on either sides. Cell Booster-(1 Lot) Cell booster: Input supply 240 V±10% AC, 50±3% Hz Output Voltage: 0-12 V DC Rating: 0.2 X Ah of cell Condition Monitoring System as per Specifications for above UPS System (1 Lot)
Tag No. 1U64-SRR7-UPS-502: (1 Lot) 80 kVA, 115 V, 50 Hz, 1 Phase, Parallel Redundant UPS with Common Static Type Stabilized Bypass supply, Redundant Ni-Cd Battery Bank (100% capacity each, 30 min back-up for DCS & 120 min back-up for communication as mentioned in specification), ACDB, Battery isolator box with MCCB (flameproof suitable for Gas Group IIC), Battery bank stand, Interconnection cables from Battery charger to Battery bank and suitable termination arrangement with flameproof (Ex-d) nickel plated brass DC cable gland on either sides. Cell Booster-(1 Lot) Cell booster: Input supply 240 V±10% AC, 50±3% Hz Output Voltage: 0-12 V DC Rating: 0.2 X Ah of cell Condition Monitoring System as per Specifications for above UPS System (1 Lot)
Charges for SITE Supervision of Erection / Installation and Testing for SUPPLY OF AC UPS WITH BATTERIES FOR GDS & PFCC UNIT FOR NREP PROJECT as per MR
Per diem charges for upto 8 hours work on normal working days.
Overtime rate / hour beyond normal 8 hours work on normal working days.
Overtime rate / hour for work on weekly off days / holidays (as applicable to Refinery site).
Charges for Training at Vendor Works for AC UPS WITH BATTERIES FOR GDS & PFCC UNIT as specified in MR
Per diem charges for upto 8 hours work on normal working days.
Charges for Training at site for AC UPS WITH BATTERIES FOR GDS & PFCC UNIT as specified in MR
Per diem charges for upto 8 hours work on normal working days.
Description of Work / Item(s)
Amount
BREAK-UP OF TOTAL MANDATORY SPARES PRICES SUPPLY OF AC UPS SYSTEM WITH BATTERIES FOR GDS & PFCC UNIT FOR NREP- 1U64-SRR7-UPS-501
BREAK-UP OF TOTAL MANDATORY SPARES PRICES SUPPLY OF AC UPS SYSTEM WITH BATTERIES FOR GDS & PFCC UNIT FOR NREP- 1U64-SRR7-UPS-502
Description of Work / Item(s)
Amount
BREAK-UP OF TOTAL TWO YEARS OPERATIONAL SPARES PRICES SUPPLY OF AC UPS SYSTEM WITH BATTERIES FOR GDS & PFCC UNIT FOR NREP- 1U64-SRR7-UPS-501
BREAK-UP OF TOTAL TWO YEARS OPERATIONAL SPARES PRICES SUPPLY OF AC UPS SYSTEM WITH BATTERIES FOR GDS & PFCC UNIT FOR NREP- 1U64-SRR7-UPS-502
Description of Work / Item(s)
Amount
SUPPLY OF AC UPS SYSTEM WITH BATTERIES FOR GDS &PFCC UNIT FOR NREP as per Technical Specification
1U64-SRR7-UPS-501
1U64-SRR7-UPS-502
Description of Work / Item(s)
Amount
ADDITION / DELETION Unit rates for addition / deletion of following for ACDB feeders if required to be operated later due to detailed engineering changes
16A, 1 phase, SFU Feeder complete with fixed module
32A, 1 phase, SFU Feeder complete with fixed module
63A, 1 phase, SFU Feeder complete with fixed module
100A, 1 phase, SFU Feeder complete with fixed module
125A, 1 phase, SFU Feeder complete with fixed module
150A, 1 phase, SFU Feeder complete with fixed module
Hitachi Hi-Rel Power Electronics Pvt. Ltd.
Vertiv Energy Pvt Ltd
Vertiv Energy Pvt Ltd
Hitachi Hi-Rel Power Electronics Pvt. Ltd.
Hitachi Hi-Rel Power Electronics Pvt. Ltd.
Hitachi Hi-Rel Power Electronics Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .