| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance 21 GURUKRIPA PATIL LAYOUT GOPLA NAGAR NAGPUR 440022 | NAGPUR | NAGPUR | MAHARASHTRA | 440022 | L1 | Admitted-Finance | |
| 2 | L2₹1.5 Cr+₹8.0 L (5.87%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹1.5 Cr+₹9.4 L (6.88%)Admitted-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L3 | Admitted-Finance | |
| 4 | L4₹1.5 Cr+₹9.8 L (7.19%)Admitted-Finance 114 BARI BAZAR SADAR CANTT LUCKNOW UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | L4 | Admitted-Finance | |
| 5 | L5₹1.5 Cr+₹14.5 L (10.6%)Admitted-Finance PLOT NO 127 3 A RATNASAGAR FLATS SECTOR 19 GANDHINAGAR 382019 | GANDHINAGAR | GANDHINAGAR | GUJARAT | 382019 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Asha Enterprises L1 | divyarsh entrprise L5 | SNEH TRADERS L8 | DMA PROJECTS L7 | Panwar Construction Co. L2 | VIJAY CONSTRUCTION CO L6 | M/s Ram Singh Agarwal L4 | R K CONTRACTOR AND SUPPLIERS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 m in depth for foundation n.exc. 10 Sqm on plan and n.exc 1.5 mtr in depth and getting out complete in soft/loose soil complete all as specified and directed. | 258 | Cum | 300 ₹77,400 | 310 ₹79,980 | 320 ₹82,560 | 300 ₹77,400 | 160 ₹41,280 Lowest | 290 ₹74,820 | 190 ₹49,020 | 250 ₹64,500 |
| 2.00 | Returning filling in and including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/ loose soil complete all as specified and directed. | 124 | Cum | 100 ₹12,400 | 310 ₹38,440 | 320 ₹39,680 | 300 ₹37,200 | 70 ₹8,680 Lowest | 290 ₹35,960 | 90 ₹11,160 | 250 ₹31,000 |
| 3.00 | Removing excavated soil to a distance exc 250m and n. exc 500m or remove out of MOD land as directed by Engr-in-Charge. | 134 | Cum | 100 ₹13,400 | 310 ₹41,540 | 320 ₹42,880 | 300 ₹40,200 | 85 ₹11,390 | 290 ₹38,860 | 80 ₹10,720 Lowest | 250 ₹33,500 |
| 4.00 | M & L cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) for foundation filling and mass concrete complete all as specified and directed. | 25.5 | Cum | 4,000 ₹1,02,000 | 3,200 ₹81,600 | 5,500 ₹1,40,250 | 3,500 ₹89,250 | 3,700 ₹94,350 | 3,100 ₹79,050 | 3,500 ₹89,250 | 3,000 ₹76,500 Lowest |
| 5.00 | S & F of precast footing design for single column placement of size (base +pedestal) 1450 mm x 900mm x 800 mm ,have base of 1450 mm x 900mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 550 mm x 600mm (hollow part 250 mm x 250 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with BIS ,JIS, and ISO-9001 standards. The curing process must be maintained using RO water and chiller plants for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1015 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Cover-I "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 135 | Each | 27,000 ₹36,45,000 Lowest | 31,000 ₹41,85,000 | 55,000 ₹74,25,000 | 32,000 ₹43,20,000 | 30,000 ₹40,50,000 | 29,500 ₹39,82,500 | 31,900 ₹43,06,500 | 29,000 ₹39,15,000 |
| 6.00 | S & F of precast footing design for double column placement of size (base +pedestal) 1450 mm x 1125 mm x 800 mm ,have base of 1450 mm x 1125 mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 775 mm x 600mm (hollow part 250 mm x 475 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1280 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Cover-I "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 42 | Each | 35,000 ₹14,70,000 | 39,000 ₹16,38,000 | 64,000 ₹26,88,000 | 40,000 ₹16,80,000 | 34,800 ₹14,61,600 Lowest | 39,000 ₹16,38,000 | 34,980 ₹14,69,160 | 38,500 ₹16,17,000 |
| 7.00 | S & F of precast I-shaped column of size 3000mm x 200mm x 200mm, having flange thickness of 60 mm and web thickness 80 mm will place on precast footing and will be grouted , having a bolts fixed at top of column, having 4 mm thick high tensile tendon steel 10 nos in each column which is made of high performance self compacting concrete (SCC) of M-40 grade, cured under controlled factory conditions through steam curing,. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. concrete mix design of IS:9103 with weight of each column at least 228 kg (tolerance limit 1.5%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 218 | Each | 6,500 ₹14,17,000 Lowest | 6,700 ₹14,60,600 | 8,200 ₹17,87,600 | 6,800 ₹14,82,400 | 6,975 ₹15,20,550 | 7,200 ₹15,69,600 | 7,100 ₹15,47,800 | 6,500 ₹14,17,000 Lowest |
| 8.00 | S & F of precast panel have both side design as per Engineer-in-charge of size 3000mm x 1200 mm x 75mm having 4 mm thick high tensile tendon steel 10 nos in each panel which is made of high performance self compacting concrete (SCC) of M-40 grade with high tensile tendon steel, cured under controlled factory conditions through steam curing. All manufacturing process must comply with Indain standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made automobile grade water tight steel enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each panel at least 675 kg (tolerance limit 1%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) Design given in the drawing is tentative, actual design will be as per sample approval.
(ii) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(iii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 354 | Each | 18,500 ₹65,49,000 Lowest | 20,500 ₹72,57,000 | 32,500 ₹1,15,05,000 | 22,000 ₹77,88,000 | 19,500 ₹69,03,000 | 21,500 ₹76,11,000 | 19,150 ₹67,79,100 | 20,000 ₹70,80,000 |
| 9.00 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 318 | Cum | 110 ₹34,980 | 100 ₹31,800 Lowest | 100 ₹31,800 Lowest | 250 ₹79,500 | 200 ₹63,600 | 100 ₹31,800 Lowest | 190 ₹60,420 | 200 ₹63,600 |
| 10.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. | 25 | Cum | 100 ₹2,500 Lowest | 100 ₹2,500 Lowest | 100 ₹2,500 Lowest | 300 ₹7,500 | 160 ₹4,000 | 100 ₹2,500 Lowest | 140 ₹3,500 | 200 ₹5,000 |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
12 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) LUCKNOW
GE (WEST) LUCKNOW PIN-226002
SPECIAL REPAIR TO BOUNDARY WALL OF 2 ATAL ROAD UNDER GE (WEST) LUCKNOW
2026_MES_789617_1
GE/W/LKO/T-93 OF 2026-27
Open Tender
Civil Works
Item Rate
150 days
GE (WEST) LUCKNOW
As per NIT and Tender document
8 documents required · 8 mandatory
₹1,000
GE (WEST) LUCKNOW
₹2.9 L
23 Nov 2026
16 Sept 2026
14 Oct 2026
16 Sept 2026
12 Oct 2026
30 Sept 2026
16 Sept 2026 - 23 Sept 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches n.exc 1.5 m in depth for foundation n.exc. 10 Sqm on plan and n.exc 1.5 mtr in depth and getting out complete in soft/loose soil complete all as specified and directed. | 258 | Cum | - | - |
| 2 | Returning filling in and including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/ loose soil complete all as specified and directed. | 124 | Cum | - | - |
| 3 | Removing excavated soil to a distance exc 250m and n. exc 500m or remove out of MOD land as directed by Engr-in-Charge. | 134 | Cum | - | - |
| 4 | M & L cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) for foundation filling and mass concrete complete all as specified and directed. | 25.5 | Cum | - | - |
| 5 | S & F of precast footing design for single column placement of size (base +pedestal) 1450 mm x 900mm x 800 mm ,have base of 1450 mm x 900mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 550 mm x 600mm (hollow part 250 mm x 250 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with BIS ,JIS, and ISO-9001 standards. The curing process must be maintained using RO water and chiller plants for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1015 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Cover-I "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 135 | Each | - | - |
| 6 | S & F of precast footing design for double column placement of size (base +pedestal) 1450 mm x 1125 mm x 800 mm ,have base of 1450 mm x 1125 mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 775 mm x 600mm (hollow part 250 mm x 475 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1280 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Cover-I "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 42 | Each | - | - |
| 7 | S & F of precast I-shaped column of size 3000mm x 200mm x 200mm, having flange thickness of 60 mm and web thickness 80 mm will place on precast footing and will be grouted , having a bolts fixed at top of column, having 4 mm thick high tensile tendon steel 10 nos in each column which is made of high performance self compacting concrete (SCC) of M-40 grade, cured under controlled factory conditions through steam curing,. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. concrete mix design of IS:9103 with weight of each column at least 228 kg (tolerance limit 1.5%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 218 | Each | - | - |
| 8 | S & F of precast panel have both side design as per Engineer-in-charge of size 3000mm x 1200 mm x 75mm having 4 mm thick high tensile tendon steel 10 nos in each panel which is made of high performance self compacting concrete (SCC) of M-40 grade with high tensile tendon steel, cured under controlled factory conditions through steam curing. All manufacturing process must comply with Indain standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made automobile grade water tight steel enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each panel at least 675 kg (tolerance limit 1%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) Design given in the drawing is tentative, actual design will be as per sample approval.
(ii) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(iii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 354 | Each | - | - |
| 9 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 318 | Cum | - | - |
| 10 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. | 25 | Cum | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderT-93.pdf
Tender Documents • 1.09 MB
BOQ_885134.xls
BOQ • 0.24 MB
FENCINGDrawing.pdf
Additional Documents • 0.81 MB
CORREGENDUMTdate.pdf
PDF • 0.19 MB
CORREGENDUM.pdf
PDF • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .