Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.9 LAccepted-AOC | ₹58.9 L Quoted ₹62.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹69.7 L+₹7.7 L (12.4%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹69.7 L+₹7.7 L (12.4%) | L2 | Rejected-Finance High Rate Quoted |
| 3 | L3₹71.9 L+₹9.9 L (16.0%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹71.9 L+₹9.9 L (16.0%) | L3 | Rejected-Finance High Rate Quoted |
| 4 | L4₹73.5 L+₹11.5 L (18.5%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | ₹73.5 L+₹11.5 L (18.5%) | L4 | Rejected-Finance High Rate Quoted |
| 5 | L5₹79.9 L+₹17.9 L (28.9%)Rejected-Finance | ₹79.9 L+₹17.9 L (28.9%) | L5 | Rejected-Finance High Rate Quoted |
Tender Value
₹71.8 L
EMD Value
₹1.3 L
Closing Date
15 Mar 2024, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Repair/Replacement of LT OH Line and underground cable at certain MD Accn at Mil Stn Bikaner
2024_MES_642774_1
CA No CWE BKN-Token No. 100/2023-2024
Open Tender
Miscellaneous Works
Item Rate
300 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE (N) Bikaner
₹1.3 L
Yes
2 May 2024
16 Feb 2024
22 Mar 2024
16 Feb 2024
15 Mar 2024
8 Mar 2024
16 Feb 2024 - 29 Feb 2024
Amount
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in copings, pedestal of poles and the like including use and waste of form work (straight or curved), all exposed surface of concrete finished even & smooth without using extra cement, complete all as specified & as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes : (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS-5820 complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
All as per serial item No 7.00 here-in-before but of size 25 Sqmm 4 Core complete all as specified & as directed.
All as per serial item No 7.00 here-in-before but of size 35 Sqmm 3.5 Core complete all as specified & as directed.
All as per serial item No 7.00 here-in-before but of size 120 Sqmm 3.5 Core complete all as specified & as directed.
All as per serial item No 7.00 here-in-before but of size 185 Sqmm 3.5 Core complete all as specified & as directed.
All as per serial item No 7.00 here-in-before but of size 240 Sqmm 3.5 Core complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volt cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volt cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm complete all as specified & as directed.
Boring of holes 100mm bore horizontally under road without damaging, pavement, hard standing the surface (minimum 1.0 metre below the road surface) etc by trench less technology using necessary machine / manually without disturbing the top surface of roads suitable for passing the GI protection pipe / cables, complete all as specified and as directed.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/ under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized iron earth wire 4 mm dia as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and other end of earth wire connected to transformer / GOD / Panel / equipment body / test point, GI earth wire encased in and including 15mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for Earthing to Transformer / GOD switch / equipments / panels etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to transformer / GOD / Panel / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for preparation old painted surfaces by scraping and removing old paints, rust etc from steel tubular pole (above the planting depth and PCC coping) and mild steel cross Arms, Cable protection pipe, brackets etc and applying two coats of synthetic enamel paint in alternate black and yellow strips painting (4 Nos Each strip 300mm Each wide) and applying two coats of aluminium paint to remaining portion of steel pole etc and marking pole number in letters & figures of size not less than 8cm height including preparation of old surfaces for painting complete all as specified & as directed.
Supply and fixing FRLS PVC insulated copper conductor, three core of size 1.5 sqmm, 1100 Volt grade (ISI marked) complete all as specified and directed.
Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK), outdoor type (cubical type), platform mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated copper bus bars of 500 Amps rating in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-53 and made out of CRCA sheet of 3.15mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 50mmx50mmx6mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland complete and also comprising of the following:- (Location : HE Old Block NO. P-4-5 and P-3, P-4) (Description of serial item No. 21.00 contd....)
Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK), outdoor type (cubical type), platform mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated copper bus bars of 500 Amps rating in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-53 and made out of CRCA sheet of 3.15mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 50mmx50mmx6mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland complete and also comprising of the following:- (Location : HE Old Block NO. P-1 and P-6, P-7) (Description of serial item No. 22.00 contd....)
Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK), outdoor type (cubical type), platform mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated copper bus bars of 350 Amps rating in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-53 and made out of CRCA sheet of 3.15mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 50mmx50mmx6mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland complete and also comprising of the following:- (Location : Old Umrao P-53 and P-73) (Description of serial item No. 23.00 contd....)
Supply, installation, testing and commissioning factory made and tested (CPRI type test certified) LT feeder pillar box (KIOSK), outdoor type (cubical type), platform mounted, suitable for 415 volts 3 phase & neutral, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated copper bus bars of 400 Amps rating in colour code RYB with 3 phase & neutral installed on porcelain insulators with bus bar chamber shall be provided with inspection covers, each MCCB/cubical switch independent opening. The panel shall be dust & vermin proof, protection class IP-53 and made out of CRCA sheet of 3.15mm thick, powder coated finish on outside & inside surfaces (approved shade), double door (front & rear), in two shalves with provision of rubber beading and front opening type with aprons for cable entry, with double door shutter & locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, dange notice board in front and rear sidesand MS angle iron frame work (made out of 50mmx50mmx6mm thick), frame legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) including internal wiring with PVC insulated, solid copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 6 sqmm with proper ferrule & cable gland complete and also comprising of the following:- (Location : Umrao booster No 41) (Description of serial item No. 24.00 contd....)
Supply and fixing Junction box of size 205x205x112mm made out of thermoplastic material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP-55 with integrated membranes/ metric knockouts for cable entry with cable glands, protection and suitable size of "connectwell" stud teriminal (provision for socket bolting) - 05 Nos suitable for 415 volts, 50 Hz, 03 Phase, 4 wire internal wiring system including MCB SP 06 Amp - 01 No and mounted on tubular / PCC Pole with suitable clamps of size 32x6mm - 02 Nos, nuts, bolts, including taking down old unserviceable Junction box complete all as specified and directed.
Supply and fixing in Bus bar chamber cubical type of size 80x50x40cm (Box size) with bus bar chamber having 4 wire, 415 volts, factory made dust proof vermin proof for outdoor using made out of CRCA sheet 3.15mm thick powder coated, machine pressed both side opening in two shalves with provision of rubber beadings and locking system, including copper bus bar of 150 Amp capacity, 4 strip mounted on DMC/ Epoxy insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have independent opening, panel shall be mounted on angle iron frame and legs made from angle of size 40x40x6mm, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) complete including following accessories complete all as specified and directed :- (i) MCCB, 4 Pole, 415 Volt grade, AC, 50 Hz, 100 Amps rating, rupturing capacity not less than 25 kA, Icu=100% Ics, thermal magnetic trip adjustable type with built in protection function for overload, short circuit and tripping mechanism complete with spreader link – 01 No
Supply and fixing in Bus bar chamber cubical type of size 80x50x40cm (Box size) with bus bar chamber having 4 wire, 415 volts, factory made dust proof vermin proof for outdoor using made out of CRCA sheet 3.15mm thick powder coated, machine pressed both side opening in two shalves with provision of rubber beadings and locking system, including copper bus bar of 100 Amp capacity, 4 strip mounted on DMC/ Epoxy insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have independent opening, panel shall be mounted on angle iron frame and legs made from angle of size 40x40x6mm, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) complete including following accessories complete all as specified and directed :- (i) MCCB, 4 Pole, 415 Volt grade, AC, 50 Hz, 63 Amps rating, rupturing capacity not less than 25 kA, Icu=100% Ics, thermal magnetic trip adjustable type with built in protection function for overload, short circuit and tripping mechanism complete with spreader link – 01 No
Dismantling eath wire from existing system complete all as specified & as directed.
Dismantling of stay assembly complete all as specified and as directed.
Dismantling cross arms, bracing, supports, clamps and back plates, mild steel channel or angle sections etc complete all as specified & as directed.
Dismantling & taking down old unserviceable any type, any size insulator, complete all as specified & as directed.
Dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/type/capacity, complete all as specified and as directed.
Dismantling of steel tubular pole of any description with GI pipe complete all as specified & as directed.
M/s Rohit Construction Co.
M/S BUDHRAM BISHNOI
Pioneer Enterprises
M/s MAKHAN ENTERPRISES
M/s Chopra Associates
B K CONTRACTORS
B5BUILDING SOLUTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .